Your SlideShare is downloading. ×
MYNAH Technologies LLC: Migration from RSTestStand to MiMiC Simulation Software
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

MYNAH Technologies LLC: Migration from RSTestStand to MiMiC Simulation Software

721
views

Published on

The use of IO simulation for control system testing and Factory Acceptance Test is a proven best practice. Users of RSTestStand can now upgrade to a full dynamic simulation. We will discuss the …

The use of IO simulation for control system testing and Factory Acceptance Test is a proven best practice. Users of RSTestStand can now upgrade to a full dynamic simulation. We will discuss the process and benefits of migrating to MiMiC.

Published in: Technology

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
721
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
8
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. PUBLIC INFORMATION Migration from RSTestStand to MiMiC Simulation Software MYNAH Technologies LLC
  • 2. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. RSTestSTand TM to MiMiC Migration RSTechED 2014, Orlando, FL © 2014 MYNAH Technologies LLC
  • 3. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. MiMiC Virtual Plant for PlantPAxTM
  • 4. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 4 Virtual Plant with Rockwell PLCs
  • 5. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 5 Virtual Plant with Soft Controllers
  • 6. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 6 RSTestStandTM Migration to MiMiC Manually Convert RSTestStandTM Developed in partnership Tested in partnership Documented approach
  • 7. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 7 How to Get Started … o RSTestStand TM -> MiMiC Relationships o Identifying Important Resource/Model information o Establishing Real-time Communications o Building Instructor Interface
  • 8. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 8 Resource -> Model
  • 9. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 9 Variable Tags -> SIOTag
  • 10. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 10 Operator Console -> Component Studio
  • 11. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 11 Converting a StdResource StdResources MiMiC equivalent models
  • 12. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 12 Converting a Non-StdResource 1. Open the logic flowchart (logic view) 2. Check if standard (non- calc) blocks in MiMiC can model a given flowchart process 3. Model the flowchart in a calc block
  • 13. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 13 Resource Flowchart
  • 14. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 14 Resource Variable Properties
  • 15. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 15 Resource Variable Tags
  • 16. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 16 Generating SIOTags Ethernet/IP OPC .L5K
  • 17. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 17 Add Tags to MiMiC with TagBrowser
  • 18. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 18 Quickly Add OPC Items
  • 19. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 19 Mapping Tags to Blocks Add all SIOTag to Simulation Node Assign SIOTag to each AI and AO block Read Multiple bits – BFO
  • 20. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 20 Creating MiMiC Instructor Interface One-to-one connections One-to-many connections
  • 21. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. 21 Mirroring RSTestStand TM Interface Consoles OPConsole Devices MiMiC equivalent Console Items
  • 22. www.mynah.com ISO 9001-2008 Certified. © 2014 MYNAH Technologies LLC. All rights reserved. Dynamic Simulation Leader Over MiMiC 1300 Registered Sites Globally World-class Software Development Team World-class Simulation Consultants Rockwell Automation Encompass Partner for Dynamic Process Simulation MYNAH – Simulation Leader 2014 Readers Choice #1 Simulation Software 2006, 2007, 2008, 2010, 2011, 2012, 2013 Winner Contact Jay Chard, jay.chard@mynah.com, +1.636.728.2025
  • 23. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. www.rsteched.com Follow RSTechED on Facebook & Twitter. Connect with us on LinkedIn. PUBLIC INFORMATION Thank you. Questions?

×