Your SlideShare is downloading. ×
  • Like
Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co.
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Now you can save presentations on your phone or tablet

Available for both IPhone and Android

Text the download link to your phone

Standard text messaging rates apply

Water Closet Supports Sales Presentation by Jay R. Smith Mfg. Co.

  • 1,000 views
Published

It takes time to build a reputation. That's why Jay R. Smith Mfg. Co.® has devoted more than 85 years to engineering and manufacturing products to the high standards our customers have learned to …

It takes time to build a reputation. That's why Jay R. Smith Mfg. Co.® has devoted more than 85 years to engineering and manufacturing products to the high standards our customers have learned to expect. We work each day to find a way to
make these products better. The Adjustable Linebacker® Fixture Support with Waste Fitting is an example of one for our many professional grade products.

For more information, please visit www.jrsmith.com.

Published in Education , Business , Technology
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
1,000
On SlideShare
0
From Embeds
0
Number of Embeds
1

Actions

Shares
Downloads
9
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. Sales Presentation Water Closet Supports
  • 2.
    • The Problem Page 3
    • The Solution Page 4
    • Benefits of Off-The-Floor Water Closet Supports Page 5
    • Water Closet Support Features Page 6
    • Water Closet Overview Page 7
    • Water Closet Support Battery Prefabrication Page 8
    • Optional Accessories Page 9-10
    • How to Select a Water Closet Page 11
    • Suggested Specifications Page 12
    • Applications Page 13
    • Certifications/Listings Page 14
    • Summary Page 15
    • Questions Page 16
    Agenda
  • 3. The Problem
    • Public Restrooms can present a source of problems and extra expense to maintain and keep clean.
    • Architects and engineers are concerned with controlling building costs and ensuring structurally sound designs by selecting proper water closet supports.
    • Contractors are looking for products that allow them to save time and reduce installation costs during construction.
    • Customers insist on the best value for their investment and expect a high level of sanitation.
  • 4. The Solution
    • Off-The-Floor water closet supports for various installation applications.
    • Labor saving water closet supports for battery prefabrication.
    • Application versatility for metal stud, block or narrow wall chase configurations.
    • Reduced maintenance and cleaning costs.
  • 5. Benefits of Off-The-Floor Water Closet Supports
    • Fixture supports available for Off-The-Floor water closets.
    • Off-The-Floor water closet systems can be installed more economically than conventional floor mounted systems.
    • Less Sleeving. In most cases only one sleeve is required to take care of the vertical inlet fitting at the start of the horizontal run.
    • Since all the roughing is done on the floor and not in the ceiling below, no scaffolding, ladders or similar supports are required.
    • The installer works on the floor and not in the ceiling below; time is saved since working conditions are more favorable.
    • Because all the rough-in piping is on the floor above, “dropped ceilings” are not required; ceiling space is saved. This enables building ceiling height to be lower, effectively saving overall construction costs.
  • 6. Typical Smith Fixture Support with Waste Fitting LINEBACKER ® Figure 0210RY Horizontal No-Hub Right Hand Single Fitting Water Closet Support Features Rear Support lug __ –M51 Anchor Foot (regularly furnished ) Face Plate Gasket Face Plate Bolts & Washers 4” Connection (NO-HUB) Waste Fitting with 2” NO-HUB Offset Vent Face Plate Nuts Fixture Studs Face Plate Base Supports Base Support Bolts and Washers ABS Nipple ABS Adjust-To-Wall Coupling with Knockout Test Cap Outlet Gasket Fixture Bearing Nuts & Washers Fixture Cap Nuts Fixture Washers-Fiber
  • 7. 9” (230) 7 ½” (190) 4 ¼” (110) Min 9” (230) Max Cut Off Tab 18 ¼” (465) Front View 4” (100)
    • Adjustable horizontal and vertical fitting supports to fit various installation requirements.
    Water Closet Support Overview Figure 0210, 0220
    • Wide range of applications from metal stud to block walls.
    • Water closet supports designed to fit in wall chase from 12” to 18”.
    • Available with no-hub connection.
  • 8. Water Closet Battery Prefabrication
    • -M54 Side Mounted Leg
    • Symmetric construction
    • Increased load bearing capability
    • One bolt per leg allowing faster and easier prefabrication
    • -M54-M58 Faceplate with “O” Ring Seal
    • Integral adjustable wall coupling, nipple and test cap
    • Adjustment at the faceplate rather than at the rear of the water closet (coupling)
    • 10 inch-long nipple covers various installations
    • Enhanced sealing with an o-ring at the faceplate
    0200 Water Closet Support series time and labor saving features allow for easy battery prefabrication.
    • ½ “ incremental markings for quick rough-in
