Your SlideShare is downloading. ×
Asco Em WSEM Atex Iec ex Flameproof Explosion Proof Operator Hazardous Area Solenoid Valve Operator Ex Emb Operator Zone 1 Zone 2
Asco Em WSEM Atex Iec ex Flameproof Explosion Proof Operator Hazardous Area Solenoid Valve Operator Ex Emb Operator Zone 1 Zone 2
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Asco Em WSEM Atex Iec ex Flameproof Explosion Proof Operator Hazardous Area Solenoid Valve Operator Ex Emb Operator Zone 1 Zone 2

212

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
212
On Slideshare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. OPERATORS Series for potentially explosive atmospheres increased safety/encapsulation II 2 G Ex emb II T6..T3, II 2 D Ex tD A21 IP67 steel or stainless steel enclosure EM WSEM FEATURES • Explosionproof operator for use in potentially explosive atmospheres according to ATEX-Directive 94/9/EC EC type examination certificate no.: KEMA 98 ATEX 2542 X IECEx Certificate of Conformity no.: IECEx KEM 08.0002X • Compliance with the Essential Health and Safety Requirements has been assured by compliance with the International and European Standards EN-IEC 60079-0, EN-IEC 60079-7, EN-IEC 60079-18, EN-IEC 61241-0 and ENIEC 61241-1 • Easy electrical installation by means of a screw terminal coil • Peak voltage suppression standard for DC executions • Enclosure provided with integral strain relief for cable with an o.d. of 7 to 12 mm • Ingress protection degree IP67 • A wide range of valves can be supplied with the operator CONSTRUCTION Solenoid enclosure EM Zinc plated steel (epoxy coated) WSEM Stainless steel, AISI 316 PA, M20 x 1,5 Stainless steel Copper or silver Polyester Embedded screw terminals II 2 G Ex emb II T6..T3 q II 2 D Ex tD A21 IP67 T 85°C to T 200°C Cable gland Core, core tube and plugnut Shading coil Nameplate Coil connection Safety code ELECTRICAL CHARACTERISTICS Standard voltages (Other voltages and 60 Hz on request) DC (=) : 24V - 48V AC (~) : 24V - 48V - 115V - 230V / 50 Hz EM TEMPERATURE CLASSIFICATION TABLES solenoid size (watt) M6 MXX M12 Pn DC (=) solenoids maximum ambient °C (1) surface temperature 00135GB-2010/R02 Availability, design and specifications are subject to change without notice. All rights reserved. T6 T5 T4 T3 85°C 100°C 135°C 200°C insulation class F (155°C) 100% E.D. 1,2 (2) 1,5 (2) 1,9 (2) 3,7 (2) 5,8 (2) 6,0 9,0 10,0 (2) 10,0 (2) 10,5 13,0 13,6 (2) 14,1 (2) 16,5 • • • • • • • • • • • • • • 60 40 40 40 75 55 55 55 40 90 75 40 90 40 40 40 65 40 40 40 40 40 solenoid size Pn (watt) maximum ambient °C (1) surface temperature M6 MXX M12 AC (~) solenoids T6 T5 T4 T3 85°C 100°C 135°C 200°C insulation class F (155°C) 100% E.D. 1,3 1,7 1,8 3,6 5,7 9,7 10,0 11,2 14,0 15,3 16,8 19,7 23,0 • • • • • • • • • • • • • 60 40 40 40 75 55 55 75 40 WSEM 90 75 40 90 40 65 40 40 40 40 40 50 ORDERING INFORMATION A valve supplied with the explosionproof operator will be identified with prefix EM or WSEM before the catalogue number. Example: WSEM E 210D095 230V/50 Hz EM E 210D095 230V/50 Hz operator pipe thread voltage basic number Check the wattage compatibility with the product selected. The minimum allowable ambient temperature is -40°C for the operator. Actual temperature range can be limited depending on valve operation limits. (2) AC (~): rectified coil construction. (1) CONNECTIONS • Internal and external earthing connection • The operator can be rotated through 360° to select the most favourable position for cable entry OPTIONS • Brass nickel plated or stainless steel cable gland • Conduit hub, 1/2 NPT, M20 x 1,5, 3/4 NPT or M25 x 1,5 in aluminium or stainless steel • Special moulded-in solid state components for peak voltage suppression and/or rectification (four-diode bridge) Tel: +44 (0)191 490 1547 All leaflets (0)191 477 5371 www.asconumatics.eu Fax: +44 are available on: Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk V1047-1 www.thorneanderrick.co.uk I
  • 2. OPERATORS SERIES EM/WSEM DIMENSIONS (mm), WEIGHT (kg) TYPE EM/WSEM Prefix "EM"/"WSEM" solenoids Pull-type solenoid operator Metal enclosure, epoxy coated or stainless steel EN-IEC 60079-7, EN-IEC 60079-18 and EN-IEC 61241-1 II 2 G Ex e mb II - II 2 D Ex tD A21 IP67 prefix/size EM/WSEM-M6 EM/WSEM-MXX EM/WSEM-M12 A 77 77 77 B 120 120 120 C 82 82 82 D 26 23 21 E 64 62 65 weight 0,48 0,55 0,67 TYPE EM/WSEM prefix/size EM/WSEM-M6 EM/WSEM-MXX EM/WSEM-M12 A 77 77 77 B 120 120 120 C 82 82 82 D 25 31 30 E 63 69 73 weight 0,50 0,59 0,70 TYPE EM/WSEM Prefix "EM"/"WSEM" solenoids Pull-type solenoid operator Metal enclosure, epoxy coated or stainless steel EN-IEC 60079-7, EN-IEC 60079-18 and EN-IEC 61241-1 II 2 G Ex e mb II - II 2 D Ex tD A21 IP67 prefix/size EM/WSEM-MXX A 77 B 120 C 82 D 23 E 80 All leaflets are available on: www.asconumatics.eu V1047-2 weight 0,68 Tel: +44 (0)191 490 1547 Fax: +44 (0)191 477 5371 Email: northernsales@thorneandderrick.co.uk Website: www.heattracing.co.uk www.thorneanderrick.co.uk 00135GB-2010/R02 Availability, design and specifications are subject to change without notice. All rights reserved. Prefix "EM"/"WSEM" solenoids Push-type solenoid operator Metal enclosure, epoxy coated or stainless steel EN-IEC 60079-7, EN-IEC 60079-18 and EN-IEC 61241-1 II 2 G Ex e mb II - II 2 D Ex tD A21 IP67

×