Project Profile
                                             Grange Farm Primary School,
                                             Coventry
Consultant
■   IDP Midlands



Client
■   Mitie Build



Sector                         Front Entrance

■ Education



Products
■ MasterFlue System



Equipment
■ Mikrofill Ethos 90kw

                               Mikrofill Ethos Boilers

Application                    Airtherm Engineering Limited has recently completed a flue dilution
                               installation, working closely with the consultant and contractor at Grange
                               Farm Primary School, Coventry. The flue system selected for the project
■ High Efficiency Condensing   needed to be aesthetically pleasing, discreet and blend in with the building
                               features, so a dilution system was chosen over a traditional system, which
                               the client was in total agreement. Airtherm provided design calculations for
                               the project using the latest iCalc sizing package, along with compressive
                               technical submission and Auto Cad drawings for approval prior to
                               manufacture and ordering of the equipment.

                               The flue system installed comprised of a 300mm diameter fully welded
                               dilution header, flatk Woods bifurcated epoxy coated fan, stainless steel
                               silencers, volume control regulators and supply and discharge louvres,
                               situated 2m from ground level to comply with Clean Air Act Memorandum.



         0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
Product Solution

                            •     Boilers:            Mikrofill

                            •     Model:               Ethos 90kw

                            •     Application:         Flue Dilution System

                            •     Operating mode:      Wet

                            •     Pressure:            Negative / positive pressure

                            •     Working pressure: 200 Pa (product will operate 1000pa max)

Flue Dilution System        •     Inner wall:          316L Stainless Steel fully welded

                            •      Sealant :            tri-lip 'o' type silicone ring

                            •     Fuel type:            Gas



                            Considerations:
                            Airtherm can offer a fan dilution system to suit many appliances, from modern high
                            efficiency condensing to gas blown and atmospheric boilers, however the principal of
                            diluting the products of combustion is to reduce the CO² content at the discharge to
                            below 1%, CO 50ppm & NOx 5ppm (BS6644 / IGEUP/10) in line with current
                            legislation.

                            There are many design considerations that must be achieved, for instance, the
                            correct sizing of the fan unit, dilution header, inlet and discharge plenum boxes, the
Typical Flue Dilution       location to adjacent buildings, openable windows, fresh air vent pipes and final
                            discharge height. These can be found from the Clean Air Act memorandum,
                            IGEUP/10 or BS6644, along with other certain provisions with respect to the final
                            discharge height which is calculated based on the total kw input load of the plant.

                            Good Practise:
                            There are two methods that can be considered when designing the dilution system:
 Contact Details:
 Airtherm Engineering Ltd    Air is directly taken from the outside.
                             Fresh air is taken from within the plant area.
 Ventilation House
 Pedmore
                            We offer a design, supply and installation service for flue dilution systems, and can
 Stoubridge                 offer a tailored-made package to site conditions and customer requirements.
 West Midlands
 DY9 0DS


 Tel: 0844 8092509
 Fax: 01562 887312




              0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk

More Related Content

More from Andy Brown

Heat pumps & Renewables
Heat pumps & RenewablesHeat pumps & Renewables
Heat pumps & RenewablesAndy Brown
 
Commercial itchen Ventilation
Commercial itchen VentilationCommercial itchen Ventilation
Commercial itchen VentilationAndy Brown
 
Air conditioning
Air conditioningAir conditioning
Air conditioningAndy Brown
 
Natural ventilation controls brochure
Natural ventilation controls brochureNatural ventilation controls brochure
Natural ventilation controls brochureAndy Brown
 
Flues airtherm-
Flues airtherm-Flues airtherm-
Flues airtherm-Andy Brown
 
Airtherm twin wall flue systems
Airtherm twin wall flue systemsAirtherm twin wall flue systems
Airtherm twin wall flue systemsAndy Brown
 
Airtherm dwhp twin wall flue systems
Airtherm dwhp twin wall flue systemsAirtherm dwhp twin wall flue systems
Airtherm dwhp twin wall flue systemsAndy Brown
 
Press release we have moved
Press release we have movedPress release we have moved
Press release we have movedAndy Brown
 
Case study for st bernard's
Case study for st bernard'sCase study for st bernard's
Case study for st bernard'sAndy Brown
 
Case study for slough police station
Case study for slough police stationCase study for slough police station
Case study for slough police stationAndy Brown
 
Case study for elmhurst school
Case study for elmhurst schoolCase study for elmhurst school
Case study for elmhurst schoolAndy Brown
 
Airtherm flue portfolio
Airtherm flue portfolioAirtherm flue portfolio
Airtherm flue portfolioAndy Brown
 
Airtherm grilles & louvre booklet
Airtherm grilles & louvre bookletAirtherm grilles & louvre booklet
Airtherm grilles & louvre bookletAndy Brown
 
Flues & Chimney Brochure
Flues & Chimney BrochureFlues & Chimney Brochure
Flues & Chimney BrochureAndy Brown
 
