biopsy valves &
irrigation accessories
BioShield® biopsy valves and irrigation accessories are
    single-use, offering unsurpassed protection for patients and staff.



Why single-use valves?
It is nearly impossible to manually clean, disinfect, flush and dry biopsy valves. Reused

biopsy valves can become leaky and potentially harbor dangerous pathogens - putting

both patients and healthcare workers at risk. Fortunately, BioShield® biopsy valves are

single-use, leaving you one less thing to worry about.


Why take the risk?
     Trust BioShield® biopsy valves.
BioShield® biopsy valve
economy
00711125/00711135
Olympus/Fujinon

00711136
Pentax

             It just makes sense
              Single-use valves reduce the
              possibility of cross-contamination
              between patients. Small valve size
              and easy device passage offer
              exceptional fuctionality during usage.

                                                       1136
                                                       Pentax




                              1125/1135
                               Olympus/Fujinon
Did you know?
Findings suggest biopsy valves aren’t designed to be cleaned and reprocessed…


FACT: The design of a biopsy valve                        FACT: Biopsy valves have internal
inhibits the reach and effectiveness of                   flaps that squeegee biomaterial off
cleaning brush bristles, making it nearly                 devices as they are extracted, allowing
impossible to remove debris from                          it to collect deep within the valve’s inner
inner crevices                                            crevices

        Arrows show insufficient
             contact of cleaning
            brush bristles within
               internal crevices




 Play it safe...US Endoscopy’s line of BioShield® biopsy valves are single-use
 so you no longer have to worry about what lingers in those hidden crevices


     what the experts are saying
     “...cleaning brush bristles must come in contact with all surfaces of the
                                                                                           1
     endoscope channel, parts, connectors and orifices before reuse is safe.”

     “Air pockets in the biopsy-port caps that prevented effective contact between disinfectants
     and the microorganisms when submerged during cleaning were pinpointed as the culprits of
     the spreading bacteria. Also, the design of the caps prevented thorough cleaning and drying of
     surfaces inside the caps, thus providing an environment where the bacteria could survive the
     usual disinfection procedures, according to doctors.” 2

     “Rubber biopsy port caps must be discarded after all procedures involving the
     passage of biopsy forceps, guidewires and/or other accessories through the
     endoscope.” 3

     “...healthcare-related infections from endoscopy continue to occur, in part, because
     endoscopes are difficult to clean due to their complex nature, which includes “springs
     and valves” as parts of the endoscope that complicate adequate disinfection.” 4
In a documented study,* published in EndoNurse and Infection Control Today,
  researchers found visible debris/proteinaceous material in over 50% of the
  test valves. The reprocessed valves used in the study, supplied from three major U.S.
  institutions, were deemed “clean and ready to use” prior to microscopic evaluation.

  The results showed wear and damage to valve structure, gross contamination
  on the outer edges, and contamination within the nooks and crannies of the valves -
  where cleaning brushes can’t always reach.      (Figure 1.2-1.4 taken from David M. Parente, BS, BA, MBA, “Could Biopsy Port Valves be a
                                                                                              Source for Potential Flexible Endoscope Contamination,” Infection Control Today, Volume 11, No. 6, (June 2007).




                                                                                                                                                                                                 Contamination


                                                                   Contamination in
                                                                      nooks and
                                                                   crannies of valve



Contamination along
  edge of opening




   Fig 1.2 - Valve observed during                                        Fig 1.3 - Internal cross section of valve                                 Fig 1.4 - Valve observed during
   microscopy demonstrates wear and                                       observed at magnification of approxi-                                     microscopy at 10x magnification.
   damage after use, manual cleaning                                      mately 10x demonstrates presence of                                       Note the presence of pinkish droplets
   and high-level disinfecting. Note the                                  contamination in nooks and crannies                                       on the edge of the valve opening,
   presence of contamination along                                        of valve.                                                                 representing gross contamination.
   edge of the opening.



                      related articles
                      •	Society of Gastroenterology Nurses and Associates, Inc., “Position Statement, Reprocessing of Endoscopic Accessories and Valves,”
                      	 Gastroenterology Nursing, Volume 25, No. 5, (September/October 2002).

