Jam Aqualarm Leak Detection Brochure

882 views

Published on

0 Comments
2 Likes
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
882
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
0
Comments
0
Likes
2
Embeds 0
No embeds

No notes for slide

Jam Aqualarm Leak Detection Brochure

  1. 1. Tel: +44 (0)191 490 1547Fax: +44 (0)191 477 5371Email: northernsales@thorneandderrick.co.ukWebsite: www.heattracing.co.ukwww.thorneanderrick.co.uk
  2. 2. • • • .....• ...;Our journey to date has taken 25 years in the field of design, manufacture andinstallation of water leak detection and environmental monitoring systems.With the wealth of knowledge gained, J.A.M. can guide you through the designprocess, manufacture the products and carry out the installation to the exactingtimescales of the contracting process and program. We +Arill also support the productand Client with after sales service and preventative maintenance contracts for yearsto come.J.A.M. Limited have also been involved with the design, supply, installation &commissioning of electric trace heating systems for a number of years, and havesupplied equipment to a vast array of end users and Clients. Although originallytaken on board as a supplementary product to our range of environmentalmonitoring systems, we rapidly gained the reputation of a professional, reliable andcost-effective supplier of trace heating in its own right.We feel the products within this brochure offer the most cost-effective solutions tocurrent building services requirements and would encourage you to visit ourwebsite: www.jam.uk.corn to see our systems in action.I have taken the step of releasing my personal e-mail address for anyone to contactme with comments or suggestions.Paul GoodacreManaging DirectorPaul.Jam@virgin.net
  3. 3. ContentsLeakigensemcitdargl&PjiTypical Applications 1System Introduction 2Which System is Best for You?Aqualarm i-ZoneSystem Design Guide .3Control Panels Specification and Data............................................................SDetectors 7F Gas Legislation 10Zoned key Components 11LeakSense2iSystem Design Guide 13Specification and Data 15Locating Key Components 17Aqualarm One TouchSystem Design Guide 19Specification and Data 21Key Components 24Networking Systems 25Universal Detectors 28Trace Heating 29Agents and Distributors 32Our Credentials 33
  4. 4. Typical ApplicationsComputer SuitesLT./Sender RoomsDealer FloorsData CentresHotelsKitchen/Toilet & Vending AreasHospitals (rv1Pli Plant Rooms)Leisure ComplexesSupermarketsListed BuildingsMuseumsArt GalleriesArchive FacilitiesSample of aCLialanTl InstallationsBank of England - LondonCitiGroup- Canary WharfBarclays Trust- DubaiHSU( - DubaiCredit Suisse - LondonMicrosoft - LondonMeadingDresdner Kleinwort - London13.T.Centre - LondonDepartment of Education - RuncornDepartment of Transport - LondonHertfordshire Constabulary HQGreater Manchester PoliceGlobal Switch - London, Australia & Hong KongNatural History Museum - LondonScience Museum - LondonVictoria & Albert Museum - LondonRAF Benson • OxfordPostal Heritage - LondonChastleton House • OxfordMarlborough House LondonAsda Stores - .GlasgowWhittington Hospital - LondonLeeds University - LeedsDHL - PraguePolice Headquarters - Hong KongT BANK1
  5. 5. System IntroductionaTILalarinThese produce are our latest Zoned range of systems using art addressable method for irrstaliation. Eachsystem will be easier to install with less interconnecting cable used. The control panels can simultaneouslymonitor our water, oil, refrigerant gas, temperature and humidity detectors The control panels areavailable as an i-Zone 5, capable of monitoring up to 5 detectors, or as an i-Zone 10/25 capable ofmonitoring between 10 and 25 detectors. Multiple i-Zane systems tan be networked together. monitoredby an Aqualarm One-Touch system master control panel.LeakAense2irem,remLC.101.19r1U.71A stand alone system capable of monitoring up to 1500rn of cable and able to display the meteragereading relating to the point of contact that water has made with the detection cable with an accuracy of.1- 1 metre. This system dS0 has the added advantage of displaying a meterage reading of any opencircuits caused by damage with the same accuracy.Now also available as a ZLM-500 zoned locating module. a simplified version to allow a network of theseunits to monitor multiple areas, all connected back to either a master i-Zone panel which will display thealarm conditions and meterage reading of each ZLM•500, or connected to an Aqualarrn One-Touchsystem that can also display graphic maps of the alarm locations.amiare.,1044This is the most comprehensive system we have produced to date We have designed this system to benetvvorked to multiple Aqualarm control panels as well as being able to function as a stand alone controlpanel. All system functions are displayed on a 12 inch colour touch screen monitor. Powered by a PCbased operating system, using Windowste, protocol, all operating manuals, service information and asinstalled system maps can be stored for future reference.This system can monitor all Aqu alarm control panels and the full range of Aqual arm dctcctors, todeliver the complete package.2
  6. 6. Connection toarr/SwiaVolt•Ire.ecorMaS.R5-46MoteCLI1 Flow CI linRecommendedoneeveryaS metres orwhere requiredWL/1 %Naming Labels.Recommended oneevery 5 metres.CD-i€1,2, S and 1CmZEOLInterconnectingwiringto I-ZoneControl PanelCDRE-24 STDI-24Interconnecting -wiringto i ZoneCOMM.! PanelnneSystem Design Guide: Perimeter and Footprint Protectionbeneath access flooring, using zoned systemDrip Trays3
