  • 1. Technische Universität Darmstadt | FG ee | El-Lissitzky--Str. 1 | 64287 DarmstadtDeliverables June, 2nd 2009Project Manual Department of ArchitectureProject Manual Unit of Energy Efficient Building Design Prof. Manfred Hegger El-Lissitzky-Straße 1 64287 Darmstadt phone. +49 6151 16 - 2046 fax +49 6151 16 - 5247 henrich@ee.tu-darmstadt.de June, 2nd 2009 www.solardecathlon2009.de ee Seite: 1/127
  • 2. Table of Contents1.  Summary Of Changes ........................................................................................... 6 2.  Rules Compliance Checklist .................................................................................. 7 3.  Construction specifications ................................................................................. 11  00  Procurement and Contracting Requirements ..................................... 11  01  General Requirements........................................................................ 23  01 53 00 Temporary Construction ............................................................. 23  01 54 00 Construction Aids ........................................................................ 25  01 54 23 Temporary Scaffolding ................................................................ 27  01 65 00 Product Delivery Requirements ................................................... 28  02  Existing Conditions - no entries ....................................................... 28  03  Concrete - no entries ........................................................................ 28  04  Masonry - no entries ........................................................................ 28  05  Metals ................................................................................................ 29  05 05 23 Metal Fastening ........................................................................... 29  05 14 00 Structural Aluminum Framing .................................................... 30  05 20 00 Metal Joists ................................................................................. 31  05 25 00 Aluminum Joist Framing ............................................................. 33  05 25 00 Aluminum Joist Framing ............................................................. 33  06  Wood, Plastics, and Composites ......................................................... 34  06 05 00 Common Work Results for Wood, Plastics and Composites ........ 34  06 11 00 Wood Framing............................................................................. 36  06 12 00 Structural Panels ......................................................................... 37  06 16 00 Sheathing .................................................................................... 38  06 17 33 Wood I-Joists ............................................................................... 39  06 40 00 Architectural Woodwork ............................................................. 40  06 60 00 Plastic Fabrications...................................................................... 41  06 60 00 Plastic Fabrications...................................................................... 41  07  Thermal and Moisture Protection ...................................................... 42  07 21 00 Thermal Insulation ...................................................................... 42  07 25 00 Weather Barriers ......................................................................... 44  07 26 00 Vapor Retarders .......................................................................... 45  07 55 00 Protected Membrane Roofing ...................................................... 46  Seite: 2/127
  • 3. 07 62 00 Sheet Metal Flashing and Trim ................................................... 47 07 71 23 Manufactured Gutters and Downspouts ...................................... 48 07 90 00 Joint Protection ........................................................................... 49 08  Openings ............................................................................................ 50 08 10 00 Doors and Frames ....................................................................... 50 08 50 00 Windows ..................................................................................... 51 08 70 00 Hardware .................................................................................... 53 08 80 00 Glazing ........................................................................................ 54 09  Finishes .............................................................................................. 55 09 20 00 Plaster and Gypsum Board .......................................................... 55 09 60 00 Flooring ....................................................................................... 56 09 80 00 Acoustic Treatment ..................................................................... 58 09 90 00 Painting and Coating ................................................................... 59 10  Specialties .......................................................................................... 60 10 28 00 Toilet, Bath, and Laundry Accessories ......................................... 60 10 70 00 Exterior Specialties ...................................................................... 61 11  Equipment .......................................................................................... 62 11 30 00 Residential Equipment ................................................................ 62 12  Furnishings ........................................................................................ 63 12 30 00 Casework ..................................................................................... 63 12 40 00 Furnishings and Accessories ........................................................ 64 12 50 00 Furniture ..................................................................................... 66 13  Special Construction .......................................................................... 66 14  Conveying Equipment ........................................................................ 67 14 80 00 Scaffolding .................................................................................. 67 21  Fire Suppression................................................................................. 67 22  Plumbing ............................................................................................ 68 22 10 00 Plumbing Piping and Pumps ....................................................... 68 22 40 00 Plumbing Fixtures ....................................................................... 70 23  HVAC ................................................................................................. 72 23 30 00 HVAC Air Distribution ................................................................. 72 23 50 00 Central Heating Equipment ......................................................... 74 23 70 00 Central HVAC Equipment ............................................................ 75 24  --- ....................................................................................................... 75  Seite: 3/127
  • 4. 25  Integrated Automation ....................................................................... 76 25 30 00 Integrated Automation Instrumentation and Terminal Devices .. 76 26  Electrical ............................................................................................ 78 26 05 00 Common Work Results for Electrical ........................................... 78 26 20 00 Low-Voltage Electrical Distribution ............................................. 79 26 30 00 Facility Electrical Power Generating and Storing Equipment ...... 81 26 50 00 Lighting ....................................................................................... 83 27  Communications ................................................................................ 84 27 40 00 Audio-Video Communications ..................................................... 84 28  Electronic Safety and Security ........................................................... 86 28 05 00 Common Work Results for Electronic Safety and Security .......... 86 28 30 00 Electronic Detection and Alarm................................................... 87 29  --- ....................................................................................................... 88 30  --- ....................................................................................................... 88 31  Earthwork .......................................................................................... 88 32  Exterior Improvement ........................................................................ 88 33  Utilities............................................................................................... 88 34  Transportation ................................................................................... 88 35  Waterway and Marine Construction .................................................. 88 36  --- ....................................................................................................... 88 37  --- ....................................................................................................... 88 38  --- ....................................................................................................... 88 39  --- ....................................................................................................... 88 40  Process Integration............................................................................. 88 41  Material Processing and Handling Equipment ................................... 88 42  Process Heating, Cooling, and Drying Equipment .............................. 89 42 31 16 Dessicant Equipment ................................................................... 89 43  Process Gas and Liquid Handling, Purification, and StorageEquipment .................................................................................................. 89 44  Pollution Control Equipment ............................................................. 89 45  Industry-Specific Manufacturing Equipment ...................................... 89 46  --- ....................................................................................................... 89 47  --- ....................................................................................................... 89 48  Electrical Power Generation ............................................................... 90  Seite: 4/127
