DO cavity on lower second pre-molar by Dr Andreas Hugenberg
Upcoming SlideShare
Loading in...5
×
 

Like this? Share it with your network

Share

DO cavity on lower second pre-molar by Dr Andreas Hugenberg

on

  • 1,129 views

The V3 Ring has the widest indications for use of any sectional matrix ring. The only nickel-titanium ring, the V3 ensures optimal separation forces to produce perfect, tight contacts and an ...

The V3 Ring has the widest indications for use of any sectional matrix ring. The only nickel-titanium ring, the V3 ensures optimal separation forces to produce perfect, tight contacts and an anatomically correct Class II composite restoration.

Statistics

Views

Total Views
1,129
Views on SlideShare
1,097
Embed Views
32

Actions

Likes
0
Downloads
2
Comments
0

3 Embeds 32

http://www.triodent.co.uk 29
http://triodent.co.uk 2
http://localhost 1

Accessibility

Upload Details

Uploaded via as Microsoft PowerPoint

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

DO cavity on lower second pre-molar by Dr Andreas Hugenberg Presentation Transcript

  • 1. Clinical Case
    DO Cavity on Lower Second Premolar
    by Dr Andreas Hugenberg
  • 2. 1
    DO on lower second premolar.
  • 3. 2
    V3 Tab-Matrix and medium Wave-Wedge in position. Note that the tab has been folded over on to the marginal ridge of the first molar. Applying finger pressure to the tab while placing the wedge prevents the movement of the matrix.
  • 4. 3
    V3 Ring in position. Note how the matrix is wrapped around the tooth.
  • 5. 4
    Side view showing how the V-shaped tines leave room for the wedge. Also note that the V3 Ring has been pushed firmly down to maximize its stability.
  • 6. 5
    Completion of the composite placement.
  • 7. 6
    Immediately after matrix removal. Note the lack of flash.
  • 8. 7
    Finished restoration with rubber dam in place.
  • 9. 8
    Completed case.