00B-1   Rev.3   11/04
s
NOTES                                                                                ELECTRICAL CONNECTIONS
Use this section to jot down any information you may need at a later date.
                                                                                    If your system was configured to include a 120VAC power cord, ensure that the proper
                                                                                    receptacle has been installed (a dedicated circuit is required). DO NOT under any circumstances

Dealer:                                           Date of Install:
                                                                                    modify a 20 Amp plug to fit into a 15 Amp receptacle or use an extension cord. Doing so will
                                                                                    create hazardous conditions and/or void the warranty.


Contact:                                                      Phone:                 OPTION 1 Units with 15A GFCI Plug Connection
Address:                                                                            15AMP CORDEND GFCI


City:                                                         State:         Zip:
                                                                                                                      DEDICATED
                                                                                                                   15A / 120V OUTLET
                                                                                      MAIN BREAKER PANEL



                                                                                                                                                          PORTABLE SPA




Notes:



                                                                                    This illustration depicts a typical 15 AMP, cord-end GFCI installation.
                                                                                    (The spa must be installed on a dedicated circuit.)




                                                                                                                                 DO NOT
                                                                                                                                  USE AN
                                                                                                                                EXTENSION
                                                                                                             15 AMP                CORD          20 AMP
                                                                                                           RECEPTACLE                          RECEPTACLE




                                               17                                                                                      2
ELECTRICAL CONNECTIONS
 OPTION 2 GFCI Installed in Main Service Panel
     20-60AMP
                        If the manufacturer of your homes main breaker panel makes a GFCI breaker, you
                        may be able to add it to an open slot in the panel.
    HARDWIRED
   MAIN BREAKER PANEL

                                   INLINE SPA DISCONNECT



                                                                                   PORTABLE SPA




       LINE 1
        N
       LINE 2




                            REFER TO GFCI WIRING DETAIL

Power from GFCI breaker installed into main service panel to a service
disconnect within line-of-site of the spa.



 OPTION 2a                 Subpanel GFCI Installed
20-60AMP HARDWIRED

  MAIN BREAKER PANEL
                                    GFCI DISCONNECT

                                                                    INLINE SPA DISCONNECT

                                                                                            TO PORTABLE SPA
                                        LINE 1


                                                     LINE 2
                                                 N




                                                                  REFER TO GFCI WIRING DETAIL

Power from main service panel to a GFCI subpanel within line-of-site of the
spa. (Note: Most local codes will allow a GFCI subpanel to be a disconnect. If
this is not the case in your installation, a disconnect must be provided.)



                                                              3                                               16
SYSTEM DATA LABEL
                                                                                               ELECTRICAL CONNECTIONS
The system data label is located on the control box. This label is very important and

                                                                                                 OPTION 3
contains information you will need to establish your electrical service. The voltage and
amperage ratings are shown on the bottom of the label. Product, Model, Serial and                                       Systems with GFCI Included
Code numbers are also shown on the label.
                                                                                                                        Your system may have an integrated GFCI located on the left side of the control
                                                                                               BUILT-IN SYSTEM GFCI box as shown below. If a GFCI is present there is NO need for additional GFCI
Note: This information will be necessary if you should ever have to request warranty                                    protection illustrated in options 2 & 2a.
      or any other type of service.                                                               MAIN BREAKER PANEL                                                   ON


                                                                                                                                                                       RESET
                                                                                                                                                                                                    Located on left side of control box.
                                                                                                                               INLINE SPA DISCONNECT
                                                                                                                                                                       TEST




                                                                                                                                                                      OFF




                                                                                                                                                                    PORTABLE SPA CONTROL w/BUILT-IN GFCI



                                                                                                                                                                                 Light


                                                                                                                                                                               POWER
                                                                                                                                                                               CONTROL
                                                                                                                                                                               SWITCH
                                                                                                                                                                               Refer to Operation                                Pump 1
                                                                                                                                                                               Manual for testing
                                                                                                                                                                               and operational
                                                                                                                                                                               procedures
                                                                                                                                                                                                                             *Pump 2


                                                                                                                                                                                                                                   Air


                                                                                                                                                                                                                                 Ozone


                                                                                                                                                                                                                             *Pump 3


                                                                                                                                                                                                                                 *Circ.


                                                                                                                                                                                                                                 *Aux.


                                                                                                                                                                                                                                 *Aux.

                                                                                                                                                                                                                                 *Optional


                                                                                                                                                                                                      HEATER
                                                                                                                                                                                                        ON




                                                                                                                                                                                                                   SOLID-STATE
                                                                                                                                                                                                               CONTROL SYSTEM




                      ORDER CODE:

                      MODEL:

                      SERIAL:                                                                  Power from main breaker panel to service disconnect within line-of-site of the
                                                                                               spa to portable spa control equipped with buit-in GFCI.
                      CODE:

                      VOLTS:                                                               N
                      AMPS:                                                                    IMPORTANT - The NEC and most local codes require that a “disconnect”
                      PRODUCT:                                                                 be installed within “line-of-site” of the spa.