  • 5. 48 10 00 Electrical Power Generation Equipment ...................................... 90 4.  Structural Calculations ....................................................................................... 91 5.  Detailed Water Budget........................................................................................ 92 6.  Summary of Unlisted Electrical Components ...................................................... 92 7.  Retail PV Price Quote(s) ..................................................................................... 95 8.  Summary of reconfigurable features ................................................................... 97 9.  Interconnection Application Form .................................................................... 100 10.  Energy Analysis Results and Discussion ............................................................ 101 11.  Subjective Contest Support Documents ............................................................ 112 11.1.  Architecture Design Narrative ..................................................................... 112 11.2.  Market Viability Justification ...................................................................... 117  Construction ............................................................................................. 117  Liveability ................................................................................................. 117  Marketability ............................................................................................ 118 11.3.  Engineering Design Narrative ..................................................................... 121 11.4.  Lighting Design Narrative ........................................................................... 126  Seite: 5/127
  • 6. 1. Summary Of ChangesSince the last deliverables in December 2008 and the following workshop inWashington D.C. in January 2009 the complete set of ConstructionDocuments of Team Germany has been revised.There has been an intensive design and optimization process within the lastmonths bearing several new ideas and possibilities on different layers. Wespent a long time developing a façade with PV-application. Manufacturers andsponsors guided and supported our research and design process for monthsbefore admitting that this idea of a smooth and lightweight façade istechnically not yet producible.The consequence of this development and the most apparent change sinceDecember is that our façade had to become a new design. It is now a newinterpretation of our ideas for a PV-activated façade which should be easilyconceivable for other projects and adaptable for energetic renovations ofbuilding stock. (See also Architecture and Engineering Design Narratives)Other particular changes since December insist on our ceiling system that isnow a crucial component of our energy concept. The window’s positions havechanged due to further analysis and light-studies – attended by furtheranalysis concerning effective sun control devices.Relating to the Rules Compliance Checklist the following changes have beenmade:4-5 noise reduction for equipment5-2 effect of reconfigurable louvers integral to the façade’s structure necessary revision of solar envelope6-4 new public tour route due to crossing points in December’s proposal8-3 cooling system integral to void ceiling8-6 changed from 3-phase system to required 1-phase system for Photovoltaic connection Façade9-6 effects of cooling system integral to void ceiling Seite: 6/127
  • 7. 2. Rules Compliance ChecklistRule Drawing Sheet(s) Coordinate Rule Description Content Requirement(s) # s Drawing(s) showing the assembly O-210/O-229 and disassembly sequences and the O-310 4-2 Construction Equipment movement of heavy machinery on the competition site No forklifts, or 4-2 Construction Equipment Specs for heavy machinery similar planned Drawing(s) showing the locations S-206, S-553, 4-3 Ground Penetration and depths of all ground S-554 penetrations on the competition site Drawing(s) showing the location, S-206 contact area, and soil bearing 4-4 Impact on the Turf pressure of every component resting directly on the turf PM: 26 32 00 4-5 Generators Specifications for generators Specs Drawing(s) showing the locations of P-111, P-211, all equipment, tanks, and pipes that P-311, P-411, 4-6 Spill Containment will contain fluids at any point P-421, P-431 during the event PM: 22 10 00 Specifications for all equipment, Specs 4-6 Spill Containment tanks, and pipes that will contain PM: 33 16 00 fluids at any point during the event Specs Calculations showing that structural S-301 design remains compliant even if 18 4-7 Lot Conditions in. (45.7 cm) of vertical elevation change exists Drawing(s) showing shimming S-301 methods and materials to be used if 4-7 Lot Conditions 18 in. (45.7 cm) of vertical elevation change exists on the lot Drawing(s) showing the location of L-641 Solar Envelope 5-2 all house and site components Dimensions relative to the solar envelope List of solar envelope exemption No exemption Solar Envelope requests accompanied by requests 5-2 Dimensions justifications and drawing references Seite: 7/127
  • 8. List of, or marking on, all sheets in S-201 – S-206 the complete electronic S-301 – S-303 Construction Documents that have S-401 – S-408 been or will be stamped by the structural engineer in the hard- Structural Design6-1 copy, stamped structural Approval submission; the stamped submission shall consist entirely of sheets or pages that also appear in the complete electronic construction document set Drawing(s) showing all information A-223 Maximum Architectural needed by the Rules Officials to6-2 Footprint measure the architectural footprint electronically Drawing(s) showing all movable A-225 Maximum Architectural components that may increase the6-2 Footprint footprint if operated during contest week Shading calculations and/or A-225 diagrams for components that DO NOT shade the building above its finished floor height between 9 a.m. and 5 p.m. EDT on October 1 Maximum Architectural6-2 (shading calculations and/or Footprint diagrams are not necessary for components that are either shorter than finished floor height or obviously do not shade the building) Drawing(s) showing space A-224 Minimum Conditioned6-3 conditioning means in primary Space living spaces Drawing(s) showing the accessible X-211, X-311 public tour route and the ground X-312, X-511 Entrance and Exit6-4 surface area that will be covered by Routes organizer-provided walkway material Drawing(s) showing the location of L-511 all vegetation and, if applicable, the7-1 Placement movement of vegetation designed as part of an integrated mobile system Drawings showing the layout and P-511, P-5217-2 Watering Restrictions operation of greywater irrigation P-531, P-541 systems P-551 PM: 26 31 00 PV Technology Specifications for photovoltaic Specs PV8-1 PM: 38 19 16 Limitations components Specs Inverters PV Technology Retail price quote for photovoltaic Retail PV Price8-1 Quotes Limitations components Seite: 8/127
  • 9. Drawing(s) showing the location of M-2318-3 Thermal Energy Storage thermal energy storage components Specifications for thermal energy PM: 23 56 008-3 Thermal Energy Storage Specs storage components Shading calculations and/or PM: 08 50 00 Specs8-3 Thermal Energy Storage diagrams for thermal energy storage components (if necessary) Drawing(s) showing the location(s) No batteries used8-4 Batteries and quantity of stand-alone, PV- powered devices Specifications for all stand-alone, No batteries used8-4 Batteries PV-powered devices Drawing(s) describing the operation M-2228-5 Desiccant Systems of the desiccant system Specifications for desiccant system PM: 23 56 008-5 Desiccant Systems PM: 42 31 16 components Interconnection Completed Interconnection8-6 Village Grid Application Application form. Form Drawing(s) showing the locations of A-225 A-841, A-842, the photovoltaics, inverter(s), A-844, A-8528-6 Village Grid terminal box, meter housing, service equipment, and grounding means Specifications for the photovoltaics, PM: 26 31 00 Specs PV inverter(s), terminal box, meter8-6 Village Grid PM: 38 19 16 housing, service equipment, and Specs Inverters grounding means8-6 Village Grid One-line electrical diagram E-506 Calculation of service/feeder net E-501, E-502,8-6 Village Grid computed load per NEC 220 E-503, E-504 Site plan showing the house, decks, L-5118-6 Village Grid ramps, tour paths, and terminal box Elevation(s) showing the terminal L-641, L-642 box, meter housing, main utility8-6 Village Grid disconnect, and other service equipment Drawing(s) showing the layout and A-8439-4 Rainwater Collection operation of rainwater collection systems Drawing(s) showing the locations of M-321 – M-3519-6 Thermal Mass water-based thermal mass systems Specifications for components of PM: 23 71 139-6 Thermal Mass Specs water-based thermal mass systems Drawing(s) showing the See: TUD_FINALCO Event Sponsor dimensions, materials, artwork, and10-2 MMPLAN_2009 Recognition content of all communications -06-02 materials, including signage Seite: 9/127
  • 10. Drawing(s) showing the See: TUD_FINALCO Team Sponsor dimensions, materials, artwork, and10-3 MMPLAN_2009 Recognition content of all communications -06-02 materials, including signage Interior and exterior plans showing X-211, X-311,11-4 Public Exhibit X-312, X-511 entire accessible tour route Drawing(s) showing the Not yet designed11-4 Public Exhibit dimensions, materials, artwork, and content of the handout See: Drawing(s) showing the artwork TUD_FINALCO11-4 Public Exhibit MMPLAN_2009 and content of the team uniform -06-02 Seite: 10/127
  • 11. 3. Construction specifications00 Procurement and Contracting Requirements00 01 01 Project Title PageTitle: TEAM GERMANY SOLAR DECATHLON 2009 | Technische Universität DarmstadtDate: April 2008 – October 2009Construction Site:Petersenstrasse; 64287 Darmstadt;Parking Area between Cafeteria TU Lichtwiese and Department of ArchitectureStudent Team:Leader internal: Annika Gaigl | a.gaigl@solardecathlon2009.deLeader external: Sardika Meyer | s.meyer@solardecathlon2009.deFaculty Advisors:Architecture: Professor Manfred Hegger | hegger@ee.tu-darmstadt.deOrganization: Dipl.-Ing. Johanna Henrich | henrich@ee.tu-darmstadt.de Dipl.-Ing. Jörg Wollenweber | wollenweber@ee.tu-darmstadt.deCommunications: Dipl.-Ing. M.A. Caroline Fafflok | fafflok@ee.tu-darmstadt.deDesign and Engineering: Dipl.-Arch. Hans Drexler | Dipl.-Ing. Martin ZeumerElectr. Engineering: Dipl.-Ing. Lutz Steiner | steiner@re.tu-darmstadt.deStruct. Engineering: Dipl.-Ing. Jochen Stahl | stahl@baustatik.tu-darmstadt.deTeam Germany Website, including Blog and Live-Webcam:http://www.solardecathlon2009.deTeam Germany Contact:team@solardecathlon2009.de Seite: 11/127
