• Share
  • Email
  • Embed
  • Like
  • Private Content
YSI Advancements in Monitoring & Control Technology Webinar 1213
 

YSI Advancements in Monitoring & Control Technology Webinar 1213

on

  • 10,235 views

Webinar covering product advancements that improve system performance, productivity and efficiency with M&C water quality technology. ...

Webinar covering product advancements that improve system performance, productivity and efficiency with M&C water quality technology.

Topics include:
• optical based dissolved oxygen
• connectivity/networking options
• automated feeding with YSI Feed Smart
• data management with AquaManager and the AquaViewer App
• alarming options

Applications for M&C systems include tank-based/RAS commercial aquaculture, aquaculture research, live haul, public aquariums, algae culture and anyone interested in aquaculture monitoring and control technology to improve performance, productivity and efficiency.

Statistics

Views

Total Views
10,235
Views on SlideShare
1,253
Embed Views
8,982

Actions

Likes
0
Downloads
13
Comments
0

15 Embeds 8,982

http://www.ysi.com 7052
http://www.scoop.it 1496
http://blog.ysi.com 362
http://translate.googleusercontent.com 28
https://twitter.com 20
http://img.scoop.it 5
http://131.253.14.98 5
http://131.253.14.66 3
http://www.linkedin.com 3
http://myysi.tumblr.com 2
https://translate.googleusercontent.com 2
http://www.myysi.tumblr.com 1
http://webcache.googleusercontent.com 1
http://www.google.co.th 1
https://www.google.co.in 1
More...

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    YSI Advancements in Monitoring & Control Technology Webinar 1213 YSI Advancements in Monitoring & Control Technology Webinar 1213 Presentation Transcript