                      •	WGO / OMED, “Practice Guideline: Endoscope Disinfection,” World Gastroenterology News, Volume 11, Issue 1, (Spring 2006).

                      •	K. M. Mohandas, “Mucocutaneous exposure to body fluids during digestive endoscopy: the need for universal precautions,” Indian
                      	 Society of Gastroenterology, Volume 19, (July-September 1999).



   Source 1: American Society for Gastrointestinal Endoscopy and the Society for Healthcare Epidemiology of America, “Multi-society guideline for reprocessing flexible gastrointestinal endoscopes,”
   Gastrointestinal Endoscopy, Volume 58, No. 1, (2003).
   Source 2: Jon Coomer, “Investigative team exposes equipment dangers,” New England Journal of Medicine, (2003).
   Source 3: Endoscopy Committee, British Society of Gastroenterology, “BSG Guidelines For Decontamination of Equipment for Gastrointestinal Endoscopy,” BSG Working Party Report, (February 2008).
   Source 4: Kelly M. Pyrek, “Nooks and Crannies: The Breeding Grounds for Bacteria,” Infection Control Today, (June 2002).
   Source*; David M. Parente, BS, BA, MBA, “Could Biopsy Port Valves be a Source for Potential Flexible Endoscope Contamination,” Infection Control Today, Volume 11, No. 6, (June 2007).
BioShield® irrigator

                                                                    Imagine being able to...
                                                                                         flush blood, exudate and other debris
                                                                                         out of your way at anytime throughout a
                                                                                         procedure*- even with a device in place
                1133
                                                                                         reduce frustration and wasted time spent
                                                                                         exchanging devices and syringes just to
                                                                                         cleanse your field of view


                                                                                             How important is a clear view?
                                                                                                  The BioShield® irrigator affords immediate,
                                                                                                  direct, intraprocedural irrigation. Simply
                                                                                                  attach a 60cc syringe to the irrigation line,
                                                                                                  or use extension tubing to connect with
     00711133                                                                                     your water pump for hands-free, foot pedal
     Olympus/Fujinon
                                                                                                  control.
     00711137
     Pentax (not pictured)



  Add a whole new level of efficiency
  to your endoscopy procedures
  with the BioShield® irrigator


                                                                                                                        immediate, direct irrigation
                                                                                                                        with device in channel


*In order to achieve moderate irrigation pressure and minimize leakage,
there must be sufficient room within the biopsy channel for fluid to pass when there is a device in place
product information
                            part number                description                                                                                            length           qty/box
                                                                                                                                                               (cm)

     Olympus & Fujinon (G5 series and newer) compatible


                            00711135                   BioShield® biopsy valve - economy                                                                          —               100
                            00711125                   BioShield® biopsy valve - economy                            (20 per pack/10 packages)                     —               200



                            00711133                   BioShield® irrigator                                                                                    30.5                50




                            00711138                   BioShield® biopsy valve ERCP                                                                               —                 25



     Pentax compatible



                            00711136                   BioShield® biopsy valve - economy                                                                          —                100




                            00711137                   BioShield® irrigator                                                                                    30.5                50




                                                                                                                                         adaptor             length           qty/box
      universal irrigation accessories
                                                                                                                                          gauge               (cm)


                            00711131                   universal irrigating adaptor                                                             15             2.54                50
                                                                                                                                                            (adaptor)



                            00711134                   universal water pump extension tubing                                                    —               180                50




Listening…and delivering solutions®, the US Endoscopy listening…and delivering solutions design, and all marks denoted with ® or ™ are registered with
the U.S. Patent and Trademark Office, or trademarks owned by US Endoscopy
BioShield® biopsy valves are intended to be used with gastrointestinal endoscopes.
Fujinon® is a registered trademark of Fuji Film Co., Ltd. Olympus® is a registered trademark of Olympus Optical, Inc. PENTAX® is a registered trademark of Asahi Kogaku Kogyo Kabushiki Kaisha.
5976 Heisley Road
		                    Mentor, OH 44060
	           phone    (1) 440 / 639-4494
	              fax   (1) 440 / 639-4495
	 customer service    (1) 800 / 769-8226

                                           760235 Rev. D

More Related Content

What's hot

Recent advances in irrigation systems
Recent advances in irrigation systemsRecent advances in irrigation systems
Recent advances in irrigation systemsHemant Mahala
 