  7. 7. Cormerticl toBUS via Volt-freecontacts.I15 185Conduit containinginKreonnOttinG wir6StorageTankIriteroonn,actingwiringto control panel11,11:4-24Interconnecting wiringi-Zungcontrol panelOtani an! 4I IiQlerelTrayPrpeWCel<Interconnecting wiringto i-baneconliol panelFLI-24Boiler/Plant Room Applicationusing Detecting Cable and Point Detectioni•ZoneCararolPanelNomCD-K detecting cable 1711.11Stlse lostalled on theoutside of lagged pipeworkCD-1s held In place byI) ktt cableties.Fuel Oils/Non-Conductive LiquidsVa IvoFloat DetectorUsed in sump/tankapplicationsOverflow DetectorUsed in overflowpipeworkinterccnrecrng wiringltp E-Zone control panel4
  8. 8. ENVFROIRM€NrAL IliONITORN4 SY STEhl•Control Panel Mode i-Zone 5The i-Zone Control Panel shall be wall mounted and be of a mild steel construction and powder coated. Itwill be capable of monitoring the full range of Aqua!arm detectors for water, fuel oils, chemicals,temperature, humidity and refrigerant gases. The control panel is an addressable system capable ofmonitoring 5 detectors/ addresse5 SiMki taneouslyThe default detector identification is 70110 -Zone2` etc, however these can be programmed to displaycustomers requirements, up to 24 characters per zone i.e. Zone 1 - Room 5 2nd Floor. This has to becarried out at time of manufacturing.The control panel can store a 100-alarm event history log into non-volatile memory_ During normaloperation, the Green LCD screen will display the current time date together with SYSTEM CLEAR status.The i-Zone 5 Control Panel can also be linked to a maximum of 5 ZLNI-500 modules, resulting in a singlesystem, monitoring 2500 metres of detecting cable, and in the condition of an alarm, will display arneterage reading accurate to 14- 1 metre to the point of water contact with cable.The control panel will be provided with a TEST button, MUTE button and the facility to view the100-event history log. In an aiarm state, the LCD will display the activated detector identification and a97db (at 1 metre} audible alarm will sound.For remote signalling, the control panel will be supplied as standard with the following outputs:RS42,5, Common Alarm, Network Failure, Mains Fail, Rattery Fail A Service Required.For safety, the control panel is fitted with a key operated door lock and power off door switch.Main Features114mm x 64mm Back-lit Green LCD Screendisplayl ng:Current Tirr)e Si Data, System status, Alarm status &available Button functions. Power On.Power Support System ,On. Service.System will monitor 5 detectors/addresses or21.M1.0-500s, simultaneously,Last 100 Event Memory_Alarm Siren 97db IQ 1m.Alarm horn Mute, Test & another functionsdisplayed or LCD when required,Lockable mild steel cabinet.Powder Coated RAL7035.Door interlock safety switch.Mains Fail Battery Back Up. ill Hours)OutputsP.S4B5Volt -free outputsCommon Alarm.Network Fall.Mains Fail.flattery FaService.Mains Voltage Ra rigs120 or 240 volts A.C, 02 50 or 60 Hz.Normal Operating Voltage24 volts D.C. internally suppliedOperating Temperature Range0 to 50 deg.C,ApprovalsB5 EN ISO 14001 and ISO 9001: 1994.EMC Directive 89i3361EEC, CE Marked.Cabinet DimensionsHeight 330mmWidth 255 mmDepth BSmm5
  9. 9. Control Panel Model i-Zone 10125The i-Zone Control Panel shall be wall mounted and be of a mild steel construction and powder coated Itwill be capable of monitoring the full range of Aqua I arm detectors for water, fuel oils, chemicals,temperature, humidity and refrigerant gases. The control panel is an addressable system capable ofmonitoring 10-25 detectors addresses simultaneously.The default detector identification is Zoner, Zone2 etc, however these can be programmed to displaycustomers requirements, up to 24 characters per zone i.e. Zone I - Room 5 2nd Floor, This has to Oecarried out at time of manufacturing,The control panel can store a 100-alarm event history log into rion-volatile memory_ DWring normaloperation, the Blue LCD screen will display the current time & date together with SYSTEM CLEAR status.The i-Zone 10-25 Control Panel can also be linked to a maximum of 10-25 ZLM-500 modules, resulting in asingle system. monitoring between 5000 and 12500 metres of detecting cable, and in the condition of analarm, will display a mete rage reading accurate to 41- 1 metre to the point of water contact with cable.The control panel will be provided with a TEST button, MUTE button and the facility to view the100-event history log. In an alarm state, the LCD will display the activated detector identification and a97db at 1 metret audible alarm will sound.For remote signalling. the control panel will be supplied as standar d with the following outputs:8S485., Common Alarm, Network Failure, Mains Fail, Battery Fail & Service Required.For safety, the control panel is fitted with a key operated door lack and power oft door switch,Main Features114mm x 54rrim Back-lit Blue LCD Screendisplaying:Current Time & Cate, System status, Alarm status &available Button functions_ Power On,Power Support System On. Service.System will monitor 10-25 detectors or addresses orZLM-590s., simultaneously.Last 100 Event Memory.Alarm Siren 97db 6:Jt 1m.Alarm ham Mute, Test & all other functionsdisplayed on LCD when required,Lockable mild steel cabinet.Powder Coated FiAL7435.Door interlock safely switch.Mains Fail Battery Back Up. (4 Hours)OutputsRS485Volt free outputsCommon AlarmNetwork rail.Mains Fail.Battery Fail.Servi.ceMains Voltage Range120 or 240 volts A,C 5.1=I or 60 H2.Normal Operating Voltage24 volts D.C. internally supplied.Operating Temperature RangeG. to 50 deg C.Ap provals.as DI ISO 14091 and ISO 9001: 1994.EMC Directive 3g/336/EEC, CE Marked.Cabinet DimensionsHeight 330rrumWidth 255mrnDepth 35mrit6
