TBIZ 2012- APC by Schneider Electric. Struxure ware for data centers-v1
Upcoming SlideShare
Loading in...5
×
 

TBIZ 2012- APC by Schneider Electric. Struxure ware for data centers-v1

on

  • 1,025 views

 

Statistics

Views

Total Views
1,025
Views on SlideShare
1,008
Embed Views
17

Actions

Likes
0
Downloads
8
Comments
0

1 Embed 17

http://www.technologybiz.it 17

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

TBIZ 2012- APC by Schneider Electric. Struxure ware for data centers-v1 TBIZ 2012- APC by Schneider Electric. Struxure ware for data centers-v1 Presentation Transcript

  • StruxureWare for Data CentersGestione integrata per il massimorisparmio energeticoAntonio RacioppoliSystem Engineer and Project Manager
  • ContentsSchneider Electric OverviewDCIM Market TrendsStruxureWare for Data CentersROI EstimationTradeOff ToolsTMQuestions & Answers
  • Schneider Electric Overview
  • Oltre 175 anni di storia 2010 Acquisizione di Uniflair 1999 2009 Il gruppo Schneider diventa Acquisizione di Areva T&D Schneider Electric, 2008 con focus su Power & Control Acquisizione di Xantrex 1996 2007 Modicon, leader storico nel Acquisizione di mondo dell’Automazione APC e Pelco diventa un brand Schneider 2005 Acquisizione di 1991 Power Measurement Inc. Square D entra a far parte 2003-2008 del Gruppo Schneider Acquisizioni mirate nel mercato 1988 home automation e domotica Telemecanique diventa un (Lexel,Clipsal, Merten,Ova,GET) brand del Gruppo Schneider 2003 Acquisizione di T.A.C1836 1975 2000Nascita di Schneider Merlin Gerin entra a far parte Acquisizione di MGE UPSA Creusot, Francia del Gruppo Schneider Systems 19°Secolo 20°Secolo 21°Secolo
  • Oltre 175 anni di storia 2010 GestioneAcquisizione di Uniflair 1999 dell’Energia 2009 Power & Il gruppo Schneider diventa Acquisizione di Areva T&D Schneider Electric, 2008 Control con focus su Power & Control Acquisizione di Xantrex 1996 2007 Modicon, leader storico nel Acquisizione di mondo dell’Automazione APC e Pelco diventa un brand Schneider 2005 Acquisizione di 1991 Power Measurement Inc.Industria Square D entra a far parte 2003-2008 del Gruppo Schneider Acquisizioni mirate nel mercato 1988 home automation e domotica Telemecanique diventa un (Lexel,Clipsal, Merten,Ova,GET) brand del Gruppo Schneider 2003 Acquisizione di T.A.C1836 1975 2000Nascita di Schneider Merlin Gerin entra a far parte Acquisizione di MGE UPSA Creusot, Francia del Gruppo Schneider Systems 19°Secolo 20°Secolo 21°Secolo
  • Abbiamo scelto un posizionamento unicoin un settore strategico per il futuro specialista globale gestione dell’energia produzione e per rendere l’energia: trasmissione energia utilizzo energia sicura affidabile infrastrutture industria solare eolica efficiente combustibili fossili produttiva buillding consumo mondiale sostenibile datacenteridrica residenziale nucleare
  • In Italia: Schneider Electric ha unapresenza storica importante milioni fatturato dipendenti aree commerciali siti industriali una presenza capillare sul territorio centro assistenza clienti unico per tutte le necessità tecniche e amministrative centro logistico integrato
  • DCIMMarket Trends
  • Business Benefits It is difficult to achieve the more advanced levels of datacenter maturity, or of datacenter effectiveness generally, without extensive use of DCIM software (451 Group, 2011) Energy savings from well-managed data centers can reduce operating expenses by as much as 20% (Gartner, 2010) One integrated system bridging the gap between Facilities and IT Plug’n’Play data center key performance indicators on web and smart phone dashboards Typical solution payback is less than 12 months
  • Schneider, a leader in the DCIM market“According to IDC analysis and buyer perception, Schneider Electric is an IDC MarketScape Leader worldwide.” ”IDC: MarketScape: Worldwide Datacenter Infrastructure Management (DCIM) 2011 Vendor Analysis” Katherine Broderick, IDC January 2012
  • StruxureWare for Data Centers
  • Schneider Electric’s DCIM Solutions Resource Advisor Data Center Building Operation Operation Power Monitoring Expert Data Center Expert A suite of modular and integrated DCIM software tools that enable effective data center management
  • StruxureWare for Data Centers
  • StruxureWare for Data Centers Software Suite Capacity Energy Cost Energy Change IT Optimize Efficiency •IT Power/Usage •AutomatedStruxureWare •Capacity analysis & planning •Energy usage workflow Mgmt Monitoring (Charge •Charge back •PUE analytics back)Data Center Expert •Equipment •Subsystem •Scheduling of changes •Underutilized placement Servers track analysis •Maint Tasks •IT autodiscovery•Real-Time CentralizedMonitoring•Advanced AlarmConfiguration StruxureWare Data Center Operation•Reporting•Full SDK •Inventory management•3°Party Devices Integration •Real-time device failures shown in physical layout •Location-based drill-down •PUE calculator StruxureWare Building Operation
  • StruxureWare for Data Centers Business Continuity StruxureWare OperationsVirtual machine Physical infrastructure manager InfrastruXure manager Operations StruxureWare Central Virtualized servers automatically move based on Power & Cooling Critical Status
  • ROI Estimation
  • ROI Estimation 100kW Data Center Inputs Units Total Number of Racks 40 Racks Monthly utility bill 13.000 EUR Original PUE 2,0 PUE Target PUE 1,4 PUE Minutes of downtime in the past 12 months 10 Minutes Cost for minute of downtime in EUR 1000 EUR Your potential net savings over a five-year period: 263.600 EUR
  • ROI Estimation 100kW Data Center Inputs Units Total Number of Racks 40 Racks Monthly utility bill 13.000 EUR Original PUE 2,0 PUE Target PUE 1,4 PUE Minutes of downtime in the past 12 months 10 Minutes Cost for minute of downtime in EUR 1000 EUR Results ROI Table Year 1 Year 2 Year 3 Year 4 Year 5 Total Net Savings -6.200 54.400 62.300 71.400 81.700 263.600 Solution Cost 59.600 6.000 6.000 6.000 6.000 83.600 Gross Savings 53.400 60.400 68.300 77.400 87.700 347.200 Downtime Cost Savings 6.000 6.867 7.859 8.995 10.295 40.016 Energy Cost Savings 23.400 25.506 27.802 30.304 33.031 140.042 Labor Cost Savings 24.000 27.991 32.646 38.075 44.407 167.120
  • TradeOff Tools TM
  • Schneider Electric TradeOff Tools™ Simple, automated tools to support specific planning decisions Models complex interactions of systems based on data and science One-screen, standardized user interface Instant output allows for rapid creation of “what if” scenarios
  • Questions and Answers