Root Canal Irrigants or Endodontic irrigants
Root Canal Irrigants or Endodontic irrigants Root Canal Irrigants or Endodontic irrigants
Root Canal Irrigants or Endodontic irrigants surabhisoumya1
 
Penetrant Testing PPT
Penetrant Testing PPTPenetrant Testing PPT
Penetrant Testing PPTSolamanJose
 
Introduction to Liquid Penetrant Testing
Introduction to Liquid Penetrant TestingIntroduction to Liquid Penetrant Testing
Introduction to Liquid Penetrant TestingHareesh K
 
Intro to penetrant
Intro to penetrantIntro to penetrant
Intro to penetrantRajiv Singh
 
Endodontic irrigants pres
Endodontic irrigants presEndodontic irrigants pres
Endodontic irrigants presDrhind 88
 
Materials for disinfecting the pulp space
Materials for disinfecting the pulp spaceMaterials for disinfecting the pulp space
Materials for disinfecting the pulp spaceParth Thakkar
 
Irrigation and inracanal medicaments
Irrigation and inracanal medicaments Irrigation and inracanal medicaments
Irrigation and inracanal medicaments Hamza Tahir
 
Endodontic sealers and irrigating solutions /prosthodontic courses
Endodontic sealers and irrigating solutions /prosthodontic coursesEndodontic sealers and irrigating solutions /prosthodontic courses
Endodontic sealers and irrigating solutions /prosthodontic coursesIndian dental academy
 
Root Canal Irrigation During Endodontic Treatment
Root Canal Irrigation During Endodontic TreatmentRoot Canal Irrigation During Endodontic Treatment
Root Canal Irrigation During Endodontic TreatmentIraqi Dental Academy
 
Current concept of endodontic irrigation
Current concept of endodontic irrigationCurrent concept of endodontic irrigation
Current concept of endodontic irrigationDenny Rinto Alam DDS
 
Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...
Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...
Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...MAHESH PANDIT
 
Root canal irrigants
Root canal irrigantsRoot canal irrigants
Root canal irrigantsSaeed Bajafar
 
Sodium hypochlorite
Sodium hypochloriteSodium hypochlorite
Sodium hypochloriteAnoop Nair
 
Point-of-Use Glassware Washers Presentation
Point-of-Use Glassware Washers PresentationPoint-of-Use Glassware Washers Presentation
Point-of-Use Glassware Washers PresentationLabconco Corporation
 
Irrigation in endo ppt
 Irrigation in endo ppt Irrigation in endo ppt
Irrigation in endo pptDaniel Baiyee
 

What's hot (20)

Recent advances in irrigation systems
Recent advances in irrigation systemsRecent advances in irrigation systems
Recent advances in irrigation systems
 
Root Canal Irrigants or Endodontic irrigants
Root Canal Irrigants or Endodontic irrigants Root Canal Irrigants or Endodontic irrigants
Root Canal Irrigants or Endodontic irrigants
 
Penetrant Testing PPT
Penetrant Testing PPTPenetrant Testing PPT
Penetrant Testing PPT
 
Introduction to Liquid Penetrant Testing
Introduction to Liquid Penetrant TestingIntroduction to Liquid Penetrant Testing
Introduction to Liquid Penetrant Testing
 
Irrigants in endodontics
Irrigants in endodontics Irrigants in endodontics
Irrigants in endodontics
 
Intro to penetrant
Intro to penetrantIntro to penetrant
Intro to penetrant
 
Irrigation techniques
Irrigation techniques Irrigation techniques
Irrigation techniques
 
Penetrant testing
Penetrant testingPenetrant testing
Penetrant testing
 
Endodontic irrigants pres
Endodontic irrigants presEndodontic irrigants pres
Endodontic irrigants pres
 
Materials for disinfecting the pulp space
Materials for disinfecting the pulp spaceMaterials for disinfecting the pulp space
Materials for disinfecting the pulp space
 
Irrigation and inracanal medicaments
Irrigation and inracanal medicaments Irrigation and inracanal medicaments
Irrigation and inracanal medicaments
 
Endodontic sealers and irrigating solutions /prosthodontic courses
Endodontic sealers and irrigating solutions /prosthodontic coursesEndodontic sealers and irrigating solutions /prosthodontic courses
Endodontic sealers and irrigating solutions /prosthodontic courses
 
Root Canal Irrigation During Endodontic Treatment
Root Canal Irrigation During Endodontic TreatmentRoot Canal Irrigation During Endodontic Treatment
Root Canal Irrigation During Endodontic Treatment
 
Current concept of endodontic irrigation
Current concept of endodontic irrigationCurrent concept of endodontic irrigation
Current concept of endodontic irrigation
 
Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...
Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...
Liquid Penetrant Testing L-III presentation prepared by MAHESH PANDIT,OMNDT,J...
 
