Your SlideShare is downloading. ×
FactoryTalk View SE - Implementing FactoryTalk Alarms and Events Lab
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

FactoryTalk View SE - Implementing FactoryTalk Alarms and Events Lab

5,250
views

Published on

This hands-on lab focuses on how to best implement and configure FactoryTalk Alarms and Events with FactoryTalk View SE and Logix. Understand the Rockwell Automation alarming strategy. See the …

This hands-on lab focuses on how to best implement and configure FactoryTalk Alarms and Events with FactoryTalk View SE and Logix. Understand the Rockwell Automation alarming strategy. See the time-saving features of using FactoryTalk VantagePoint EMI to produce alarm reports and advanced alarm summaries. See the newest features driving ISA 18.2 alignment, including shelved state capability and alarm commands & summary. Other topics will include subscriptions, alarm fi ltering and converting HMI alarms to tag-based FactoryTalk alarms. Setting up the newly released FactoryTalk Alarms and Events Server redundancy will also be covered.

Published in: Technology

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
5,250
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900DFactoryTalk View Site Edition:Implementing FactoryTalk Alarms and EventsTony CarraraProduct ManagerRockwell Automation
  • 2. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.FactoryTalk Visualization Products2FactoryTalk ViewPointWeb-Based HMIWeb-Based HMIFactoryTalk ViewMachine EditionElectronic Operator InterfaceElectronic Operator InterfacePanelView™ Plus and CompactPanelView™ Plus and CompactFactoryTalk ViewSite EditionScalable PC Based HMIScalable PC Based HMIIndustrial and Non-Industrial Computers andMonitorsIndustrial and Non-Industrial Computers andMonitors
  • 3. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved. 3FactoryTalk View SE DistributedFactoryTalk View SE StationClientsRSLinxServersView SEServersView StudioDevelopmentStationFactoryTalkDirectoryServerCommon developmentenvironment withFactoryTalk View StudioCommon developmentenvironment withFactoryTalk View StudioScalable from a single station up to a distributed client / server architectureScalable from a single station up to a distributed client / server architectureFactoryTalk View Site Edition
  • 4. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved. 4• Alarm instructions available in the Logixfamily of controllers.• The controller detects alarm conditions andtriggers alarm events• The FactoryTalk Alarms and Events servercaptures all of the controller events andsends notification to connected clients• Information is displayed in the AlarmManagement components on the clients• Alarm instructions available in the Logixfamily of controllers.• The controller detects alarm conditions andtriggers alarm events• The FactoryTalk Alarms and Events servercaptures all of the controller events andsends notification to connected clients• Information is displayed in the AlarmManagement components on the clientsDevice-BasedAlarms• Software-based alarm servers poll data tagsfor alarm conditions.• The Alarm server detects alarm conditionsand triggers alarm events• The FactoryTalk Alarms and Events servercaptures all of the controller events andsends notification to connected clients• Information is displayed in the AlarmManagement components on the clients• Supports PLC-5®, SLC™ 500, or any third-party device through OPC-DA• Software-based alarm servers poll data tagsfor alarm conditions.• The Alarm server detects alarm conditionsand triggers alarm events• The FactoryTalk Alarms and Events servercaptures all of the controller events andsends notification to connected clients• Information is displayed in the AlarmManagement components on the clients• Supports PLC-5®, SLC™ 500, or any third-party device through OPC-DATag-Based Alarms Two different types of alarm sources:FactoryTalk Alarms and Events
