Fluid Mechanics II     Lecture 9 Muhammad Usman
Airfoil Theory• Angle of inclination depends on the geometerical  position of the body with respect to motion.• Flat plate...
Reciprocating Pump• L=Length of the stroke• A= Cross sectional Area• N= No. Of revolutions per mint.• Discharge of Water= ...
Slip of Pump• The difference between actual and  theoretical discharge is known as slip of  the pump.• Force on the piston...
Indicator Diagram
Variation of Pressure In section  and Delivery pipes due to  acceleration of the piston
Effect of Acceleration on the     Indicator Diagram
Example 1• A single acting reciprocating pump has a  plunger of diameter 300mm and stroke of  200 mm. If the speed of the ...
Example 2• A single acting reciprocating pump, having  plunger diameter 125 mm and stroke  length 300 mm is drawing water ...
Upcoming SlideShare
Loading in …5
×

Lecture 9

576 views
530 views

Published on

Published in: Health & Medicine, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
576
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
7
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Lecture 9

  1. 1. Fluid Mechanics II Lecture 9 Muhammad Usman
  2. 2. Airfoil Theory• Angle of inclination depends on the geometerical position of the body with respect to motion.• Flat plate inclined at 4 the ratio of lift to drag force is about 6. To increase this ratio• The plate is given a slight curvature in its bottom• By nicely rounding off the front end of the plate• Providing sharpe edge in the end.
  3. 3. Reciprocating Pump• L=Length of the stroke• A= Cross sectional Area• N= No. Of revolutions per mint.• Discharge of Water= LAN/60.• Discarge of water for double acting pump.=2LAN/60.
  4. 4. Slip of Pump• The difference between actual and theoretical discharge is known as slip of the pump.• Force on the piston during suction stroke=wHsA• Force on the piston during delivery stroke= wHdA• Power= wQ(Hs+Hd)
  5. 5. Indicator Diagram
  6. 6. Variation of Pressure In section and Delivery pipes due to acceleration of the piston
  7. 7. Effect of Acceleration on the Indicator Diagram
  8. 8. Example 1• A single acting reciprocating pump has a plunger of diameter 300mm and stroke of 200 mm. If the speed of the pump is 30 r.p.m. and its delivers 6.5 litres/sec of water find the coefficient of discharge and the percentage slip of the pump.
  9. 9. Example 2• A single acting reciprocating pump, having plunger diameter 125 mm and stroke length 300 mm is drawing water from a depth of 4 meters from the axis of the cylinder at 24 r.p.m The length and diameter of suction pipe is 9 meters and 75 mm respectively. Find the pressure head on the piston at the begining and end of the suction stroke, if the barometer reads 10.3 m of water.

×