                                                                                               ELECTRICAL INSTALLATION DETAILS
                                 REFER TO NEC FOR
                                  BREAKER SIZING

                                                                                               Refer to the System Data Label for equipment voltage and maximum amperage draws.

                                                                                               Install proper size Ground Fault Circuit Interrupter (GFCI) or circuit breaker, then proper sized
                                                                                               wiring and bonding wire. For Power conductor size, refer to the National Electric Code Table
                                                                                               310-16. For Ground conductor size, refer to the National Electric Code Table 250-122.

                                                                                               A bonding lug has been provided on the control box to allow connection to local ground points.
                                                                                               To reduce the risk of electrical shock, a solid copper bonding wire should be connected from this
                                                                                               lug to any metal ladders, water pipes or other metal object within 5 feet of the spa.


                                                                                           !   WARNING - BE SURE THAT YOUR POWER SUPPLY CIRCUIT CAN ADEQUATELY HANDLE
                                                                                               THE AMPERAGE YOU SELECT.

                                                                                               The control input power wiring may have been provided. Following NEC and local codes in effect
                                                                                               at the time of installation, connect (refer to wiring diagram located on the inside of control hinged
                                                                                               cover) the Black wire to input Line 1, Blue wire to input Line 2 (if applicable), White wire to
                                                                                               Neutral and the Green wire to ground.


                                           15                                                                                                       4
GFCI WIRING DETAIL                                                                                                  SPECIAL CONSIDERATIONS
When a GFCI circuit breaker is used in the installation of your spa, it is important that it has been               If your system is equipped with a pressure switch, the function of the pressure switch is to turn the heater off if the
properly installed. Often this component has been improperly installed causing the breaker to trip                  pump stops operating or if there is a restricted water flow (dirty filter, obstruction in the spa plumbing etc.).
the instant the system is turned on. Below is an illustration of a typical GFCI breaker installation.
                                                                                                                    The pressure switch has been preset at the factory to operate properly with your spas specific plumbing.
                                                                                                                    Adjustment or other service may be required if you observe a flow related problem (3 flashing dots on spaside
                                                                                                                    display). If adjustment is required, follow the next steps carefully.
WARNING: Refer to Circuit Breaker Manufacturers installation instructions.
This illustration is meant to be a guide for Field Technicians and is not                                           IMPORTANT: After any pressure switch adjustment, it is important to test the control by
intended to override or substitute the instructions supplied with the circuit                                       turning on the pump low speed and heater. While operating, unplug the pump, the
breaker.                                                                                                            heater must turn off. If the heater stays on, plug the pump back in and readjust the
                                                                                                                    pressure switch to achieve proper operation.


                                                                                                         LINE 1
                                                                                                         LINE 2     Adjustment
                                                                                                                    1) With power to system turned OFF, remove the wires from the pressure switch terminals
                                                                                                                       (secure wires safely to prevent any chance of electrical shock).

 LINE LUG #1                                    LINE LUG #2                                             INCOMING
                                                                                     NEUTRAL BUS BAR
                                                                                                                    2) Use temperature adjustment key to move “set point” temperature to its lowest setting.
                                                                                                         SERVICE
                                                                                                       CONDUCTORS   3) Turn power to the system ON and activate the low-speed pump.
                                                                                                          FROM
                                                      NEUTRAL PIGTAIL




                                                                                                          MAIN
                                                                                                                    4) Place an Ohmmeter across the pressure switch terminals to verify an OPEN circuit.
                   TEST
                                                                                                          PANEL
                     GFCI
                                                                                                                    5) Rotate the pressure switch adjustment screw counter-clockwise until the Ohmmeter indicates
                                                                                                                       a CLOSED circuit.

                 (Ground Fault Circuit Interrupter)
                                                                                                                    6) Turn pump OFF and verify that the pressure switch circuit is once again OPEN.
                 CIRCUIT BREAKER
                                                                                                         NEUTRAL    7) Turn power to the system OFF and reconnect pressure switch wires. Reapply power to the
                                                                                                         GROUND        system and operate the spa or hot tub as normal.