  • 5. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Information Integration• Enhanced integration with Rockwell Automation Information SoftwareProducts like FactoryTalk VantagePoint and FactoryTalk Historian MachineEdition and Site EditionInformation Integration• Enhanced integration with Rockwell Automation Information SoftwareProducts like FactoryTalk VantagePoint and FactoryTalk Historian MachineEdition and Site EditionProcess Industry Support• Improved operator effectiveness related to alarm management and run timeHMI navigation• Expanded System Limits• Tighter alignment with Alarming Standard ISA 18.2Process Industry Support• Improved operator effectiveness related to alarm management and run timeHMI navigation• Expanded System Limits• Tighter alignment with Alarming Standard ISA 18.2Usability• Streamlined Installation Process• Enhanced design-time capabilities• Improved run-time graphicsUsability• Streamlined Installation Process• Enhanced design-time capabilities• Improved run-time graphics5FactoryTalk View Site Editionrelease date: January 2013
  • 6. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved. 6• Configuration andMaintenance Lab• Configuration andMaintenance LabVZ04VZ04• BuildingApplicationsLab• BuildingApplicationsLabVZ05VZ05 • ImplementingFactoryTalkAlarms andEvents• ImplementingFactoryTalkAlarms andEventsVZ06VZ06RSTechED LabsRSTechED LabsFactoryTalk View Site Edition
  • 7. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.What’s this Lab about?7Setting up A&ESetting up A&E Alarm filteringAlarm filteringRemoteCommandsRemoteCommandsShelvingShelvingConverting HMIalarms to tag-based FactoryTalkalarmsConverting HMIalarms to tag-based FactoryTalkalarmsFactoryTalk Alarms and Events
  • 8. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900DQuestions?
  • 9. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Rev 5058-CO900DThank you for participating!Please remember to tidy up your work area for the next session.We want your feedback! Please complete the session survey!VZ06 - FactoryTalk® View Site Edition:Implementing FactoryTalk Alarms and Events
  • 10. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.What’s New in FactoryTalk View SE 7.0?Supplemental Slides
  • 11. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.FactoryTalk View Site Edition v7.0Released in January 2013Information Integration• Enhanced integration with Rockwell Automation Information SoftwareProducts like FactoryTalk VantagePoint and FactoryTalk Historian MachineEdition and Site EditionInformation Integration• Enhanced integration with Rockwell Automation Information SoftwareProducts like FactoryTalk VantagePoint and FactoryTalk Historian MachineEdition and Site EditionProcess Industry Support• Improved operator effectiveness related to alarm management and run timeHMI navigation• Expanded System Limits• Tighter alignment with Alarming Standard ISA 18.2Process Industry Support• Improved operator effectiveness related to alarm management and run timeHMI navigation• Expanded System Limits• Tighter alignment with Alarming Standard ISA 18.2Usability• Streamlined Installation Process• Enhanced design-time capabilities• Improved run-time graphicsUsability• Streamlined Installation Process• Enhanced design-time capabilities• Improved run-time graphics11
  • 12. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.TrendX Support for Historian ME12OverviewBenefitsFactoryTalk View Site Edition TrendX now supportsshowing historical data being collected by one ormore FactoryTalk Historian ME modules. FactoryTalk View Site Edition Distributed andNetwork Site Edition Station can directlymonitoring data from Historian ME module. Data from multiple FactoryTalk Historian MEmodules can be shown on one TrendX.VSE
  • 13. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.FactoryTalk VantagePoint Trend13OverviewOverviewTo gain better access to VantagePoint data, youcan now use the VantagePoint v4.5 Trend ActiveXwith FactoryTalk View Site Edition 7.0To gain better access to VantagePoint data, youcan now use the VantagePoint v4.5 Trend ActiveXwith FactoryTalk View Site Edition 7.0OverviewTo gain better access to VantagePoint data, youcan now use the VantagePoint v4.5 Trend ActiveXwith FactoryTalk View Site Edition 7.0BenefitsBenefits All the power of the FactoryTalk VantagePointTrend from a FactoryTalk View SE screen. Create new trends at runtime and publish backinto FactoryTalk VantagePoint model. All the power of the FactoryTalk VantagePointTrend from a FactoryTalk View SE screen. Create new trends at runtime and publish backinto FactoryTalk VantagePoint model.Benefits All the power of the FactoryTalk VantagePointTrend from a FactoryTalk View SE screen. Create new trends at runtime and publish backinto FactoryTalk VantagePoint model.VSE
