SIPART PS2
s
Leaflet "Operation - a concise overview"

6DR50xx
6DR51xx
6DR52xx
6DR53xx

(Order No. A5E00074611-03)

ATTENT...
Rated angle of rotation of feedback
Set transmission ratio selector (7) appropriately
(see view of device)
Stroke range (o...
Upcoming SlideShare
Loading in...5
×

Siemens sipart ps2 -ops condensedoverview

53

Published on

SIEMENS SIPART PS2

Published in: Technology
0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total Views
53
On Slideshare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
1
Comments
0
Likes
1
Embeds 0
No embeds

No notes for slide

Transcript of "Siemens sipart ps2 -ops condensedoverview"

  1. 1. SIPART PS2 s Leaflet "Operation - a concise overview" 6DR50xx 6DR51xx 6DR52xx 6DR53xx (Order No. A5E00074611-03) ATTENTION: See Operating Instructions for safety instructions ! 1 2 View of device (cover open) 14 10 15 33 O 90° 2 2 18 ... 30V 3 4 5 1 6 7 8 9 BE1 10 3 4 5 6 6.1 6.2 7 8 9 O 6 7 8 9 3 o 90 13 3/4W 2 3 4 5 0/4 ... 20mA 4 ... 20mA 2W 90 10 4 o 33 33° 11 12 13 14 12 6.1 11 10 9 7 8 15 6.2 6 5 Configuring Input: supply air PZ Output: Positioning pressure Y1 Display Output: Positioning pressure Y2 *) Input keys Restrictor Y1 ) Restrictor Y1 * Restrictor Y2 *) Transmission ratio selector Sound absorber Adjustment wheel for slipping clutch Terminals for basic unit Terminals for option modules Plug Cable glant Label (on module cover) Purging air selector Possible messages Display (simultaneously) (simultaneously) Meaning Actuator does not move Acknowledge message using Check restrictor (6) and open if necessary Drive actuator to working range using Restart initialization up to (simultaneously) Change gearing (7) (simultaneously) >5s Down tolerance band violated Continue using or adjust sliding clutch up to display *) With double-action actuators Changing the input level Measures Automatic initial start-up (starting with factory setting) Continue using or Meaning Step Display Mode 1.) P-manual mode Potentiometer setting [%] Part-turn actuator Not initialized (can be reached using preset) Linear actuator Once the slipping clutch has been adjusted Change position using Change parameter name using >5s Press for > 5 s Parameter value 2.) Remaining steps carried out automatically Up tolerance band violated Parameter number Manual mode Change position using 3.) >5s >5s Mode and Setpoint [%] Automatic >5s 1x Position [%] 1x Error code Mode and Setpoint [%] Diagnosis Direction of action is determined Adjust using display: Position [%] Error code Diagnosis value + + >2s Diagnosis number Diagnosis name + >2s + >2s 4.) 5.) Checking of travel and adjustment of zero and stroke (from stop to stop) 6.) key initiates leakage measurement Up/down span violated Determination of minimum increment length 7.) Optimization of transient response 8.) Initialization terminated successfully (travel in mm for linear actuators) (angle of rotation for part-turn Continue using: actuators) up to Continue using Determination and Display of positioning time down (dxx.x), up (uxx.x) Stop with Pressing the Acknowledge message using Set the next highest travel value on the lever Restart initialization Additionally possible with rotary actuators: >5s Parameter name (The gray values in the top display line are examples) Change value using Linear actuator: Set pick-up lever into vertical position using Continue using PRST Configure with “WAY” Actuator does not move Positioning time is possible to adjust Acknowledge message using Set the next lowest travel value on the lever Restart initialization Adjust positioning time using restrictor(s) Continue using See Manual for further messages or