                     LOAD
                                                                            GROUND BUS BAR
                                                                                                                                         Adjustment Screw


                LINE 1                 LINE 2
                                                                                                                                     Calibration Scale (1lb.)        P1

                       NEUTRAL                        GROUND
                                                                                                                                                                     S2
                                                                                                                                                                     I 3




           TO SPA CONTROL SYSTEM
 LOAD NEUTRAL MUST BE CONNECTED
    DIRECTLY TO GFCI AS SHOWN

                                                                        5                                                                                                    14
NO THERAPY JET OPERATION                                                                     SYSTEM CONFIGURATION
Water Shut-Off Valves are Closed - Open Shut-Off valves.                                    Congratulations on your purchase of the Universal Series Control System.
Jets Not Properly Adjusted - Adjust Jets properly.                                          This series of controls has been developed to allow you complete flexibility during your
Diverter Valve Not Properly Adjusted - Adjust diverter valve properly.                      installation. This Control System is configured to allow you to choose the voltage for each circuit
Thermal Overload Tripping - Check for restricted flow of water.                             at the time of installation. We highly recommend that all component cords be replaced at the



                                                                                        !
                                                                                            time of installation.


  NO LIGHT OPERATION
                                                                                            The Universal conversion procedure MUST be accomplished PRIOR to connecting input
                                                                                            service wiring. This control has been shipped from the factory with ALL circuits wired for



                                                                                        !
                                                                                            120 VAC.
Light Bulb Defective - Replace bulb or contact your local dealer.
                                                                                            VERIFY YOUR COMPONENT VOLTAGE REQUIREMENTS: 120 VAC will not harm a 240 VAC
Reflector has Fallen Off - Replace deflector or contact your local dealer.                  component if operated temporarily. 240 VAC WILL harm a 120 VAC component almost
Light Not Plugged-In - Plug in the Light.                                                   immediately. This is the reason we ship all circuits in the 120 VAC configuration. We
                                                                                            cannot be held responsible for mis-wire related damage to components.

                                                                                            Note: To utilize the Universal circuitry (120/240VAC), incoming service must be 240V/4-Wire. W

  WATER LEAKS
                                                                                            We have made the conversion process simple and easy. After you have determined the
Spa Overfilled - Adjust water level.                                                        voltage of your components (pump(s), air blower, ozonator etc.), you are now ready to
Drain-Valve Left Open - Close drain valve.                                                  complete the conversion process. Color-Coded Neutral Wire connectors have been
Couplings or Unions Loose - Tighten or contact your local dealer.                           provided to easily distinguish the circuit to be converted. By simply moving a Neutral
Pump Seal Leaking - Contact your local dealer.                                              wire from the Neutral side of the conversion terminal block, clearly marked and
Plumbing / Connections Leaking - Contact your local dealer.                                 located inside the control enclosure, to the Line 2 side completes the circuit conversion.
Water Leaking from Spaside Control - Contact your local dealer.                             Follow the illustrations and step-by-step instructions.
Water in Air Blower Plumbing - Contact your local dealer.
                                                                                            Circuit Color Chart
                                                                                                 Red Connector = Pump 1                                                   Brown Connector = Circulation Pump

  NO HEAT
                                                                                                                                                                                            (Optional)
                                                                                                 Violet Connector = Pump 2 (Optional)
                                                                                                                                                                          Note: Ozonator Circuit 120V ONLY
                                                                                                 Blue Connector = Air Blower
Temperature Not Set Correctly - Adjust “Set Point” Temperature.

System Power Restriction - Depending on available power, the spa may have
interlocks in place to shut off the heater when the pumps are switched to high speed.       Step 1
                                                                                            Remove 2(ea) screws and open
                                                                                            front cover of enclosure. Locate

  HIGH HEAT
                                                                                            the conversion terminal block and
                                                                                            desired connector (using ‘Circuit
                                                                                            Color Chart” above). Carefully
Temperature Sensor Not in Dry-Well - Place sensor in dry-well.                              remove connector from the Neutral
Temperature Set Too High - Adjust “Set Point” Temperature.                                  side.
High Ambient Temperature - Remove spa cover.




                                                                                                                                                                  s)
                                                                                                                                                   ral
                                                                                                                                                                     nt
                                                                                                                                                                pone
                                                                                                                                            Neut
                                                                                                                                                            Com
  GFCI TRIPS IMMEDIATELY

                                                                                                                                                       (120V
                                                                                                                                                     nts)
                                                                                                                                            2
                                                                                                                                                pone
                                                                                                                                       Line
                                                                                        !                                                   Com
                                                                                                                                          (240
                                                                                                                                               V
For correct GFCI breaker wiring, refer to page 5 for details.                               If you have a 3-wire/240V connected
                                                                                            system, you will not have the Universal

                                          13                                                                                                                          6
                                                                                            option
CONNECTION                                                                                        CONNECTION
Below is an illustration showing our exclusive colored receptacles, located on the right side of   Spaside Control: If equipped, install the Spaside Control per the manufacturers
the control box. Use this illustration when connecting spa components.                             instructions. Once installed, connect the Spaside Control plug into the receptacle provided on the
                                                                                                   side of the control box (as shown in the illustration below). If the Spaside Control includes a


                        Receptacle Color Chart
                                                                                                   thermostat, installed the temperature probe into the dry-well of the spa.




