More Related Content
Similar to Presentazione IBM System Storage - Evento Torino 19 novembre 2013
Similar to Presentazione IBM System Storage - Evento Torino 19 novembre 2013 (20)
More from PRAGMA PROGETTI
More from PRAGMA PROGETTI (20)
Presentazione IBM System Storage - Evento Torino 19 novembre 2013
- 1. Verso un nuovo “Risorgimento” tecnologico – Torino – Ore 9,30
IBM System Storage® : la famiglia si allarga…ultimi
annunci
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
1
© 2013 IBM Corporation
For IBM
and IBM BP education use only.
- 2. What is Software Defined Storage?
IBM Definition
2
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 3. Software-defined storage – V1.0
Virtualize and Optimize
Storwize is SW defined Storage
• SVC Virtualized from Birth in 2003
• Extended to Storwize HW Platforms 2010+
• Over 150 Heterogeneous disk array supported
Storwize Platform
• History of efficiency and optimization
• Thin Provisioning
• Easy Tier
• Real-time Compression
Software Defined
Storage 1.0
Virtualize and
Optimize
3
© 2013 IBM Corporation
Real Time
Compression
EasyTier
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 4. Software-defined storage – V2.0
Open and Extensible
Other ISVs
Datapath API
Mgmt. API
Software-defined
storage 2.0
Object
Store
Cloud
GW
Copy
Data
File Sync
& Share
Virtual
DBs
Storwize as Software Platform
Open,
Extensible
and
Industry-led
4
© 2013 IBM Corporation
Industry Standard Hardware
•
•
•
Open platform – industry driven innovation
APIs for application driven management
Traditional and new delivery models
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 5. Software-defined Storage – V3.0
Industry Led and Application Driven
• Storwize AppCenter for industry led innovation
Storwize AppCenter
o Apps written and tested by 3rd party ISVs
o Users choose and upload apps from AppCenter
App
Upload
App
Upload
o IBM provides certification and integration support
App
Upload
App
Upload
App
Upload
App
Upload
App
Upload
App
Upload
• Programmatic API for application driven control
o REST API for programmatic platform management
o Server Applications controls apps running on the
Storwize platform
Software Defined
Storage 3.0
Open,
Analytic
and
Application
Driven
5
© 2013 IBM Corporation
REST API
Object
Store
Cloud
GW
Copy
Data
File
Sync &
Share
Virtual
DBs
Storwize as Software Platform
Industry Standard Hardware
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 6. Software Defined Storage – SDS
Here today, ready for tomorrow
Virtualize and
Optimize
Open,
Extensible
and Industryled
Open,
Analytic and
Application
Driven
IBM Storwize Platform
Storwize V3700
6
Storwize V5000
© 2013 IBM Corporation
Storwize V7000
Storwize V7000
Unified
Flex System
V7000
SAN Volume
Controller
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 7. Storwize Family Continuing Delivery of Enhanced Capability and Value
October 2010
November 2012
October 2013
New Standard for
Midrange Storage
Storwize V7000
2010
October 2011
Unified Storage
Active Cloud
Engine
Storwize V7000
Unified
Storwize V3700
Flex System
V7000
IP replication
Integrated SANSlide
Mobile dashboard
Enhanced Stretched
Cluster
Storwize V5000
2011
2012
2013
May 2011
© 2013 IBM Corporation
June 2013
Clustering
VMware APIs
10Gb iSCSI
7
April 2012
Real-time
Compression
FCoE
Storwize V3700
enhancements
Compression performance
Easy Tier and compression
Capacity and VM scalability
Global Active Cloud Engine
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 8. Storwize Family Significant Milestones Through March
Over 36,000 systems purchased
Includes Storwize V7000, Flex System V7000,
Storwize V5000, Storwize V3000 and
Storwize V7000 Unified systems
In addition, over 10,000 SVC systems
Over 80,000 total enclosures deployed
Averaging more than 2 expansion units per system
(Storwize V7000)
Over 1.1 exabytes of capacity
That’s over a million TB
Delivering five nines availability
8
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 9. IBM Storwize Family Enhancements
IBM Storwize Family Software Version 7.2
GA: November 29
Next generation software defined storage platform
– Accelerating delivery of new value with integrated third-party function
IP replication with integrated Bridgeworks SANSlide network optimization
