Digi-Pas TM                                             Digi-Pas TM Digital Level                                         ...
Upcoming SlideShare
Loading in …5
×

DigiPas Digital Pocket Level (DWL80E) -www.DIGIPAS.co.uk

1,195 views

Published on

Published in: Self Improvement
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
1,195
On SlideShare
0
From Embeds
0
Number of Embeds
3
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

DigiPas Digital Pocket Level (DWL80E) -www.DIGIPAS.co.uk

  1. 1. Digi-Pas TM Digi-Pas TM Digital Level Applications A Ventura Group of Companies ON/OFF: Turn on/off device USER MANUAL LCD Digital Display DIGITAL LEVEL DWL80E (0.1° Resolution) Aluminium Structure ® Registered Design Alternate Zero Magnet Vial MODE: Select 0.1° or % Freeze Display CAL: Calibrate the device value & store the calibration value Product of Singapore value in the memory ® Registered DesignCALIBRATION INSTRUCTIONS CALIBRATION PICTURE For first time usage, remove the plastic strip to WARRANTY connect the battery. STEP 1 The Digi-Pas™ Digital level is warranted to the original1.(a). Push Once on the CAL button, “CAL 1” blinks. purchaser to be free from defects in workmanship and material. JSB Tech will, at its option, repair or replace any detective part (b). Place DWL80E on a flat & clean surface which may malfunction under normal and proper use within a (e.g. Table) period of 1 (one) year from the date of shipment. The foregoing warranty shall not apply to defects resulting from misuse, abuse or transfer by the Buyer, Buyer-supplied software or interfacing,2.(a). Press MODE, display counts down from unauthorized modification or operation outside of environmental E.g Table Surface Push Once “ CAL” 10,9,8.......1, “CAL 2” blinks. specifications for the product. JSB Tech does not warrant that the operation of the instrument software, or firmware, will be (b). Place DWL80E reverse horizontal (180°) Press STEP 2 uninterrupted or error free. The exclusive remedy under any and all warrants and guarantees, expressed herein, and we shall MODE, display counts down, “CAL 3” blinks. a. not be liable for damages from loss or delay of equipments uses, CAL consequential, or incidental damage. No other warranty is (c). Place DWL80E vertically (-90°). Press MODE expressed or implied. JSB Tech specifically disclaims the button, display counts down, “CAL 4” blinks. implied warranties of merchantability and fitness for a particular purpose. (d).Place DWL80E reverse vertically (+90°). Press Press Mode button Once MODE button, display counts down. b. 180° CALIBRATION DONE.NOTE: Ensure DigiPas device is kept still duringcalibration. CAUTION c. 90° 90° Manufactured by JSB TECH Pte LtdDigiP as device is calibrated in the factory for Press Mode button Oncemaximun accuracy. User can re-calibrate when Press Mode button Once CALnecessary. Remove Screw to remove battery from the Tel: 65-67780640 / Fax: 65-67770460 Email: jsb-sales@jsbtech.com compartment www.digipas.com

×