                  RED                                                      RED
                  Pump 1 / 2-Speed                            Pump 1 / 2-Speed


                  PINK                                                 BROWN
                  Pump 2 / 1 or 2-Speed                       Pump 2 / 2-Speed


                  WHITE                                                    PINK
                  Air Blower                             Pump 1 or 2 / 1-Speed


                  YELLOW                                               VIOLET
                  Ozonator                                            Air Blower


                  GREEN                                               YELLOW
                  “Hot” Accessory                                       Ozonator


                  RED 3-Pin                                    LIGHT VIOLET
                  Circulation Pump                          Switched Accessory                     Spa Light: Using a suitable 2 ½ “ diameter hole-saw, cut a hole in the spa wall.
                                                                                                   Cut from inside the spa wall toward the outside to prevent splintering the inner surface.
                  WHITE 2-Pin                                             BLUE                     Remove any insulation material from around the hole (at least ½ “) at the outside spa wall.
                  12V Light                                    Circulation Pump                    Install the gasket onto the light body and install the light into the hole. Take care not to over
                                                                                                   tighten the nut securing the light body. (Silicone sealant may be used in place of the gasket. Allow
                                                                        WHITE
                                                                                                   adequate time for sealant to cure before filling the spa.)

                                                                   12V Light or
                                                               Firemans Switch
Assure that all plugs and receptacles are fully                                                    Note: It is recommended that the water level be stopped just above the level of the spa light until a
connected. A loose connection can cause damage to                                                  thorough inspection for leaks can be completed.
the system.

Note: We utilizes the BLACK wire for                                  ORANGE
High-Speed and the RED wire for Low-Speed in                         Fiber Optic
Two-Speed Pump Circuits. Keep this in mind

                                                                        GREEN
when connecting a Two-Speed pump that has not
been purchased with the system.
                                                                “Hot” Accessory

                                                                                                                                Light Bulb                                                  Light Body

                                                                                                                                                    Spa Wall
                                                                                                                                                                                        Gasket
                                                9                                                                                                          10

More Related Content

What's hot

Advanced motion controls se30a8
Advanced motion controls se30a8Advanced motion controls se30a8
Advanced motion controls se30a8Electromate
 
Advanced motion controls se10a20
Advanced motion controls se10a20Advanced motion controls se10a20
Advanced motion controls se10a20Electromate
 
Reducing Electrical Control Panel Size
Reducing Electrical Control Panel SizeReducing Electrical Control Panel Size
Reducing Electrical Control Panel SizeCMA/Flodyne/Hydradyne
 
Leviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guideLeviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guideAlarm Grid
 
ASL Intercom PS19A
ASL Intercom PS19AASL Intercom PS19A
ASL Intercom PS19AAV ProfShop
 
Honeywell 5843-install-guide
Honeywell 5843-install-guideHoneywell 5843-install-guide
Honeywell 5843-install-guideAlarm Grid
 
Advanced motion controls_azb10a4ic
Advanced motion controls_azb10a4icAdvanced motion controls_azb10a4ic
Advanced motion controls_azb10a4icElectromate
 

What's hot (10)

Advanced motion controls se30a8
Advanced motion controls se30a8Advanced motion controls se30a8
Advanced motion controls se30a8
 
Advanced motion controls se10a20
Advanced motion controls se10a20Advanced motion controls se10a20
Advanced motion controls se10a20
 
Reducing Electrical Control Panel Size
Reducing Electrical Control Panel SizeReducing Electrical Control Panel Size
Reducing Electrical Control Panel Size
 
Leviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guideLeviton vrf01 1 lz product manual and setup guide
Leviton vrf01 1 lz product manual and setup guide
 
ASL Intercom PS19A
ASL Intercom PS19AASL Intercom PS19A
ASL Intercom PS19A
 
Honeywell 5843-install-guide
Honeywell 5843-install-guideHoneywell 5843-install-guide
Honeywell 5843-install-guide
 
A05 0180
A05 0180A05 0180
A05 0180
 
Profx16 22 om
Profx16 22 omProfx16 22 om
Profx16 22 om
 
Advanced motion controls_azb10a4ic
Advanced motion controls_azb10a4icAdvanced motion controls_azb10a4ic
Advanced motion controls_azb10a4ic
 
XUR 100
XUR 100XUR 100
XUR 100
 

Similar to 85 0100 b-1-rev 3_generic air installation

Advanced motion controls 120a10b
Advanced motion controls 120a10bAdvanced motion controls 120a10b
Advanced motion controls 120a10bElectromate
 
Advanced motion controls 120a10b 24
Advanced motion controls 120a10b 24Advanced motion controls 120a10b 24
Advanced motion controls 120a10b 24Electromate
 
Honeywell gsmx-power-output-worksheet
Honeywell gsmx-power-output-worksheetHoneywell gsmx-power-output-worksheet
Honeywell gsmx-power-output-worksheetAlarm Grid
 