– Lower cost option with up to 3x better network utilization
Real-time Compression enhancements
– Up to 3x better throughput for VMware vMotion and 35% reduced CPU utilization
IBM Storage Mobile Dashboard
– Monitoring and health check for Storwize family systems from mobile devices
VMware 5.5 and VASA block support
– Maintains currency with latest VMware capabilities
SAS data migration
– Nondisruptive migration from existing SAS storage to Storwize V3500, Storwize V3700
and V5000
Enhanced stretched cluster for SVC
– Optimizes inter-site networking and enables planned site failover
800GB solid-state drives (SSDs)
GA: December 6
SVC, Storwize V3700, Storwize V5000, Storwize V7000 [Unified], Flex System V7000
Support larger flash configurations, lower cost
Storwize V5000
GA: October 11
Highly flexible, easy-to-use, virtualized storage system
9
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 10. IP Replication
SVC
Source
Volume
V3000
V5000
V7000
Enables use of ethernet connections for
remote mirroring
Transparent to servers and applications
Supports all remote mirroring modes
– Global Mirror with Change Volumes
preferred
Straightforward configuration on existing IP
infrastructure
Includes Bridgeworks SANSlide network
optimization technology
No additional charge
Available for all Storwize family members
except Storwize V3500
TCP/IP
Network
Destination
Volume
10
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 11. Bridgeworks SANSlide
SVC
V3000
IP connections may have long latency
– Long distance connections
– Many network “hops”
Traditional solutions transmit data, wait for response,
transmit more data
– Results in poor network utilization, as low as 20%
– Worse as latency becomes higher
Bridgeworks SANSlide technology integrated with
Storwize family IP replication
– No separate appliances required
– No additional cost
Uses artificial intelligence technology to transmit data streams in
parallel
– Automatically adjusts to changing network latency
– Improves network bandwidth utilization up to 3x
– Independent of application or data type
Deploy less costly network infrastructure
Speed replication cycles for better remote data currency and
faster recovery
11
© 2013 IBM Corporation
V5000
V7000
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 12. Value of IP Replication with Bridgeworks SANSlide Technology
SVC
V3000
V5000
V7000
Major customer requirement
Simpler: Eliminate FC-IP routers and network
optimization appliances
Independent: Eliminate CPU and management
overhead of using server-based solutions
More efficient: Significantly improve network
utilization
Flexible: Delivers benefits regardless of
workload or data type
Cheaper: Deploy less expensive networking
infrastructure and eliminate need for dark fibre
Better: Reduce impact of disasters by
copying data more quickly
12
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 13. Comparing FC-IP repl. with IP repl. using Bridgeworks SANSlide
SVC
V3000
V5000
V7000
3x
throughput
13
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 14. Real-time Compression Enhancements
SVC
New LZ4 compression algorithm
Delivers significant throughput increase at the cost of a fraction of the savings
Automatically used when new data written, even for existing compressed volumes
Up to 3x higher sequential write throughput (minor read improvement – 15%)
– Faster VMware vMotion sessions
– More VMware vMotion sessions in parallel
– More FlashCopy sessions in parallel
V7000
Uses 35% less CPU resources for the same workload compared to version 7.1
Delivers 35% more throughput (IOPS) for random I/O workloads
Benefit: Compress more VMware, Oracle, DB2, and MS-SQL workloads
Hot-cold I/O segregation
Makes physical placement of compressed data better for Easy Tier
Increases Easy Tier efficiency
Benefit: Improve application performance for more data
14
© 2013 IBM Corporation
* Actual customer experience
** Projected
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 15. IBM Storage Mobile Dashboard
SVC
V3000
V5000
V7000
iPhone app provides monitoring and health checking for Storwize family systems
– Available free from Apple App Store
15
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 16. SAS Data Migration
V3000
V5000
16
