Project Profile
Windrush Primary School, Woolwich - London

Consultant
■

Billingford Limited

Client
■

CBM Serv Limited
...
Product Solution
•

Model:

R605

•

Application:

Chimney / Flue system

•

Operating mode:

Wet

•

Pressure:

positive ...
Upcoming SlideShare
Loading in...5
×

Flue System - Case study for Windrush School, Woolwich, London

111

Published on

Airtherm have completed the design, supply and installation of a twin wall stainless steel four hour fire rated flue systems and single wall chimney liner at Windrush School, Woolwich - London

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
111
On Slideshare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Flue System - Case study for Windrush School, Woolwich, London

  1. 1. Project Profile Windrush Primary School, Woolwich - London Consultant ■ Billingford Limited Client ■ CBM Serv Limited Sector Front Entrance ■ Education Products ■ DW & ME Equipment ■ MHS Ultragas R605 Application ■ High Efficiency Condensing Boiler Room Flues Installation of chimney liner The project involved the removal of the existing twin wall header system and the installation of a new twin wall four hour fire rated system to serve two MHS Ultragas condensing boilers. Airtherm had to undertake a CCTV survey to establish to condition of the existing chimney and to ensure the new liner would pass down the stack without any obstruction. The existing 24m high brick built chimney is lined throughout with our single wall fully welded product suitable for the application. Our experience team of fitters used a chain block to lower the sections down the stack until reaching the base, completed using a top stub termination cowl and flashing plate. 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk
  2. 2. Product Solution • Model: R605 • Application: Chimney / Flue system • Operating mode: Wet • Pressure: positive pressure • Working pressure: 150 Pa (product will operate 300pa max) • Inner wall: 316L1.4404/1.457 thickness 0,6 mm • Outer wall: 304/ 1.4301 thickness 0,5 • Insulation: 30mm thick Rockwool insulation • Sealant : Tri-lip 'o' type silicone ring • Fuel type: Gas • Chimney: Single wall fully welded stainless • Other Application our Flues can be used: • Condensing boilers • Atmospheric gas-fired boilers • Gas blown boilers • Industrial ovens, large-scale establishments • Chimney Termination MHS • Installation of chimney liner Boilers: Wood-fired stoves Contact Details: Airtherm Engineering Ltd Unit 8A, Gainsborough Trading Est Stourbridge West Midlands DY9 7ND Tel: 0844 8092509 Fax: 01384 375218 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk

×