Alarm Grid is a home security product and alarm monitoring company that loves its customers. We have a strong appreciation of the DIY community, and want to make sure that we not only provide the best products and services out there but we also want to make sure that resources like these Honeywell product pdfs are easily accessible so that or curious customers can find what they need when they need it.

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
2,370
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
5
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Honeywell Vista 128BPT Datasheet

  1. 1. VISTA-128BPT SERIESPARTITIONED COMMERCIAL BURGLARYALARM CONTROL PANELSThe VISTA-128BPT is a powerful member of the Honeywell The VISTA-128BPT and VISTA-128BPTSIA are listed forfamily of commercial alarm panels, integrating burglary, CCTV residential burglary, residential fire and commercial burglaryand access control functions. Many features are available that applications (see agency listings in this document forextend the applications of the VISTA-128BPT while simplifying more details). They are compatible with a wide range ofend-user operation. AlarmNet communications products for alarm reporting, uploading /downloading and remote services.FEATURESStandard features • Zone 7 may be used for keyswitch • Group bypass(VISTA-128BPT and VISTA-128BPTSIA): arming/disarming • Arm faulted• Provides nine style-B hardwired zones • Integrates with WIN-PAK access • Event arming• Supports up to 119 additional zones control systems to provide increased users, event log and scheduling • Carbon monoxide (CO) zone using a built-in polling (V-Plex®, type support multiplex) loop interface • Supports V-Plex addressable VistaKey access control (up to eight • Expanded high-speed RS-232• Supports up to 127 wireless zones doors and 250 cards) capability for third party interface using up to two 5800 series wireless and automation receivers (fewer if using hardwire • Easily programmed and maintained and/or polling loop zones) by Compass Windows-based • Internet upload/download downloader over AlarmNet GSM and/or• Provides one power-limited bell circuit IP communicators over the panels delivering 1.7Amp (max) at 12VDC • Supports up to 96 programmable keypad (ECP) bus• Provides the ability to control eight outputs • Ringback support for AlarmNet separate partitions independently, • Programmable to meet SIA false communicators (confirmation of each functioning as if it had its own alarm prevention specifications. closing report) separate control To meet UL approval for ANSI/SIA CP-01-2010, order part number • 24-hour dialer test support for• Accommodates 150 user codes with V128BPTSIA AlarmNet devices seven authority levels • Supports up to six touchscreen • Supports V-Plex Smart Contact• Accommodates 32 keypad macro Advanced User Interface (AUI) feature for improved responsiveness commands per system devices (6272 or later) on systems with many V-Plex zones• Keeps a log of up to 512 events • Smoke detector reset at keypad • Telco line cut detection• Supports up to 16 compatible two-wire smoke detectors on zone 1 • Quick exit
  2. 2. VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ADDITIONAL FEATURES Basic Hardwired Zones Wireless Expansion Eight Partitions Provides nine style-B hardwired zones Supports up to 127 wireless zones Provides the ability to control eight with the following characteristics: using up to two 5800 Series wireless separate areas independently, each • EOLR supervision (optional for zones receivers (fewer if using hardwire functioning as if it had its own separate 2-8) supporting N.O. or N.C. sensors and/or polling loop zones). control. Partitioning features include: (EOLR supervision required for fire Wireless zones have the following • A Common Lobby partition (1-8), and UL burglary installations) characteristics: which can be programmed to arm • Individually assignable to one of • Supervised by control panel for automatically when the last partition eight partitions check-in signals (except certain that shares the common lobby is non-supervised transmitters) armed, and to disarm when the first • Up to 16 two-wire smoke detectors partition that shares the common on zone 1 • Tamper protection for supervised lobby is disarmed • Four-wire smoke or heat detectors transmitters • A Master partition (9), used strictly to on zones 1-8 (power to four-wire • Individually assignable to one of assign keypads for the purpose of smoke detectors must be supervised eight partitions viewing the status of all eight partitions with an EOL device). Listed for Scheduling at the same time (master keypads) residential fire only. Provides the following scheduling • All zones assignable to one of Polling Loop Expansion capabilities: eight partitions Supports up to 119 additional zones • Open/close schedules (for control of • Keypads assignable to one of eight using a built-in polling (V-Plex, multiplex) arming/disarming and reporting) partitions or to Master partition 9 to loop interface. Current draw can total • Holiday schedules (allows different view system status up to 128mA. Polling loop zones have time windows for open/close • Ability to assign relays to one or all the following characteristics: schedules) eight partitions • Must use V-Plex devices • Timed events (for activation of relays, • Ability to display fire and/or burglary • Supervised by control panel auto-bypassing and unbypassing, and panic and/or trouble conditions • Individually assignable to one of auto-arming and disarming, etc.) at all other partitions’ keypads eight partitions • Access schedules (for limiting system (selectable option) • Supports VSI Module access to users by time) • Individually programmable account • Supports 4297 Expander Module • End user output programming mode number, entry delay and exit delay • Maximum wiring distance = (provides 20 timers for output control) by partition 12,000 feet V-Plex Loop 5193 4101SN DT7500SN FG1625SN Glassbreak 4208EX Eight-zone 4293SN Adapters Series Smoke Detectors Relay Module V-Plex DUAL TEC V-Plex Expander and Motion Sensor 4208SN Serialized Eight-zone Remote Point Module 5881 ECP Bus Wireless Receiver 6160 Console 710 Strobe Light VISTA-128BPT 4204 Notification Relay Appliances Keyswitch Module Option 4146 Serial Printer PC Connection Phone Line to Central Station 748 Horn RS-232 or or 7847i GSMV iGSMVNOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information.
  3. 3. VISTA-128BPT SERIES PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS ACCESSORIES Auxiliary Devices Passive Infrared Detectors • 5819 - Shock Sensor • 4204 - Relay Module, four form • IS2500SN • 5827BD - Bidirectional Keypad C contacts • DT7500SN • 5853 - Glassbreak Detector • 5881 Series - RF Receiver supporting V-Plex (Addressable) Contacts • 5898 - Wireless DUAL TEC 5800 wireless detectors Motion Sensor • 4939SN-WH • 6160 - Alpha Keypad/Annunciator • 5800PIR-OD - Outdoor Motion Sensor • 4944SN-WH • 6220S - System Printer • 5870API - Asset Protection Device • 4959SN Manual Pull Stations • 5800PIR/5800PIR-RES/5800PIR-COM V-Plex Glassbreak Detectors • 5140MPS-1 - Wireless Motion Detectors • FG1625SN • 5140MPS-2 • 5800CO (5800COA - Canada) - VISTA Interactive Phone Module Wireless Carbon Monoxide Detector V-Plex (addressable) Devices • 4286 VIP Module • 5800RP - Wireless Repeater • 4101SN Single Relay/Zone Module Optional Communicators • 5808W3 (5808W3A - Canada) - • 4190SN Remote Point Module - Wireless Smoke Detector two zones • AlarmNet Internet/Intranet communicators and digital cellular • 5809 - Wireless Heat Detector • 4193SN Two-zone Serial Interface communicators Module Commercial Listed Access Control Wireless Devices • 4208EX - Eight-zone expander for ULC commercial installations • VISTAKey V-Plex (addressable) • 5817CB - Commercial UL Burglary, Access Control Universal Contact Monitoring • 4208SN Loop Expansion Module - Transmitter* eight zones • VISTAKey-SK Starter Kit • 5869 - Commercial UL Wireless • 4209U Group Zoning Module - • VISTAKey-EX Expansion Kit Hold-up Button* two/four zones Wireless Devices • 5881ENHC and 5883H Receivers • 4293SN One-zone Serial • 5804 - Wireless Key Interface Module *When used with 5881ENHC and/or • 5804BD - Bidirectional Key 5883H receiver. • 4297 Isolation/Extender Module • 5804BDV - Bidirectional Key • VSI Short/Overload Isolation Module with voice • 5193SD • 5816 - Door/Window Transmitter • 5193SDT 4190SN 4959SN 4944SN 4193SN Remote Point Module Overhead Door Contact Contact IS2500SN 4208U Two-zone Serial Interface Module V-Plex PIR Eight-zoneMotion Sensor Expansion Module VISTAKey V-Plex 5808W3 5881ENHC (5808W3A - Canada) Glassbreak Detectors Access Control Commercial Wireless Receiver Wireless Module ECP Bus (Max Two) Smoke Detector 5800 Series Wireless 5800PIR Series 6160 5816 Devices Wireless PIRs Console Door/Window Transmitter 4209U Group Zoning Module 5869 Commercial UL Supports Up To Wireless Hold-up 5817CB Universal 16 Conventional 4204 Two-Wire Relay Button Contact Monitoring Smoke Detectors Module Transmitter
  4. 4. VISTA-128BPT SERIESPARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELSSPECIFICATIONSAgency Listed to the Electrical • Standby Time: Four hours min. withFollowing Standards: • Voltage Input: From Honeywell No. 750mA aux. load using 7AH battery• UL609 Grade A Local Mercantile 1361 Plug-In Transformer or • Circuit Protectors: PTC circuit Premises and Mercantile Safe 1361X10 transformer (for X-10 breakers are used on battery input to and Vault installations) rated 16.5VAC, 40 VA protect against reverse battery• UL1610 Grades A, AA • Use 1361CN plug-in transformer connections and on alarm sounder Central Station for Canada output to protect against wiring faults (shorts). A solid state circuit breaker• UL365 Grades A, AA Police Connect • Alarm Sounder Output: is used on auxiliary power output to• UL985 Household Fire 10VDC-13.8VDC, 1.7 amps max., protect against wiring faults (shorts). (UL1023, UL609 installations);• UL1023 Household Burglar Alarm Main Dialer 750mA less aux. current draw California State Fire Marshall (CSFM) (UL985 installations) • Formats Supported: ADEMCO• UL1635 - Digital Alarm Contact ID with support for four-digit • Auxiliary Power Output: 9.6VDC- Communicator System Units and ten-digit accounts and 13.8VDC, 750mA max. For UL• CAN/ULC - S303 installations, the accessories ADEMCO 4 + 2 Express• CAN/ULC - S304 connected to the output must be UL • Line Seize: Double Pole• CAN/ULC - S545 Listed, and rated to operate in the • Ringer Equivalence: 0.7B above voltage range• CAN/ULC - S1023 Cabinet Dimensions • Backup Battery: 12VDC, 4AH or 7AH• For commercial burglary attack 12-1/2" W X 14 1/2" H X 3" D sealed-lead acid. YUASA NP4-12 proof requirements, use N5873V4BE (12V, 4AH) or NP7-12 (12V, 7AH) attack proof enclosure provided in recommended VISTA-ULKT kit ORDERING VISTA-128BPT Commercial Burglary Alarm Control Panel (UL Listed) V128BPTSIA SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed) V128BPTCNKT VISTA-128BPT Commercial Burglary Alarm Control Panel with 1361CN Transformer (Canada only)For more information:www.honeywell.com/security/hscAutomation and Control SolutionsHoneywell Security & Communications2 Corporate Center Dr. Suite 100P.O. Box 9040Melville, NY 11747 L/VSTA128BPTD/D1.800.467.5875 April 2011www.honeywell.com © 2011 Honeywell International Inc.

×