  2. 2. Rated angle of rotation of feedback Set transmission ratio selector (7) appropriately (see view of device) Stroke range (optional setting) 1) 2) 90° 33° Driver pin must be set to the value of the actuator travel or, if this value is not scaled, to the next larger scale value. Factory setting 33° mm OFF 25 | 30 | 35 (short lever 90°) 40 | 50 | 60 | 70 | 90 | 110 | 130 (long lever 90°) Initialization (automatically) 5.INITM Initialization (manually) 6.SCUR Current range of setpoint 7.SDIR noini | no / ###.# | Strt Setpoint direction no noini | no / ###.# | Strt 4.INITA no 0 MA 4 MA riSE FALL 0 to 20 mA 4 to 20 mA rising falling 4 MA riSE Setpoint for start of split range 9.SPRE 0,0 to 100,0 % 0,0 Setpoint for end of split range 8.SPRA 0,0 to 100,0 % 100 s 0 s 0 10.TSUP Setpoint ramp up Auto 0 to 400 11.TSDO Setpoint ramp down 0 to 400 Linear Equal-percentage 1:25, 1:33, 1:50 Inverse equal-percentage 1:25, 1:33, 1:50 Freely adjustable Setpoint function 12.SFCT 1- 25 n1 - 25 Lin 1 - 33 n1 - 33 FrEE 1 - 50 n1 - 50 Lin Setpoint turning point at 0% 5% to 95% 100% 0,0 to 100,0 % 0.0 5.0 etc. to 95.0 100.0 34.DEBA Dead band of controller Auto 0,1 to 10,0 % Auto 35.YA Start of manipulated variable limiting 0,0 to 100,0 % 0,0 36.YE End of manipulated variable limiting 0,0 to 100,0 % 100,0 13.SL0 14.SL1 usw. bis 32.SL19 33.SL20 3) (example) Customer setting WAY Degrees OFF 5 | 10 | 15 | 20 (short lever 33°) When used, the value must correspond with the set of the leverage ratio on the actuator 3.YWAY Unit Parameter values turn (part-turn actuator) WAY (linear actuator) LWAY (linear actuator without sine correction) ncSt (part-turn actuator with NCS) -ncSt (ditto, inv. direction of action) ncSL (linear actuator with NCS) Type of actuator 1.YFCT 2.YAGL Function 5) Normal means: High level without fault Inverted means: Low level without fault Display 39.YCLS Tight closing with manipulated variable Without Top only Bottom only Top and bottom no uP do uP do no 40.YCDO Value for tight closing, bottom 0,0 to 100,0 % 0,5 41.YCUP Value for tight closing, top 0,0 to 100,0 % 99,5 44.AFCT 5) None Only message Drive valve to position YA Drive valve to position YA Block movement on uP doWn StoP Function of BI 2 Without A1=min. A2=max A1=min. A2=min A1=max. A2=max Alarm function -uP -doWn -StoP NC contact -on OFF OFF -on -uP -doWn -StoP OFF OFF OFF Response threshold of alarm 1 0,0 to 100,0 % 10,0 46.A2 Response threshold of alarm 2 0,0 to 100,0 % 90,0 s Auto % Auto 5) on fault Fault + not automatic Fault + not automatic + BI ("+" means logical OR operation) normal 47. FCT Function of alarm output inverted 45.A1 Monitoring time for fault message “control deviation” Response threshold for fault message “control deviation” Auto 0 to 100 Auto 0,0 to 100,0 50. STRK Limit for stroke integral 51. DCHG Limit for direction change 52. ZERO Limit for end stop monitoring, bottom 53. OPEN Limit for end stop monitoring, top 54. DEBA Limit for dead band monitoring OFF 1 to 1.00E9 OFF 1 to 1.00E9 OFF 0,0 to 100,0 OFF 0,0 to 100,0 OFF 0,0 to 10,0 55.PRST Preset (factory setting) "no" nothing activated "Strt" start of factory setting after pressing key for 5 s "oCAY" display following successful factory setting CAUTION: preset results in "NO INI" 48. TIM 49. LIM no Strt oCAY OFF OFF % OFF % OFF % OFF A5E00074611-03 4) OFF NC contact 43.BIN2 on bLoc1 bLoc2 uP doWn StoP inverted 42.BIN1 4) None Only message Block configuring Block configuring and manual Drive valve to position YE Drive valve to position YA Block movement normal Function of BI 1 1) Parameter appears only if “turn” or “WAY” is selected; at "turn", you cannot select 33° 2) Parameter does not appear if “turn”, “LWAY” or “ncS_” has been selected with YFCT 3) Turning points only appear with selection SFCT = “FrEE” riSE NO contact MPOS riSE FALL 37.YNRM NO contact To mech. travel To flow Rising Falling MPOS FLOW 38.YDIR Standardization of manipulated variable Direction of manipulated variable for display and feedback 4) NC contact means: action with opened switch or Low level NO contact means: action with closed switch or High level Parameter name
  1. A particular slide catching your eye?

    Clipping is a handy way to collect important slides you want to go back to later.

×