The advantages of the NexION 300D ICP-MS for the determination of titanium in serum

414
views

Published on

PerkinElmer describes a method to shift the Ti ions away from the interferences using Reaction mode with ammonia as the reaction gas to determine the concentration of Ti in serum. 011159_01

PerkinElmer describes a method to shift the Ti ions away from the interferences using Reaction mode with ammonia as the reaction gas to determine the concentration of Ti in serum. 011159_01

Published in: Health & Medicine

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
414
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
4
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. A P P L I C A T I O N B R I E F ICP-Mass Spectrometry Introduction Titanium (Ti) is commonly used in metallic hip replacement joints. Owing to wear and tear or different types of electrochemical processes that could take place in the body, there is a serious potential of leakage of Ti into the surrounding tissues. As such, it is important to monitor the Ti serum levels in patients that have undergone or are due to undergo a hip replacement surgery. The analysis of Ti in serum by inductively coupled plasma mass spectrometry (ICP-MS) faces many challenges due to significant spectroscopic interferences from Ca on the major isotope of Ti (m/z 48) and other molecular ions such as PO+ , SO+ , CO2 + , ArC+ and NO2 + . The PerkinElmer NexION® 300D ICP-MS is a robust, highly innovative cell-based system benefitting from three quadrupoles with the middle one acting as a universal cell. This cell can be used both as a collision cell using inert gases, such as He, and as a true dynamic reaction cell with the benefits of using the most appropriate reactive gas for the efficient targeting of any spectral interference. In this work, we describe a method to shift the Ti ions away from the interferences using Reaction mode with ammonia as the reaction gas to determine the concentration of Ti in serum. The Advantages of the NexION 300D ICP-MS for the Determination of Titanium in Serum Authors: Fadi Abou-Shakra David Price PerkinElmer, Inc. Shelton, CT
  • 2. For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs Copyright ©2013, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 011159_01 PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602 www.perkinelmer.com Analytical methodology Figure 1 shows a scan for 10 ppb Ti in Reaction mode (NH3 gas flow 0.9 mL/min, rpq 0.2) at m/z 129-134. The m/z of the observed peak suggest that the Ti complex observed is TiNH(NH3)4 , as evidenced by the peaks reflecting the Ti isotopic abundance. The formation of this complex was stable and reproducible. Figure 2 shows a calibration curve for Ti at mass 131. Although Xe+ has an isotope at m/z 131, it will not interfere with the Ti measurements since Xe reacts rapidly with NH3: Xe+ + NH3 → Xe + NH3 + Rate Constant: ≈10-10 Using matrix-matched calibration, Ti was measured in a Seronorm™ Trace Elements Serum L-1 reference material (LOT0903106) diluted 10x with 0.1% HNO3. The results obtained (10.6 ± 0.3 ng/mL) compared favorably with the recommended value for Ti in this sample (11.2 ng/mL). In order to gauge the detection capability of the method, 10 repeat analyses of a blank containing 10 ppm Ca (in order to simulate the Ca levels in 10x diluted serum) were performed. The observed concentration in the matrix was 0.031 ± 0.00122 ng/mL. This data suggests a detection limit (3 sigma) of 0.004 ng/mL in solution (0.04 ng/mL in serum) and a limit of quantification (10 sigma) of 0.0122 ng/mL in solution (0.12 ng/mL in serum). Summary This application brief highlights the potential of the NexION 300D ICP-MS for the analysis of Ti in serum. Using NH3 in Reaction mode, we successfully overcame the variety of interferences from serum on Ti. As a result, we were able to determine the levels of Ti in serum both accurately and reproducibly. Figure 1. Spectrum for 10 ppb Ti in Reaction mode. Figure 2. Calibration for Ti in Reaction mode.

×