Advanced motion controls 120a10b 24nh
Advanced motion controls 120a10b 24nhAdvanced motion controls 120a10b 24nh
Advanced motion controls 120a10b 24nhElectromate
 
Advanced motion controls 120a10b nh
Advanced motion controls 120a10b nhAdvanced motion controls 120a10b nh
Advanced motion controls 120a10b nhElectromate
 
Arbrux Troubleshooting Guide
Arbrux Troubleshooting GuideArbrux Troubleshooting Guide
Arbrux Troubleshooting GuideArbrux Limited
 
Original Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power Integration
Original Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power IntegrationOriginal Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power Integration
Original Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power IntegrationAUTHELECTRONIC
 
Original Power Supply IC LNK616PG LNK616P LNK616 DIP-7 New
Original Power Supply IC LNK616PG LNK616P LNK616 DIP-7 NewOriginal Power Supply IC LNK616PG LNK616P LNK616 DIP-7 New
Original Power Supply IC LNK616PG LNK616P LNK616 DIP-7 NewAUTHELECTRONIC
 
Advanced motion controls zb6a6
Advanced motion controls zb6a6Advanced motion controls zb6a6
Advanced motion controls zb6a6Electromate
 
Honeywell 5802mn2-install-guide
Honeywell 5802mn2-install-guideHoneywell 5802mn2-install-guide
Honeywell 5802mn2-install-guideAlarm Grid
 

Similar to 85 0100 b-1-rev 3_generic air installation (20)

85 0100 b-rev 3_univ air installation_web
85 0100 b-rev 3_univ air installation_web85 0100 b-rev 3_univ air installation_web
85 0100 b-rev 3_univ air installation_web
 
85 0135 b-installation manual_web
85 0135 b-installation manual_web85 0135 b-installation manual_web
85 0135 b-installation manual_web
 
85 0100 b-p-rev 1_air installation_web
85 0100 b-p-rev 1_air installation_web85 0100 b-p-rev 1_air installation_web
85 0100 b-p-rev 1_air installation_web
 
85 0100 b-p-rev 1_air installation_web
85 0100 b-p-rev 1_air installation_web85 0100 b-p-rev 1_air installation_web
85 0100 b-p-rev 1_air installation_web
 
Xd 8550-6000
Xd 8550-6000Xd 8550-6000
Xd 8550-6000
 
Advanced motion controls 120a10b
Advanced motion controls 120a10bAdvanced motion controls 120a10b
Advanced motion controls 120a10b
 
Advanced motion controls 120a10b 24
Advanced motion controls 120a10b 24Advanced motion controls 120a10b 24
Advanced motion controls 120a10b 24
 
Vip Er22a
Vip Er22aVip Er22a
Vip Er22a
 
Honeywell gsmx-power-output-worksheet
Honeywell gsmx-power-output-worksheetHoneywell gsmx-power-output-worksheet
Honeywell gsmx-power-output-worksheet
 
Advanced motion controls 120a10b 24nh
Advanced motion controls 120a10b 24nhAdvanced motion controls 120a10b 24nh
Advanced motion controls 120a10b 24nh
 
Advanced motion controls 120a10b nh
Advanced motion controls 120a10b nhAdvanced motion controls 120a10b nh
Advanced motion controls 120a10b nh
 
Arbrux Troubleshooting Guide
Arbrux Troubleshooting GuideArbrux Troubleshooting Guide
Arbrux Troubleshooting Guide
 
manual dimmer - Zipato
manual dimmer - Zipatomanual dimmer - Zipato
manual dimmer - Zipato
 
AN-9754
AN-9754AN-9754
AN-9754
 
Original Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power Integration
Original Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power IntegrationOriginal Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power Integration
Original Power Supply IC LNK626PG LNK626P LNK626 DIP-7 New Power Integration
 
Pdiusbd11
Pdiusbd11Pdiusbd11
Pdiusbd11
 
Original Power Supply IC LNK616PG LNK616P LNK616 DIP-7 New
Original Power Supply IC LNK616PG LNK616P LNK616 DIP-7 NewOriginal Power Supply IC LNK616PG LNK616P LNK616 DIP-7 New
Original Power Supply IC LNK616PG LNK616P LNK616 DIP-7 New
 
5808spec
5808spec5808spec
5808spec
 
Advanced motion controls zb6a6
Advanced motion controls zb6a6Advanced motion controls zb6a6
Advanced motion controls zb6a6
 
Honeywell 5802mn2-install-guide
Honeywell 5802mn2-install-guideHoneywell 5802mn2-install-guide
Honeywell 5802mn2-install-guide
 

More from Accurate Pool & Spa Services, llc

More from Accurate Pool & Spa Services, llc (20)

Ultimate spaside instruction sheet
Ultimate spaside instruction sheetUltimate spaside instruction sheet
Ultimate spaside instruction sheet
 
