Clinical Case
                  DO by Dr Andreas Hugenberg




                                 US: 1-800-811-3949        ...
DO
By Dr Andreas Hugenberg




1                                                                     2




DO on lower sec...
DO
By Dr Andreas Hugenberg




5                                                                     6




Completion of t...
Upcoming SlideShare
Loading in …5
×

DO cavity on lower second premolar by Dr Andreas Hugenberg

523 views
476 views

Published on

The V3 Ring has the widest indications for use of any sectional matrix ring. The only nickel-titanium ring, the V3 ensures optimal separation forces to produce perfect, tight contacts and an anatomically correct Class II composite restoration.

Published in: Education, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
523
On SlideShare
0
From Embeds
0
Number of Embeds
4
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

DO cavity on lower second premolar by Dr Andreas Hugenberg

  1. 1. Clinical Case DO by Dr Andreas Hugenberg US: 1-800-811-3949 UK: 0800-311-2097 CA: 1-866-316-9007 NZ: 0800-TRIODENT INT: +64-7-549-5612 AU: 1-800-350-421 If you have a great new product idea or wish to contact us for more information on our great products, go to www.triodent.com/product-information-request.
  2. 2. DO By Dr Andreas Hugenberg 1 2 DO on lower second premolar. V3 Matrix and medium Wave-Wedge in position. Note that the tab has been folded over on to the marginal ridge of the first molar. Applying finger pressure to the tab while placing the wedge prevents movement of the matrix. 3 4 V3 Ring in position. Note how the matrix is wrapped around Side view showing how the V-shaped tines leave room for the the tooth. wedge. Also note that the V3 Ring has been pushed firmly down to maximize its stability. US: 1-800-811-3949 UK: 0800-311-2097 CA: 1-866-316-9007 NZ: 0800-TRIODENT INT: +64-7-549-5612 AU: 1-800-350-421 If you have a great new product idea or wish to contact us for more information on our great products, go to www.triodent.com/product-information-request. Case Study 2
  3. 3. DO By Dr Andreas Hugenberg 5 6 Completion of the composite placement. Immediately after matrix removal. Note the lack of flash. 7 8 Finished restoration with rubber dam in place. Completed case. US: 1-800-811-3949 UK: 0800-311-2097 CA: 1-866-316-9007 NZ: 0800-TRIODENT INT: +64-7-549-5612 AU: 1-800-350-421 If you have a great new product idea or wish to contact us for more information on our great products, go to www.triodent.com/product-information-request. Case Study 3

×