  10. 10. Detector Model STDi-24The STDi-24 Point of Use Water Detector shallcomprise of TWO components, the detectormodule and the point detector,connected together via a lmjumper cable. Roth the Detector• Module and the Point Detectorshall be manufactured fromSTAREX General ABS (SD-0150)plastic. The Detector Module shall house theelectronic circuitry and the Point Detector shallhouse the gold plated detection pins.The jumper cable shall be connected to the top ofthe Point Detector via a 3-pin plug and socket_A stabilising bar shall be supplied as a means offixing the Point Detector to the floor surface.Conductive fluid touching the two detection pinssimultaneously will cause the detector to enter analarm condition. Alarm status and monitoring isvia a network, using a CAN bus system.Normal Operating Voltage24 volts d.c,Quiescent Current<10mA, per detector.Alarm Current0DrnA per detectorDetector oscillator frequencyLrkFixVoltage at detection cable outlet2 volts e.c.Recommended interconnecting cablecore 0_51nre)screened Twisted Pair tt 120 ohms,Line-out voltage drop1.5mVimApprovalsB5 EN l$C 9001:1994, EMC Directive 89/336dEECCE Marked.Detector Model CDBi-24The Aqualarm CORi-24 Zone Detector Moduleshall comprise a purpose -moulded ABS box,housing the electronic circuitry. At one end ofthe Module a locking fine socket is fitted toenable connection of the detecting cable. Theother end is fitted with a gland for connection tothe PCB. A red Alarm LED shall he incorporatedin the top of the module.The red LED will glow to indicate an alarmcondition. Alarm status and monitoring is via anetwork, using a CAN bus system.Normal Operating Voltage74 voltsQuiescent Current<10mA. per detector.Alarm Current<100mA, per deteceer.Detector oscillator frequency6k -lrVoltage at detection cable outlet2 volts a.c.Recommended interconnecting cableA cure D.StrenA screened Twisted Pair Q5l 170 ohms,Line-out voltage drop1.SmWrnApprovalsBS EN ISO 9001:1994, EMC Directive 69/336/EECCE Marked.Detecting Cable Model CD-XThe Aeualarm" water leak Detecting Cable shallcomprise two flat tinned copper braids separatedand protected by hlelegaine self extinguishingnylon 65 sleeves. This type of configuration givesprotection to the sensing cores against duet andother types of conductive contamination andmechanical damage. The cable is available inmodular lengths of 1, 2, 5 and 10m. Each cable ispre-terminated with a male and female lockingline plug and socket. The Detecting Cable can beused on the i-Zone system (for use with CDEli-24)and LeakSense Systems.Installation MethodWhere protection Is required born a liquid leakingfrom pipework, the Detecting Cable should besecured to the underside of the pipework by cable tiesafter all vapour seal or thermal protection has beencarried out or secured to the floor slab immediatelybelow the pipework with suitable dips or ties.Where protection is required from a liquid leakingfrom eceepment, i.e. water cooled computers, chillerplant, air conditioning units etc., the Detecting Cableshould be secured to the floor stab around theequipment.Voltage at CableNot greater than 2 volts d.c.Overall cliarnetre of cableBmm,Maximum Detecting Cable lengthZoned System! 50rn not including interconnectingcable).LeakSense System: 150Drn iincluding leader/jumpercable).ZLM-500, 500m (including leaderjumper cable),Operating temperature range+1 deg C +85 dog C.ConstructionSelf extinguishing Polyrnide 6.6 rnonohlaments to ISO3n5 with sensing cores of flat tinned copper braid.ColourGrey/blueApprovalsBS EN ISO 9001:1594. EMC Directive 89/33DEECCE Marked.7
  11. 11. Detector Model FLi-24The FLi-24 Liquid Level Detector shall comprise ofTWO components. the detector module and thefloat switch, connected together via a lm jumpercable. Roth the Detector Module and the floatswitch shall be manufactured in high STAREXGeneral A05 (SD-0150) plastic. The glass fillednylon float switch will be held in place by asprung clip, secured to the wall at the leveldesired for the alarm to be activatedThe red LED on the detector module %fulll glow toindicate the alarm has activated. Alarm statusand monitoring is via a network, using a CAN bussystem.Normal Operating Voltage24 volts d.c.Quiescent Current<10mA. per detector.Alarm Currenti00rnA. per detector.Detector oscillator frequency6kHaVoltage to float switch.2 volts a eFloat switch typemake on rise or fall.Recommended interconnecting cable4 core Li_Smir2 screened Twisted Pair ti2/ k2ClohmsLine-out voltage drop1,5mV/mApprovalsBS El ISO 9001:1994, EMC Directive 69836/EECCE Marked.Detector Model IRDI-24The IRDi-24 Point of Use Oil Detector shallcomprise of TWO components, the detectormodule and the Point of Use Detector, connectedtogether via a 1 rn jumper cable. Roththe Detector Module and the Point ofUse Detector shall be manufacturedfrom STAREX General ABS (SD-01S0)plastic, The Detector Module shallhouse the electronic circuitry and the Point ofUse Detector shall house the Infra-Bedtransrnitterireceiver, which shall extend from thebottom of the detector lts height above thereflective sensing area shall be set between3-5rrm. A reflective area (50mrn dia.) must bepainted on the -Floor with paint capable ofreflecting light. (e.g. standard white gloss paint)The top of the Point of Use Detector shall befitted with a sensitivity pot for calibrating theIntro-Red focal point, The jumper cable shall beconnected to the top of the Point of Use Detectorvia a 3-pin plug and socket, A stabilising bar shallbe supplied