Clique solar & ARUN Solar Concentrator

946
views

Published on

Published in: Technology, Business

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
946
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
70
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Clique Solar & ARUN® Off-grid Solar Thermal ApplicationsCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 2. Crude Oil caters to one fourth of India’sprimary energy Nuclear Hydro Renewables 1% 2% 1% Biomass 24% Coal 41% Crude Oil 26% Natural Gas 5% Source : IEA, 2008Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 3. India imports 80% of its oil consumption 3500 3000 Consumption Thousand Barrels per Day 2500 2000 1500 Production 1000 500 2000 2002 2004 2006 2008 2010 2012 YearCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 4. Why Solar Thermal in IPH sector? ~20% of this oil is used in industries in thermal form at temperatures below 300°C 30% of this can be replaced by solar energy resulting in: Reducing a country’s Forex burden Imparting energy security Emission reduction of Carbon dioxide as well as other pollutantsCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 5. Energy Distribution of solar energy Outer Space reaching earth’s surfaceSolar Radiation Reflection Losses Earth’s Atmospheric Layer Scattering (200 W/m2) Absorption (250 W/m2) (H20, CO2, Ozone , Aerosols) Diffuse Radiation from Beam or Direct scattering (200 W/m2) RadiationCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 6. Technologies to capture Solar EnergyCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 7. Concentrating Optics Parabolic Focus ReflectorCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 8. Concentrators Parabolic rotational solids Extruded parabolic profiles Concentrate the irradiance Concentrate the irradiance up to 2,000 times up to 200 times 8Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 9. Fresnel Concentrators 9Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 10. Concentrator Solar Power Technologies Dish Systems 5 – 25 kWe Off-grid / long-term pilot plants Solar Tower Systems 5 – 100 Mwe Pilot power plants Parabolic Trough 5 – 200 Mwe Power Plants Linear Fresnel 5 – 200 MWe Pilot Power Plants 10Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 11. About Clique Solar Pioneer in developing solar thermal technologies for off- grid applications Developed the innovative ARUN® Solar Concentrator It is a channel partner for MNRE Boasts of both R&D and Engineering skills Clique Solar saves an equivalent of 1,000 liters of furnace oil per day!Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 12. ARUN® Solar Concentrator – at a glance Output per day, on a clear sunny day Application By 1 ARUN®160 By 1 ARUN®100 Dry Saturated Steam 1200 kg 700 kg Hot Water 25,000 liters 15,000 liters Cooling 25 TR for 8-10 hours 15 TR for 8-10 hours Cooking 7,500 meals 4,500 meals Milk Pasteurization 30,000 liters 18,000 liters Effluent evaporation 2.5m3 1.5m3 Laundry 600 kg 350 kgCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 13. ARUN® Technology Paraboloid Fresnel mirror arrangement Focus is a point Automatic two axis tracking Integration with existing system Optimization of integrationCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 14. ARUN® Technology –Fresnel Mirror Arrangement 2D fresnel parabolaCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 15. ARUN® Technology –Fresnel Mirror Arrangement Absorber at focal point Reflected Sun Rays Sun rays 2D fresnel parabolaCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 16. ARUN® Technology –Automatic 2-axes tracking system Aperture areas always faces the sun DNI is captured in full (no cosine loss)Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 17. ARUN® Technology –Integration with existing system Steam for process heat applications Steam Drum PumpCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 18. ARUN Applications Industrial Hospitality Comfort Community Residential Sectors Sector Cooling Cooking sector Industry Working Fluids Temperature Range Pharmaceutical Industry Steam, Air 80°C - 230°C Textile industry Water, Steam 60°C - 150°C Chemical Industry Steam, Air 80°C - 