Your SlideShare is downloading. ×
Standard spaside instruction sheet
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Standard spaside instruction sheet

106

Published on

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
106
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
1
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Economy Mode: Press this key to turn the Economy mode On/Off. The Economy Mode (Ec1) will maintain the water temperature at 20F below the set point until manually removed from this mode. This mode is recommended for users who occasionally use their spa with a minimal heat-up time required. The Economy Icon will appear while the Economy Mode is active. Freeze Protection: If the spa water temperature drops below 59BF the “Smart Winter Mode” will be activated for a period of 24-hours.If the pump has not been activated in the last 2-hours it will be turned for a period of 1-minute. This frequency will decrease as the temperature drops. If the spa water temperature drops to 49BF the pump and heater will be activated until the spa water temperature reaches 50BF. While in this second mode of freeze protection, control over the spa will be disabled until the water has heated sufficiently. The Filtration indicator will be illuminated while in this mode of operation.Default System Operation: When power is applied, or there is a temporary High Temperature: If the spa water temperature exceeds 115BF at the high-limitloss of power, the system will initiate its default programming. The filter cycle will begin sensor 3 flashing dots will appear below the temperature display and the heater will be24-hours after the system has been powered up. The filtration cycle will be active for 1- turned off. During this time all other outputs (pump, light etc.) will continue to operate. Ifhour and will repeat every 24-hours. The temperature will be maintained at 95BF. the spa water temperature exceeds 122BF at the high-limit sensor the heater and all outputs will be disabled. Once the spa water has cooled it will be necessary to cycle power to the spa off then on again to reset the system for normal use. Pump 1 Key: Press this key once to turn Pump 1 on. A second press willturn it off. For dual speed pump operation; Press this key once to turn Pump 1 onto Low Error Identification & Servicespeed, press this key a second time to turn Pump 1 onto High speed, a third press willturn the pump off. A built-in timer will shut the pump off after 20 minutes of operationunless done so manually. The Pump 1 Icon will appear on the LCD while the pump isrunning in High speed and flash while it is in Low speed. If the filter icon appears, afiltration cycle has begun and you will not be able to turn the pump off. Pump 2 Key: Press this key once to turn Pump 2 on. A second press will If 3 flashing dots appear below the temperature display an error and a needturn it off. For dual speed pump operation; Press this key once to turn Pump 2 onto Low for service has occurred. (Contact Your Local Dealer for Service)speed, press this key a second time to turn Pump 2 onto High speed, a third press willturn the pump off. A built-in timer will shut the pump off after 20 minutes of operationunless done so manually. The Pump 2 Icon will appear while the pump is running in Highspeed and flash while it is in Low speed. Accessory/List Key: Press this key once to turn blower onto Highspeed, a second press will turn the blower onto Low speed and a third press will turn the If the actual spa water temperature greatly differs from the displayedblower off. A built-in timer will shut the pump off after 20 minutes of operation unless temperature or the display reads a constant 33BF, a temperature sensordone so manually. The Accessory Icon will appear while the blower is running in High error and a need for service has occurred. (Contact Your Local Dealer forspeed and flash while it is in Low speed. Service) Light/Enter Key: Press this key to turn the light onto its highestintensity, a second press will turn the light onto low and a third press will turn it off. Ifequipped with Fiber Optic: Press this key once to show “L1”. Use the Up arrow key toturn the light onto High, Medium, Low and Off. Press the light key a second time, “F1”will appear. Use the Up arrow key to turn the Fiber Optic wheel and light on, Fiber Opticwheel off with light on and both Off. The light will automatically shut off after 2 hours. TheLight Icon will appear while the light is on. If 3 flashing below the temperature display and the temperature displayed is 115BF ro higher, and over temperature condition and a need for service has occurred. (Contact Your Local Dealer for Service) Temperature Set Keys: Press the Up arrow key to NOTE: If you notice the pump coming on for seemingly no reason throughoutincrease the desired temperature. Press the Down arrow key to decrease the the day, the system may be in “Smart Winter Mode”. If you cannot control sometemperature. The temperature can be adjusted in 1BF increments from 59BF to 104BF functions of the spa be sure to check to see if the Filtration indicator is(5BC to 40BC). The new setting will remain on the display for 5 seconds as a illuminated. The spa may be in the midst of a filtration cycle. Freeze Protectionconfirmation. During this time the Set Point icon will be appear to let you know this is the and Over temperature condition will also limit or disable spa functions.desired and not the actual temperature. After 5 seconds the display will return to thecurrent temperature reading. When the temperature drops to 1BF below the settemperature, the heater will be turned on until the temperature is 1BF above the settemperature. The heater icon will appear while the heater is on and flash when there is acall for heat and the heater has not yet been activated. Programming Parameters: This key is used to program the filtercycle. Follow these procedures to set each parameter: (1) Press the Program Key; thedisplay shows the current duration of the filter cycle F followed by 0 to 12. (2) Once theparameter is displayed, use the Up/Down arrows to adjust the setting. The filter cycle isactivated every 12-hours. The duration can be set from 0 (never on) to 12 (always on).(3) Press the Program key to begin a filter cycle. The filter icon will appear while the filter http://www.MyPoolSpas.comcycle is operating. Wholesale Pool and Spa Parts 920-925-3094 85-0040 Rev.7 09.07.01

×