as a means of fixing the Point of UseDetector to the floor surface A red LED will glowto indicate the detection of a substance.Alarm status and monitoring is via a network,using a CAN bus system.Normal Operating Voltage24 volts d.C,Quiescent Current<10rrIA. per derecriar.Alarm Current<100mA. per detector.Detector oscillator frequency6kH7Infra-Red probe typeGallium arsenideRecommended interconnecting cable4 core acSrnrw screened Twisted Pair r 120 ohms,Line-out voltage drop1,5mWrinApprovalsES EN ISO 9001:199.1r EMC Directive 8.9/3364ECCE Marked_Detector Model OFDi-24The Aqualarm OFD1-24 Overflow Detector shallcomprise a STAREX General ABS box (SD-0150)housing the electronic circuitry. The bottom ofthe ABS box is fitted with a 3/4" BSP threadedconnector with two stain I ess ste el sensing probesextending from the end. The connector shouldbe inserted into a tee to enable the probes tosense any water passing through the main over-flow pipe. A red LED shall also be incorporatedand will glow to indicate the detection of water.Alarm monitoring and status is via a network,using a CAN bus system.Normal Operating Voltage24 valks dQuiescent Current<I0mA. per detector.Alarm Current<100mA. per detector.Detector oscillator frequency61.cRtVoltage at probes2 volts a.c.Recommended interconnecting cable4 corer:0.5mm screened Twisted Pair 43 120 ohms,Line-out voltage drop1.5rriVNApprovalsES EN ISO 9001;1994, EMC Directive 891325/EECCE Marked.8
  12. 12. Detector Model IlDi-24The Aqualarmr 1-1De24 Humidity Detector shallComprise a STAREX General ABS bok -31D-0150)housing the electronic circuitry to detect changesin the level of Tumidity and give an alarm signalshould the humidity drop below the low level setpoint, or exceed any of the two high /eve! setpoints.Levels can be set between 30% and 100% and areentered via the Control Panel. A red LED shallalso be incorporated and will glow to i ndliC ate thedetection of a change in humidity outside of theSet levels. Alarm monitoring and status i5 vie anetwork, using a CAN bus system,Normal Operating Voltage24 voltsQuiescent Current<100mA per detectorAlarm Current-4100MA. per detector.Humidity range30 • 100%.Recommended interconnecting cablecore 0.5men2 screened Tv,d5led Pair CP 120 ohms..Line-out voltage drop1.571V/mApprovalsBS EN ISO 9001:1904, EMC Directive 39/33EdEECCE Marked.Detector Model TDi-24The Agualarrre TIDi-24 Temperature Detectorshall comprise a STAREX General ABS box (SD.0150) housing the electronic -circuitry to detectchanges in temperature and give an alarm signalshould the temperature drop below the lowtemperature set point, or exceed any of the twohigh temperature set points_The "set points are entered via the Control Panel.A red LED shall also be incorporated and willglow to indicate the detection of a temperatureoutside of the set points. Alarm monitoring andstatus is via a network, using a CAN bus system.Normal Operating Voltage24 volts d.c.1111111)Quiescent Currentio2OrriA. per detector,Test/Alarm Current<15OrnA. per detector.Temperature range10 • 100 deg. C.Recommended interconnecting cable4 core 0.5mm1screened Twisted Pair itt 120 ohms.Line-out voltage dropI .5.rnVfmApprovalsB5 EN ISO g001:1934. EMC Directive 8E/336/EECCE Marked.Detector Model RGi-xx-24The Agualarrn RGiocx-24 shall comprise a STAREXGeneral ABS box (51)-C150) housing the electroniccircuitry to detect the presence of the nominatedrefrigerant gas. The alarm threshold can beadjusted via the control panel. A red LED shallalso be incorporated and will glow to indicate thedetection of refrigerant gas above the set level.The Detector can detect the following refrigerantgases. (There are a sample of most commonlyused, but others are available) R-17, Ft-22, R125, R-134a, R-401 a, 11-401b, R-401c, R-402a, R-4026, R.403a, R-403b, R-407a, R-407b, R-407c, R 502,Ft-507, R-410a.Alarm status and monitoring is via a network,using a CAN bus system.Normal Operating Voltage24 volts d.c.Quiescent Current<180mA. per detector.TestJAlarm Current<350mA_ per detector.Operating temperature range10 - 100 deg.0Refrigerant gases se nsedSee hitRecommended interconnecting cable4 core 0.5rnm? screened Twisted Pair @ 120 ohms.Line-out voltage dropI.SmVirnApprovalsBS EN ISO 9001:1994, EMC Directive 89/336/EECCE Marked.9
  13. 13. F-Gas Regulation No. 842/2006Prevention and Detection of LeaksThe EuropeanIUniona5 F--.a5 Regulation No. 842/2006 became law on 4th July 2006, and many of therequirements came into force on 4th July 2C07.F-Cases include all HFC refrigerants such as R134A. and mixtures containing F-Gases such as R407C. R410.0,and 11404A.if you own equipment containing HFC refrigerants in stationary equipment, you now have new legakobligations under the F-.2 as Regulations.Below are sections of the requirement that relate to leak prevention and detection.F-iGas Requirement Date ofEffectRow to implementthe requirementFurther InformationOperators of equipment mustprevent leakage, ensure leakche:ks are carried out andcarryout any necessary repairs45 soon as possible. Properrefrigerant recovery must alSOhe in place_04.01.2007 1)Works to be carried out byqualified personnel {currentrequirement Is City & Guildslonor CITD only).2)Follow a standard leakcheck procedure Set by theCommissionwww.defra.gov.ukicorporate/consult/f-gasiindex.htmOpefa tors must ensure systemsare checked for leaks:1)At least annually If morethan 3kg charge-2) At I test once every 6months if over 30kg. If anautomatic leak detectionsystem is installed. they onlyneed to check every 12months,3)Automatic leak detectionsystems MUST be installedon applications with 3.00kgor more, and these systemsshould be checked every 6months.If a leak is detected andrepaired, further check mustbe carried out on the repairwithin 1 month to ensure therepair has been effective.04.07.2007 11 Personnel Qualified to thelevels set out by theCommission can only carry outthe checks.2) install a n automatic leakdetection system that meetsthe requirement set by theCommission {see definitionbelow)www.dti.gov.ukiin novationisustainabilitylfgasesepage28$139/htmlDefinition of Leak Detection SystemLeak Detection System • This meansa calibrated mechanical, electrical or electronic device for detecting leakage offlourinated greenhouse gases, which, on detection, alerts the operator.You con download the lull Regulation atwww.dti.gov.0 kfinnovationfsustain a bi lity/fgasestp age28889intml10