  • 12. 00 01 15 List of Drawing SheetsGeneralG - 101 - Cover SheetG - 102 - Table of ContentG - 103 - Table of ContentG - 104 - Table of ContentG - 105 - Table of ContentG - 106 - Table of ContentG - 201 - Design ConceptG - 202 - Strategies Of Energy UseG - 203 - Sustainable DesignG - 204 - Symbols And NotesG - 301 - AbbreviationsG - 401 - Target Market DescriptionG - 501 - Exterior Rendering - South EastG - 502 - Exterior Rendering - South WestCivilC - 201 - Site 1:50C - 301 - Grading 1:50LanscapeL - 111 Symbols and Notes 1:50L - 211 Grading 1:100L - 321 Secondary Construction 1:100L - 322 Planking 1:100L - 351 Deck Construction Detail 1:100L - 411 Lighting Design 1:100L - 511 Planting 1:100L - 641 Elevation - North East 1:50L - 642 Elevation - South West 1:50L - 711 Schedules - LandscapeL - 712 Schedules - LandscapeL - 713 Schedules - LandscapeL - 714 Schedules - LandscapeStructural - GeneralS -101 - General NotesS -102 - General NotesS -103 - General NotesS -104 - General NotesStructural - PlansS - 201 - Roof Framing 1:50S - 202 - Upper Wall Framing 1:50S - 203 - 2nd Floor Framing 1:50S - 204 - Floor Framing 1:50S - 205 - Platform Framing 1:50S - 206 - Foundation Plan 1:50 Seite: 12/127
  • 13. Structural - SectionsS - 301 - Longitudinal Section 1:50S - 302 - Cross Section 1:50S - 303 - Cross Section 1:50Structural - ElevationsS - 401 - Wall Construction North 1:50S - 402 - Wall Construction East 1:50S - 403 - Wall Construction South 1:50S - 404 - Wall Construction West 1:50S - 405 - Wall Sheathing North 1:50S - 406 - Wall Sheathing East 1:50S - 407 - Wall Sheathing South 1:50S - 408 - Wall Sheathing West 1:50Structural - VIPS - 421 - VIP Floor Plan 1:50S - 422 - VIP Roof Plan 1:50S - 441 - VIP Plan North 1:50S - 442 - VIP Plan East 1:50S - 443 - VIP Plan South 1:50S - 444 - VIP Plan West 1:50S - 451 - VIP Structure 1:7S - 461 - Schedules - VIPStructural - DetailsS - 511 - Wall to Roof Connection E-W 1:5S - 512 - Wall to Roof Connection 1:5S - 513 - Post to Beam Connection 1:5S - 521 - Module Connection 1:5S - 522 - Module Connection S-E Corner 1:5S - 523 - Module Connection S-W Corner 1:5S - 524 - Module Connection N-W & N-E Corner 1:5S - 525 - Built-up Column GL 5 North 1:10S - 526 - Built-up Column GL 8 North 1:10S - 527 - Built-up Column GL 12 North 1:10S - 528 - Built-up Column GL F East 1:10S - 529 - Built-up Column GL 8 South 1:10S - 530 - Built-up Column GL 12 South 1:10S - 531 - Built-up Column GL F West 1:10S - 532 - Roof to Wall Connection Z-Section 1:10S - 533 - Module Connectors @ Corner 1:5S - 534 - Module Connectors @ Corner 1:5S - 535 - Typ- Module Connectors 1:5S - 541 - Steel Edge to Wall Connection 1:5S - 542 - Connection Details of Second Floor 1:5S - 543 - 2nd Floor Edge Angle to Wood Post 1:5ConnectionS - 544 - 2nd Floor Connection @ Split of Building 1:5S - 545 - 2nd Floor Opening for Mechanical 1:5S - 546 - L- section 2nd fl oor North 1:20S - 547 - L- section 2nd fl oor South 1:20 Seite: 13/127
  • 14. S - 548 - 2nd fl oor to East wall connection South 1:20S - 549 - 2nd fl oor to East wall connection center 1:5S - 550 - 2nd fl oor to East wall connection North 1:10S - 551 - 2nd fl oor to North & South wall connection 1:20S - 552 - Holdown Anchor SW Corner 1:10S - 553 - Central Wood Base 1:10S - 554 - Northern Wood Base 1:10S - 555 - Holdown Anchor SE Corner 1:5S - 556 - Holdown anchor SE corner 1:5S - 557 - Details Holdown Anchor 1:5S - 561 - Wall to Floor Connection (West) 1:5S - 562 - Section - Platform Connection 1:5S - 563 - Connection of Steel Beam to Wall 1:5S - 564 - Platform Module Connection 1:5S - 565 - Temp - Bracing @ Platform Connection 1:5S - 566 - Steel Beam to Wall Connection GL 11 1:5S - 567 - Detail - Platform Connection GL 11 1:5S - 568 - Section - Steel Beam @ Stairs 1:5S - 569 - Steel Beam @ Ramp 1:5S - 570 - Post to Steel Beam Connection 1:5S - 571 - Platform Beam Connection 1.5S - 572 - HEA 1 1:20S - 573 - HEA 2 1:20S - 574 - HEA 3 1:20S - 575 - HEA 4 1:20S - 576 - Steel Plate SB2 East & West Wall 1:5S - 577 - Steel Plate SB1 North & South Wall 1:5S - 578 - 2nd Floor Temp- Steel Post 1:20Structural - TransportS - 611 - Axonometry Lower North Module 1:50S - 612 - Axonometry Lower South Module 1:50S - 613 - Axonometry Upper North Module 1:50S - 614 - Axonometry Upper South Module 1:50S - 621 - Floor Plan Lower Modules 1:50S - 622 - Floor Plan Upper Modules 1:50S - 631 - Longitudinal Section E-W 1:50S - 632 - Longitudinal Section W-E 1:50S - 633 - Cross Section N-S 1:50S - 634 - Cross Section S-N 1:50S - 651 - Typ- Trans- Brace To Wall Connection 1:5S - 652 - Trans- Brace To Roof Connection 1:5S - 653 - Trans- Brace To Platform Connection 1:5S - 654 - Threaded Rod To Roof Connection 1:10S - 655 - Cable To Wall Connection 1:5S - 656 - Becket to Platform Connection West 1:10S - 657 - Becket to Platform Connection East 1:10S - 660 - Anchor Overview 1:100S - 661 - Trans- Brace Manufacturer SpecS - 662 - Becket Manufacturer SpecS - 663 - Cable & Tightener Manufacturer Spec-S - 664 - Trans- Brace Platform Anchor West 1:5S - 665 - Trans- Brace Platform Anchor West Rotated 1:5 Seite: 14/127
  • 15. S - 666 - Trans- Brace Platform Anchor East 1:5S - 667 - Trans- Brace Platform Anchor East Rotated 1:5S - 668 - Trans- Brace East & West Wall Anchor 1:5S - 669 - Trans- Brace North Wall Anchor 1:5S - 670 - Trans- Brace Module Bonding Anchor 1:5S - 671 - Trans- Brace South Wall Anchor# 1:5S - 672 - Trans- Brace & Cable Anchor West Wall 1:5S - 673 - Trans- Brace Roof Anchor 1:5S - 674 - Trans- Brace Roof Anchor Rotated 1:5S - 675 - Cable East Wall Anchor 1:5S - 676 - Threaded Rod 1:10S - 677 - Schedule - TransportS - 678 - Schedule - TransportS - 679 - Schedule - TransportStructural - TraverseS - 711 - Floor Plan Traverse 1:20S - 712 - View From Below Traverse 1:20S - 713 - Exploded Drawing 1:20S - 714 - Axonometry TraverseS - 715 - Schedules - Temporary ConstructionArchitectural - PlansA - 221 - Floorplan 1:50A - 222 - 1stFloor 1:50A - 223 - Minimum Conditioned Space 1:50A - 224 - Maximum Architectural Footprint 1:50A - 225 - Moveable Components Shading Deck 1:100Architectural - ElevationsA - 311 - Elevation North 1:50A - 312 - Elevation East 1:50A - 313 - Elevation South 1:50A - 314 - Elevation West 1:50Architectural - SectionsA - 431 - Longitudinal Section - North 1:50A - 432 - Longitudinal Section - South 1:50A - 433 - Cross Section - East 1:50A - 434 - Cross Section - West 1:50Architectural - Details - WindowsA - 510 - Key Plan Windows 1:100A - 511 - Key Plan Windows 1:100A - 520 - Window Elevation North 1:50A - 521 - Window Elevation East 1:50A - 522 - Window Elevation South 1:50A - 523 - Window Elevation West 1:50A - 540 - Window N1 Overview 1:20A - 541 - Window N1 Detail 1 1:20A - 542 - Window N1 Detail 2 1:20A - 545 - Window N2 Overview 1:20A - 546 - Window N2 Detail 1 1:20 Seite: 15/127
  • 16. A - 550 - Window N3 Overview 1:20A - 551 - Window N3 Detail 1 1:5A - 552 - Window N3 Detail 2 1:2A - 553 - Window N3 Lamella -A - 580 - Window SW1 Overview 1:20A - 581 - Window SW1 Detail 1 1:5A - 582 - Window SW1 Detail 2 1:5A - 595 - Schedules - WindowsA - 596 - Schedules - Opening Sun Control DevicesArchitectural - Details - PV MountingA - 711 - PV Façade Elements -A - 712 - Mounting Cramp 1:1A - 713 - Gusset Plate 1:2A - 714 - PV-Module 1:5A - 715 - Acrylic Glass 1:5A - 716 - Substructure - Components 1:10A - 721 - Surface 1:100A - 731 - Detail Façade - Roof 1:2A - 741 - Detail Connection Façade - Window 1:2A - 751 - Detail Façade - Deck 1:2A - 761 - Detail Corner - Substructure 1:5A - 771 - PV Wiring Type 1A - 772 - PV Wiring Type 2A - 781 - Schedules FaçadeArchitectural - Details - RoofA - 810 - Key plan roof 1:50A - 811 - Roof System - generalA - 831 - Sections Roof 1:20A - 841 - Top View PV Modules 1:50A - 842 - Top View PV Mounting System 1:50A - 843 - Top View Drainage 1:50A - 844 - Top View PV cable conduit 1:50A - 851 - Detail roof system 1:2A - 852 - Detail PV Mounting System Module Stoat 1:1A - 853 - Detail PV fascia north-south 1:2A - 854 - Detail drainage fascia north-south 1:2A - 855 - Detail fascia east-west 1:2A - 856 - Detail fall protection 1:5A - 857 - Detail PV Mounting System section 1:1A - 860 - Schedule - Roof 1A - 861 - Schedule - Roof 2Architectural - Details - SidingA - 911 - Key Plan Elevations 1:75A - 951 - Siding Detail Ceiling Floor 1:5A - 952 - Siding Detail Cut 1:5A - 953 - Siding Detail 1:5A - 954 – Schedules Siding Seite: 16/127
  • 17. Interiors - Living Space- GeneralI - 200 - Body - Furniture Interior renderingI - 201 - Body - Furniture AreasTable of ContentsI - 202 - Body - Furniture Structure SchemeI - 203 - Body - Furniture Cabinet Body MaterialsInteriors - Living Space- PlansI-210 - Body-Furniture Floor Plan 1st Floor 1:50I-211 - Body-Furniture Floor Plan 2nd Floor 1:50Interiors - Living Space- SectionsI-220 - Body -Furniture Longitudinal Section South 1:50I-221 - Body -Furniture Longitudinal Section North 1:50I-222 - Detail Longitudinal Section North Storage 1:20I-223 - Detail Elevation Longitudinal Section South Stairs 1:20I-230 - Detail Body-Furniture Cross-Section Stairs 1:20Interiors - Living Space- ElevationsI - 240 - Body -Furniture Elevations 1:50I - 241 - Detail Elevation South Stairs 1:20I - 242 - Detail Elevation North Storage 1:20Interiors - Living Space- StairsI - 270 - Stairs Stairs 1:50I - 271 - Scheme Stairs Sections 1:20I - 272 - Overview Handrail 2nd Floor 1:20I - 273 - Overview Handrail Stairs 1:20I - 274 - Steelprofile Steelstring Stairs 1:20I - 275 - Steelprofile Handrail 2nd Floor North 1:5I - 276 - Steelprofile Handrail 2nd Floor South 1:10I - 277 - Steelprofile Handrail Stairs 1:10I - 278 - Detail Steelprofile Handrail 2nd Floor and Stairs 1:2Interiors - Living Space- SchedulesI - 280 - Schedules – Body FurnitureI - 281 - Schedules – Body FurnitureI - 282 - Schedules – Body FurnitureInteriors - KitchenI - 321 - Horizontal Section I 1:10I - 322 - Horizontal Section II 1:10I - 323 - Horizontal Section III 1:10I - 331 - Vertical Section I 1:10I - 332 - Vertical Section II 1:10I - 341 - Elevation North 1:10I - 342 - Elevation South 1:10I - 351 - Technical Appliances I 1:10I - 352 - Technical Appliances II 1:10I - 353 - Schedules - Kitchen Seite: 17/127
  • 18. Interiors - BedroomI - 411 - Concept BedroomI - 412 - Manual BedI - 421 - Floor Plan Bed 1:20I - 431 - Longitudinal Section Bed 1:20I - 432 - Across Section Bed 1:20I - 451 - Construction Detail Bed 1:5I - 452 - Ropes for Opening 1:5Interiors - BathroomI - 510 - ConceptI - 521 - Floor Plan 1:20I - 531 - Elevation North 1:20I - 532 - Elevation East 1:20I - 533 - Elevation South 1:20I - 534 - Elevation West 1:20I - 541 - Longitudinal Section 1:20I - 551 - Detail Shower Tray 1:10I - 561 - Schedules - BathroomInteriors - FlooringI - 621 - Floor Plan level 0.5 1:50I - 622 - Floor Plan level 1.5 1:50I - 623 - Flooring Cable Conduit 1:50I - 651 - Detail Cable Conduit 1:5I - 652 - Detail Connection Wall / Window – Cable Conduit 1:5I - 653 - Detail Connection Wall Level 0.0 + 1.5 1:5I - 654 - Section - Stairs 1:5I - 655 - Section - Ramp 1:5I - 656 - Section Horizontale Module Cut Level 0.0 1:5I - 657 - Section Horizontale Module Cut Level 0.5 1:5I - 660 - Schedules - FlooringInteriors - RenderingsI - 701 - RenderingI - 702 - RenderingI - 703 - RenderingFire - ProtectionF - 111 - Symbols and NotesF - 211 - Detection and AlarmF - 311 - SuppressionF - 411 - EgressPlumbingP - 111 - Symbols and notesP - 211 - Supply and RemovalP - 311 - Schematic DiagramP - 411 - Water SupplyP - 421 - Water Supply 1:50P - 431 - Water Supply 1:50P - 511 - Waste Water DisposalP - 521 - Waste Water Disposal 1:50 Seite: 18/127
  • 19. P - 531 - Waste Water Disposal 1:50P - 541 - Waste Water Disposal 1:10P - 551 - Waste Water Disposal 1:10P - 611 - Schedules - PlumbingP - 612 - Schedules - PlumbingMechanical - Energy ConceptM - 101 - SystemsM - 102 - Flow Of EnergyM - 103 - PCM SystemM - 104 - Heat PumpM - 105 - Energy ThemesM - 106 - Scheme Summer DayM - 107 - Scheme Summer NightM - 108 - Scheme Winter DayM - 109 - Scheme Winter NightM - 110 - Scheme Spring DayM - 111 - Scheme Spring NightM - 112 - Planning ToolsM - 113 - Energy BalanceMechanical - DrawingsM - 211 - Heat Pump System Schematic DiagramM - 221 - Heat Pump System And Distribution Floorplan 1:50M - 222 - Heat Pump System And Distribution Floorplan 1:50M - 231 - Heat Pump System And Distribution Section 1:50M - 271 - Heat Pump System And Distribution Isometric 1:50M - 321 - Cooling Ceiling Section 1:50M - 331 - Cooling Ceiling Section 1:50M - 332 - Cooling Ceiling Section 1:20M - 351 - Cooling Ceiling Detail 1:20Mechanical - SchedulesM - 411 - Schedules - MechanicalM - 412 - Schedules - MechanicalElectricE - 001 - Electrical Appliances And InstallationsE - 002 - Building Automation - Utilization ConceptE - 121 - Electrical Appliances And Installations 1:50E - 131 - Electrical Appliances And Installations 1:50E - 132 - Electrical Appliances And Installations 1:50E - 133 - Electrical Appliances And Installations 1:50E - 141 - Placing Of Contest Sensors 1:50E - 151 - Schedules - Electrical AppliancesElectric - Artificial LightE-211 - Artificial Lighting Concept 1:100E-212 - Functional Lighting Plan Upper Level 1:50E-213 - Functional Lighting Plan Lower Level 1:50E-214 - Functional Lighting - Sections 1:50E-215 - Functional Lighting Integration LED stripE-216 - Lighting Renderings Seite: 19/127
  • 20. E-217 - Accent Lighting Concept 1:50E-218 - Accent Lighting Concept -E-219 - Atmospheric Lighting Concept 1:50E-220 - Multifunctional Body Illumination 1:1E-221 - Light Switch Concept 1:50E-222 - Lighting SchedulesElectric- Electrical Cabinet OutsideE - 301 - Electrical Cabinet Outside 1E - 302 - Electrical Cabinet Outside 1E - 303 - Electrical Cabinet Outside 2E - 304 - Electrical Cabinet Outside 2E - 305 - Electrical Cabinet Outside 2E - 306 - Electrical Cabinet PV Inverter JointE - 307 - Electrical Cabinet PV Inverter JointE - 308 - Electrical Cabinet PV Inverter JointElectric - PV InterconnectionE - 309 - PV Interconnection OverviewE - 310 - PV Interconnection OverviewE - 311 - PV Interconnection OverviewE - 312 - Design Of PV RoofE - 314 - PV Interconnection Overview FaçadeE - 315 - PV Interconnection Overview FaçadeE - 316 - PV Interconnection Overview FaçadeE - 317 - PV Interconnection Overview FaçadeE - 318 - PV Interconnection Overview FaçadeE - 319 - PV Interconnection Overview FaçadeE - 320 - PV Interconnection Overview FaçadeE - 321 - PV Interconnection Overview FaçadeE - 322 - PV Interconnection Overview FaçadeE - 323 - PV Interconnection Overview FaçadeE - 324 - PV Interconnection Overview FaçadeE - 325 - PV Interconnection Overview FaçadeE - 326 - PV Interconnection Overview FaçadeE - 327 - PV Interconnection Overview FaçadeE - 328 - Design Of PV FaçadeE - 329 - Design Of PV FaçadeE - 330 - Design Of PV FaçadeElectric - Electrical Cabinet InsideE - 401 - Electrical Cabinet InsideE - 402 - Electrical Cabinet InsideE - 403 - Electrical Cabinet InsideE - 404 - Electrical Cabinet InsideE - 405 - Electrical Cabinet InsideE - 406 - Electrical Cabinet InsideE - 407 - Electrical Cabinet InsideE - 408 - Electrical Cabinet InsideE - 409 - Electrical Cabinet InsideE - 410 - Electrical Cabinet InsideE - 411 - Electrical Cabinet InsideE - 412 - Electrical Cabinet Inside Seite: 20/127
  • 21. E - 413 - Electrical Cabinet InsideE - 414 - Electrical Cabinet InsideE - 415 - Electrical Cabinet InsideE - 416 - Electrical Cabinet InsideE - 417 - Electrical Cabinet InsideE - 418 - Electrical Cabinet InsideE - 419 - Electrical Cabinet InsideE - 420 - Room Control UnitE - 421 - Room Control UnitE - 422 - Design And Overcurrent ProtectionElectric - Load ListE - 501 - Load ListE - 502 - Load ListE - 503 - Load ListE - 504 - Load ListE - 505 - KNX Busline InsideE - 506 - Cross Section And Wiring OverviewE - 507 - Home Automation OverviewE - 508 - Schedule - LoadE - 509 - Schedule - LoadOther DisciplinesX - 111 - Site Accessibility 1:100X - 211 - Public Exhibit Plan 1:50X - 212 - Public Exhibit Deck 1:100X - 213 - Public Exhibit Mock Ups 1:100X - 311 - Schedule - Public TourOperationsO - 110 - Transport Germany-WashingtonO - 120 - Truck LayoutO - 130 - Transport DetailsO - 140 - Modules LayoutO - 210 - Site Operations Day 1O - 220 - Site Operations Day 1 and 2 –O - 310 - Site Operations Day 1-7 and DisassemblyO - 500 - Schedules - Operations EquipmentRessourcesR-101 - Client Site ElevationsR-102 - Client Site PlanR-103 - Client Site Photographs Seite: 21/127
  • 22. 00 01 20 List of SchedulesL - 711 Schedules - LandscapeL - 712 Schedules - LandscapeL - 713 Schedules - LandscapeL - 714 Schedules - LandscapeS - 461 - Schedules - VIPS - 677 - Schedule - TransportS - 678 - Schedule - TransportS - 679 - Schedule - TransportS - 715 - Schedules - Temporary ConstructionA - 595 - Schedules - WindowsA - 596 - Schedules - Opening Sun Control DevicesA - 781 - Schedules FaçadeA - 860 - Schedules RoofA - 861 - Schedules RoofA - 954 - Schedules SidingI - 280 - Schedules – Body FurnitureI - 281 - Schedules – Body FurnitureI - 282 - Schedules – Body FurnitureI - 353 - Schedules – Residential Kitchen AppliancesI - 561 - Schedules Bathroom PlumbingI - 660 - Schedules FlooringP - 611 - Schedules - PlumbingP - 612 - Schedules - PlumbingM - 411 - Schedule HVAC Heat PumpM - 412 - Schedule HVAC PCM CeilingE-151 - Schedules for Electrical Appliances and InstallationsE-222 - Lighting SchedulesE-508 - Schedule for Electrical DiagramsE-509 - Schedule for Electrical DiagramsX -311 - Schedule - Public TourO - 500 - Schedules - Operations Equipment Seite: 22/127
  • 23. 01 General Requirements01 53 00 Temporary Construction Part 1 GENERAL 1.1 SECTION INCLUDES A. Transport Bracing B. Transport Braces C. Threaded Rods 1.2 SUBMITTALS A. Product Datasheet (CD: Plan# S-661) B./C. No datasheets available; special design according to Construction Drawings S-661, S-664 – S-6616 Part 2 PRODUCTS 2.1 MANUFACTURER A. ROBUSTA-GAUKEL GMBH & CO. KG Brunnenstraße 36 D-71263 Weil der Stadt (Hausen) Phone: +49 (0)7033 5371-0 Fax +49 (0)7033 5371-31 E-Mail: info@robusta-gaukel.de Web: www.robusta-gaukel.de B./C. Internationaler Bund Darmstadt BaE Kooperative Ausbildung Metall / Elektro / Installation Advisor: Mr. Dilling Alsfelder Straße 3 64289 Darmstadt Deutschland Phone +49-6151-97154-14 Fax +49-6151-97154-29 Seite: 23/127
  • 24. 2.2 PRODUCTS A. Push-pull-props Type M Article No. 610130 and 610343 B. Transport Bracing – no article number C. Threaded rods – no article number Seite: 24/127
  • 25. 01 54 00 Construction Aids Part 1 GENERAL 1.1 SECTION INCLUDES A. Steel tie-bar (traverse) B. Trucks C. Crane D. Lifting loops E. Distribution Basin F. Cable ropes G. Tightener 1.2. SUBMITTALS A. Special design from metalworkers according to Construction Drawings S-711 – S-714 B. Special design from metalworkers according to Construction Drawings O-110 – O-310 C. Special design from metalworkers according to Construction Drawings O-110 – O-310 D/E. Weblink Datasheet: www.jordahl-pfeifer.ro/documente/pfeifer/Lifting_Loops_11_2007.pdf (CD: Plan# S-662) F. Datasheet (CD: Plan# S-663) G. Datasheet (CD: Plan# S-663) Part 2 PRODUCTS 2.1 MANUFACTURER A. Internationaler Bund Darmstadt Metall/Elektro/Installation Advisor: Mr. Dilling Alsfelder Straße 3 D-64289 Darmstadt phone +49-6151-97154-14 Fax +49-6151-97154-29 Web: www.internationaler-bund.de Information in English: www.internationaler-bund.de/fileadmin/user_upload/ib_englisch.pdf B/C. --- Seite: 25/127
  • 26. D/E. PFEIFER Holding GmbH & Co. KG Dr.-Karl-Lenz-Straße 66 D-87700 Memmingen phone +49 (0) 8331 - 937 - 0 Fax +49 (0) 8331 - 937 - 294 Web: www.pfeifer.de E-Mail: presse@pfeifer.deF/G. Carl Stahl GmbH Postweg 41 73079 Süßen phone. +49 (07162) 4007-3000 Fax +49 (07162) 4007-8830 Web: www.carlstahl.de E-Mail: carlstahl@carlstahl.com2.2 PRODUCTSA.-C. no article numberD. Pfeifer lifting loop 05.050.523.E. Pfeifer distribution basins 05.056.421F. Carl Stahl 1621.21.00G. Carl Stahl 5711.00.30 Seite: 26/127
  • 27. 01 54 23 Temporary Scaffolding Part 1 GENERAL 1.1 SECTION INCLUDES A. Mobile Scaffolding 1.2 SUBMITTALS A. no datasheet available – see example: http://www.layher-fahrgeruest.de/layher-uni-leicht/layher- unileicht-fahrgeruest-3204-arbeitshoehe.html (CD: Plan# O-110-310) Part 2 PRODUCTS 2.1 MANUFACTURER A. Wilhelm Layher GmbH & Co. KG Ochsenbacher Straße 56 74363 Güglingen-Eibensbach, Deutschland phone: +49 (0) 7135 70-0 Fax: + 49 (0) 7135 70-265 E-Mail: info@layher.com Web: http://www.layher.de/ http://www.layherusa.com/ 2.2 PRODUCTS A. Layher UniLeicht Mobile Scaffolding 3204 Working; Height: max. 6.30m Seite: 27/127
  • 28. 01 65 00 Product Delivery Requirements Part 1 GENERAL 1.1 SECTION INCLUDES A. Packing 1.2 SUBMITTALS A. no datasheet available – see example: (CD: Plan# O-110-310) Part 2 PRODUCTS 2.1/2.2 MANUFACTURER/ PRODUCTS A. not yet decided02 Existing Conditions - no entries03 Concrete - no entries04 Masonry - no entries Seite: 28/127
  • 29. 05 Metals05 05 23 Metal Fastening Part 1 GENERAL 1.1 SECTION INCLUDES A. Mounting B. Screwing 1.2 SUBMITTALS A. Product Data: Datasheet, Manufacturing Advices (CD: Plan# A-712, A-716, A-741, A-853, A-857) B. Weblink to Product Datasheet: http://www.wuerth.de/de/medien/holz/assy/de/assy-sk.pdf (CD: Plan# A-716, A-853, A-857) Part 2 PRODUCTS 2.1 MANUFACTURER A. Heroal-Johann Henkenjohann GmbH Österwieher Straße 80 33415 Verl Phone: +49 (0)5246-507253 Fax: +49 (0)5246-507275 www.heroal.de B. Adolf Würth GmbH & Co. KG Reinhold-Würth-Str. 12 - 17 74653 KÜNZELSAU-GAISBACH DEUTSCHLAND phone: +49 7940 15-0 Fax +49 7940 15-1000 E-Mail: info@wuerth.com Web: www.wuerth.de 2.2 PRODUCTS A. 64031 Mounting Type C for horizontal Substructure 64015 Mounting cramp Type F, special design 64030 21 Mounting Clip Type M 64034 21 Mounting Clip Type A46 B. Wheel Head Screws Würth ASSY SK 200x8mm Art. No. 0184 608 200 Jacksrew Seite: 29/127
  • 30. 05 14 00 Structural Aluminum Framing Part 1 GENERAL 1.1 SECTION INCLUDES A. Substructure PV roof B. Substructure PV facade 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# A-853, A-857) B. Product Data: Datasheets (CD: Plan# A-716, A-731-734, A- 761) Part 2 PRODUCTS 2.1 MANUFACTURER Heroal-Johann Henkenjohann GmbH Österwieher Straße 80 D-33415 Verl Phone: +49 (0)5246-507253 Fax: +49 (0)5246-507275 www.heroal.de 2.2 PRODUCTS – non standard – purpose-built items A. 18023 21 aluminum sheath 80mm 18233 21 aluminum drawer profile B. 64007 aluminum sheath 60/40mm 64007 aluminum sheath welded corner --- Ridge clamp – custom-made Seite: 30/127
  • 31. 05 20 00 Metal Joists Part 1 GENERAL 1.1 SECTION INCLUDES A. 05 20 00 Metal Joists B. 05 21 00 Steel Joist Framing 1.2 SUBMITTALS A/B. Product Data: non standard articles without existing Datasheet– Special design from metalworkers according to Construction Documents S-205, S-401-S-404 Product Datasheet for standard products (CD: Plan# S-205, S-401-404) Part 2 PRODUCTS 2.1 MANUFACTURER A. Internationaler Bund Darmstadt Metall / Elektro / Installation Advisor: Mr. Dilling Alsfelder Straße 3 64289 Darmstadt Deutschland phone +49-6151-97154-14 Fax +49-6151-97154-29 Web: www.internationaler-bund.de Information in English: www.internationaler-bund.de/fileadmin/user_upload/ib_englisch.pdf B. Holzbau Gröber GmbH Biberacher Straße 19 D - 88436 Eberhardzell-Füramoos Phone: +49 7358/ 960-0 Fax: +49 7358/ 960-60 E-Mail: info@groeber.de Web: www.groeber.de SIMPSON STRONG-TIE® GmbH Riederhofstrasse 27 D-60314 Frankfurt Phone: +49 69/67737 89 - 0 Seite: 31/127
  • 32. Fax: +49 69/67737 89 - 69 Web: www.strongtie.eu E-Mail: info@simpsonstrongtie.de2.2 PRODUCTS A. Steel angles B. Steel plates Locksmith stuff C. HTT 16 Tie Simpson Strong-Tie Joist Hangers Simpson Strong-Tie Seite: 32/127
  • 33. 05 25 00 Aluminum Joist Framing Part 1 GENERAL 1.1 SECTION INCLUDES A. Substructure PV-façade 1.2 SUBMITTALS A. Product Data: non standard articles without existing Datasheet– Special design from HEROAL according to Construction Documents A-713, A-716 Part 2 PRODUCTS 2.1 MANUFACTURER A. Heroal-Johann Henkenjohann GmbH Österwieher Straße 80 33415 Verl Phone: +49 (0)5246-507253 Fax: +49 (0)5246-507275 Web: www.heroal.de 2.2 PRODUCTS A. 64082 End Cap for Aluminium Sheath 60/40mm Aluminium Cable Clip Blinding Seite: 33/127
  • 34. 06 Wood, Plastics, and Composites06 05 00 Common Work Results for Wood, Plastics andComposites Part 1 GENERAL 1.1 SECTION INCLUDES A. 06 05 00 Common Work Results for W, P, and C B. 06 05 23 Wood, Plastics, and Composites Fastenings 1.2 SUBMITTALS A. Product Datasheet (CD: Plan# I-203) B. Product Data: Datasheets (CD: Plan# I-203) (CD: Plan# S-205, S-401-404) (CD: Plan# I-652-657) Part 2 PRODUCTS 2.1 MANUFACTURER A. Häfele GmbH & Co KG Adolf-Häfele-Str. 1 72202 Nagold Germany Tel: +49 (0)74 52 / 95 - 0 Fax: +49 (0)74 52 / 95 - 2 00 E-Mail: info@haefele.de Web: www.hafele.com B. Adolf Würth GmbH & Co. KG Reinhold-Würth-Str. 12 - 17 74653 KÜNZELSAU-GAISBACH DEUTSCHLAND phone: +49 7940 15-0 Fax +49 7940 15-1000 E-Mail: info@wuerth.com Web: www.wuerth.de SFS unimarket AG Nefenstrasse 30 CH-9435 Heerbrugg E-Mail: info.u@sfsunimarket.biz Web: www.sfsunimarket.biz Seite: 34/127
  • 35. 2.2 PRODUCTS A. Häfele Article No. 637.19.228 B. Wood Screws Würth ASSY ®3.0 SFS Screws intec see Datasheet Cocking pieces, bolts Seite: 35/127
  • 36. 06 11 00 Wood Framing 06 11 13 Engineered Wood Products Part 1 GENERAL 1.1 SECTION INCLUDES A. 06 11 13 Ceiling and flooring elements B. 06 11 13 Timber Construction beams C. 06 11 13 Bearing D. 06 11 13 Oak Profiles, feet 1.2 SUBMITTALS A. Product Datasheets (CD: Plan# S-205, S-401-S-404) B. Weblink to Product Data: http://www.rettenmeier.com/produkte/details/produkte/holzba u/kvh/1018.html (CD: Plan# S-205, S-401-S-404) C/D. no datasheet available – custom-made profiles made by Team Germany and a professional carpenter according to Construction Documents S-205, S-401 – S-404 Part 2 PRODUCTS 2.1 MANUFACTURER A. Lignotrend Produktions GmbH Landstrasse 25 D-79809 Weilheim-Bannholz Phone: +49 (0)7755 9200-0 Fax: +49 (0)7755 9200-55 www.lignotrend.com B-D. Rettenmeier Holding AG Industriestraße 1 D-91634 Wilburgstetten Phone: +49 9853 338-0 Fax: +49 9853 338-100 www.rettenmeier.com/en/home.html 2.2 PRODUCTS A. Lignotrend LIGNO Rippe Q3 (Ceiling element with acoustic components for large spans) Lignotrend LIGNO Block Q 90 (Ceiling and Flooring element) B. Rettenmeier Konstruktionsvollholz KVH®-1plus® (NSI) C/D. Rettenmeier Oak Seite: 36/127
  • 37. 06 12 00 Structural Panels Part 1 GENERAL 1.1 SECTION INCLUDES A. Structural Panels for Framing B. Structural Panels for Flooring 1.2 SUBMITTALS A. Weblink to Product Information: http://www.fh-finnholz.de/kerto-q.html Weblink to Product certification: www.fh-finnholz.de/english/download.html (CD: Plan# I-210-240) B. Datasheet Elka (CD: Plan# I-621, I-652-655) Part 2 PRODUCTS 2.1 MANUFACTURER A. FH-Finnholz GmbH Industriestraße 27 49536 Lienen Phone: +49 5483 1624 Fax: +49 5483 1245 Email: info@fh-finnholz.de Web: www.fh-finnholz.de B. elka-Holzwerke Hochwaldstraße 44 D-54497 Morbach Phone : +49 (0) 6533 / 956 0 Fax : +49 (0) 6533 / 956 220 E-Mail : info@elka-holzwerke.de Web: www.elka-Holzwerke.eu 2.2 PRODUCTS A. Kerto Q B. Elka Honeycomp wooden board, Interlayer, 70mm Seite: 37/127
  • 38. 06 16 00 Sheathing Part 1 GENERAL 1.1 SECTION INCLUDES A. 06 16 00 Sheathing B. 06 16 36 Wood Panel Product Sheathing 1.2 SUBMITTALS A/B. Datasheet OSB 3 (CD: Plan# I-652-657) Part 2 PRODUCTS 2.1 MANUFACTURER A/B. Agepan Glunz AG Grecostraße 1 D-49716 Meppen Phone: +49 (59 31) 4 05-0 Fax: +49 (59 31) 4 05-2 99 E-Mail: info@glunz.de Web: www.agepan.de 2.2 PRODUCTS A. OSB 3 Seite: 38/127
  • 39. 06 17 33 Wood I-Joists Part 1 GENERAL 1.1 SECTION INCLUDES A. Timber construction for double floor 1.2 SUBMITTALS A. Datasheet Part 2 PRODUCTS 2.1 MANUFACTURER A. Finnforest Deutschland GmbH Louis-Krages-Str. 30 D-28237 Bremen Phone: +49 421 6911 - 0 Fax: +49 421 6911 - 100 E-Mail: germany@finnforest.com Web: www.finnforest.de 2.2 PRODUCTS A. Finnjoist FJI 58 Seite: 39/127
  • 40. 06 40 00 Architectural Woodwork Part 1 GENERAL 1.1 SECTION INCLUDES A. 06 41 00 Architectural Wood Casework B. 06 43 13 Wood Stairs 1.2 SUBMITTALS A. Datasheet MDF (CD: Plan# I-210-I-240) Certificate MDF B. Datasheet (CD: Plan# I-270, I-271, I-278) Part 2 PRODUCTS 2.1 MANUFACTURER A. Agepan Glunz AG Grecostraße 1 D-49716 Meppen Phone: +49 (59 31) 4 05-0 Fax: +49 (59 31) 4 05-2 99 E-Mail: info@glunz.de Web: www.agepan.de B. EGGER Holzwerkstoffe Brilon GmbH & Co. KG Im Kissen 19 D-59929 Brilon Phone: +49/29 61/770-0 Fax: +49/29 61/770-62 222 Email: info-bri@egger.com Web: www.egger.com 2.2 PRODUCTS A. MDF 19 mm Agepan MDF 16 mm Agepan MDF 3 mm Agepan B. egger eurolight Seite: 40/127
  • 41. 06 60 00 Plastic Fabrications Part 1 GENERAL 1.1 SECTION INCLUDES A. 06 63 00 Plastic Railing B. 06 64 00 Plastic Paneling 1.2 SUBMITTALS A. Product Datasheet Plastic Railing (CD: Plan# I-210-I-240) B. Product Datasheet (LED Lighting) Plexiglas Panels (interior core CD: Plan# I-210-I-240) Product Datasheet Plexiglas (façade CD: Plan# A-714, A- 721-724) Part 2 PRODUCTS 2.1 MANUFACTURER A/B. Evonik Röhm GmbH Kirschenallee 64293 Darmstadt Deutschland phone: +49 (0) 61 51 - 18-01 Fax: +49 (0) 61 51 - 18-02 2.2 PRODUCTS A. Plexiglas GS Evonik 0F00GT B. Interior Core Alternative 1: Evonik Plexiglas Crystal Ice WM500 DC Evonik Plexiglas Satinice WH10 DC Evonik Endlighten 0N002 XL Alternative 2: Evonik Plexiglas Crystal Ice WM500 DC Evonik Plexiglas Satinice WH10 DC Kobek Lightpanel Luxolution For façade-use Plexiglas XT 7mm Seite: 41/127
  • 42. 07 Thermal and Moisture Protection07 21 00 Thermal Insulation Part 1 GENERAL 1.1 SECTION INCLUDES A/B. 07 21 00 Thermal insulation C. 07 21 00 Declining Roof Insulation D. 07 21 23 19 Mineral board Insulation 1.2 SUBMITTALS A. Datasheet Cellulose insulation (CD: Plan# I-621, I-652-655 / A-951) B. Datasheet Adhesive (Product Information from Internet shop) (CD: Plan# S-411-S-416) C. Datasheet Roof Insulation and Certificate (CD: Plan# A-831, A-843, A-851) D. Datasheets Vacuum Insulations Panels (CD: Plan# S-411-S- 416) Part 2 PRODUCTS 2.1 MANUFACTURER A. Agepan Glunz AG Grecostraße 1 D-49716 Meppen Phone: +49 (59 31) 4 05-0 Fax: +49 (59 31) 4 05-2 99 E-Mail: info@glunz.de Web: www.agepan.de B. Heinrich Dostmann GmbH Robert Ritschel Industriestraße 13 61449 Steinbach Deutschland C. Paul Bauder GmbH & Co. KG Korntaler Landstraße 63 D-70499 Stuttgart Phone: +49 711/69070 Fax: +49 711/6907300 Seite: 42/127
  • 43. E-mail: Stuttgart@bauder.de Web: www.bauder.de D. VARIOTEC GmbH & Co. KG Weißmarterstraße 3-5 D-92318 Neumarkt phone.: +49 9181 6946-0 Fax: +49 9181 8825 E-Mail: info@variotec.de www.variotec.de2.2 PRODUCTS A. Agepan Cell B. NIBOFLOOR PK ELASTIC C. EPS Inclining Insulation EPS 040 DAA dm 100 kPa 20- 80mm D. Variotec Qasa – VIP Seite: 43/127
  • 44. 07 25 00 Weather Barriers Part 1 GENERAL 1.1 SECTION INCLUDES A. Vapor Barriers (CD: Plan# A-831, A-843, A-851) B. Water Barriers (CD: Plan# A-831, A-843, A-851) 1.2 SUBMITTALS A. Datasheet B. Datasheet Part 2 PRODUCTS 2.1 MANUFACTURER A/B. Paul Bauder GmbH & Co. KG Korntaler Landstraße 63 D-70499 Stuttgart Phone: +49 711/69070 Fax: +49 711/6907300 E-mail: Stuttgart@bauder.de Web: www.bauder.de 2.2 PRODUCTS A. Interlayer Polymer Bitumen TEC Sprint DUO B. Thermoplan Waterproofing FPO, incl. adhesive Seite: 44/127
  • 45. 07 26 00 Vapor Retarders Part 1 GENERAL 1.1 SECTION INCLUDES A. Vapor Retarder 1.2 SUBMITTALS A. Datasheet Vapor Retarder Doerken (CD: Plan# A-951; I-621, I-652-655) Part 2 PRODUCTS 2.1 MANUFACTURER A. Dörken GmbH & Co. KG Wetterstraße 58 D-58313 Herdecke Phone: +49 23 30/63-428 Fax: +49 23 30/63-355 Email: info@doerken.de Web: www.doerken.de 2.2 PRODUCTS A. DELTA®-REFLEX Seite: 45/127
  • 46. 07 55 00 Protected Membrane Roofing Part 1 GENERAL 1.1 SECTION INCLUDES A. Building Protection 1.2 SUBMITTALS A. Datasheets (CD: Plan# A-831, A-857) Part 2 PRODUCTS 2.1 MANUFACTURER A. Paul Bauder GmbH & Co. KG Korntaler Landstraße 63 D-70499 Stuttgart Phone: +49 711/69070 Fax: +49 711/6907300 E-mail: Stuttgart@bauder.de Web: www.bauder.de Frank Griebel Verkauf Bauder Werk Bochum Phone: +49 6071/36608 Fax: +49 6071/3444568 2.2 PRODUCTS A. Bauder FSM 1100 Article No.: 7450 0600 Seite: 46/127