    • YSI Aquaculture Monitoring & Control Technologies
    • Outline of Topics  Product Line Overview  Sensor Options  Dissolved Oxygen Technology  Redundancy, System Security and Flexibility  Integration with other Devices  Feed Smart  Alarming  Communication and Remote Data Options  AquaManager Desktop Software  AquaViewer App © 2013 YSI Incorporated
    • Models 5200A, 5400 and 5500D (M&C) ysi.com/5200A ysi.com/5400 ysi.com/5500D Multiparameter; DO, pH, Cond, Salinity, ORP (Redox), Temp. 5200A-AC or DC © 2013 YSI Incorporated Multichannel (4) DO 5400-AC or DC Multichannel (1 to 4) optical DO 5500D-01-AC or DC 5500D-02-AC or DC 5500D-04-AC or DC
    • Sensor Options Standard  Multiparameter; dissolved oxygen, conductivity, pH, ORP (Redox) and temperature  Dissolved Oxygen; electrochemical (galvanic or polarographic) and optical dissolved oxygen sensors Auxiliary  Any sensor with digital or an analog output; 420ma, 0-1 VDC, 0-5 VDC • • • • • Flow Level CO2 Ozone UV Transmittance © 2013 YSI Incorporated Optical Dissolved Oxygen Multiparameter Galvanic Dissolved Oxygen
    • ProODO® Probe Temperature sensor © 2013 YSI Incorporated Sensor Cap with ≈ 12 to18 month life
    • Measuring Dissolved Oxygen Optically Oxygen is constantly moving through the Diffusion Layer, affecting the luminescence of the sensing layer. The lifetime of the luminescence is measured by the sensor and compared against the reference. © 2013 YSI Incorporated The amount of oxygen passing through the sensing layer is inversely proportional to the lifetime of the luminescence in the sensing layer.
    • Flow Dependence Flow Stopped © 2013 YSI Incorporated
    • Flow Dependence Continued Flow Stopped © 2013 YSI Incorporated
    • Optical Dissolved Oxygen Advantages Optical Dissolved Oxygen Technology can save you $$$ Higher accuracy • No stirring/flow required to achieve accurate measurements • Maintain healthy levels of O2 while saving on aeration and/or oxygen costs Low maintenance • No electrodes to clean • No regular membrane changes • Extremely stable long term so no need for frequent calibrations  Not affected by Hydrogen Sulfide or other gasses © 2013 YSI Incorporated
    • Redundancy, System Security and Flexibility  Measurement and control functions managed at the instrument level. No risk of complete network/system failure.  Password protected functions  Tank side display for easy use and calibration  AC units automatically switch to DC backup power when AC mains power goes down. An Email or SMS message will be sent.  Alarms on loss of networked slave devices  Fully user configurable and scalable – fits any operation without custom programming and can be easily modified by the user as their needs change. © 2013 YSI Incorporated
    • YSI M&C and PLC Systems  YSI M&C products can be easily integrated into systems using PLCs via RS-232 or Ethernet communication.  A hybrid approach - the YSI M&C product performs some process control and some process control is performed by the PLC.  Allows the integrator or customer to develop their own custom software solution if desired. © 2013 YSI Incorporated
    • Feed Smart™ Conditional Feed Timer Manages feed delivery:  Simple, one-step calibration process  Up to 100 feedings per day  Decrease feed amount by user defined % based on DO and Temperature values (also, pH values on the 5200A)  Increases feed amount on a daily basis by user defined FCR bit.ly/FeedSmart © 2013 YSI Incorporated
    • Feed Smart™ Conditional Feed Timer Example Calculation Chart Day 1 Feed % of Biomass (user entered value) Day 2 Day 3 Day 4 Day 5 Day 6 Day 7 4.00% 4.00% 4.00% 4.00% 4.00% 4.00% 4.00% 2500.0 2566.7 2635.1 2705.4 2777.5 2851.6 2927.6 Daily Feed Amount (system calculated) 100.0 102.7 105.4 108.2 111.1 114.1 117.1 Cumulative Feed Amount (system calculated) 100.0 202.7 308.1 416.3 527.4 641.5 758.6 Biomass (enter beginning value only) FCR Factor x.x to 1.0 (user entered value) 1.5 Make FCR a decimal (system calculated) 0.67 Increase in Biomass (system calculated) 66.7 68.4 70.3 72.1 74.1 76.0 78.1 Cumulative Biomass Increase (system calculated) 66.7 135.1 205.4 277.5 351.6 427.6 505.7 2566.7 2635.1 2705.4 2777.5 2851.6 2927.6 3005.7 Calculated New Biomass bit.ly/FeedSmart © 2013 YSI Incorporated
    • Alarms General Alarm Ability to configure a single relay to control light or siren based on any alarm condition Alarm Conditions  Parameter out of range  Power outage; loss of AC power and low DC voltage  Loss of slave  Loss of ODO communication Alarm Hold Off  When enabled, acts as a filter for false alarms © 2013 YSI Incorporated
    • Alarms E-mail and SMS Alarming tgrooms@ysi.com Date: Wed 04 Dec 2013 18:10:46 Subject: AutoPoller Alarm Message YSI5200A Alarm Tilapia Tank #1 DO Low Alarm: 4.50 mg/L © 2013 YSI Incorporated
    • Networking and Communication Options © 2013 YSI Incorporated
    • Networking and Communication Options © 2013 YSI Incorporated
    • Networking and Communication Options © 2013 YSI Incorporated
    • Networking and Communication Options © 2013 YSI Incorporated
    • AquaManager Software Data Management  Graphing  Data export  Event logging  Manual data entry System Management  Explorer based network setup and support  E-mail and SMS setup  Set-point and control management © 2013 YSI Incorporated
    • Mapping Screen • Gives a quick visual of the entire operation • Images include animations • Easy for user to set up © 2013 YSI Incorporated
    • Event Logging © 2013 YSI Incorporated
    • Event Logging © 2013 YSI Incorporated
    • AquaViewer Apple Device App • iPhone • iPad • iPod Touch (generation #3 or higher) Set up screen #1 © 2013 YSI Incorporated Set up screen #2 Network Viewer screen: • Normal • Control in yellow • Alarms in red Instrument Viewer screen: • Normal in green • Control in yellow • Alarms in red
    • Wrap Up So, why choose YSI?  Proven and trusted technology  Global presence  Provide solutions that make you more productive  Professional support © 2013 YSI Incorporated
    • Questions? © 2013 YSI Incorporated