“All south facing” 2DK TShel2<br />Plan, elevation and perspective view of Single, Triplex and Sixplex configurations<br />
Single unit plan views<br />Dimensions in mm<br />First floor view on the left.  <br />Second floor view on the right<br />
Single unit Elevation views<br />Dimensions in mm<br />South view on the right<br />East view on the left.  <br />
Single housing unit Perspective views, first floor<br />
Single housing unit Perspective views, Second floor<br />
Triplex plan views<br />First floor on the left<br />Second floor on the right<br />Note: the “East”, “Middle” and “West” ...
Triplex Elevation views<br />South view on the left<br />East view on the right<br />
Triplex perspective views<br />South view on the left<br />North view on the right<br />
sixplex plan views<br />First floor on the left<br />Second floor on the right<br />
sixplex Elevation views<br />South view on the left<br />East view on the right<br />
sixplex perspective views<br />South view on the left<br />North view on the right<br />
Sample sections of 2DK tshel2<br />FOR REVIEW AND DISCUSSION OF INSULATION AND INTERIOR PANELS<br />
EXTERIOR WALL SECTION, WITH INTERIOR INSULATION AND mdf PANEL<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Exterior panel:...
EXTERIOR WALL SECTION, SHOWING INTERIOR mdf PANEL<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Exterior panel: SmartSide 7...
Lower floor SECTION, SHOWING vinyl flooring<br />Floor joists: 6” x 1-5/8” x 18ga<br />Sub-floor: ½” Plywood FR JAS-stampe...
Upper floor SECTION, SHOWING carpet tiles<br />Floor joists: 6” x 1-5/8” x 18ga<br />Sub-floor: ½” Plywood FR JAS-stamped<...
Roof SECTION, SHOWING Fibreglass asphalt shingles<br />Roof rafters: 6” x 1-5/8” x 18ga<br />Overlay: ½” Plywood FR JAS-st...
Interior separation / shear WALL SECTION, (Between housing units)<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Shear panel...
Interior bearing WALL SECTION, (central wall, both floors)<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Rigid interior pan...
Upcoming SlideShare
Loading in …5
×

2 dk t shel2 all south facing 20110522

17,850 views
17,789 views

Published on

CAD images of the 2DK TShel2

Published in: Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
17,850
On SlideShare
0
From Embeds
0
Number of Embeds
6
Actions
Shares
0
Downloads
5
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

2 dk t shel2 all south facing 20110522

  1. 1. “All south facing” 2DK TShel2<br />Plan, elevation and perspective view of Single, Triplex and Sixplex configurations<br />
  2. 2. Single unit plan views<br />Dimensions in mm<br />First floor view on the left. <br />Second floor view on the right<br />
  3. 3. Single unit Elevation views<br />Dimensions in mm<br />South view on the right<br />East view on the left. <br />
  4. 4. Single housing unit Perspective views, first floor<br />
  5. 5. Single housing unit Perspective views, Second floor<br />
  6. 6. Triplex plan views<br />First floor on the left<br />Second floor on the right<br />Note: the “East”, “Middle” and “West” units are the three unique housing units for any number of multi-plexof the “all-south-facing” configuration.<br />
  7. 7. Triplex Elevation views<br />South view on the left<br />East view on the right<br />
  8. 8. Triplex perspective views<br />South view on the left<br />North view on the right<br />
  9. 9. sixplex plan views<br />First floor on the left<br />Second floor on the right<br />
  10. 10. sixplex Elevation views<br />South view on the left<br />East view on the right<br />
  11. 11. sixplex perspective views<br />South view on the left<br />North view on the right<br />
  12. 12. Sample sections of 2DK tshel2<br />FOR REVIEW AND DISCUSSION OF INSULATION AND INTERIOR PANELS<br />
  13. 13. EXTERIOR WALL SECTION, WITH INTERIOR INSULATION AND mdf PANEL<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Exterior panel: SmartSide 7/16” engineered wood shear panel*<br />Insulation and vapor barrier: P1000 EPS and radiant barrier panels<br />Rigid interior panel: ¼” MDF FR (no formaldehyde) painted<br />*Note: no grooves in SmartSide panels to be used in 2DK TShel2<br />
  14. 14. EXTERIOR WALL SECTION, SHOWING INTERIOR mdf PANEL<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Exterior panel: SmartSide 7/16” engineered wood shear panel<br />Insulation and vapor barrier: P1000 EPS and radiant barrier panels<br />Rigid interior panel: ¼” Medium Density Fibreboard (MDF) FR painted<br />
  15. 15. Lower floor SECTION, SHOWING vinyl flooring<br />Floor joists: 6” x 1-5/8” x 18ga<br />Sub-floor: ½” Plywood FR JAS-stamped<br />Insulation and vapor barrier: P1000 EPS and radiant barrier panels<br />Rigid flooring surface: ¼” Plywood FR JAS-stamped<br />Flooring: 1/16” vinyl (for kitchen and bathroom areas)<br />
  16. 16. Upper floor SECTION, SHOWING carpet tiles<br />Floor joists: 6” x 1-5/8” x 18ga<br />Sub-floor: ½” Plywood FR JAS-stamped<br />Flooring: Carpet tiles (for living room and bedroom areas)<br />1st floor ceiling (on bottom of section): ¼” MDF panel, painted<br />
  17. 17. Roof SECTION, SHOWING Fibreglass asphalt shingles<br />Roof rafters: 6” x 1-5/8” x 18ga<br />Overlay: ½” Plywood FR JAS-stamped<br />Roofing: Class A Fire Rated fibreglass asphalt shingles with underlayment<br />Insulation: P1000 1” rigid panel radiant barrier (superior to 6” glasswool)<br />2nd floor ceiling (on bottom of section): ¼” MDF panel, painted<br />
  18. 18. Interior separation / shear WALL SECTION, (Between housing units)<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Shear panel: ½” Plywood FR JAS-stamped<br />Insulation and vapor barrier: P1000 1” EPS and radiant barrier panels<br />Rigid interior panels both sides: ¼” MDF FR (no formaldehyde) painted<br />
  19. 19. Interior bearing WALL SECTION, (central wall, both floors)<br />Wall studs: 3-5/8” x 1-5/8” x 18ga<br />Rigid interior panels both sides: ¼” MDF FR (no formaldehyde) painted<br />

×