  14. 14. i-Zone• Monitor up to 5 detectors• battery back-up internal• Volt-free contact• Mild Mei construction IP54• Powder coated RAL 7035Code- 60194I-Zone 1025• Monitor between 5-23 detectors• Battery back-up internal• Volt-free contact• Mild steer construction IP54• Powder coated RAL 7035Code:10 Zane. 602015 Zone: 602120 Zone: 602225 Zone: 60234s.5TDi-24 OFDi-24Point of use Detector. Overflow Detector.Coder 6026 Code: 6030CDIN-24Zone Module.Code: 6027IRDi-24Point of use Infra RedDetector.Code. 6029RGI-xx-24Refrigerant LeakDetector.Code: 6031 .0*I ItTDi-242 Stage TemperatureDetector.Code:6032Remote Alarm PanelsOptional ExtrasIZ/FIV1-1Semi-flush Mount Frame for Control Panels. MildSteel finished in RAL 7035 Grey powder coat.Code: 6025(I:Zone i-Zone Key Cum ponentsDetectors CD-x Water Detecting CablesDetecting Cable complete with maleffe maleconnections.CD-1 7 metre Code: 6004CD-2 2 metre Code. 6005CD-5 5 metre Code: 6006CD-1U 10 metre Code: 600174r1716":12-EOLEnd of Line Resistor Plug. Code:6036CL.! CL/1-100Floor Clips.Bag of 10. Code: 5015gag of 100, Code: 6016rhOthever dips are serf-adheAre barked the use pea suitafeadf&shreigiLre is rerwrorrrerded.OkirVILF1-10 f WL/1 100Warning Labels.Bag of 10.Rag of 100FLI-24Float Detector.Code: 6023HDi-24Humidity Detector.Code: 6033Code: 5719Code; 5720All are 12v powered by Main Control Panel andare complete with 97db alarm. Specified RemoteAlarm Panels can also be made to order to 61.1itspecific building Interiors_PC-I • SB-1RP-1 Single Channel Code: 6045 Protection Cover for Stabilising Par forRP-2 Two Channel Cede: 6046 Point of Use Detectors. Point of Use Detectors.RP-3 Three Charrne I Code: 6047 Code: 6035 Code: 603411
  15. 15. Connection toEMS viaVolt-koacontacts,R5,485.RS-232Nateail Flom Clips.Recommended oneEvery OS metres orwhere requited.van WArnirg Lobos.Recommended rareevery 5 metres.Telecom 1,quipmentRacksConnection toRMS. via Volt -Freefantods,RS-485RS-232(4Telecom EquipmentRacksC1734Z 5 arid 1 OirnL5-ECILSystem Design Guide: Perimeter and Footprint Protectionbeneath access flooring, using location systemSerpentine Layoutbeneath access flooring, using location system13
  16. 16. Canne€tion toEMS.via Unit-freecontacts,1,[5-4S5RS-212 co Fi9orciio5.Ittcoromencled antevery 0.5 metre orwliererequired.Mil Warning LabelsRecornmerKied onetyely S memos.Note6.5rUCSO IOW lave"5.108)ern ferrConneetlan to5M5 via Volt-free.ranraeti,1,15.-4S585.232NoteLifr Jumper CablesreywatglInNarm and flisnr114Drip Trays!-Itien,421 High Level to Low LevelMulti Area/FloorOption 1 See page 25 for Networking Options
  17. 17. EINVIRONIJEHTM. MONITORING Sysrelyvt_ 11:24 V 23106/152Control Panel Mode LS-2iThe LeakSense Control Panel shall be wall mounted and be of a mild steel construction and powdercoated with a 6 line format 114rrim x fp-Imm Blue LCD screen.When connected to a single phase mains supply the Control panel shall generate Pulsed Echo Radarsignals, which shall be transmitted along the entire length of the Leader/Jumper and Detecting Cables.Any change in the characteristics of the table is compared to pro-programmed limits and dependent onthe type of change the LCD will display an Alarm and the Alarm Horn will sound.The LCD screen will, during normal operation display the current Time and date, and the words SYSTEMCLEAR h will also display the functions available of the soft touch buttons located each side of the LCDtogether with a pulsing Heart denoting that the system is connected to a healthy Mains Power Supply.In an Alarm state the LCD will display current Time & Date, a meterage reading giving the location of theAlarm and the Alarm state. i,e. Water Detected ar Open Circuit. The Alarm Horn will also sound. It willalso display the functions available of the soft touch Buttons and at the touch of a button, produce anAlarm Verification Graph (This will show the wave form of the actual alarm).Clean Signal contacts for Water Detected, "Open Circultr, Mains Fail, Battery Fail, and Service,together with RS-232 and RS-4 outputs are fitted as standard for remote signalling.For safety the Control Panel is fitted with a key operated lock and Power Oft door switch.On completion of the installation, a system location map will be prepared and encapsulated to enableeasy identification of the Alarm location.Main features114rtorn x 64min LCD Screen displaying:-Current Time & Date, System status, Alarm status &available Dutton functions,over On.Power Support System ,On.Service.System will monitor 15X metres of cable,Last 100 Event Memory_Alarm Siren 97db It lm.Alarm hom Mute. Test and all otherfunctions displayed on LCD when required.Lockable mild steel cabinet.Powder Coated PAL7035.Door interlock safety 9.viten.Mains Fail Battery Back Up. (4 hours)OutputsRS-232Volt free outputsWater Detected. Open Circuit. Mains Fail. Battery Failand Service.Resolution+ or - I metre.Mains Voltage Range120 or 240 volts A.C. 12 50 or 6D Hz_Normal Operating Voltage24 volts D.C. internally suppliedOperating Temperature Rangeto 50 deg EApprovalsBS EN ISO 140131 and ISO 9001: 1994.EMC Directive S9/335,EEC. CE MarkedCabinet DimensionsHeight 330mmWidth 255MITIDepth 8Sn-1m15