Enables straightforward nondisruptive migration from existing SAS storage
Available for Storwize V3500, Storwize V3700 and Storwize V5000
Supports migration from DS3200 and DS3500 only
Not intended for general-purpose storage virtualization
Supported with any host attachment technology
Speeds implementation and minimizes disruption when
deploying new storage
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 17. Enhanced Stretched Cluster
SVC
Existing stretched cluster support limitations
– No manual failover capability
– Solution typically sends data across the long distance link twice
Addressed by adding concept of ‘site awareness’
– Route IO traffic between the nodes and controllers to optimize data flow
– Police IO traffic in failure conditions to allow manual cluster invocation to ensure
consistency
Support notes
– Stretched cluster hardware installation guidelines remain the same
– Use of enhanced stretch cluster is optional, existing stretch cluster configurations will
continue to be supported, however customers are encouraged to use the new feature for
its benefits
– Should be possible to convert an existing stretched cluster to an enhanced stretch
cluster non-disruptively any time after upgrade has completed
17
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 18. IBM SmartCloud Storage Access R1.2
Self service storage provisioning for IBM block storage systems:
XIV, Storwize V7000, SVC
Cloud, Dept
Cloud service
Developers
– Enables web-based on demand self-service provisioning of admin
users
Testers
storage capacity, improves user productivity and increases
operational efficiency
– Allows administrators to define storage classes with different
“service profiles” for cost reduction
REST API support
– Enables wider support with ISV solutions
new
SCSA Instrumentation Layer
Storage usage metrics export function
– Enables charge-back through any reporting/accounting/billing
application
Federated authentication
Storwize
– Allows for collaboration with other institutions for file
family
SONAS
XIV
sharing, content storage
new
new
Support for lower cost “SmartCloud Storage Access
Instrumentation Layer”
LEARN MORE: IBMers BPs
– Offers a lower cost TPC option for infrastructure management
(orderable only with SCSA R1.2)
Read brochure
Watch the video
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
18
- 19. Introducing Storwize V5000 system
Latest addition to the Storwize family delivers outstanding benefits
with greater flexibility
• Simplify management efforts with industry-leading graphical
user interface
• Boost performance up to three times using only five percent
flash storage with optional IBM® System Storage® Easy
Tier® technology
• Consolidate and provide IBM Storwize® V5000 capabilities
to existing storage infrastructures using optional external
virtualization
• Easily customize your system with flexible software options
• Improve network utilization for remote mirroring with
innovative replication technology
• Enable growth from the smallest configurations with two-way
clustered systems
19
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 20. Storwize V5000: Flexible, efficient midrange Storwize system
Enclosures contain up to twelve LFF (3.5”) or twenty-four SFF (2.5”) drives in just 2U
Control enclosure: dual active-active controllers and drives
– 16 GB Cache (8 GB per controller) standard; 32 GB Cache with two-way clustered systems
– 1Gb iSCSI, 6 Gb SAS and 8 Gb FC or 10Gb iSCSI/FCoE host ports standard
Expansion enclosure:
– Up to six expansion enclosures
– Up to 168 SFF or 84 LFF drives for up to 336 TB capacity
– Up to 672 TB capacity with two-way clustered systems
RAID levels 0, 1, 5, 6, and 10
Redundant, hot-swappable components (i.e., power supplies and fans)
Optional Software: Easy Tier, External Virtualization, Remote Mirroring (over FC, FCoE and IP –
Ethernet) and FlashCopy
Storwize V5000 models are available with either a one year or three year warranty: models ordered
using machine type 2077 have a 1 year warranty; models with machine type 2078 have 3 year warranty
20
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 21. Storwize V3700, Storwize V5000 and Storwize V7000 comparison*
Storwize V3700
Storwize V5000
Storwize V7000
Typical customer
storage budget
$10,000 - $ 15,000 Dlls