  • 14. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Expanded FactoryTalk View Site EditionStation Capabilities14OverviewBenefitsNetwork View SE Station is a new application typeselection for FactoryTalk View Site Edition 7.0.Network View SE Station expands the capabilityof single HMI stations for security and dataaccess.No new catalog numbers – same Stationlicense can be used. Enables FactoryTalk View SE Station to accessNetwork Scope products like FactoryTalkHistorian ME and SE and FactoryTalk Batch. Supports off-box RSLinx Enterprise DataServer that can be configured for redundancy.Network Scope FTNetwork Scope FTView SE StationView SE DistributedHistorian SEVSE
  • 15. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Simplified Installation Process15OverviewBenefitsBrand new installation workflow that streamlinesand simplifies the process of installing FactoryTalkView Site Edition systems. Allows user to pick main role of the targetcomputer. Automates IIS installation, when required, onnewer operating systems Once all information is entered, steps throughthe required order of installation automatically.VMEVSE
  • 16. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Answering the Call for Larger Systems16Benefits Synchronizes architecture limits to simplifydecision making. Expands the number of clients and serversusing FactoryTalk Alarms and Events. Removes architecture barriers to FactoryTalkAlarms and Events adoption.OverviewTo meet the growing demand for larger systems,FactoryTalk View Site Edition 7.0 has expandedpast server and client limits allowed in oneapplication.FactoryTalk A&E ClientsFactoryTalk A&E ClientsRedundant FT View SEServer PairsRedundant FT View SEServer PairsRedundant FTAE ServerPairsRedundant FTAE ServerPairs2050V6.1 V7.0510V6.1 V7.0210V6.1 V7.02.5x 2x 5xVSE10 Redundant Pairs / 50 Clients10 Redundant Pairs / 50 Clients
  • 17. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Improved Alarm Management17OverviewBenefitsTo align with ISA Standard 18.2, FactoryTalkAlarms and Events 2.60 will support the ShelvedState. Shelving an alarm is similar to suppressing analarm but with an expiration time. ISA 18.2 aligns suppress as a programmaticcommand that should not be exposed to anoperator.New Shelve buttonsavailable on AlarmSummaryEnter shelve timeduration andcommentsVSE
  • 18. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Broadening our Alarming Capabilities18OverviewBenefitsFactoryTalk Alarms and Events 2.60 (CPR 9 SR 6)Tag Based Alarms allows HMI Faceplates to issuealarm commands without forcing the user to go tothe alarm summary. Further empowers PlantPAx faceplatecapabilities for all Tag Based AlarmCommands. New commands supported: Shelve, Unshelve,Enable, Disable, Suppress, UnsuppressFTAE Tag BasedServerFTAE Tag BasedServerIssue alarm commands fromAlarm Summary and Device FaceplatesIssue alarm commands fromAlarm Summary and Device FaceplatesVSE
  • 19. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Improving Operator Effectiveness19OverviewBenefitsTo improve operator effectiveness, we introduce anew navigation button and commands thatfunction in a similar fashion to a web browsersback, forward, and history buttons. Removes need for VBA scripting to trackscreens. Simplifies navigation strategies so users canquickly get to the screen they need. Offers flexibility for choosing the screens youwant to track and enter a user friendly name fordisplay in history.VSE
  • 20. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Increasing Design Time Productivity20OverviewBenefitsFactoryTalk View Studio in 7.0 adds Find andReplace capabilities for Displays and GlobalObjects and a Cross Reference for finding tagsthroughout the system. Find and Replace searches for Tags andStrings located in objects on Displays andGlobal Objects. Cross Reference can find tags and strings inthe Tag Database, Displays, Global Objects,Parameter files, Macros, and Data Logs.VMEVSE
  • 21. Copyright © 2013 Rockwell Automation, Inc. All Rights Reserved.Enhanced Graphic Look and Feel21OverviewBenefitsFactoryTalk View Site Edition 7.0 enables users tocreate better, more appealing graphics while stillmaintaining operator effectiveness with the newGradient Shading capability and support for PNGgraphic types. Improve the look and feel of native FactoryTalkView Site Edition shapes, buttons,backgrounds, and more. Add gradient shading in ways that enhancesHMI Screens but not to distract operator fromtasks PNG Graphic types better support backgroundtransparency to make buttons stand out.VMEVSE