Root canal irrigants
Root canal irrigantsRoot canal irrigants
Root canal irrigants
 
Sodium hypochlorite
Sodium hypochloriteSodium hypochlorite
Sodium hypochlorite
 
Point-of-Use Glassware Washers Presentation
Point-of-Use Glassware Washers PresentationPoint-of-Use Glassware Washers Presentation
Point-of-Use Glassware Washers Presentation
 
Sfct e brochure
Sfct e brochureSfct e brochure
Sfct e brochure
 
Irrigation in endo ppt
 Irrigation in endo ppt Irrigation in endo ppt
Irrigation in endo ppt
 

Similar to 760235d bioshield brochure_web.pdf

Dental earosol
Dental earosolDental earosol
Dental earosolDrGhadooRa
 
Recent advances in endodontic irrigation devices
Recent advances in endodontic irrigation devicesRecent advances in endodontic irrigation devices
Recent advances in endodontic irrigation devicesDrAnuprabha Shrivastav
 
Infection Control Guidelines for Endoscopy Unit [compatibility mode]
Infection Control Guidelines for Endoscopy Unit [compatibility mode]Infection Control Guidelines for Endoscopy Unit [compatibility mode]
Infection Control Guidelines for Endoscopy Unit [compatibility mode]drnahla
 
Variety and summary
Variety and summaryVariety and summary
Variety and summaryandrewmidd
 
Flexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopes
Flexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopesFlexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopes
Flexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopesTalal Albudayri
 
Belgian interdisciplinary biofilm research sept 2016
Belgian interdisciplinary biofilm research   sept 2016Belgian interdisciplinary biofilm research   sept 2016
Belgian interdisciplinary biofilm research sept 2016OneLife SA
 
Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]drnahla
 
Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]drnahla
 
Sterilization and disinfection of orthodontic instruments /certified fixed or...
Sterilization and disinfection of orthodontic instruments /certified fixed or...Sterilization and disinfection of orthodontic instruments /certified fixed or...
Sterilization and disinfection of orthodontic instruments /certified fixed or...Indian dental academy
 
Sterilization /certified fixed orthodontic courses by Indian dental academy
Sterilization  /certified fixed orthodontic courses by Indian dental academy Sterilization  /certified fixed orthodontic courses by Indian dental academy
Sterilization /certified fixed orthodontic courses by Indian dental academy Indian dental academy
 
(Ng4)sterilization & amp; disinfection
(Ng4)sterilization & amp; disinfection(Ng4)sterilization & amp; disinfection
(Ng4)sterilization & amp; disinfectionIndian dental academy
 

Similar to 760235d bioshield brochure_web.pdf (20)

Dental earosol
Dental earosolDental earosol
Dental earosol
 
Aae 2011
Aae 2011Aae 2011
Aae 2011
 
Endoscope cleaning
Endoscope cleaningEndoscope cleaning
Endoscope cleaning
 
Recent advances in endodontic irrigation devices
Recent advances in endodontic irrigation devicesRecent advances in endodontic irrigation devices
Recent advances in endodontic irrigation devices
 
Infection Control Guidelines for Endoscopy Unit [compatibility mode]
Infection Control Guidelines for Endoscopy Unit [compatibility mode]Infection Control Guidelines for Endoscopy Unit [compatibility mode]
Infection Control Guidelines for Endoscopy Unit [compatibility mode]
 
Protection barriers
Protection barriersProtection barriers
Protection barriers
 
Irrigation manju.pptx
Irrigation manju.pptxIrrigation manju.pptx
Irrigation manju.pptx
 