320°C Pulp & Paper Industry Steam Up to185°C Food Industry Steam, Air 80°C - 280°C Mechanical Industry Water, Steam 60°C - 150°C Automobile Industry Water, Steam 60°C - 200°CCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 19. ARUN Applications Industrial Hospitality Comfort Community Residential Sectors Sector Cooling Cooking sector Process Working Fluids Temperature Range Laundry Steam 150°C - 180°C Cooking Steam 120°C - 280°C Cleaning, Bathing Water 50°C - 65°CCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 20. ARUN Applications Industrial Hospitality Comfort Community Residential Sectors Sector Cooling Cooking sector The thermal energy of solar radiation to power thermally driven cooling machines (VAM: Vapour Absorption Machine) Load and Load Pattern (Time of Load) matching between cooling loads and solar radiation needed HVAC (Heating, Ventilation, and Air Conditioning) networks contribute over 30% of a building energy usageCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 21. ARUN Applications Industrial Hospitality Comfort Community Residential Sectors Sector Cooling Cooking sector Cooking load and pattern matching needed Different cooking items require different temperatures Heat required for Temperature Item Per meal intake cooking required Rice – 100gm Rice, Dal, Veg Dal – 50gm 85-90 kcal / meal 120°C Vegetable – 50gm (dry weight) 25gm per chapatti, 2 chapaties ~50kcal / chapatti, OR Chapattis ~280°C per meal 100kcal / meal Hot water, 200ml equivalent 50 kcal / day ~100°C milk, etcCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 22. ARUN Applications Industrial Hospitality Comfort Community Residential Sectors Sector Cooling Cooking sector Process Working Fluids Temperature Range Bathing & washing Water 40°C- 60°C Kitchen – utensil washing Water 40°C- 60°CCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 23. ARUN Installations Government of India, Solar Steam Generating System for Heavy Water Board Heavy Water Plant of Department of Atomic Energy at Kota Pressurized Hot Water Generating System at M/s. Mahindra Vehicles Manufacturers Limited, Pune Solar Steam Generating System for Dairy Applications at M/s. B. G. Chitale Dairy, Sangli Pressurized Hot Water Generating system for Maharashtra Rajya Sahakari Dudh Mahasangh Maryadit (Mahanand Dairy) at Latur unit Solar Steam Generating System for Hospitality Applications at Hotel ITC Maurya, Delhi Pressurized Hot Water Generating System at M/s. Turbo Energy Ltd., Paiyanoor, Chennai Steam Generating System at NTPC’s Research Arm (NETRA) in Greater NoidaCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 24. Case Study 1 – Mahanand Dairy (running 100% on solar) Pressurized Hot Water for Milk Pasteurization with storage Location Latur Delivery 18 bar and 180˚C Capacity 80 – 100 kWth per dish Dish numbers 1 dish Commissioning February 2006Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 25. Case Study 2 – Heavy Water Board, Kota Steam for Effluent Evaporation Location Kota Delivery 5 bar and 150˚C Capacity 80 – 100 kWth per dish Dish numbers 4 dishes Commissioning March 2010Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 26. Case Study 3 – Turbo Energy Limited Pressurized Hot Water for Comfort Cooling Location Chennai Delivery 15 bar and 180˚C Capacity 80 – 100 kWth per dish Dish numbers 2 dishes Commissioning March 2011Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 27. Case Study 4 – ITC Maurya, New Delhi Steam for Hospitality applications like Laundry, Cooking, Bathing Location Delhi Delivery 8 bar (g) and 175˚C Capacity 80 – 100 kWth per dish Dish numbers 2 dishes Commissioning Nov 2009Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 28. Case Study 5 – Mahindra & Mahindra Pressurized Hot Water for Degreasing Process Location Pune Delivery 18 bar and 180˚C Capacity 80 – 100 kWth per dish Dish numbers 1 dish Commissioning October 2010Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 29. Case Study 6 – Chitale Dairy Steam Generation for Milk Pasteurization Location Sangli Delivery 5 bar and 152˚C Capacity 80 – 100 kWth per dish Dish numbers 2 dishes Commissioning October 2009Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 30. Case