Standard spaside instruction sheet
Standard spaside instruction sheetStandard spaside instruction sheet
Standard spaside instruction sheet
 
Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2Ps 9704 manual-rev1_2
Ps 9704 manual-rev1_2
 
Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2Ps 7100 manual-rev1_2
Ps 7100 manual-rev1_2
 
Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2Ps 6500 manual-rev1_2
Ps 6500 manual-rev1_2
 
Hq label wd highlight
Hq label wd highlightHq label wd highlight
Hq label wd highlight
 
Eco 3 spaside instruction sheet
Eco 3 spaside instruction sheetEco 3 spaside instruction sheet
Eco 3 spaside instruction sheet
 
Eco 2 spaside instruction sheet
Eco 2 spaside instruction sheetEco 2 spaside instruction sheet
Eco 2 spaside instruction sheet
 
Eco 1 spaside instruction sheet
Eco 1 spaside instruction sheetEco 1 spaside instruction sheet
Eco 1 spaside instruction sheet
 
Eco 2 pcb revisions
Eco 2 pcb revisionsEco 2 pcb revisions
Eco 2 pcb revisions
 
Eco 1 programming
Eco 1 programmingEco 1 programming
Eco 1 programming
 
Deluxe spaside instruction sheet
Deluxe spaside instruction sheetDeluxe spaside instruction sheet
Deluxe spaside instruction sheet
 
Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07Cs9700 software upgrade notice 3 07
Cs9700 software upgrade notice 3 07
 
Cs9700 llp settings 3 07
Cs9700 llp settings 3 07Cs9700 llp settings 3 07
Cs9700 llp settings 3 07
 
Control cord colors
Control cord colorsControl cord colors
Control cord colors
 
850077 a outdoor operation
850077 a outdoor operation850077 a outdoor operation
850077 a outdoor operation
 
9400 9600 programming
9400 9600 programming9400 9600 programming
9400 9600 programming
 
9300 programming
9300 programming9300 programming
9300 programming
 
85 0138 infrared remote-web
85 0138 infrared remote-web85 0138 infrared remote-web
85 0138 infrared remote-web
 
85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web85 0137 rev 1-palm pilot programming_web
85 0137 rev 1-palm pilot programming_web
 