$15,000 - $ 40,000 Dlls
$40,000 - $ 100,000 Dlls
Management SW
Storwize V3700 machine code
IBM Storwize Family Software for Storwize
V5000
IBM Storwize Family Software for Storwize
V7000
Capacity
Up to 120 drives per control enclosure
(up to 4 expansions)
Up to 168 drives per control enclosure (up to
Up to 240 drives per control enclosure; 960
6 expansions); 336 per clustered system
per clustered system (four clusters)
(two-way clustering)
Standard Host Ports
1Gb iSCSI, 6Gb SAS
1Gb iSCSI, 6Gb SAS, 8Gb FC or 10Gb
iSCSI/FCoE
1Gb iSCSI, 8Gb FC
Optional Host Ports
iSCSI 10Gbps, FC, FCoE
N/A
iSCSI 10Gbps, FCoE
Cache (dual ctl)
8GB upgradeable to 16GB
16GB per dual controller, to 32GB per
clustered system (two-way clustered)
16GB per dual controller, up to 64GB per
clustered system (four clusters)
Integrated Features
FlashCopy (64 images per system),
Internal virtualization, Thin provisioning,
Data Migration
Internal virtualization, Thin Provisioning,
Data Migration, System Clustering
FlashCopy (4,096 images), Internal
virtualization, Thin provisioning, Data
Migration, Easy Tier, System Clustering
Optional Features
FlashCopy (2040 images) Remote
Mirroring, Easy Tier, Turbo Performance
FlashCopy (4,096 images) Easy Tier,
Remote Mirroring, External Virtualization
Remote Mirroring, Real Time Compression,
External Virtualization
External
Virtualization
No
Yes, Optional
Yes, Optional
Unified Support
No
No
NAS connectivity with Storwize V7000
Unified; IBM Active Cloud Engine integrated
*The best product to offer in any situation will vary depending on many factors, including the installed storage and competition
(see Storage Sales Guidance). Note that one advantage of these systems is their ability to scale up and out so they can satisfy
both larger initial requirements and also growth over time without needing to change from one to another.
21
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 22. Messaging Summary: Smarter Storage
Data Intensive Business
Solutions
Increase efficiency, flexibility, and scalability
with a virtualized cloud infrastructure
•Automatically provision block storage in the
cloud with SmartCloud Storage Access for XIV
and Storwize
•Improve XIV data protection in the cloud by
coordinating snapshots across XIV systems
with Hyper-Scale Consistency
•XIV reduces storage costs with VMware space
reclamation support
•Reduce cost of cloud storage up to 50% with
IBM SmartCloud Virtual Storage Center’s
automated, cross-platform Tiered Storage
Optimizer
22
Start Quickly add Value
Start quickly and add value to improve the
economics of IT with the IBM Storwize
platform
•The Storwize V5000 provides a new
intermediate choice in the Storwize family like
Easy Tier and external virtualization
•IP Replication on the Storwize platform
increases availability while cutting costs
•Storwize platform Software Defined Storage
includes Bridgeworks SANSlide network
optimization for remote mirroring
•IBM Storwize platform now supports twice the
amount of flash storage with larger 800GB
SSD drives
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 23. Trend tecnologici a confronto: data center
Negli ultimi 10 anni…
CPU: Prestazioni migliorate circa 8-10x
DRAM: Prestazioni migliorate circa 7-9x
Network: Prestazioni migliorate circa 100x
Hard Disk: Prestazioni migliorate
SOLO 1.2X
Al crescente divario tra le tecnologie si aggiungono la
costante crescita del volume dati da gestire e le esigenze
di business che richiedono velocità di reazione sempre
maggiori.
Fonte: Elaborazione IBM da varie analisi di mercato
23
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 24. IBM FlashSystem in sintesi
Prestazioni estreme
utilizzabile per velocizzare servizi applicativi aziendali
critici ed indirizzare facilmente la crescita dei servizi
MicroLatency™
consente un accesso veloce e consistente ai dati
aziendali più importanti
Efficienza Macro
soluzione ad alta efficienza che consente di consolidare
carichi applicativi, rilasciare più velocemente nuovi servizi
e ridurre i consumi energetici e di spazio
Affidabilità di classe Enterprise
progettazione con caratteristiche di affidabilità di livello
enterprise brevettate
24
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 25. Latenza: ma quanto mi costa?