Protection barriers
Protection barriersProtection barriers
Protection barriers
 
Variety and summary
Variety and summaryVariety and summary
Variety and summary
 
Love Moon
Love MoonLove Moon
Love Moon
 
Flexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopes
Flexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopesFlexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopes
Flexible Endoscopes.pdf Risks associated with reprocessing flexible endoscopes
 
Belgian interdisciplinary biofilm research sept 2016
Belgian interdisciplinary biofilm research   sept 2016Belgian interdisciplinary biofilm research   sept 2016
Belgian interdisciplinary biofilm research sept 2016
 
Perioscope
PerioscopePerioscope
Perioscope
 
Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]
 
Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]Infection Control Guidelines for Dental Clinics [compatibility mode]
Infection Control Guidelines for Dental Clinics [compatibility mode]
 
Sterilization and disinfection of orthodontic instruments /certified fixed or...
Sterilization and disinfection of orthodontic instruments /certified fixed or...Sterilization and disinfection of orthodontic instruments /certified fixed or...
Sterilization and disinfection of orthodontic instruments /certified fixed or...
 
Sterilization /certified fixed orthodontic courses by Indian dental academy
Sterilization  /certified fixed orthodontic courses by Indian dental academy Sterilization  /certified fixed orthodontic courses by Indian dental academy
Sterilization /certified fixed orthodontic courses by Indian dental academy
 
Sterilization
Sterilization Sterilization
Sterilization
 
(Ng4)sterilization & amp; disinfection
(Ng4)sterilization & amp; disinfection(Ng4)sterilization & amp; disinfection
(Ng4)sterilization & amp; disinfection
 
Perio handout
Perio handoutPerio handout
Perio handout
 

More from Matías Hernández López

760746a infinity intl_ss_web.pdf (from bel_air)
760746a infinity intl_ss_web.pdf (from bel_air)760746a infinity intl_ss_web.pdf (from bel_air)
760746a infinity intl_ss_web.pdf (from bel_air)Matías Hernández López
 

More from Matías Hernández López (20)

960004a new featured 2011 us_web.pdf
960004a new  featured 2011 us_web.pdf960004a new  featured 2011 us_web.pdf
960004a new featured 2011 us_web.pdf
 
760746a infinity intl_ss_web.pdf
760746a infinity intl_ss_web.pdf760746a infinity intl_ss_web.pdf
760746a infinity intl_ss_web.pdf
 
760746a infinity intl_ss_web.pdf (from bel_air)
760746a infinity intl_ss_web.pdf (from bel_air)760746a infinity intl_ss_web.pdf (from bel_air)
760746a infinity intl_ss_web.pdf (from bel_air)
 
760510b biovac mishkin case report web.pdf
760510b biovac mishkin case report web.pdf760510b biovac mishkin case report web.pdf
760510b biovac mishkin case report web.pdf
 
760508a advance case report 3 web.pdf
760508a advance case report 3 web.pdf760508a advance case report 3 web.pdf
760508a advance case report 3 web.pdf
 
760449b fb checklist_8 5_11_web.pdf
760449b fb checklist_8 5_11_web.pdf760449b fb checklist_8 5_11_web.pdf
760449b fb checklist_8 5_11_web.pdf
 
760389a aquashield intl_ss.pdf
760389a aquashield intl_ss.pdf760389a aquashield intl_ss.pdf
760389a aquashield intl_ss.pdf
 
760383b exacto intl_ss_web.pdf
760383b exacto intl_ss_web.pdf760383b exacto intl_ss_web.pdf
760383b exacto intl_ss_web.pdf
 
760375b traxtion intl_ss_web.pdf
760375b traxtion intl_ss_web.pdf760375b traxtion intl_ss_web.pdf
760375b traxtion intl_ss_web.pdf
 
760358c entrada intl_ss_web.pdf
760358c entrada intl_ss_web.pdf760358c entrada intl_ss_web.pdf
760358c entrada intl_ss_web.pdf
 
760352 b talon_intl_ss.indd
760352 b talon_intl_ss.indd760352 b talon_intl_ss.indd
760352 b talon_intl_ss.indd
 
760348c hemostasis checklist_web.pdf
760348c hemostasis checklist_web.pdf760348c hemostasis checklist_web.pdf
760348c hemostasis checklist_web.pdf
 