Study 7 – Temple at New Delhi Steam Generation for community cooking (under construction) Location New Delhi Delivery 6 bar and 160˚C Capacity 48 – 60 kWth per dish Dish numbers 1 dish Commissioning June 2012Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 31. Case Study 8 – Residential sector Hot water generation for domestic purpose (under construction) Location Pune Delivery 60˚C Capacity 48 – 60 kWth per dish Dish numbers 1 dish Commissioning June 2012Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 32. ARUN® - Key Features Small Footprint Area & Retrofits: The small footprint area of ARUN® dish (3m x 3m per dish) enables it to be mounted at locations which have space limitations. It can also be erected on rooftops of existing buildings. Performance Guarantee: Clique Solar guarantees the performance characteristics of ARUN® dish. Highest Temperature & Pressure Delivery: ARUN® can operate up to 400°C (oil) and 25 bar (steam). Government Subsidy: MNRE provides support by way of capital subsidy or soft loans for every ARUN® installation.Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 33. ARUN® - Key Features Non-Solar Hours Operations: ARUN® dish can be augmented with a heat energy storage facility for operation in non‐solar hours. IBR Approval: ARUN® is the first IBR approved Solar Boiler in India. High Wind Bearing Capacity: ARUN® dish is designed to operate in wind speeds up to 10 m/s and it can survive in wind speeds up to 45 m/s.Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 34. ARUN® withstands high wind speeds Wind Blowing at Storm (Wind at 170 km/hr) 43 km/hr Concrete column with foundationCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 35. ClientTestimonialsCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 36. ClientTestimonialsCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 37. ARUN Economics Attractive investment economics Simple Equity payback in less than 2 years Accelerated Depreciation at 80% of residual asset value Subsidy of Rs. 10L per dish Sector specific economic indicators Cost per kcal of energy delivered over the lifetime Energy gain ratio (25 to 30) Foot-print area (3m x 3m including integration) Need to view this as an infrastructure investment – life is 25-30 years+Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 38. Annual Cash Flows Year 0 Investment in -50 ARUN system Capital Subsidy 10 Loan 28Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 39. Annual Cash Flows Year 0 Investment in -50 ARUN system Capital Subsidy 10 Loan 28 Tax saved due to 10.9 Acc. DepreciationCopyright © 2012 Clique Developments Limited.All rights reserved.
  • 40. Annual Cash Flows Year 0 Investment in -50 ARUN system Capital Subsidy 10 Loan 28 Tax saved due to 10.9 Acc. Depreciation Net Cash flow -1.1Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 41. Annual Cash Flows Year 0 Year 1 Investment in -50 ARUN system Capital Subsidy 10 Loan 28 Annual Fuel 8.0 Savings (derated) O&M expense 0.0 Debt Repayment -4.7 Interest Expense -4.2 @ 15% Tax saved due to 10.9 2.2 Acc. Depreciation Net Cash flow -1.1 1.3Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 42. Annual Cash Flows Year 0 Year 1 Year 2 Investment in -50 ARUN system Capital Subsidy 10 Loan 28 Annual Fuel 8.0 8.8 Savings (derated) O&M expense 0.0 -1.0 Debt Repayment -4.7 -4.7 Interest Expense -4.2 -3.5 @ 15% Tax saved due to 10.9 2.2 0.4 Acc. Depreciation Net Cash flow -1.1 1.3 0.1Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 43. Annual Cash Flows Year 0 Year 1 Year 2 Year 3 Year 4 Year 5 Year 6 Year 7 Investment in -50 ARUN system Capital Subsidy 10 Loan 28 Annual Fuel 8.0 8.8 9.7 10.6 11.7 12.9 14.2 Savings (derated) O&M expense 0.0 -1.0 -1.1 -1.2 -1.3 -1.5 -1.6 Debt Repayment -4.7 -4.7 -4.7 -4.7 -4.7 -4.7 0.0 Interest Expense -4.2 -3.5 -2.8 -2.1 -1.4 -0.7 0.0 @ 15% Tax saved due to 10.9 2.2 0.4 0.1 0.0 0.0 0.0 0.0 Acc. Depreciation Net Cash flow -1.1 1.3 0.1 1.2 2.7 4.3 6.1 12.6Copyright © 2012 Clique Developments Limited.All rights reserved.
  • 44. For more information, contact us at: E: sales@cliquesolar.com W: www.cliquesolar.com P: +91-22-2860 9011Copyright © 2012 Clique Developments Limited.All rights reserved.