  • 47. 07 62 00 Sheet Metal Flashing and Trim Part 1 GENERAL 1.1 SECTION INCLUDES A. shop-formed accessories and trim, joint-covers, copings 1.2 SUBMITTALS A. Product Data: non standard articles without existing Datasheet– Special design from Metalworker according to Construction Documents A-851-855 Part 2 PRODUCTS 2.1 MANUFACTURER A. Stein und Sohn GmbH Rüdesheimer Straße 5 D-65239 Hochheim Phone: +49 6146/2269 Fax: +49 6146/3316 E-mail: info@steinundsohn.de Web www.steinundsohn.de 2.2 PRODUCTS A. Ridge bracket Ridge covering Fascia bracket Façade completion sheets Seite: 47/127
  • 48. 07 71 23 Manufactured Gutters and Downspouts Part 1 GENERAL 1.1 SECTION INCLUDES A. 07 71 33 gutters and downspouts B. 07 72 00 roof accessories 1.2 SUBMITTALS A/B. Product Data: non standard articles without existing Datasheet– Special design from Metalworker according to Construction Documents A-854 Part 2 PRODUCTS 2.1 MANUFACTURER A/B. Huppers Udo Huppers GmbH Landwehr 130 D-46514 Schermbeck Telefon 0 28 53/91 46 10 Telefax 0 28 53/91 46 13 Email: huppers-dach@arcor.de 2.2 PRODUCTS A. Downspouts Gutters B. leaves catch tray Seite: 48/127
  • 49. 07 90 00 Joint Protection Part 1 GENERAL 1.1 SECTION INCLUDES A. Tapes for interior application B. Tapes for exterior application 1.2 SUBMITTALS A. Weblink to Product Datasheets: http://www2.siga.ch/product/e_rissan.htm http://www2.siga.ch/product/e_sicrall.htm B. Weblink to Product Datasheets http://www.ts-udio.biz/tsshop2/WGS/1239/PRD/J999895/Alu- bedampftes_PP-Klebeband.htm Part 2 PRODUCTS 2.1 MANUFACTURER A. SIGA Cover AG Rütmattstrasse 7 CH-6017 Ruswil Phone: + 41 (0) 41 496 62 62 Fax: + 41 (0) 41 496 62 63 Email: siga@siga.ch Web: www.siga.ch B. Trenkenchu & Stadler GbR Schwabenstraße 43 71101 Schönaich Phone: +49 7031/413371 Fax: +49 7031/413372 Email: mail@ts-audio.de Web: http://www.ts-audio.de 2.2 PRODUCTS A. Siga Rissan Siga Sicrall B. Aluminum Tape J999895 Seite: 49/127
  • 50. 08 Openings08 10 00 Doors and Frames Part 1 GENERAL 1.1 SECTION INCLUDES A. 08 14 00 Wood Doors B. 08 32 19 Wood-framed Glass doors (sliding and non-sliding) 1.2 SUBMITTALS A. Product Datasheets (CD: Plan# A-545/546) B. Product Datasheets (CD: Plan# A-510/511, A-540, A-545) Part 2 PRODUCTS 2.1 MANUFACTURER A/B. Ludwig Häußler GmbH Fenster- und Türenfabrik Draisstr. 48 Industriegebiet West D-67346 Speyer Phone: +49 (0) 6232 / 3144 – 0 Fax: +49 (0) 6232 / 3144 - 37 Email: info@haeussler-fenster.de Web: www.energate.com 2.2 PRODUCTS A. Entrance Door Oak B. Terrace Doors Oak-framed, 3-glass toughened safety glassAs Team Germany’s windows and doors are special designed andactually still in fabrication, the manufacturer is not able yet topublish accordant datasheets containing all values and correctspecifications. The system of our windows is similar to themanufacturer’s “Energate”-series. You can find information aboutthis series here:http://www.energate.com/index.php?id=79&L=1 Seite: 50/127
  • 51. 08 50 00 Windows Part 1 GENERAL 1.1 SECTION INCLUDES A. 08 50 00 Operating Hardware 08 50 00 Louver blinds integral to window construction B. 08 52 00 Wood Windows 1.2 SUBMITTALS A. Weblink to Window Opener: http://www.hautau.pl/produkte/pdf/Prospekte_PDF/Oberlicht/ primat/primat_fl190_prospekt_d.pdf (CD: Plan# A-520/522) Product Datasheet motors (CD: Plan# A-520-523, A-536, A-540-546, A-550-552, A-580-582) Weblink to Motor Controller Datasheet: http://www.vestamatic.com/155/?L=1 (CD: Plan# A-520-523, A-540-542, A-546, A-580-582) Product Datasheets louver blinds (CD: Plan# A-520-523, A- 540-542, A-546, A-580-582) B. Datasheets (CD: Plan# A-510/511, A-540, A-550) Part 2 PRODUCTS 2.1 MANUFACTURER A. HAUTAU GmbH Bahnhofstr. 56-60 D 31691 Helpsen Phone: +49 (0) 5724 / 393-0 Fax: +49 (0) 5724 / 393-125 E-Mail: info@HAUTAU.de Web: www.hautau.de Maxon motor GmbH Truderinger Str. 210 D-81825 München phone: +49 89/420493- 0 Fax: +49 89/420493 - 40 E-Mail: info@maxonmotor.de Web: www.maxonmotor.de Seite: 51/127
  • 52. Vestamatic GmbH Dohrweg 27 D-41066 Mönchengladbach phone: +49 2161/29408-0 Fax: +49 2161/29408-20 www.vestamatic.com info@vestamatic.com Glas Hahn GmbH Kruppstrasse 6 D-67454 Haßloch / Pf. Phone: +49 (0)6324/92 45-0 Fax: +49 (0)6324/92 45-18 E-Mail: info@glas-hahn.de Web: www.glas-hahn.de B. Ludwig Häußler GmbH Fenster- und Türenfabrik Draisstr. 48 Industriegebiet West D-67346 Speyer Phone: +49 (0) 6232 / 3144 – 0 Fax: +49 (0) 6232 / 3144 - 37 Email: info@haeussler-fenster.de Web: www.energate.com 2.2 PRODUCTS A. Hautau PRIMAT- FL 190 Motor: Amax22 + HallEnc + GP22A Motor: ASM 44 – SG 13 Controller: IF SMI KNX 24 VDC Louver blinds Ropaco Typ F B. Oak-framed Window, 3-glass toughened safety glassAs Team Germany’s windows and doors are special designed andactually still in fabrication, the manufacturer is not able yet topublish accordant datasheets containing all values and correctspecifications. The system of our windows is similar to themanufacturer’s “Energate”-series. You can find information aboutthis series here:http://www.energate.com/index.php?id=79&L=1 Seite: 52/127
  • 53. 08 70 00 Hardware Part 1 GENERAL 1.1 SECTION INCLUDES A. 08 71 00 Door Hardware 1.2 SUBMITTALS A. Product Datasheets (CD: Plan# I-210-240) Part 2 PRODUCTS 2.1 MANUFACTURER A. Häfele GmbH & Co KG Adolf-Häfele-Str. 1 72202 Nagold Germany Tel: +49 (0)74 52 / 95 - 0 Fax: +49 (0)74 52 / 95 - 2 00 E-Mail: info@haefele.de Web: www.hafele.com 2.2 PRODUCTS A. Concealed Hinges 329.07.xxx Spring Hinges 245.54.xxx Seite: 53/127
  • 54. 08 80 00 Glazing Part 1 GENERAL 1.1 SECTION INCLUDES A. 08 81 00 Glass Glazing 1.2 SUBMITTALS A. not yet available Part 2 PRODUCTS 2.1 MANUFACTURER A. Glas Hahn GmbH Kruppstrasse 6 D-67454 Haßloch / Pf. Phone: +49 (0)6324/92 45-0 Fax: +49 (0)6324/92 45-18 E-Mail: info@glas-hahn.de Web: www.glas-hahn.de 2.2 PRODUCTS A. 3-glass panes toughened safety glass Seite: 54/127
  • 55. 09 Finishes09 20 00 Plaster and Gypsum Board Part 1 GENERAL 1.1 SECTION INCLUDES A. 09 22 00 Support for Gypsum Board B. 09 23 00 Gypsum Plastering 1.2 SUBMITTALS A. Product Datasheets Plaster Profiles (CD: Plan# A-951) B. Product Datasheet Smartboard (CD: Plan# A-911) Part 2 PRODUCTS 2.1 MANUFACTURER A. PROTEKTORWERK Florenz Maisch GmbH & Co. KG Viktoriastraße 58 D-76571 Gaggenau Tel. (0 72 25) 977-0 Fax (0 72 25) 977-180 Email: info@protektor.com Web: www.protektor.com B. Knauf Gips KG Am Bahnhof 7 D-97346 Iphofen phone: +49 (9323) 31-0 Fax: +49 (9323) 31-277 E-Mail: zentrale@knauf.de Web: www.knauf.de 2.2 PRODUCTS A. Plaster Profile Profil-Nr. 1315 B. K764 Knauf PCM SmartboardTM 23/26 Seite: 55/127
  • 56. 09 60 00 Flooring Part 1 GENERAL 1.1 SECTION INCLUDES A. 09 60 00 Flooring B. 09 64 00 Wood Flooring 09 64 23 Wood Parquet Flooring C. 09 68 00 Carpeting 1.2 SUBMITTALS A. Weblink to Product Datasheet Parquet glue:http://www.wakol.com/de/verlegewerkstoffe/produktprogramm/kleben/parkett-und-kork/ms-260.html (CD: Plan# I-621, I-652-655) Expansion Joint Cork: no datasheet (rest pieces of cork mats) (CD: Plan# I-621, I-653) B. outside flooring: not definitely decided no datasheet/no manufacturer (CD: Plan# L-232) Inside flooring: Weblink to Product Information Wood Strip Flooring Parquet (CD: Plan# I-621-657)http://www.druesedau.de/html/parkett_default.php?id=9&art=3 C. Weblink to Product Datasheet Rug for Galery: (CD: Plan# I- 622)http://www.vorwerk-teppich.de/sc/vorwerk/technische_daten/de/08957.pdf Part 2 PRODUCTS 2.1 MANUFACTURER A. Wakol GmbH Bottenbacher Str. 30 D-66954 Pirmasens Phone: +49 (0) 63 31 80 01 0 Fax: +49 (0) 63 31 80 01 890 B. DRÜSEDAU - Parkett & Leistenfabrik GmbH & Co. KG. Bahnhof Densberg D-34632 Jesberg-Densberg Phone: +49 66 95 - 96 06 - 0 Fax: +49 66 95 - 96 06 - 22 E-Mail: Info@druesedau.de www.druesedau.de C. Vorwerk & Co. Teppichwerke GmbH & Co. KG Kuhlmannstraße 11 Seite: 56/127
  • 57. D-31785 Hameln Phone: +49 5151 103-0 Fax: +49 5151 103-3772.2 PRODUCTS A. Wakol MS 260 based on polymer B. Oak Terrace Decking Wood Strip Flooring Parquet Oak C. Vorwerk „elemento - Tundra“ Seite: 57/127
  • 58. 09 80 00 Acoustic Treatment Part 1 GENERAL 1.1 SECTION INCLUDES A. 09 81 00 Acoustic Insulation 1.2 SUBMITTALS A. Weblink to Product Data for Cork materials:http://www.kork-store.de/shop/product_info.php?products_id=94 (CD: Plan# I-621/622, I-652-655) Datasheet for Knauf insulation layer (CD: Plan# I-621, I-652-655) Weblink to WAKOL insulation mat (CD: Plan# I-621, I-652-655)http://www.wakol.com/fileadmin/upload/pdf/Technische_Informationen/Verlegewerkstoffe/deutsch/5903D.pdf Part 2 PRODUCTS 2.1 MANUFACTURER A. Kork-Store Potsdam Lindenstr. 60 D-14467 Potsdam Phone: +49 331 2706808 Fax: +49 331 2706383 E-mail : info@kork-store.de Web: www.kork-store.de Knauf Gips KG Am Bahnhof 7 D-97346 Iphofen phone: +49 (9323) 31-0 Fax: +49 (9323) 31-277 E-Mail: zentrale@knauf.de Web: www.knauf.de Wakol GmbH Bottenbacher Str. 30 D-66954 Pirmasens Phone: +49 (0) 63 31 80 01 0 Seite: 58/127
  • 59. Fax: +49 (0) 63 31 80 01 890 2.2 PRODUCTS A. Insulation Corkboard 10 mm Article no. 1210 Insulation Corkboard 5mm Article no. 1250 B. Knauf Brio 23 WF C. WAKOL EM 14009 90 00 Painting and Coating Part 1 GENERAL 1.1 SECTION INCLUDES A. 09 91 23 Interior Painting 1.2 SUBMITTALS A. --- Part 2 PRODUCTS 2.1 MANUFACTURER A. not yet decided 2.2 PRODUCTS A. not yet decided color: white Seite: 59/127
  • 60. 10 Specialties10 28 00 Toilet, Bath, and Laundry Accessories Part 1 GENERAL 1.1 SECTION INCLUDES A. 10 28 16.13 Residential Bath Accessories 1.2 SUBMITTALS A. --- Part 2 PRODUCTS 2.1 MANUFACTURER A. not yet decided 2.2 PRODUCTS A. Towel bars Toilet paper dispensers Etc. Seite: 60/127
  • 61. 10 70 00 Exterior Specialties Part 1 GENERAL 1.1 SECTION INCLUDES A. 10 71 13 Exterior Sun Control Devises 1.2 SUBMITTALS A. Weblink to Product Datasheet Substructure http://www.glashauskg.de/Glashaus-KG.pdf (CD: Plan# A-520/523, A-536, A-550-552) Part 2 PRODUCTS 2.1 MANUFACTURER A. Glashaus KG Feilitzschstraße 21 D- 80802 München Phone: +49 89/33 03 81 85 Fax: +49 89/33 03 81 86 Email: info@glashauskg.de Web: www.glashauskg.de/index.html 2.2 PRODUCTS A. System Brillona www.glashauskg.de/brillona.html Seite: 61/127
  • 62. 11 Equipment11 30 00 Residential Equipment Part 1 GENERAL 1.1 SECTION INCLUDES A. 11 31 13 Residential Kitchen Appliances B. 11 31 23 Residential Laundry Appliances 1.2 SUBMITTALS A. Datasheets for Kitchen Appliances (CD: Plan# I-331-I-351) B. Datasheets for Laundry Appliances (CD: Plan# I-331-I-351) Part 2 PRODUCTS 2.1 MANUFACTURER A/B. Miele & Cie. KG Carl-Miele-Straße 29 D-33332 Gütersloh Phone: +49 52 41/ 89 - 0 Fax: +49 52 41/ 89 - 20 90 E-Mail: info@miele.de Web: www.miele.de 2.2 PRODUCTS A. Refrigerator/Freezer Combination Miele KF 9757 ID Dishwasher Miele G 1562 SCVi Steamer Miele Dgc 5080 Induction Cooker Miele KM 5975 Coffee Machine Miele CVA 5060 Fume Extraction Hood Miele DA 3190 B. Cloth Washer Miele W 3985 WPS or Allwater W3841 Laundry Dryer T 3841 Seite: 62/127