760346e velocity intl_ss__web.pdf
760346e velocity intl_ss__web.pdf760346e velocity intl_ss__web.pdf
760346e velocity intl_ss__web.pdf
 
760321c boost ss web.pdf
760321c boost ss web.pdf760321c boost ss web.pdf
760321c boost ss web.pdf
 
760279a biovac whitepaper_web.pdf
760279a biovac whitepaper_web.pdf760279a biovac whitepaper_web.pdf
760279a biovac whitepaper_web.pdf
 
760269c rothnet brochure web.pdf
760269c rothnet brochure web.pdf760269c rothnet brochure web.pdf
760269c rothnet brochure web.pdf
 
731495b advance qrg ltr size bleed web.pdf
731495b advance qrg ltr size bleed web.pdf731495b advance qrg ltr size bleed web.pdf
731495b advance qrg ltr size bleed web.pdf
 
96503 ec2b2b7521d
96503 ec2b2b7521d96503 ec2b2b7521d
96503 ec2b2b7521d
 
81709 pessaryinservice.qrk layout 1
81709 pessaryinservice.qrk layout 181709 pessaryinservice.qrk layout 1
81709 pessaryinservice.qrk layout 1
 
005574 b.pdf
005574 b.pdf005574 b.pdf
005574 b.pdf
 

760235d bioshield brochure_web.pdf

  • 2. BioShield® biopsy valves and irrigation accessories are single-use, offering unsurpassed protection for patients and staff. Why single-use valves? It is nearly impossible to manually clean, disinfect, flush and dry biopsy valves. Reused biopsy valves can become leaky and potentially harbor dangerous pathogens - putting both patients and healthcare workers at risk. Fortunately, BioShield® biopsy valves are single-use, leaving you one less thing to worry about. Why take the risk? Trust BioShield® biopsy valves.
  • 3. BioShield® biopsy valve economy 00711125/00711135 Olympus/Fujinon 00711136 Pentax It just makes sense Single-use valves reduce the possibility of cross-contamination between patients. Small valve size and easy device passage offer exceptional fuctionality during usage. 1136 Pentax 1125/1135 Olympus/Fujinon
  • 4. Did you know? Findings suggest biopsy valves aren’t designed to be cleaned and reprocessed… FACT: The design of a biopsy valve FACT: Biopsy valves have internal inhibits the reach and effectiveness of flaps that squeegee biomaterial off cleaning brush bristles, making it nearly devices as they are extracted, allowing impossible to remove debris from it to collect deep within the valve’s inner inner crevices crevices Arrows show insufficient contact of cleaning brush bristles within internal crevices Play it safe...US Endoscopy’s line of BioShield® biopsy valves are single-use so you no longer have to worry about what lingers in those hidden crevices what the experts are saying “...cleaning brush bristles must come in contact with all surfaces of the 1 endoscope channel, parts, connectors and orifices before reuse is safe.” “Air pockets in the biopsy-port caps that prevented effective contact between disinfectants and the microorganisms when submerged during cleaning were pinpointed as the culprits of the spreading bacteria. Also, the design of the caps prevented thorough cleaning and drying of surfaces inside the caps, thus providing an environment where the bacteria could survive the usual disinfection procedures, according to doctors.” 2 “Rubber biopsy port caps must be discarded after all procedures involving the passage of biopsy forceps, guidewires and/or other accessories through the endoscope.” 3 “...healthcare-related infections from endoscopy continue to occur, in part, because endoscopes are difficult to clean due to their complex nature, which includes “springs and valves” as parts of the endoscope that complicate adequate disinfection.” 4
  • 5. In a documented study,* published in EndoNurse and Infection Control Today, researchers found visible debris/proteinaceous material in over 50% of the test valves. The reprocessed valves used in the study, supplied from three major U.S. institutions, were deemed “clean and ready to use” prior to microscopic evaluation. The results showed wear and damage to valve structure, gross contamination on the outer edges, and contamination within the nooks and crannies of the valves - where cleaning brushes can’t always reach. (Figure 1.2-1.4 taken from David M. Parente, BS, BA, MBA, “Could Biopsy Port Valves be a Source for Potential Flexible Endoscope Contamination,” Infection Control Today, Volume 