  18. 18. Zoned Locating Module Model ZLM-500LeefftenjaiThe Aquala rm Zoned Locating Module shall be wall mounted and be of a mild steel construction.painted and powder coated.The Zone Locating Module shall generate Pulsed Echo Radar signals, which shall be transmitted along theentire length of the Leader/Jumper and Detecting Cables. Any change in the characteristics of the cable,whether water detected or open circuit, occurs, these are compared to pre-programmed limits and whenthe limits are exceeded, an alarm signal providing the meterage reading accurate to +I- 1 metre, will besent to the designated Aqualarm• master control panelThe LM-500 is capable ofmonitoring up to 500m 0-F combined Leader/Jumper end Deteeti or cables.Power to the alvl-500 is generated via the Aqualarrn CAN network.A local, volt free alarm contact is available within the Zuvi-500. Other alarm contacts will be availablefrom the designated "Aqualarrn master control panel.The FLM-500 can only be used within a network designed system connected to either an i-Zonecontrol panel or One-Touch system to monitor and display the relevant alarms and information.Main features Operating TemperatureCAN BUS Technology. 0- 5C1 de9 CSystem will monitor 504m of combined cable.Door Power Off Interlock Switch. ApprovalsPower On LED. BS EN ISO 9001: 1994Key Operated Cabinet Lock, EMC Directive 89/336/EECAlarm Relay Output. EC Marked.Network Fail Relay Output.Powder Coated PAL7035, Cabinet DimensionsHeigh( 150mrrOutputs Width 200rnru$-232 Depth 135rnmRS-48SResolutionti• 1 metre.Power Supply24 volts via Aqualarrn CAN network.Normal Operating Voltage24 volt D C. internally supplied.Cabinet RatingIP 54.16
  19. 19. Floor CI ipsCL/1-10 Bag of 10. Code: 6015CL/1-100 Bag of 100. Code: 6016Ih4lsoy9h dice Aft ArloCkhesNle Wald the we of a .witaiYeadhesivelpikre Is recommendedWarning LabelsWM -10 Bag of 10 Code- 5719WL11-100 Bag of 100 Code: 5 720Optional ExtrasL5frii1B-1Replacement MappingCock: 60181VFM-1Semi-flush Mount Frame for 1_52i only. woe Steelfinished in RAL 7035 Grey powder coal.Code: 6025Key ComponentsLeaktenSe5%-zwurlec.agampimenControl Panel Model 15-21.• 230v AC• Mild Steel enclosure IP54• Powder coated RAL 7035• Surface or semi-flush mount (Frame Optional)• To Monitor 1500m of cable• RS 232 and RS 485 volt-free outputs• Battery beck-up fitted interna/lyCode: 50002LM-500▪Mild Stec! enclosure- IP54• Powder coated RAL 7035i• To Monitor SOem of cablePowered via networkCode 501/Key ComponentsLeader CableL5/LC3.5 3.5 metreLS/LC7 7 metreCode: 6002Code: 6003L5-EOLEnd of Lire Resistor Plug. Code 6017CD-x Water Detecting CablesDetecting Cable complete with male/femaleconnections.CD-1 1 metre Code: 6004CP-2 2 metre Code: 6005CD-5 5 metre Code: 6006CD-10 10 metre Code: 6007LS-JC Jumper CablesJumper Cable complete with ma1tifemaleconnections. Longer lengths of Jumper Cablecan be ordered.LSIJC5 5 metre Code: 6009L5f1C10 10 metre Code: 6010LSLICZO 20 metre Code: 6011Remote Alarm PanelsAll are 12v powered by Main Control Panel andare complete with 91dB alarm. Specified RemoteAlarm Panels can aim Ise made to order to suitspecific building interiors.RP-1 Single Channel Code: 6045RP-2 Two Channel Code: 6046RP-3 Three Channel Code: 604717
  20. 20. J.A.M. Limited has taken the field of environmentalmonitoring to a new level with theacelaplo,..d.system.Combining the latest addressable CAN 2UStechnology for monitoring and displayinginformation of alarms/alarm conditions within therunning protocol of a MS Windows0 program.Specification Summary• 12 inch touch screen LCD full colour VGA monitor• Capable of monitoring up to GS0 zonesiaddresses,including water, refrigerant gas, fuel oils, hightemperature and humidity• Detailed layout maps electronically stored andeasily retrieved to show alarm condition andlocation• Alarm history logged for future reference• Mend alone system or easily integrated with El.MSsystemsTypical Applications• Computer suites• IT environments• Dealer floors• Electronic offices• Hotels• Hospitals• Leisure Complexes* Supermarkets• Listed Buildings• Museums• Art Galleries• Archive FacilitiesRG1Ref! igerant SensorZLM.St1.0Zoned Locating ModuleAPM•25Area Power ModuleTDI•24Temperature SensorIR D1.24Oil Leak DetectePoint Sensor19MCILiderone, Envftonmental Monitoring System
  21. 21. MICILIMIErM ,1044.011""Va.CON1MUNICATIONSil_T_ SUITE1111116:RECEPTION/SECURITYCP41.1000Central Processing UnitSTD1.24/41)1.24(DarDetecting Cable Humidity Sensor Point oP usc. Lietc-ctoiTifuldTouch Screen MonitorDesk bp or W.211 Monitor20
