Your SlideShare is downloading. ×
Case study for natural ventilation @ John Roan School
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Case study for natural ventilation @ John Roan School

159

Published on

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
159
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Consultant ■ Wates Construction Client ■ DMA South Ltd Sector ■ Education Products ■ Wind-iVent System Equipment ■ Natural Ventilation System Application ■ Balance Terminal 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk Project Profile John Roan School, Greenwich - London Three 1.5msqWind-iVent Systems Founded in 1677, John Roan School is one of the oldest state schools in the country, with a rich and distinguished past. Having received funding under the government’s Building Schools for the Future initiative, the School is on the cusp of opening their doors to one of the UK’s most innovative, fun and flexible learning environments. The school will boast a modern sports hall housing four badminton courts, one indoor tennis court, and a basketball and volleyball court with space for 5-a-side football. There is a separate activity studio where Zumba and dance classes can be held, which will take PE lessons to a new level at the school! The canteen will have cashless payment, which will help elevate the distress of pupils forgetting or losing money. The John Roan has been dedicated to serving the community of Greenwich for more than 335 years. With a brand new, state-of-the-art 7,600m2 building at Westcombe Park and a fully redeveloped facility at Maze Hill its is one of the largest Schools in the United Kingdom. i-Control Solutions Available Front Entrance Internal view of Hall
  • 2. Product Range The Airtherm “Wind-iVent” is a natural ventilation system operating on established aerodynamic principles. As external wind flows around the terminal itself, positive and negative pressure areas are generated. On the positive side air enters the louvres of the terminal and is directed down through the internal vanes into the room below allowing a fresh air supply to be delivered, and on the negative side the stack draws the stale unwanted air which is expelled through the terminal into the atmosphere. Installation The Wind-iVent units are lifted by a specialist crane company who work closely with our on-site engineers. The systems are mounted onto the 3mmthk aluminium fully insulated roof upstands. Each unit is fixed and secured to not only the upstand but internally using universal type fixings. Once each unit is secured a low-leakage uPVC damper and 24v actuator is fitted, followed by the insulated plenum and an internal powder coated grille to complete the system. Airtherm offer a roof plate solution for all situations, including self mount flashings and curb mount flashings with suitable upstands. The options for each project will be discussed at the design stage in detail, including the necessary openings that are required to suit our systems. 0844 809 2509 | airtherm.co.uk | info@airtherm.co.uk Product Solution Contact Details: Airtherm Engineering Ltd Unit 8A, Gainsborough Trading Est Stourbridge West Midlands DY9 7ND Tel: 0844 8092509 Fax: 01384 375218 Internal view of grille uPVC Low-Leakage Damper The features and advantages of such a system: ☼ A fresh air supply for workers - proven to increase productivity & reduce staff sickness ☼ Naturally ventilated - reduce your energy costs and carbon footprint without the need for mechanical ventilation ☼ Night time purge of stale air - creating a fresh working environment for staff the following morning ☼ Better control of building temperature and CO² levels ☼ Free cooling ☼ Easy to use Stand-alone control solution Controller C/w C 02 & Temp 99.7% rain rejection - Class ‘A’ Louvre

×