Your SlideShare is downloading. ×
Team 2  mep presentation
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Saving this for later?

Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime - even offline.

Text the download link to your phone

Standard text messaging rates apply

Team 2 mep presentation

1,419
views

Published on

Published in: Business

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
1,419
On Slideshare
0
From Embeds
0
Number of Embeds
4
Actions
Shares
0
Downloads
13
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Jurijs Pavlovics Michael Ward Tim Corrighan _BIMCampus Revit 2014 Autumn 2013 MechanicalElectrical+Plumbing
  • 2. Introduction Brief Our team has been appointed to design a new office specifically tailored to legal firms and legal training. The building must incorporate space for multiple companies. Schedule of Accommodation: Office spaces (both open plan and cellular) Meeting/board rooms (varying sizes for specific uses, eg. 1 to 1, groups, etc.) Achieve storage room General storage rooms Moot court (legal training court) Break-out spaces throughout the building Kitchenette/coffee points Toilets (male,female, accessible WC’s, shower room, etc.) Accessible lift Cleaners store Central reception with guest waiting area MechanicalElectrical+Plumbing
  • 3. Site Proposed Site The proposed site is located on the North bank of the River Tyne, Newcastle upon Tyne. 57 Quayside Newcastle upon Tyne NE1 2BJ Currently housing a ‘Pocket Park’, an initiative promoted by NE1 MechanicalElectrical+Plumbing
  • 4. Site Constraints Site Boundaries The site is restricted on two sides by neighbouring buildings: Flynn’s Bar Law Building To the front, the site is restricted by the street front and public footpath To the rear, the site is slight more open with room for car parking All buildings are limited to roughly the same height and number of levels Observations Busy street to the South Access needed to property along the East boundary Access to car park from Broad Chare to the North East MechanicalElectrical+Plumbing
  • 5. Inspiration Presidents Stone + Brick Facades Quayside History Glass with hard materials Infill Architecture Modern Architecture sitting with Classical MechanicalElectrical+Plumbing
  • 6. Using the 3D City Model City Model Throughout this project and the last we have used a 3D city model of Newcastle to create the context for our Revit model. Used to better understand the site boundaries. We have used the 3D city model to create more professional external renders. The 3D model was used to align the point cloud data to one of the neighbouring buildings so a Revit model for these buildings could be modelled in place. MechanicalElectrical+Plumbing
  • 7. Data Acquisition Laser Scanning Tutorial in laser scanning with Paul from Leica Geosystems. Scanned the full site from several different locations We headed straight back to the computer suit to load the point cloud into Revit MechanicalElectrical+Plumbing
  • 8. Laser Scanning and Modelling from the Point Cloud Data Modelling from Point Cloud Data The point cloud data was opened in a new revit project and was used to begin building a model of the adjoining buildings to the site. Using walls, extrusions and windows we created the facades of the buildings. We created custom texture to apply to these surfaces. We then added roofs and further details to complete the context models. We worked individually on each of the buildings and the models were linked together before being imported and aligned to the site model. MechanicalElectrical+Plumbing
  • 9. DN By Department Legend Lift Offices Private Public WC Drawn Dwg. No. Scale at A1 Project No. Drawing Project Status Rev. Date this drawing is copyright - check all dimensions on site - inform architect / so of any discrepancies - work to figured dimensions only - do not scale Rev. Amendment Date Checked1 : 100 1234 A(00)GAP900 MW Departmental Plans 1234 - BCT2 - 57 Quayside Preliminary 09/11/13Checker 1 : 100 Departmental Level 00 1 1 : 100 Departmental Level 0 2 1 : 100 Departmental Level 1 3 1 : 100 Departmental Level 2 4 1 : 100 Departmental Level 3 5 The Design MechanicalElectrical+Plumbing
  • 10. Architectural Model Modelling in Revit We all began modelling the architecture model to create a com- prehensive mass made up of architectural elements: Walls (with materials) Floors Doors Windows and other glazing This is the base for the BIM MechanicalElectrical+Plumbing
  • 11. Structural Model Structural Grid 8x5 grid Horizontal Spacing - 3000/2000/4200/2000/3000 Vertical Spacing - 4000/2000/2000/6000/6000/5000/2500 Base of steel frame Primary Structure Steel Frame In-situe cast concrete floor Concrete pile foundations MechanicalElectrical+Plumbing
  • 12. MEP Model Lighting 150mm alound in ceiling void for recessed lighting Whitecroft Softlighter - 500 lux Spaced 2.4 m Ventilation and Heating and Cooling Duct work - rectangular 400x250 - circular 250 diameter/150 diameter Extract Grill Daikin FXFQ-M-12-36-MBH Each unit 2.1kW cooling Open plan office - 70-100W/m2 . FCU’s between 40-50 m2 MechanicalElectrical+Plumbing
  • 13. What is Next? Navisworks We will then import a central model into Autodesk’s Navisworks. Here we will run a series of clash detections between the architectural and structural models, architecture and MEP and structure with MEP. In Navisworks we will also create a series of construction animations and renders using the cloud. We welcome any questions? MechanicalElectrical+Plumbing