• Like
Turbo tech presentation for ECT in kraft paper manufacturing plant
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

Turbo tech presentation for ECT in kraft paper manufacturing plant

  • 342 views
Published

 

Published in Engineering , Business , Technology
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
342
On SlideShare
0
From Embeds
0
Number of Embeds
5

Actions

Shares
Downloads
5
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide

Transcript

  • 1. 111 Presentation on ECT for Kraft Paper Manufacturing Plant (Case Study) TurboTech Precision Engineering (P) Ltd Nelamangala, Bangalore, INDIA
  • 2. 2222 At Process Plant of Union Paper Mill, Dubai  TurboTech Supplied and Commissioned 550 KW Turbine to Customer UPM, Dubai (First Recycled Paper Plant in UAE)  This Paper Plant is Located at Dubai, Al Quoz Industrial Area  Plant began operations in 1987. Primary raw material is waste paper and end products include Fluting, Test Liner and Core Board
  • 3. 3333 Mini Steam Turbine – As Offered for UPM,Dubai Paper Plant Type: Recycled Waste Paper Plant Paper Plant Capacity: 400 TPD Application: Steam Turbine installed parallel to PRV downstream of Process Boiler Type of Turbine: Back Pressure Voltage: 380 V Frequency: 50 Hz Design Inlet Pressure: 16 Bar (g) Design Inlet Temp: 204 Deg C (Saturated) Design Inlet Flow: 20 TPH Design Exit Pressure: 5 Bar (g) Turbine Power Output: 550 kW
  • 4. Photograph of Turbine – As Installed at UPM, Dubai
  • 5. Snapshot of Turbine Log Sheet – As Installed at UPM, Dubai
  • 6. Certificate of Appreciation from Customer UPM,Dubai
  • 7. Energy and Cost Savings through Turbine Installation at UPM,Dubai Energy Savings: Electricity Units Generated per Hour: 550 No of Days Plant Operating Per Year: 300 Electricity Units Generated Per Year: Approx 40 Lakh Units Cost Savings: Total Cost Savings from Year 2007 Till Date: 560 Lakh Rupees (5.6 Crore Rupees !!!)
  • 8. Mini Steam Turbines Support Fight Global Warming Apart from Supporting Energy and Cost Savings, Turbo Tech's Mini Steam Turbines Support in Fighting Global Warming as ELECTRIC POWER generated through the turbines in these type of applications are GREEN in nature with no burning of Fossil Fuel The Subject Turbine at Union Paper Mills has prevented about 28000 Tons of CO2 (Carbon Di Oxide – Green House Gas that causes Global Warming) release to the Atmosphere over these 7 Years of Operation, a significant contribution to a Green and Safe Environment at a Mini Level