Future work Clinical Partners Meeting        20/03/2012Trinity College, Cambridge
Output Capabilities from PneumaScan™               Standard Spirometric Loops and               Values                    ...
PneumaCare LimitedPresent products on the market   PneumaScan™ Lung Function Assessment    DeviceProducts in test phase...
The Future – 2012• Age and “shape” appropriate grids• Improved tracking• Movement recognition• Real Time Monitor          ...
PneumaScan™Clinical Utilisation / Studies / Trials  Established Populations        COPD        Asthma        Cystic Fib...
Total Patient Population     Home                          Critical Care     Care                          Monitoring     ...
“Reverse Engineering” • Rehabilitation in COPD or thoracic   surgery • Inhaler technique • Feedback and incentives in   Di...
New analysis toolsFourier Transformation• Transforms one complex-valued function of a real  variable into another.• In sig...
Fourier Plots – Tidal Breathing             N= 50      Mean Correlation = 0.97            SD = 0.03
10
Afternoon - Workshops     – Gp A - Paediatricians     – Gp B - Surgical, Adult, Physiologists        • Facilitators       ...
Reconstruction
Upcoming SlideShare
Loading in …5
×

Future directions

395 views
374 views

Published on

Clinical Partner Meeting - 20/03/2012 - Trinity College, Cambridge

Dr Richard Iles - Consultant Respiratory Paediatrician - Addenbrooke's Hospital, Cambridge University Health Partners, Cambridge, UK

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
395
On SlideShare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Future directions

  1. 1. Future work Clinical Partners Meeting 20/03/2012Trinity College, Cambridge
  2. 2. Output Capabilities from PneumaScan™ Standard Spirometric Loops and Values 3 Dimensional Regional Analysis Output Configurations
  3. 3. PneumaCare LimitedPresent products on the market  PneumaScan™ Lung Function Assessment DeviceProducts in test phase  PneumaScan™ 3 Dimensional Analysis application  PneumaScan™ Real-Time Data acquisition module  PneumaScan™ Tracker Tool
  4. 4. The Future – 2012• Age and “shape” appropriate grids• Improved tracking• Movement recognition• Real Time Monitor 4
  5. 5. PneumaScan™Clinical Utilisation / Studies / Trials Established Populations  COPD  Asthma  Cystic Fibrosis  Thoracic  Neuromuscular  ICU New Patient Populations  Paediatric / Neonates  Elderly  Animal respiratory function  Home and Primary Care
  6. 6. Total Patient Population Home Critical Care Care Monitoring Neonatal Non-invasive Monitoring AssessmentsAdvanceddiagnostics Screening and Clinical Spirometry
  7. 7. “Reverse Engineering” • Rehabilitation in COPD or thoracic surgery • Inhaler technique • Feedback and incentives in Disordered Breathing 7
  8. 8. New analysis toolsFourier Transformation• Transforms one complex-valued function of a real variable into another.• In signal processing, the domain of the original function is typically time and is accordingly called the time domain.• The new function is frequency,• It describes which frequencies are present in the original function.• This is analogous to describing a chord of music in terms of the notes being played.• Fourier transform decomposes a function into oscillatory functions.
  9. 9. Fourier Plots – Tidal Breathing N= 50 Mean Correlation = 0.97 SD = 0.03
  10. 10. 10
  11. 11. Afternoon - Workshops – Gp A - Paediatricians – Gp B - Surgical, Adult, Physiologists • Facilitators • Research Adviser, Dr Simon Crick- Research Adviser, NIHR RDS for the East of England • Dinner – 7.30 - Browns 11
  12. 12. Reconstruction

×