1 SECONDO
RITARDO
CARICAMENTO=
PAGINA
7%
11%
16%
PERDITA
ACQUISTI
MINORI VISITE
MINORE
SODDISFAZIONE
DEI CLIENTI
In termini monetari se il sito genera in media 100.000 €
al giorno la perdita annua può arrivare a 2,5 M€
Fonte: Studio Aberdeen Group: “The Performance of Web Applications – Customers are Won or Lost in One Second” – November 2008
25
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 26. Comparison of Flash Storage with other technologies
€ / TB
Capacity
GB
€ / K IO/s
Performance
IO/s
1.000
1.000
~70
14.000
600
2.500
~200
7.000
64
1.000
~500
200
PC SSD
250
1.000
~5.000
50
Ent.SSD
400
35.000
~20.000
750
PCI Flash
2.000
15.000
~400.000
750
Ext. Flash
20.000
15.000
~400.000
750
SATA
FC HDD
USB Stick
26
Source: IBM FlashSystems and IBM Power Systems for SAP landscapes - ISICC
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 27. IBM FlashSystem Family
SLC Flash
eMLC Flash
Model
710
720
810
820
M/T
9830-AS1
9831-AS2
9830-AE1
9831-AE2
Power
280W
350W
350W
300W
Usable Capacity
1-5 TBu
5 or 10 TBu (R5)
6 or 12 TBu (R0)
2-10 TBu
10 or 20 TBu (R5)
12 or 24 TBu (R0)
Latency (R/W)
90/25 microsec
90/25 microsec
110/25 microsec
110/25 microsec
IOPS
450K
500K
400K
450K
Bandwidth
4GB/s
5GB/s
4GB/s
4GB/s
Interfaces
4x 8Gb FC or 4x 40Gb IB
4x 8Gb FC or 4x 40Gb IB
Sample list price
range (EUR) (*)
51K-154K
172K-322K
52K-154K
172K-322K
Data Protection
VSR™
2D Flash RAID™
(inc. VSR™)
VSR™
2D Flash RAID™
(inc. VSR™)
(*) Sample configurations just for positioning purposes – eConfig available for specific configurations
27
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 28. IBM FlashSystem: aree applicative e settori di industria
OLTP Databases
Financial
eCommerce
Analytical Apps/OLAP
Computational Applications
High Performance Computing
Telecom
Virtual Infrastructures
Cloud-Scale Infrastructures
Use Case
28
Government
Industry Vertical
Interviste clienti su YouTube: http://www.youtube.com/watch?v=AxeNyssFPhs
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 29. Potrebbe indicare le aree applicative dove è più evidente un calo
prestazionale oppure necessario incrementare le performance?
29
Fonte: IDC Web Survey 2013
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
- 30. IBM FlashSystem: come viene utilizzato oggi
Tiering
automatico
Affiancamento
Posizionamento
manuale
30
• Ideale per clienti V7000 o SVC
• Licenza standard Easy Tier
• Trasparenza applicativa
• SVC/V7000 vdisk Mirroring
• Application/OS Mirroring (ASM, LVM, etc)
• Hot Tables, Indexes, Temp, Undo, Logs
• LUN più attive
• Applicazioni più importanti
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 31. Esempi: integrazione IBM FlashSystem in ambiente SAP
Ambiente SAP di produzione
ERP
All-flash pool
SCM
SRM
Easy Tier pool
CRM
BW
Storage SAP organizzato
in pool con livelli di
servizio differenziati
HDD only pool
SAP test, sviluppo e pre-produzione
Virtualizzazione con SVC o V7000
IBM FlashSystem
31
IBM Storwize
V7000/V5000 (new)
ERP
SCM
…
…
…
Opportunità di utilizzo funzionalità
di efficienza: per esempio Easy Tier
automatico, «turbo compression»
(funzionalità real time data
compression migliorata), etc.
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano
© 2013 IBM Corporation
- 32. 32
© 2013 IBM Corporation
Museo Nazionale del Risorgimento Italiano – Palazzo Carignano