  22. 22. aw9karm Central Processing Unit Model CPU 1000The Aqualarm One Touch Central Processing Unit shall be wall or floor mounted and be of a mild steelconstruction, painted and powder coated.The CPU-1000 combines the latest addressable CAN BUS technology for monitoring and displayinginformation of alarms I alarm conditions within the running protocol of a Windows 0 program. It will becapable of monitoring up to 25 detectors from the full Agu alarm range including water, refrigerant gas,fuel oils, temperature and humidity as well as up to 25 i-Zone Control Panels or APM-25 Area PowerModules resulting in a combined monitoring power of up to 65C detectors.The CPU-1000 can also monitor up lo 23 LS-2i LeakSense Control Panels or ZLM-300 Zone LocatingModules, to create a fully comprehensive Locating System.When alarm conditions are raised, they will be displayed On the TSM-1 Touch Screen Monitor, with the useof detailed layout maps for the area(s) being protected. Alarm history is stared an the units own internalhard disk drive for future perusal.Operating Instructions, Commissioning, Maintenance and Service logs are all stored electronically on thesystem for ease of retrieval and use.The system is supplied with 5 volt free outputs, and a R5-485 output to relay alarm conditions to othercontrols such as Building Management Systems.As the CPLI-1000 is essentially a PC based product we strongly recommend the power supply is eitherconnected directly to the building UPS system or an after market proprietry unit which is purchased tosupport the system should the mains be interrupted or tail.Main FeaturesCAN BUS TechnologyAlarm Horn 57db 0 lirAlarm Horn Mute FacilityDoor Power DI Interlock SwitchCircuit Continuity AlarmMains On LEDBattery On LEDReset FacilityKey Operated Cabinet LockAlarm Relay OutputMains Fail Relay OutputNetwork Failure OutputService OLle Output1S485 OutputPower Support SystemParallel Printer connectionPower Supply120-240 volts, single phase 50Hz fused 5 Amp_Normal Operating Voltage24v do internally Supplied.Cabinet RatingIP 54Voltage to Detector24 volts dc.Quiescent Current1.2 Amp 24e de.Operating TemperatureU SE; deg CApprovalsBS EN iSO 9001:1994EMC Directive 89/336.1 ECCE Marked,22
  23. 23. a9ualarm Area Processing Module Model APM-25gniNs Gm40The Aqualairon One Touch Area Processing F Power Module shall be wall mounted and be of a mild steelconstruction, painted and powder coated.The APV-25 combines the latest addressable CAN SUS technology for monitoring information ofalarms/alarm conditions within the running protocol of a Windows lb program. It will be capable ofmonitoring the full range of Aqualarrn detectors including water, refrigerant gas, fuel oils, temperatureand humidity as well as other devices capable of producing a volt free alarm outputThe APM-25 is capable of monitoring 25 zones f addresses. This unit must be used in conjunction with theCPU-1050 Central Processing Unit.When alarm conditions are raised, they will be relayed to the CPU-IC00, which in turn will display them onthe TSM-1 Touch Screen Monitor, with the use of detailed layout maps for the area (s) being protected.For remote signalling, the control panel will be supplied as standard with the following outputs:RS485, Common Alarm, Network Failure, Mains Fail ti Service Required.Main FeaturesCAN BUS TechnologyDoor Power Of Interlock. SwitchMains On LEDKey Operated Cabinet LockAlarm Relay OutputMains Fail Relay OutputNetwork Failure Relay OutputFoyer Support SystemRower Supply120-240 volts, single phase SOFIr fused 5 Artip.Normal Operating Voltage24v dc Internally Supplied.Cabinet RatingIP 54Voltage to Detector24 volts dcQuiescent Current1.2 Amp@ 24v dc.Operating Temperature41 50 deg C.ApprovalsBS EN ISO 9001:1954[MC Directive 69/33StEECCE Merited_23
  24. 24. 41".4s1114T5M-1Touch Screen MonitorDesk Top or Wall MountedCode: 6038-----____ —CPU-11100Central Processing Unitpjer 6038Ada&ASV-25Arcs Power ModuleCode: 6039CDB1.24Zone Module,Code: 60.21131:11-24Point of use Infra RedDetector.Cc kle: 6029a9ualarn Aqua!arm One Touch Key Components00,Detectors CD-x Water Detecting CablesSTD1-24 OFIN-24Point of use Detector. Overflow Detector.Code: 6026 Code: 6030Detecting Cable complete with maleffemaleconnections.CD-I 1 metre Code: 6004CD-Z 2 metre Code. 6005CD-5 5 metre Code: 6006CD-10 10 metre Code: 6007R Gi-xx-24Refrigerant LeakDetector.Code: 60311Di-242 Stags TemperatureDetector.Code. 6032farIZ-EOLEnd of Line Resistor Plug. Code: 6036CL11-10 1 CU1-100Floor Clips.Bag of 10. Code: 6015Bag of 100. Code: 6016AI hough dips are zed-adhesive backed die Else of a giIabreadhesivefghle h recomirpeodesi.4-INI11-10 i VVIA-100FLi-24 14D1-24 Warning Labels.Float Detector, Humidity Detector, Rag of 10. Code: 5719Code. 602e Code: 6033 Bag of 100. Code: 5720Optional ExtrasPC-T 513-1Protection Cover far Stabilising Bar forPoint of Use Detectors. Pfldrrt of Use Detectors.Code: 6035 Code: 603424
  25. 25. Networking Options LeakSense Locating SystemsStageA Oral L7 SOW -64and detecting cable can he rrionhamdby each am-sin Module_ 2nd FloorCiNNet workllnk 710i1,51111bstua CCONCillModulei-7rno 7S rrsnftr5113andaht-srm Vp to 25 LL1/21.5a, ModulesZona tocadon can de netstiurNal on a singlemodulaZLM-50C1 connected toi-Zone Control Panel, showing-floor and rneterage readingi-Zone display C1)-K DiteCtlIN CWt.3rd FloornianoTp !,our rterand anew.112!,Fi _lo ENS viaVolt Free Cordacti and PS 48525 Control Paredit:ss ntrAlaZLIA-SDO2nd Floor MelLiquid detectedStage 21_5-2i Control Panels connected toi-Zone Control Panel, showingtheterage reading an local paneland floor & meter age readingon 1-Zone display.A total of 1509re or Ilimpsensingand detecting cable carlbeincritccaauhyaach LS2I C.iirrai Parr!dqRemote Sounderand Rmcran1st FlpprJolt:, 25 Leo1.6ense Syrwtern3can be net worked an a singleOne Touch PanelwaterDote:clodat :250M,77.11111...To ULMS viaVolt Free Contacts and RS 48511:56 MS108Lee k•Son5n LS-2i2nd Floor 250mLiquid DetdOtedEl
