Your SlideShare is downloading. ×
  • Like
Honeywell vista-50p-data-sheet
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Now you can save presentations on your phone or tablet

Available for both IPhone and Android

Text the download link to your phone

Standard text messaging rates apply

Honeywell vista-50p-data-sheet

  • 435 views
Published

Alarm Grid Home Security http://www.alarmgrid.com/ has provided this pdf with the permission and courtesy of Honeywell. …

Alarm Grid Home Security http://www.alarmgrid.com/ has provided this pdf with the permission and courtesy of Honeywell.

Alarm Grid is a home security product and alarm monitoring company that loves its customers. We have a strong appreciation of the DIY community, and want to make sure that we not only provide the best products and services out there but we also want to make sure that resources like these Honeywell product pdfs are easily accessible so that or curious customers can find what they need when they need it.

  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
435
On SlideShare
0
From Embeds
0
Number of Embeds
0

Actions

Shares
Downloads
2
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. VISTA-50PCONTROL PANELHoneywell’s VISTA-50P Control Panel provides the flexibility of up to eight independent partitions with the economyof a single control.FEATURESDependable features to meet your most End users will appreciate the easy-to-usedemanding installations: convenience and control features of the VISTA-50P:• Nine hardwired zones standard • Wireless remote controls (featuring single button system operation):• Expandable to 87 total zones — 5804 - Four-Button Wireless Key• Eight partitions standard — 5804BD - Bidirectional• 75 user codes work in all partitions Four-Button Wireless Key with system status feedback• Seven authority levels • Single or dual-button wireless• 224 event memory log/printer option personal panic:• Four trigger outputs — 5802MN — 5802MN2• 5800 Series wireless compatibility • Home control features activate lights, appliances,• Supports two-wire multiplex garage doors and numerous other devices• Scheduling of events (real time clock) • The VISTA Interactive Phone Module (VIP) gives the• Keypad macro features end-user control of their system from any touchtone• Master console option for viewing all phone. The 4286 VIP responds in English, with a partitions at a glance vocabulary of over 100 words• Common lobby logic • Full English display keypads for clear understanding of system status and zone locations• Fast downloading • Timed event applications:• Supports up to 16 relays and/or X-10 — Opens garage doors and• Quick start programming turns on lights — Provides“lived-in look” while• False alarm features away from home• UL Commercial Burglary listed — Ability to limit access to parts of the (VISTA-50PUL) home at certain times
  • 2. VISTA-50PCONTROL PANELSPECIFICATIONSElectrical • Programmable swinger suppression • Duct Detectors• Aux power 12VDC, 750mA max Communications • Serial Printer• 16.5 VAC/40 VA transformer • Touchtone or pulse • Polling Loop Devices• Alarm output 12VDC, • Formats supported: ADEMCO • Key Switch Devices 1.7 Amps max Contact ID, ADEMCO 4 + 2 Express, Wireless Receiver Systems ADEMCO low speed• For UL installations, combined • 5800 Series Aux and alarm output cannot exceed • 3+1, 4+1 and 4+2 reporting — 5881ENL up to 8 zones-50mA 750mA • Reporting capabilities: Split, — 5881ENM up to 16 zones-50mAOutput Control Dual, Split/Dual — 5881ENH up to 26 zones-50mA• Supports up to four relay boards • Low battery reports 11.2-11.6VDC • All Receivers Support: (Part No. 4204) — Diversity reception with • Expanded reporting two antennea• Each board supports four relays • Up to four digit PABX — Remote mounting for for a total of 16 codes supported best location• Optional X-10 interface (Part No. — Use of second receiver for • True dial tone detection 4300) may be used to control maximum coverage or X-10 receiving devices • Double pole line seizure tough installations• Each X-10 receiver address • AC loss and restoral — Unique supervision and low counts as one relay when computing reporting supported battery indications by point total relays Supported Devices Transmitters• Real time clock can be used for Hardwired Expansion Devices • 5800 Series relay/X-10 control • 4208U Eight-Zone — Three volt Duracell lithium batteriesZones Expansion Module — One mile range — Tamper standard• Nine hardwired zones • Keypads — 6139 Custom English (required for Agency Listings• Selectable response on zone 9: programming) -100mA • UL Residential Fire and Burglary 10MSec or 500MSec — 6128 Fixed English LCD - 30mA and CSFM• Assignable to any partition • Voice Module 4286 VIP-160mA • UL Commercial Burglary• 14 zone types to choose from (VISTA-50PUL) • Two-Wire Smoke Detectors ORDERING VISTA-50P Control PanelAutomation and Control SolutionsHoneywell Security & Communications2 Corporate Center Dr. Suite 100P.O. Box 9040Melville, NY 11747 L/VIS50P/D September 2008www.honeywell.com © 2008 Honeywell International Inc.