  • 9. Suffix –M12 Exposed Flush Valve Supply Support – The M12 support has been redesigned to provide greater strength and ease of installation. The stronger (3/16”) angle clip and more rigid stud make the M12 a great alternative to competitive products like the HoldRite Support. Optional Accessories Suffix –M13 Tiling Frame – The purpose of this frame is to provide a rim for a flat even surface for the tiler to work to when he is applying the finished wall tile. Available for siphon jet closets only. Suffix –M50 Elevated Support Base – For double (back-to-back) installations which require a single elevated water closet, the –M50 variation may be used with all regular Smith adjustable or compact supports. The –M50 is particularly adaptable to hospital or nursing home applications where a single water closet is installed on the stack at each floor. Not recommended for battery installations. Suffix –M40 Water Closet Support For Wide Pipe Chase - When the “C” dimension exceeds 7”, the –M40 Wide Pipe Chase Support should be used. This accessory provides a set of feet directly behind the wall for extra rigidity and an alignment yoke to ensure proper alignment of the nipple. The M-40 may be used with any vertical or horizontal fixture support in single or double (back-to-back) installations. Specify “C” dimensions when ordering C
  • 10. Suffix –M54 Face Plate with side Mounted Base Support Assembly – Front View Top View A concealed flush valve will not clear the face plate when used with a blowout water closet support . Therefore 4 ½” to 6 ½” is required from back of wall to face plate to permit the installation of the concealed flush valve piping. Optional Accessories cont. Suffix –M17 Water Closet Setting Gauge – The Gauge has the same dimensions as the rear of the “Off The Floor” siphon jet bowl and is designed to eliminate costly trial and error test mounting and reduce the number of bowl “lifts” per day. Concealed Flush Valves – For most siphon jet water closets with concealed flush valves, the supply pipe enters the rear of the water closet above the top of the face plate without interference. Concealed flush valve piping in all cases does not interfere with the vent connection of the fitting. Siphon Jet Blowout 4 ½” – 6 ½”
  • 11. Piping For Floor Mounted Fixtures Piping for Off-The- Floor Fixtures
    • Determine if the Fixture will be Floor Mounted or Off-the-Floor.
    • Determine if a Siphon Jet or Blowout Water Closet is best for the application .
    How to Select a Water Closet
    • Review the Battery Installation.
    • Select Vertical Fitting with Side Inlets.
    Left Hand Right Hand Vent Stack
    • Determine Left or Right Hand Horizontal Fittings
    • Select the Face Plate.
  • 12.
    • Wall Hung Siphon Jet Water Closet Supports – Smith No. 0200 series adjustable shallow rough-in support for one-pour floor construction. Where two-pour construction is required, Smith No. 0100 series adjustable deep rough-in support may be used. Where furred wall space is not sufficient for the adjustable series, Smith “compact” No. 0400 series may be used.
    • Wall Hung Blowout Water Closet Supports – Smith No. 0300 series “adjustable” rough-in support. Where furred wall space is not sufficient for the adjustable series, Smith “compact” No. 0400 series may be used.
    • Wall Hung Residential Water Closet Supports Floor-Mount Type – Smith No. 0550F series siphon jet supports with waste fitting and extra heavy cast iron face plate. Combined face plate and closet support shall be securely bolted to floor construction. When back-to-back bowls are specified, use No. 0550FD series.
    • Wall Hung Residential Water Closet Supports Stud-Mount Type – Smith No. 0550 series stud-mount siphon jet support with waste fitting and adjustable steel face plate with steel reinforcing strap of design which transmits all top fixture stud-bolt loading to interior wall construction and bottom fixture stud-bolt loading to sole plate. When back-to-back bowls are specified, use No. 0550D series.
    • Floor Mounted Back Outlet Water Closet Fittings – Smith No. 0200 or 300 adjustable series fixture supports with type No. 2 outlet connection. Where furred wall space is not sufficient for the adjustable series, Smith “compact” No. 0400 series or Smith No. 0670 thru 0680 waste fitting assembly with Type No. 2 closet outlet connection may be used.
    Suggested Specifications
  • 13. Applications Water closet supports for various installations Horizontal Adjustable Carriers Double/Metal stud wall Single/Metal stud wall Double/Block wall Single/Block wall Vertical Adjustable Carriers Double/Metal stud wall Single/Metal stud wall Double/Block wall Single/Block wall Vertical Fixed Carriers Double/Metal stud wall Single/Metal stud wall Double/Block wall Single/Block wall
  • 14. IAPMO Listed – File #1618 Conforms to ASME – A112.6.1M Certifications/Listings
  • 15. Summary
    • Off-The-Floor Water Closet Supports save time and reduce installation costs.
    • Off-The-Floor Horizontal Water Closet Supports provide installation versatility for battery prefabrication.
    • Off-The-Floor fixtures reduce maintenance and cleaning costs while improving toilet room sanitary conditions.
    • Fixture supports available for all major Off-The-Floor Water Closet models/manufacturers.
    • Adjustable horizontal and vertical fitting supports to fit various installation requirements.
    • Wide range of applications from metal stud to block wall to narrow wall chase.
  • 16. Questions?
  • 17. For more information on this or other products, or to contact your local Jay R. Smith Mfg. Co. representative, please visit our website at www.jrsmith.com Thank You!