  26. 26. ZLM-500 connected toOne-Touch System, Showingfloor and rneterage readingtogether with graphic map ofeffected area.IJ X Drnly Wag tableUp L. mXim Ur LOrnbinardnonrsensi rig and detectioncad e per ZLY-SONSI odule2nd NamSrd FlFilename/ Link eihusnotune LocationMackierefWater Leak Detected_ 2n1 Firm250iel Male East nel&ETSIka.Tooth SL. ern Montt.runner will:. 0.12-1001Faatessing Unit..e,--- ToUMSviaVoFtFreeConiacts and F5 A857] ]d-301:Zane We tin.MOLL E.LiplitiS Ti-SrtrUeleddarr-scan he redworked on a singleOne loud, Control PanelStage 4LS-2i Control Panels connected toDne-Touclr System, showing rneteragereading OR local panel and floor,meterage reading and graphicmap or One.Teurh System,314 FicxyA total of 150E1m pt Non-sensingand itable canhernorsliurrdolorsliurby ealth LS2iCtrotpul Powl2nd plow iiWaterCele:21Aa9 7S OmCary2Terte.rni k LinkUp co 25 LeartSense SyswinsCarl tee net...eked Ors aSITigieOni-louttiCkarkrai Panelip X Deirc Port; rt,ahlir_EALS-2.ConticiPanel111( •%momInd Ent c•-sConedAnvilLS-2J Control Panel1111116_ •Skidisir Look Maki; 2nd Floe(255m WI* FeatToilel11%1.1Traireh Sonora, Jel maresonneiteri In COLI-10012F rooming UnitiskFlearStag e 3ilkTo ELMS viaVali Free Eaintacts and PS .tISS
  27. 27. Networking Options Zoned Systemsremontalont11.71-14Oates totLI kr-scro module- an-el cipici 500m elCr-x Deina_tion CableTo EngSviaVolt Peetorgacts arm:KG-16SStage 1APIv1-25 Modules connected to aOne-Touch System, showingfloor, meterage reading andgraphic map.A marl-num al 75 detector; At any unii.34tombinalion can bec caninected. Flunldllyi peed And 75DetectoritCDF11.24 01:1-4Water "Detection CableOuter 25 APM•25 Modulescan he newer:aced on a singleOre !ouch Control Panelieff.. R31-24 Refrigerant Gas Oates: or IAPM-751Module• clOi-24 Point detectorA.191 Floorgag ,_10APh1-2-5msdkkleARM Link,10.0; 111—15C iimr1.Wien l task Eictortert 2nd 1109iMale Talot • mar IISM. Itouch 5treenMonitorcrnnerhselThCP1.1-1{1011Processing !ArcAPIA-25ModuleStage 2Upto}51-7oneCeetrat Panel;cent* nelonokedon a tingleOne I ourh Control PanelCoolly!PIMA_ REA-111, Nefhile.11f11rElkt lifl.PefEd511}i-7d Pnirt n a;;;410;_ 3rd Flowi-Zone Control Panels connected toOne-Touch) System. showing alarmcondition on local panel and floor,zone and graphic map orOne-Touch SW-ern.kneikril 4.7ber coricrol ParbrlA rriaximura of 25 detectors of ary ,r>04relinhinatiesn rsnb rcrinweloalaumidity7M rcrnrWelDe.lectodZara Onezild.F7cle rrMahe LinkLLISI-24 Ns 4_17-xWE[Ef USIK.:1011 tablewater Leo* Omura:, ]rid FlourMale Toler - ZonalControl Panel71 M•SPO ncoduteand up nrrn-n rim wind CINr•attilt-24rerripereltafe01411fC:CIN111picOr.1J _•-..PIM•1Touch 5 creen MonitorrrrirnwE had I ri rPi egnPro, rzeincp UnitcoYen Free-CoeTads, and I:15 485la-Came27
  28. 28. IJDH-24UDF-24IFloat Detector. Humidity Detector.mciLralarrn Universal DetectorsJAM offer a range of detectors that can be linked directly onto other control systems, i.e. BMS systems, ACcontrols or any control system that can provide a 24v power supply {ac or tic) and receive a volt free signalin the condition of alarm, which we categorise under Universal Detectors.The Universal Detectors do not require an "Aqua!arm control panel to monitor them.All the detectors that are shown within this product guide are available in this format. The alarm voltfree signal can be raised in either a Normally Open {h1.0.} or Normally Closed (N.C.) condition.Detectors CD-x Water Detecting CablesUDP-211. UDOF-24Point of use Detector. Overflow Detector.Detecting Cable complete with maleffernaleconnections.FCD-1CD-2CD-5CD-101 metre2 metre5 metre10 metreCode: 6004Code 6005Code 6005Code. 6007UDC-24 UDR-24gene tvladule. Refrigerarrt LeakDetector.The model numbers for the Universal Versionof each detectors are as follows:U D111-24 UDT-24Point of use Infra Red 2 Stage TemperatureDetector. Detector.Detector Description Model NumberPoint of usawaterdetector UDP-241Cable zone detector module UDC-.241Detection cable CD-xInfra-Red detector {oil or diesel) UDIN-24Float detector U0P-24Overflow detector UOOF-24Refrigerant gas detector UDR-24Temperature detector UDT-24Humidity detector UGH-2426
  29. 29. Air -siia—PeJ.A.M. Limited is an 1509001 & 14001 registered company.TechnologyAll our electronics and components are Rol-1S Compliant in line with currentlegislation. Our PCBs are multi-layered and are PTH manufactured to meetUL Standards. All our finished products are Cr marked.EnvironmentOur CredentialsAs pa rt of the governments WEEE Directive, J.A.M. Limited are registered for thesafe disposal of electronic component waste, which is recycled. Using this procedureallows us to offer disposal of any redundant systems to our clientfenct users.J.A.M. Limited ensures that any of our metal enclosures that are either damaged ordo not meet our production standards, are returned to our fabricator for recycling,„if rf1.15141.1500001 WEEQ Mof ISO 141)01 W&HFull size copies can be found on our website, wwwjarn,uk,corn33
  30. 30. D or HBDL, 200Lulation Jacketcilities www.holroydcomponents.comTechnical DatasheetConstruction:High performance ceramic fibre thermal insulation containedwithin layers of Teflon coated polyester give the jacket a durableand industrial feel.Easy to fit with Velcro fixing strips and a moveable flap for easeof access makes the HIJD jacket the most convenient way tokeep your products warm.Technical Data:Jacket Material: 1100 deitex texturised NylonPolyurethane coatedInsulation: Glass filament blanketFixing: Velcro FixingCustom Made:All HIJD heater jackets are manufactured to conform to the EEClow voltage and EMC directives and CE marked accordingly.Health and Safety:All HIJD heater jackets are manufactured to conform to the EEClow voltage and EMC directives and CE marked accordingly.Tel: +44 (0)191 490 1547Fax: +44 (0)191 477 5371Email: northernsales@thorneandderrick.co.ukWebsite: www.heattracing.co.ukwww.thorneanderrick.co.uk

×