  • 63. 12 Furnishings12 30 00 Casework Part 1 GENERAL 1.1 SECTION INCLUDES A. 12 36 19 Manufactured Wood Casework 1.2 SUBMITTALS A. Product Data: non standard articles without existing Datasheet– Special design from Team Germany according to Construction Documents I-331, I-332, I-322, I-351 Part 2 PRODUCTS 2.1/2.2 MANUFACTURER/PRODUCTS A. Kitchen counter top; self made by Team Germany with support from a professional carpenter Seite: 63/127
  • 64. 12 40 00 Furnishings and Accessories Part 1 GENERAL 1.1 SECTION INCLUDES A. 12 42 00 Table Accessories B. 12 43 13.13 Desk Lamps C. 12 43 13.19 Floor Lamps D. 12 44 00 Bath Furnishings E. 12 45 00 Bedroom Furnishings 1.2 SUBMITTALS A. Product Data: not yet decided B. Weblink to Datasheet for LED high power Desk lamp (CD: Plan# I-331-I-351)http://engine.artemide.com/article.aspx?button=0&language=de&productids=art0829010A&product_level=artoneline_pr_tavolo_led C. Datasheet for Floor Lamps (alternatives possible) (CD: Plan# I-331-I-351)http://pdf.archiexpo.com/pdf/occhio/produkt-book/53078-25186.html D. Product Data: not yet decided E. Product Data: not yet decided Part 2 PRODUCTS 2.1 MANUFACTURER A/D/E. not yet decided B. eventually: Artemide GmbH Deutschland Hans-Böckler-Straße 2 D-58730 Fröndenberg Phone: (+49) 02373/975-0 Fax: (+49) 02373/975-2-09 E-Mail: personal@artemide.de Web: www.artemide.de C. Occhio axelmeiselicht AML Licht + Design GmbH Wiener Platz 7 Rgb. D-81667 München Phone: +49-89-44 77 86 30 Fax: +49-89-44 77 86 39 Email: info@occhio.de Seite: 64/127
  • 65. Web: www.occhio.de2.2 PRODUCTS A/D/E. not yet decided B. eventually: Artemide One Line LED Tavolo C. probably: Occhio Sento lettura Seite: 65/127
  • 66. 12 50 00 Furniture Part 1 GENERAL 1.1 SECTION INCLUDES A. 12 58 00 Residential Furniture 1.2 SUBMITTALS A. Product Data: not yet decided Part 2 PRODUCTS 2.1/2.2 MANUFACTURER/PRODUCTS A. Couch – not yet decided Dining Tables and Chairs – not yet decided13 Special Construction Seite: 66/127
  • 67. 14 Conveying Equipment14 80 00 Scaffolding Part 1 GENERAL 1.1 SECTION INCLUDES A. 14 81 16 Carriage Scaffolding 1.2 SUBMITTALS A. Product Data: Datasheet (CD: Plan# L-501) Part 2 PRODUCTS 2.1 MANUFACTURER A. Wilhelm Layher GmbH & Co. KG Ochsenbacher Straße 56 D-74363 Güglingen-Eibensbach, phone: +49 (0) 7135 70-0 Fax: + 49 (0) 7135 70-265 E-Mail: info@layher.com Web: http://www.layher.de/ http://www.layherusa.com/ 2.2 PRODUCTS A. Layher Allround System21 Fire Suppression Seite: 67/127
  • 68. 22 Plumbing22 10 00 Plumbing Piping and Pumps Part 1 GENERAL 1.1 SECTION INCLUDES A. 22 11 16 Domestic Water Piping B. 22 11 23 Domestic Water Pumps C. 22 12 00 Facility Potable-Water Storage Tank 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# P-311-331, P-411-451) B. Product Data: Datasheets (CD: Plan# P-311/P-511) C. Weblink to Product Information: http://www.dlkunststofftechnik.com/html/produkte.php Cerificate Part 2 PRODUCTS 2.1 MANUFACTURER A. REHAU AG + Co Rheniumhaus D-95111 Rehau Phone: +49 92/ 83-77 0 E-Mail: info@rehau.com Web: www.rehau.de Abu-plast Kunststoffbetriebe GmbH Am Bahnhof 20 D-96472 Rödental Phone: +49 (0)9563/93-0 Fax +49 (0)9563/93-226 B. GRUNDFOS GMBH Schlüterstraße 33 D-40699 Erkrath Phone: +49 (0)211 92969 0 E-Mail: infoservice@grundfos.de Seite: 68/127
  • 69. Web: www.grundfos.de C. DL-Kunststofftechnik Dietmar Leyh Ackerstr. 36 D-59423 Unna Phone: +49 (23 03) 96 85 83 Fax: +49 (23 03) 87 19 22 E-Mail: info@dlkunststofftechnik.com Web: www.dlkunststofftechnik.com2.2 PRODUCTS A. Versital Pipe – Rautitan Flex 130490-050 Sliding sleeve Rautitan PX 160002-001 Clip element 138043-001 T-piece, Rautitan PX 160032-001 Fitting, Rautitan PX 160011-001 Bridge – Rautitan MX 137134-001 Bridge Angle – Rautitan MX 137134-001 Bridge – Rautitan MX 139571-002 Angle – Rautitan PX, 90° 160022-001 Installation Angle – Rautitan MX 138491-405 Disposal Pipe, Raupiano Plus 12104-004 Disposal Pipe, Raupiano Plus 12184-004 Arc 45° Raupiano Plus 121114-001 Arc 45° Raupiano Plus 121164-001 Single Branch, Raupiano Plus 121264-001 Maintenance Pipe, 121524-002 Abu Pipeventilair Article No. 760099 Abu Pipeventilair Article No. 760399 B. Water pressure Pump Grundfos Jet Pump JP 5 Article No. 130490-050 Pump Add-on Grundfos C. Wastewater Tank Freshwater Tank Irrigation Tank Seite: 69/127
  • 70. 22 40 00 Plumbing Fixtures Part 1 GENERAL 1.1 SECTION INCLUDES A. 22 40 00 Plumbing Fixtures B. 22 41 00 Residential Plumbing Fixtures C. 22 41 13 Residential Water Closets, Urinals and Bidets D. 22 41 16 Residential Lavatories and Sinks E. 22 41 23 Residential Shower Receptors and Basins 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# I-521, I-531, I-552) B. Product Data: Datasheets (CD: Plan# I-521, I-531, I-552) C. Product Data: Datasheets (CD: Plan# I-521, I-531, I-552) D. Product Data: bathroom sink: non standard articles without existing Datasheet– Special design from KleinDesign according to Construction Documents I-521 kitchen sink: new Dornbracht series – actually no datasheets available: some Information and http://www.sadorex.ch/de/productdetail---1--1002--1007-- 1257--1--100378--0--0--0--0--0--378--0--0.html E. Product Data: non standard articles without existing Datasheet– Special design from KleinDesign according to Construction Documents I-521 Part 2 PRODUCTS 2.1 MANUFACTURER A/C. DURAVIT Aktiengesellschaft Werderstraße 36 D-78132 Hornberg Phone: +49 7833/70-0 Fax: +49 7833/70-289 Email: info@duravit.de Web: www.duravit.de Geberit Vertriebs GmbH Theuerbachstraße 1 D-88630 Pfullendorf Phone: +49 75 52 934-01 Fax: +49 75 52 934-300 Seite: 70/127
  • 71. E-Mail: sales.de@geberit.com Web: www.geberit.com B. Aloys F. Dornbracht GmbH & Co. KG Köbbingser Mühle 6 D-58640 Iserlohn Phone: +49 (0)2371-433-0 Fax: +49 (0)2371-433-232 E-Mail: info@dornbracht.de Web : www.dornbracht.de D/E. Klaus Klein Gmbh Zum Kaiserbusch 18 D-48165 Münster Phone: +49 251 - 61 70 79 Fax: +49 251 - 62 57 15 E-mail: info@klausklein-gmbh.de Web : http://www.kleindesign-muenster.de/index.htm2.2 PRODUCTS A/C. Toilet Duravit 221709 Toilet Seat Duravit 6769 Installation Geberit 458.103.00.1 Push-button Geberit 115.770.xx.1 B. Shower Disposer Dornbracht 41400979 Shower Disposer Sprinkler Dornbracht 27809980 Flush-mounting thermostat Dornbracht 36416780 Flush-mounting device Dornbracht 36310980 Mixing Valve Dornbracht 3552897090 Guiderail Dornbracht 1231097090 Wall bracket Dornbracht 3508597090 Faucet Dornbracht 13800980 Flush-mounting device Dornbracht 3569097090 Mixing Valve Dornbracht 36320980 Kitchen sink Dornbracht Prep DF 1110 Faucet Dornbracht 32800680 D/E. Lavotory Shower Basin Seite: 71/127
  • 72. 23 HVAC23 30 00 HVAC Air Distribution Part 1 GENERAL 1.1 SECTION INCLUDES A. 23 30 00 HVAC Air Distribution B. 23 33 00 Air Duct Accessories C. 23 34 00 HVAC Fans D. 23 37 00 Air Outlets and Inlets 1.2 SUBMITTALS A-D. Product Data: Datasheets Part 2 PRODUCTS 2.1 MANUFACTURER A/D. Nilan Deutschland GmbH Schenkgasse 9 D - 96472 Rödental Phone: +49 9563 / 3075-0 Fax: +49 9563 / 3075-22 E-Mail: info@nilan.de Web: www.nilan.de B. ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone: +49 7938 81-0 Fax: +49 7938 81-110 E-Mail: info1@de.ebmpapst.com Web: www.ebmpapst.com Robert Geiger Technische Bauteile GmbH Weiler Weg 14 D-89335 Ichenhausen Phone: +49 (0)8223 9688-0 Fax: +49 (0)8223 3764 Seite: 72/127
  • 73. Ludwig Häußler GmbH Fenster- und Türenfabrik Draisstr. 48 Industriegebiet West D-67346 Speyer Phone: +49 (0) 6232 / 3144 – 0 Fax: +49 (0) 6232 / 3144 - 37 Email: info@haeussler-fenster.de Web: www.energate.com C. ebm Papst (see B)2.2 PRODUCTS A. Air Distribution pipe ø 75mm W 420001 Air Distribution pipe ø 160 mm Air Distribution pipe ø 200 mm Connection sleeve ø 75 mm W 441001 B. Lamella flap Robert Geiger JK-A-06 L Facade flaps Energate (custom made, no datasheet) C. EC radial fan ebm Papst D3G 133-BF03 -02 D. Supply Air exhaust Nilan W 409002 Supply Air distributor W 401110 Supply Air distributor W 401202 Discharged Air Distributor (custom made, no datasheet) Grid for supply air exhaust (custom made, no datasheet) Seite: 73/127
  • 74. 23 50 00 Central Heating Equipment Part 1 GENERAL 1.1 SECTION INCLUDES A. 23 56 00 Solar Energy Heating Equipment 1.2 SUBMITTALS A. Product Data: Datasheet Part 2 PRODUCTS 2.1 MANUFACTURER A. Nilan Deutschland GmbH Schenkgasse 9 D - 96472 Rödental Phone: +49 9563 / 3075-0 Fax: +49 9563 / 3075-22 E-Mail: info@nilan.de Web: www.nilan.de 2.2 PRODUCTS A. Nilan VP 18 (C) Seite: 74/127
  • 75. 23 70 00 Central HVAC Equipment Part 1 GENERAL 1.1 SECTION INCLUDES A. 23 71 13 Thermal Heat storage 1.2 SUBMITTALS A. Product Data: Datasheet Part 2 PRODUCTS 2.1 MANUFACTURER A. Dörken GmbH & Co. KG Wetterstraße 58 D-58313 Herdecke Phone: +49 23 30/63-428 Fax: +49 23 30/63-355 Email: info@doerken.de Web: www.doerken.de 2.2 PRODUCTS A. Delta Cool 23 in Polycarbonate Profiles24 --- Seite: 75/127
  • 76. 25 Integrated Automation25 30 00 Integrated Automation Instrumentation andTerminal Devices Part 1 GENERAL 1.1 SECTION INCLUDES A. 25 30 00 Integrated Automation Instrumentation and Terminal Devices B. 25 35 16 Integrated Automation Sensors and Transmitters C. 25 37 00 Integrated Automation Instrumentation and Terminal Devices for Communication Systems 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# E-121/122, E-133, E- 502, E-507) Web:www.crestron.com/products B. Product Data: not yet decided C. Product Data: Datasheets (CD: Plan# E-401-403, E-411-417, E-420/421, E-501/503)http://www.knx-gebaeudesysteme.de/sto_g/English/_HTML/rubric_list.htm Part 2 PRODUCTS 2.1 MANUFACTURER A. Crestron Germany GmbH Ringstr. 1 D-89081 Ulm-Lehr Phone: +49 731-96 281 0 Fax: +49 731-96 281 50 Email: info@crestron.de Web: www.crestron-home.de Busch-Jaeger Elektro GmbH Freisenbergstraße 2 D-58513 Lüdenscheid Phone: +49 23 51/ 9 56-0 Fax: +49 23 51/ 9 56-1694 Email: info.bje@de.abb.com Web: www.busch-jaeger.de Seite: 76/127
  • 77. Apple Sales International Hollyhill Industrial Estate Hollyhill, Cork; Republic of Ireland B. not yet decided C. ABB Joseph Hogan Affolternstrasse 44 CH-8050 Zurich Switzerland Phone: +41 43 317 7111 Fax: +41 43 317 44202.2 PRODUCTS A. Wall Mount Touch Panel Crestron TPS-6L Wireless Touch Panel Crestron TPS-6X Rack Mount Shelf Crestron RMK5U Back Box Crestron BBI-4000 Gateway Crestron CEN-HPRFGW Control System Crestron CP2E Gateway EIB-Bus System Crestron CG-EIB Gateway DALI Bus System Crestron CG-DALI CG-DALI powersupply CG-DALI PS1 Powersupply CNPWS-75 LCD-touchpanel-4000L I-Pod Docking Station Crestron CENI-IDOC-DS Control Cable CRESNET-NP Wall Mount Touch Panel BuschJäger Comfort Panel 8136- 0-001 I-Phone C. ABB FC/S 1.1 ABB IPS/S 2.1 ABB JA/S 4230 1M ABB JSB/S 1.1 ABB SA/S 8.16.5S ABB SV/S 30.320.5 ABB SV/S 30.640.5 ABB US/U 2.2 ABB US/U 4.2 ABB WES/A 1.1 ABB WZ/S 1.1 ABB RC/A 8.1 ABB SA/M 2.6.1 ABB SD/M 2.6.1 ABB JA/M 2.230.1 Seite: 77/127