85 0100 b-1-rev 3_generic air installation

  • 1. 00B-1 Rev.3 11/04
  • 2. s
  • 3. NOTES ELECTRICAL CONNECTIONS Use this section to jot down any information you may need at a later date. If your system was configured to include a 120VAC power cord, ensure that the proper receptacle has been installed (a dedicated circuit is required). DO NOT under any circumstances Dealer: Date of Install: modify a 20 Amp plug to fit into a 15 Amp receptacle or use an extension cord. Doing so will create hazardous conditions and/or void the warranty. Contact: Phone: OPTION 1 Units with 15A GFCI Plug Connection Address: 15AMP CORDEND GFCI City: State: Zip: DEDICATED 15A / 120V OUTLET MAIN BREAKER PANEL PORTABLE SPA Notes: This illustration depicts a typical 15 AMP, cord-end GFCI installation. (The spa must be installed on a dedicated circuit.) DO NOT USE AN EXTENSION 15 AMP CORD 20 AMP RECEPTACLE RECEPTACLE 17 2
  • 4. ELECTRICAL CONNECTIONS OPTION 2 GFCI Installed in Main Service Panel 20-60AMP If the manufacturer of your homes main breaker panel makes a GFCI breaker, you may be able to add it to an open slot in the panel. HARDWIRED MAIN BREAKER PANEL INLINE SPA DISCONNECT PORTABLE SPA LINE 1 N LINE 2 REFER TO GFCI WIRING DETAIL Power from GFCI breaker installed into main service panel to a service disconnect within line-of-site of the spa. OPTION 2a Subpanel GFCI Installed 20-60AMP HARDWIRED MAIN BREAKER PANEL GFCI DISCONNECT INLINE SPA DISCONNECT TO PORTABLE SPA LINE 1 LINE 2 N REFER TO GFCI WIRING DETAIL Power from main service panel to a GFCI subpanel within line-of-site of the spa. (Note: Most local codes will allow a GFCI subpanel to be a disconnect. If this is not the case in your installation, a disconnect must be provided.) 3 16
  • 5. SYSTEM DATA LABEL ELECTRICAL CONNECTIONS The system data label is located on the control box. This label is very important and OPTION 3 contains information you will need to establish your electrical service. The voltage and amperage ratings are shown on the bottom of the label. Product, Model, Serial and Systems with GFCI Included Code numbers are also shown on the label. Your system may have an integrated GFCI located on the left side of the control BUILT-IN SYSTEM GFCI box as shown below. If a GFCI is present there is NO need for additional GFCI Note: This information will be necessary if you should ever have to request warranty protection illustrated in options 2 & 2a. or any other type of service. MAIN BREAKER PANEL ON RESET Located on left side of control box. INLINE SPA DISCONNECT TEST OFF PORTABLE SPA CONTROL w/BUILT-IN GFCI Light POWER CONTROL SWITCH Refer to Operation Pump 1 Manual for testing and operational procedures *Pump 2 Air Ozone *Pump 3 *Circ. *Aux. *Aux. *Optional HEATER ON SOLID-STATE CONTROL SYSTEM ORDER CODE: MODEL: SERIAL: Power from main breaker panel to service disconnect within line-of-site of the spa to portable spa control equipped with buit-in GFCI. CODE: VOLTS: N AMPS: IMPORTANT - The NEC and most local codes require that a “disconnect” PRODUCT: be installed within “line-of-site” of the spa. ELECTRICAL INSTALLATION DETAILS REFER TO NEC FOR BREAKER SIZING Refer to the System Data Label for equipment voltage and maximum amperage draws. Install proper size Ground Fault Circuit Interrupter (GFCI) or circuit breaker, then proper sized wiring and bonding wire. For Power conductor size, refer to the National Electric Code Table 310-16. For Ground conductor size, refer to the National Electric Code Table 250-122. A bonding lug has been provided on the control box to allow connection to local ground points. To reduce the risk of electrical shock, a solid copper bonding wire should be connected from this lug to any metal ladders, water pipes or other metal object within 5 feet of the spa. ! WARNING - BE SURE THAT YOUR POWER SUPPLY CIRCUIT CAN ADEQUATELY HANDLE THE AMPERAGE YOU SELECT. The control input power wiring may have been provided. Following NEC and local codes in effect at the time of installation, connect (refer to wiring diagram located on the inside of control hinged cover) the Black wire to input Line 1, Blue wire to input Line 2 (if applicable), White wire to Neutral and the Green wire to ground. 15 4
  • 6. GFCI WIRING DETAIL SPECIAL CONSIDERATIONS When a GFCI circuit breaker is used in the installation of your spa, it is important that it has been If your system is equipped with a pressure switch, the function of the pressure switch is to turn the heater off if the properly installed. Often this component has been improperly installed causing the breaker to trip pump stops operating or if there is a restricted water flow (dirty filter, obstruction in the spa plumbing etc.). the instant the system is turned on. Below is an illustration of a typical GFCI breaker installation. The pressure switch has been preset at the factory to operate properly with your spas specific plumbing. Adjustment or other service may be required if you observe a flow related problem (3 flashing dots on spaside display). If adjustment is required, follow the next steps carefully. WARNING: Refer to Circuit Breaker Manufacturers installation instructions. This illustration is meant to be a guide for Field Technicians and is not IMPORTANT: After any pressure switch adjustment, it is important to test the control by intended to override or substitute the instructions supplied with the circuit turning on the pump low speed and heater. While operating, unplug the pump, the breaker. heater must turn off. If the heater stays on, plug the pump back in and readjust the pressure switch to achieve proper operation. LINE 1 LINE 2 Adjustment 1) With power to system turned OFF, remove the wires from the pressure switch terminals (secure wires safely to prevent any chance of electrical shock). LINE LUG #1 LINE LUG #2 INCOMING NEUTRAL BUS BAR 2) Use temperature adjustment key to move “set point” temperature to its lowest setting. SERVICE CONDUCTORS 3) Turn power to the system ON and activate the low-speed pump. FROM NEUTRAL PIGTAIL MAIN 4) Place an Ohmmeter across the pressure switch terminals to verify an OPEN circuit. TEST PANEL GFCI 5) Rotate the pressure switch adjustment screw counter-clockwise until the Ohmmeter indicates a CLOSED circuit. (Ground Fault Circuit Interrupter) 6) Turn pump OFF and verify that the pressure switch circuit is once again OPEN. CIRCUIT BREAKER NEUTRAL 7) Turn power to the system OFF and reconnect pressure switch wires. Reapply power to the GROUND system and operate the spa or hot tub as normal. LOAD GROUND BUS BAR Adjustment Screw LINE 1 LINE 2 Calibration Scale (1lb.) P1 NEUTRAL GROUND S2 I 3 TO SPA CONTROL SYSTEM LOAD NEUTRAL MUST BE CONNECTED DIRECTLY TO GFCI AS SHOWN 5 14