11, No. 6, (June 2007). Contamination Contamination in nooks and crannies of valve Contamination along edge of opening Fig 1.2 - Valve observed during Fig 1.3 - Internal cross section of valve Fig 1.4 - Valve observed during microscopy demonstrates wear and observed at magnification of approxi- microscopy at 10x magnification. damage after use, manual cleaning mately 10x demonstrates presence of Note the presence of pinkish droplets and high-level disinfecting. Note the contamination in nooks and crannies on the edge of the valve opening, presence of contamination along of valve. representing gross contamination. edge of the opening. related articles • Society of Gastroenterology Nurses and Associates, Inc., “Position Statement, Reprocessing of Endoscopic Accessories and Valves,” Gastroenterology Nursing, Volume 25, No. 5, (September/October 2002). • WGO / OMED, “Practice Guideline: Endoscope Disinfection,” World Gastroenterology News, Volume 11, Issue 1, (Spring 2006). • K. M. Mohandas, “Mucocutaneous exposure to body fluids during digestive endoscopy: the need for universal precautions,” Indian Society of Gastroenterology, Volume 19, (July-September 1999). Source 1: American Society for Gastrointestinal Endoscopy and the Society for Healthcare Epidemiology of America, “Multi-society guideline for reprocessing flexible gastrointestinal endoscopes,” Gastrointestinal Endoscopy, Volume 58, No. 1, (2003). Source 2: Jon Coomer, “Investigative team exposes equipment dangers,” New England Journal of Medicine, (2003). Source 3: Endoscopy Committee, British Society of Gastroenterology, “BSG Guidelines For Decontamination of Equipment for Gastrointestinal Endoscopy,” BSG Working Party Report, (February 2008). Source 4: Kelly M. Pyrek, “Nooks and Crannies: The Breeding Grounds for Bacteria,” Infection Control Today, (June 2002). Source*; David M. Parente, BS, BA, MBA, “Could Biopsy Port Valves be a Source for Potential Flexible Endoscope Contamination,” Infection Control Today, Volume 11, No. 6, (June 2007).
  • 6. BioShield® irrigator Imagine being able to... flush blood, exudate and other debris out of your way at anytime throughout a procedure*- even with a device in place 1133 reduce frustration and wasted time spent exchanging devices and syringes just to cleanse your field of view How important is a clear view? The BioShield® irrigator affords immediate, direct, intraprocedural irrigation. Simply attach a 60cc syringe to the irrigation line, or use extension tubing to connect with 00711133 your water pump for hands-free, foot pedal Olympus/Fujinon control. 00711137 Pentax (not pictured) Add a whole new level of efficiency to your endoscopy procedures with the BioShield® irrigator immediate, direct irrigation with device in channel *In order to achieve moderate irrigation pressure and minimize leakage, there must be sufficient room within the biopsy channel for fluid to pass when there is a device in place
  • 7. product information part number description length qty/box (cm) Olympus & Fujinon (G5 series and newer) compatible 00711135 BioShield® biopsy valve - economy — 100 00711125 BioShield® biopsy valve - economy (20 per pack/10 packages) — 200 00711133 BioShield® irrigator 30.5 50 00711138 BioShield® biopsy valve ERCP — 25 Pentax compatible 00711136 BioShield® biopsy valve - economy — 100 00711137 BioShield® irrigator 30.5 50 adaptor length qty/box universal irrigation accessories gauge (cm) 00711131 universal irrigating adaptor 15 2.54 50 (adaptor) 00711134 universal water pump extension tubing — 180 50 Listening…and delivering solutions®, the US Endoscopy listening…and delivering solutions design, and all marks denoted with ® or ™ are registered with the U.S. Patent and Trademark Office, or trademarks owned by US Endoscopy BioShield® biopsy valves are intended to be used with gastrointestinal endoscopes. Fujinon® is a registered trademark of Fuji Film Co., Ltd. Olympus® is a registered trademark of Olympus Optical, Inc. PENTAX® is a registered trademark of Asahi Kogaku Kogyo Kabushiki Kaisha.
  • 8. 5976 Heisley Road Mentor, OH 44060 phone (1) 440 / 639-4494 fax (1) 440 / 639-4495 customer service (1) 800 / 769-8226 760235 Rev. D