  • 78. 26 Electrical26 05 00 Common Work Results for Electrical Part 1 GENERAL 1.1 SECTION INCLUDES A. 26 05 13 Medium-Voltage Cables B. 26 05 36 Cable Trays for Electrical Systems 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# E-301-E-421, E-501) B. Product Data: Datasheets (CD: Plan# I-623, I-651/652/656/657) Part 2 PRODUCTS 2.1 MANUFACTURER A. HELUKABEL GmbH Dieselstrasse 8-12 D - 71282 Hemmingen / Stuttgart Phone: + 49 (0) 7150 / 9209-0 Fax: + 49 (0) 7150 / 81 78 6 E-Mail: info@helukabel.de Web: www.helukabel.de B. Hager Tehalit Vertriebs GmbH & Co. KG Zum Gunterstal D-66440 Blieskastel Phone: +49 6842 945-0 Fax: +49 6842 945-7666 Email: info@hager.de Web: www.hager.de 2.2 PRODUCTS A. Helukabel NYM-J 3x1.5/3x2.5/5x2.5 (inflexible wire) Helukabel H07-BQ-F 3x1.5/3x2.5/5x2.5 (flexible wire) Helukabel J-Y (St)-Y 4x0.8 (KNX bus wire) B. Standard Cable Conduit Seite: 78/127
  • 79. 26 20 00 Low-Voltage Electrical Distribution Part 1 GENERAL 1.1 SECTION INCLUDES A. 26 24 00 Switchboard and Equipment B. 26 27 16 Electrical Cabinets and Enclosures C. 26 27 26 Wiring Devices 1.2 SUBMITTALS A. Product Datasheets (CD: Plan# E-301-307, E-401-410, E-418/419) B. Product Datasheets C. Product Data: Datasheets receptacles, switches (CD: Plan# E- 502, E-507) Part 2 PRODUCTS 2.1 MANUFACTURER A. ABB Joseph Hogan Affolternstrasse 44 CH-8050 Zurich Switzerland Phone: +41 43 317 7111 Fax: +41 43 317 4420 B. Rittal GmbH & Co. KG Auf dem Stützelberg D-35745 Herborn Phone: +49 2772 - 505 - 0 Fax: +49 2772 - 505 - 2319 E-Mail: info@rittal.de Web: www.rittal.de ABB Striebel & John C. Busch-Jaeger Elektro GmbH Freisenbergstraße 2 D-58513 Lüdenscheid Phone: +49 23 51/ 9 56-0 Fax: +49 23 51/ 9 56-1694 Seite: 79/127
  • 80. Email: info.bje@de.abb.com Web: www.busch-jaeger.de2.2 PRODUCTS A. ABB S 751-3-E35 ABB Limitor B TNS ABB ZS/S 1.1 ABB F 204 ABB S-800 PV ABB NEOZED ABB UD/S 2.300.3 ABB S 203-B 40 ABB DBB 13000 ABB F 271 A-B16/0,03 ABB F274 AB-20/0,03 ABB S 201-B 16 ABB S 201-B 20 ABB S 201-B 40 ABB S 203-B 20 B. Basis Rittal flexRack(i) WS –Wandschränke IP 5 5 3/2WS WS – Wandschränke IP 3/2FS C. Light Switch Busch future linear Shading Switch Busch KNX-sensor Isolated Ground Receptacle Seite: 80/127
  • 81. 26 30 00 Facility Electrical Power Generating and StoringEquipment Part 1 GENERAL 1.1 SECTION INCLUDES A. 26 31 00 Photovoltaic Collectors Roof Photovoltaic Collectors Façade B. 26 32 00 Packaged Generator Assemblies 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# E-309-311, E-314-319) B. Product Data: Datasheets (CD: Plan# O-110-O-310) Part 2 PRODUCTS 2.1 MANUFACTURER A. SunPower GmbH Wiesenstrasse 5 D- 60385 Frankfurt a.M. Phone: +49 (0) 69 9563471-0 Fax: +49 (0) 69 9563471 99 E-Mail: solarde@sunpowercorp.com Web: www.sunpowercorp.de Home Website: www.sunpowercorp.com Würth Solar GmbH & Co. KG Alfred-Leikam-Str. 25 D-74523 Schwäbisch Hall Phone: +49 (0) 7 91 946 00 – 0 Fax: +49 (0) 7 91 946 00 - 119 Email: wuerth-solar@we-online.de Web: www.wuerth-solar.de         B.   ENDRESS Elektrogerätebau GmbH Neckartenzlinger Straße 39 D-72658 Bempflingen Seite: 81/127
  • 82. Phone: +49 (0) 71 23 / 97 37 - 0 Fax +49 (0) 71 23 / 97 37 - 50 Email: info@endress-generators.de Web: www.endress-generators.de  2.2 PRODUCTS A. Sunpower 300 Solar Panel WHT-300-l Würth Solar WSG00xx B. Endress Synchron Generator ESE 4500 T Seite: 82/127
  • 83. 26 50 00 Lighting Part 1 GENERAL 1.1 SECTION INCLUDES A. 26 51 13 Interior Lighting Fixtures, Lamps and Ballasts B. 26 56 00 Exterior Lighting 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# E-211, E-212) B. Product Data: Datasheets (CD: Plan# L-233) Part 2 PRODUCTS 2.1 MANUFACTURER A. Occhio AML Licht + Design GmbH Wiener Platz 7 Rgb. D-81667 München Phone: +49-89-44 77 86 30 Fax: +49-89-44 77 86 39 Email: info@occhio.de Web: www.occhio.de A/B. LUMITRONIX® LED-Technik GmbH Haigerlocher Str. 42 D-72379 Hechingen Phone: +49 (0) 7471 / 96014 -0 Fax +49 (0) 7471 / 96014 -99 Email: mail@leds.de Web: www.leds.de 2.2 PRODUCTS A. Occhio System Pendulum lamp Occhio System Wall lamp High Power LED-light stripes Lumitronix High Power LED-light spots Lumitronix B. High Power LED-light spots Lumitronix Seite: 83/127
  • 84. 27 Communications27 40 00 Audio-Video Communications Part 1 GENERAL 1.1 SECTION INCLUDES A. 27 41 00 Audio-Video Systems 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# E-121, E-132/133, E-502, E-507) Part 2 PRODUCTS 2.1 MANUFACTURER A. Crestron Germany GmbH Ringstr. 1 D-89081 Ulm-Lehr Phone: +49 731-96 281 0 Fax: +49 731-96 281 50 Email: info@crestron.de Web : www.crestron-home.de Artison 774 Mays Blvd., Suite 10-183 Artison and Sonance Incline Village, Nevada 89451 Products are USA obtained through: Mediacraft AG Phone: 775-833-4344 Gaugrafenstraße 19-23 Fax: 775-833-0223 D-60489 Frankfurt Phone: +49 69/3008800 Fax: +49 69/30854888 Sonance Office 212 Avenida Fabricante San Clemente, CA 92672-7531 U.S.A. Phone: 1.800.582.7777 Email: tech@sonance.com Seite: 84/127
  • 85. Philips GmbH Lübeckertordamm 5 D-20099 Hamburg Phone: +49 (0)40 - 28 99 0 Fax:+49 (0)40 - 28 99 28 29 Email: unternehmenskommunikation@philips.com Web: www.philips.de Loewe AG Industriestraße 11 D- 96317 Kronach Phone: +49 (0)9261 / 99-0 Fax: + 49 (0)9261 / 99-500 Email: ccc@loewe.de Apple Sales International Hollyhill Industrial Estate Hollyhill, Cork Republic of Ireland2.2 PRODUCTS A. Media Soundcontrol Crestron AMSI Front Speaker Artison Portrait LCR Satellite Speaker Sonance VP 65S SUR Subwoofer Sonance SAW Blu-Ray Player Philips BDP5000 Television Loewe 68436U42 Apple I-POD Seite: 85/127
  • 86. 28 Electronic Safety and Security28 05 00 Common Work Results for Electronic Safety andSecurity Part 1 GENERAL 1.1 SECTION INCLUDES A. 28 05 13 Conduction and Cables for Electronic Safety and Security 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# A-781/782) Part 2 PRODUCTS 2.1 MANUFACTURER A. LAGRA ELEKTROTECHNIK GMBH Bahnhofstrasse 8 D-69245 Bammental Phone: +49 (0) 6223 - 47101 Fax: +49 (0) 6223 - 49152 Email: info@lagra.de Web: www.lagra.de 2.2 PRODUCTS A. Lagra VS-505.1-M Conduit fitting Lagra VS-505-PG Conduit fitting Lagra VS-506-GAS Conduit fitting Lagra Junction Box Series T Lagra Conduit 5/LA Lagra Connector Box Seite: 86/127
  • 87. 28 30 00 Electronic Detection and Alarm Part 1 GENERAL 1.1 SECTION INCLUDES A. 28 31 00 Fire Detection and Alarm 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# F-211) Part 2 PRODUCTS 2.1 MANUFACTURER A. ABB Joseph Hogan Affolternstrasse 44 CH-8050 Zurich Switzerland Phone: +41 43 317 7111 Fax: +41 43 317 4420 2.2 PRODUCTS A. Optical Smoke Detection ORM 2151 Seite: 87/127
  • 88. 29 ---30 ---31 Earthwork32 Exterior Improvement33 Utilities34 Transportation35 Waterway and Marine Construction36 ---37 ---38 ---39 ---40 Process Integration41 Material Processing and Handling Equipment Seite: 88/127
  • 89. 42 Process Heating, Cooling, and Drying Equipment42 31 16 Dessicant Equipment Part 1 GENERAL 1.1 SECTION INCLUDES A. Dehumidifier Humidifier 1.2 SUBMITTALS A. Product Data: Datasheets (CD: Plan# M-222) Part 2 PRODUCTS 2.1 MANUFACTURER A. ClimeTools Florian-Geyer-Weg 4a D-97204 Höchberg Phone: +49 931 4043743 Fax: +49 931 4043745 E-Mail: info@climetools.de Web: www.climetools.de 2.2 PRODUCTS A. Dehumidifier climetools CT-10+ Humidifier climetools CT-B450+43 Process Gas and Liquid Handling, Purification, andStorage Equipment44 Pollution Control Equipment45 Industry-Specific Manufacturing Equipment46 ---47 --- Seite: 89/127
  • 90. 48 Electrical Power Generation48 10 00 Electrical Power Generation Equipment Part 1 GENERAL 1.1 SECTION INCLUDES A. 48 19 16 Electrical Power Generation Inverters 1.2 SUBMITTALS A. Product Data: Datasheets for Inverters for roof-used PV (CD: Plan# E-309-311) Datasheets for Inverters for façade-used PV (CD: Plan# E-326/327) Part 2 PRODUCTS 2.1 MANUFACTURER A. SMA Solar Technology AG Sonnenallee 1 D-34266 Niestetal Phone: +49 561 95 22-0 Fax: +49 561 95 22-100 E-Mail: info@SMA.de Web: www.SMA.de Würth Solar GmbH & Co. KG Alfred-Leikam-Str. 25 D-74523 Schwäbisch Hall Phone: +49 (0) 7 91 946 00 – 0 Fax: +49 (0) 7 91 946 00 - 119 Email: wuerth-solar@we-online.de Web: www.wuerth-solar.de   2.2 PRODUCTS A. Sunny boy 1100/1700 Sunny Mini Central 5000A Würth Solar SolarMax IQ 1000/2000 WR10007 Seite: 90/127
  • 91. 4. Structural CalculationsStructural Calculations calculated and stamped by:Dipl.-Ing. Jochen Stahl, P.Eng.Department of Engineering and GeodesyPetersenstraße 1264287 DarmstadtPhone: +49 6151/167436Fax: +49 6151/162338stahl@iwmb.tu-darmstadt.deTragwerk+Frankfurter Straße 15WeiterstadtFor calculations follow this link to Appendix! Seite: 91/127
  • 92. 5. Detailed Water BudgetThe Water budget is integrated in the Construction Drawings – subsetPlumbing, Supply and Removal, Plan number: #P-2116. Summary of Unlisted Electrical ComponentsAccording to the different Standards in America and Germany, many of ourproducts will not have UL-Certification. Regarding the roof installation wewill use SunPower PV-modules SPR-300E-WHT-U with UL-certification:UL-Certificationhttp://us.sunpowercorp.com/downloads/product_pdfs/residential/SunPower_Safety_Installation_Manual_UL_certified_product_Letter_UL_0D_12.pdfIEC-Certificationhttp://us.sunpowercorp.com/downloads/product_pdfs/residential/SunPower_Safety_and_Installation_Instructions_IEC_A.pdfThe Inverters from SMA do not have UL-Certification. They meet severalstandards and regulations in Europe listed in the following graphic.SMA produces inverters for the U.S. market as well, which do have UL-certificationUL-Certification of a comparable product of SMAhttp://download.sma.de/smaprosa/dateien/4752/SUNNYBOY567-DUS091314W.pdfUnlisted electrical components are used in the building façade. As pointed outduring the Conference Call between Team Germany, John Wiles, Tom Meyersand Mike Wassmer, on Wednesday May, 27th and the following Emails we willdeliver all necessary verifications for the National Mall event to prove thesecurity for the visitors.Regarding the façade, we actually plan to use unlisted products for PV-modules and inverters. Further changes have to be done in coordination withJohn Wiles and Tom Meyers. The PV-module will be produced by WürthSolar. The standard size PV-module is certified in the IEC Standard. We willsend a copy to John Wiles and Tom Meyers if document is available for us.The inverters are produced by Solar-Max. Similar to the actually choseninverter, the products produced in Switzerland meet several standards andregulations in Europe listed in the following graphic. Seite: 92/127
  • 93. Seite: 93/127
  • 94. Seite: 94/127

×