  • 7. NO THERAPY JET OPERATION SYSTEM CONFIGURATION Water Shut-Off Valves are Closed - Open Shut-Off valves. Congratulations on your purchase of the Universal Series Control System. Jets Not Properly Adjusted - Adjust Jets properly. This series of controls has been developed to allow you complete flexibility during your Diverter Valve Not Properly Adjusted - Adjust diverter valve properly. installation. This Control System is configured to allow you to choose the voltage for each circuit Thermal Overload Tripping - Check for restricted flow of water. at the time of installation. We highly recommend that all component cords be replaced at the ! time of installation. NO LIGHT OPERATION The Universal conversion procedure MUST be accomplished PRIOR to connecting input service wiring. This control has been shipped from the factory with ALL circuits wired for ! 120 VAC. Light Bulb Defective - Replace bulb or contact your local dealer. VERIFY YOUR COMPONENT VOLTAGE REQUIREMENTS: 120 VAC will not harm a 240 VAC Reflector has Fallen Off - Replace deflector or contact your local dealer. component if operated temporarily. 240 VAC WILL harm a 120 VAC component almost Light Not Plugged-In - Plug in the Light. immediately. This is the reason we ship all circuits in the 120 VAC configuration. We cannot be held responsible for mis-wire related damage to components. Note: To utilize the Universal circuitry (120/240VAC), incoming service must be 240V/4-Wire. W WATER LEAKS We have made the conversion process simple and easy. After you have determined the Spa Overfilled - Adjust water level. voltage of your components (pump(s), air blower, ozonator etc.), you are now ready to Drain-Valve Left Open - Close drain valve. complete the conversion process. Color-Coded Neutral Wire connectors have been Couplings or Unions Loose - Tighten or contact your local dealer. provided to easily distinguish the circuit to be converted. By simply moving a Neutral Pump Seal Leaking - Contact your local dealer. wire from the Neutral side of the conversion terminal block, clearly marked and Plumbing / Connections Leaking - Contact your local dealer. located inside the control enclosure, to the Line 2 side completes the circuit conversion. Water Leaking from Spaside Control - Contact your local dealer. Follow the illustrations and step-by-step instructions. Water in Air Blower Plumbing - Contact your local dealer. Circuit Color Chart Red Connector = Pump 1 Brown Connector = Circulation Pump NO HEAT (Optional) Violet Connector = Pump 2 (Optional) Note: Ozonator Circuit 120V ONLY Blue Connector = Air Blower Temperature Not Set Correctly - Adjust “Set Point” Temperature. System Power Restriction - Depending on available power, the spa may have interlocks in place to shut off the heater when the pumps are switched to high speed. Step 1 Remove 2(ea) screws and open front cover of enclosure. Locate HIGH HEAT the conversion terminal block and desired connector (using ‘Circuit Color Chart” above). Carefully Temperature Sensor Not in Dry-Well - Place sensor in dry-well. remove connector from the Neutral Temperature Set Too High - Adjust “Set Point” Temperature. side. High Ambient Temperature - Remove spa cover. s) ral nt pone Neut Com GFCI TRIPS IMMEDIATELY (120V nts) 2 pone Line ! Com (240 V For correct GFCI breaker wiring, refer to page 5 for details. If you have a 3-wire/240V connected system, you will not have the Universal 13 6 option
  • 8.
  • 9.
  • 10. CONNECTION CONNECTION Below is an illustration showing our exclusive colored receptacles, located on the right side of Spaside Control: If equipped, install the Spaside Control per the manufacturers the control box. Use this illustration when connecting spa components. instructions. Once installed, connect the Spaside Control plug into the receptacle provided on the side of the control box (as shown in the illustration below). If the Spaside Control includes a Receptacle Color Chart thermostat, installed the temperature probe into the dry-well of the spa. RED RED Pump 1 / 2-Speed Pump 1 / 2-Speed PINK BROWN Pump 2 / 1 or 2-Speed Pump 2 / 2-Speed WHITE PINK Air Blower Pump 1 or 2 / 1-Speed YELLOW VIOLET Ozonator Air Blower GREEN YELLOW “Hot” Accessory Ozonator RED 3-Pin LIGHT VIOLET Circulation Pump Switched Accessory Spa Light: Using a suitable 2 ½ “ diameter hole-saw, cut a hole in the spa wall. Cut from inside the spa wall toward the outside to prevent splintering the inner surface. WHITE 2-Pin BLUE Remove any insulation material from around the hole (at least ½ “) at the outside spa wall. 12V Light Circulation Pump Install the gasket onto the light body and install the light into the hole. Take care not to over tighten the nut securing the light body. (Silicone sealant may be used in place of the gasket. Allow WHITE adequate time for sealant to cure before filling the spa.) 12V Light or Firemans Switch Assure that all plugs and receptacles are fully Note: It is recommended that the water level be stopped just above the level of the spa light until a connected. A loose connection can cause damage to thorough inspection for leaks can be completed. the system. Note: We utilizes the BLACK wire for ORANGE High-Speed and the RED wire for Low-Speed in Fiber Optic Two-Speed Pump Circuits. Keep this in mind GREEN when connecting a Two-Speed pump that has not been purchased with the system. “Hot” Accessory Light Bulb Light Body Spa Wall Gasket 9 10