Airtherm flue dilution solutions
Airtherm flue dilution solutionsAirtherm flue dilution solutions
Airtherm flue dilution solutionsAndy Brown
 

More from Andy Brown (18)

Heat pumps & Renewables
Heat pumps & RenewablesHeat pumps & Renewables
Heat pumps & Renewables
 
Commercial itchen Ventilation
Commercial itchen VentilationCommercial itchen Ventilation
Commercial itchen Ventilation
 
Air conditioning
Air conditioningAir conditioning
Air conditioning
 
Natural ventilation controls brochure
Natural ventilation controls brochureNatural ventilation controls brochure
Natural ventilation controls brochure
 
Flues airtherm-
Flues airtherm-Flues airtherm-
Flues airtherm-
 
Flue dilution
 Flue dilution  Flue dilution
Flue dilution
 
Airtherm twin wall flue systems
Airtherm twin wall flue systemsAirtherm twin wall flue systems
Airtherm twin wall flue systems
 
Airtherm dwhp twin wall flue systems
Airtherm dwhp twin wall flue systemsAirtherm dwhp twin wall flue systems
Airtherm dwhp twin wall flue systems
 
Press release we have moved
Press release we have movedPress release we have moved
Press release we have moved
 
Airtherm hvr-
Airtherm hvr-Airtherm hvr-
Airtherm hvr-
 
Case study for st bernard's
Case study for st bernard'sCase study for st bernard's
Case study for st bernard's
 
Case study for slough police station
Case study for slough police stationCase study for slough police station
Case study for slough police station
 
Case study for elmhurst school
Case study for elmhurst schoolCase study for elmhurst school
Case study for elmhurst school
 
Airtherm flue portfolio
Airtherm flue portfolioAirtherm flue portfolio
Airtherm flue portfolio
 
Flues
FluesFlues
Flues
 
Airtherm grilles & louvre booklet
Airtherm grilles & louvre bookletAirtherm grilles & louvre booklet
Airtherm grilles & louvre booklet
 
Flues & Chimney Brochure
Flues & Chimney BrochureFlues & Chimney Brochure
Flues & Chimney Brochure
 
Airtherm flue dilution solutions
Airtherm flue dilution solutionsAirtherm flue dilution solutions
Airtherm flue dilution solutions
 

Case study for grange farm primary school

  • 1. Project Profile Grange Farm Primary School, Coventry Consultant ■ IDP Midlands Client ■ Mitie Build Sector Front Entrance ■ Education Products ■ MasterFlue System Equipment ■ Mikrofill Ethos 90kw Mikrofill Ethos Boilers Application Airtherm Engineering Limited has recently completed a flue dilution installation, working closely with the consultant and contractor at Grange Farm Primary School, Coventry. The flue system selected for the project ■ High Efficiency Condensing needed to be aesthetically pleasing, discreet and blend in with the building features, so a dilution system was chosen over a traditional system, which the client was in total agreement. Airtherm provided design calculations for the project using the latest iCalc sizing package, along with compressive technical submission and Auto Cad drawings for approval prior to manufacture and ordering of the equipment. The flue system installed comprised of a 300mm diameter fully welded dilution header, flatk Woods bifurcated epoxy coated fan, stainless steel silencers, volume control regulators and supply and discharge louvres, situated 2m from ground level to comply with Clean Air Act Memorandum. 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
  • 2. Product Solution • Boilers: Mikrofill • Model: Ethos 90kw • Application: Flue Dilution System • Operating mode: Wet • Pressure: Negative / positive pressure • Working pressure: 200 Pa (product will operate 1000pa max) Flue Dilution System • Inner wall: 316L Stainless Steel fully welded • Sealant : tri-lip 'o' type silicone ring • Fuel type: Gas Considerations: Airtherm can offer a fan dilution system to suit many appliances, from modern high efficiency condensing to gas blown and atmospheric boilers, however the principal of diluting the products of combustion is to reduce the CO² content at the discharge to below 1%, CO 50ppm & NOx 5ppm (BS6644 / IGEUP/10) in line with current legislation. There are many design considerations that must be achieved, for instance, the correct sizing of the fan unit, dilution header, inlet and discharge plenum boxes, the Typical Flue Dilution location to adjacent buildings, openable windows, fresh air vent pipes and final discharge height. These can be found from the Clean Air Act memorandum, IGEUP/10 or BS6644, along with other certain provisions with respect to the final discharge height which is calculated based on the total kw input load of the plant. Good Practise: There are two methods that can be considered when designing the dilution system: Contact Details: Airtherm Engineering Ltd  Air is directly taken from the outside.  Fresh air is taken from within the plant area. Ventilation House Pedmore We offer a design, supply and installation service for flue dilution systems, and can Stoubridge offer a tailored-made package to site conditions and customer requirements. West Midlands DY9 0DS Tel: 0844 8092509 Fax: 01562 887312 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk