Presenter : Harsha S (Dell R&D, Bangalore)
• IPMI stands for intelligent platform management  interface, designed by the Intel, IPMI is now at revision 2.0.• This st...
Management Application     Service Provider                                                  Proxy/Service Provider       ...
• Keyboard controller style system System       interface (KCS)            • System Management interface ChipInterface   •...
• Standard interface for management across vendors           • Serial Over Lan (SOL). This is a method to redirectFeatures...
Feature Use Cases• Power Management of the server• Monitoring SEL for the Platform issues• PET (Platform Event Trap)• OEM ...
• Monitor the power statistics of the               server             • Clear the power readings             • Monitor th...
System event logging(SEL) with OEM information     • System event logs     • OEM decoding from the log     • Sensor verifi...
List Sensor information     • List all the sensor present in the Server     • Sensor readings with threshold values[root@l...
Windows OS              • Remote debugging of the Windows Server                           kernel    Kernel               ...
SECURITY   •           •             Define Users             Define privileges  (IPMI    •           •             Encryp...
Dell supported commands•Powermonitor•MAC•Sel•Windbg•vFlash•LCD
IPV6 Support• The current support for the IPMITool is  restricted to the IPV4 address  communication for the out-of-band. ...
Ipmi specification     http://www.intel.com/design/servers/ipmi/index.htmOpen source link to ipmitool     http://ipmitool....
?
Upcoming SlideShare
Loading in …5
×

Harsha s ipmi_tool_osi

764 views
700 views

Published on

Published in: Technology
1 Comment
0 Likes
Statistics
Notes
  • Hi,

    Can I get the email / any other contact of Harsha S who talked on IPMI in your conf / seminer.
       Reply 
    Are you sure you want to  Yes  No
    Your message goes here
  • Be the first to like this

No Downloads
Views
Total views
764
On SlideShare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
3
Comments
1
Likes
0
Embeds 0
No embeds

No notes for slide

Harsha s ipmi_tool_osi

  1. 1. Presenter : Harsha S (Dell R&D, Bangalore)
  2. 2. • IPMI stands for intelligent platform management interface, designed by the Intel, IPMI is now at revision 2.0.• This standard accepted by DELL, IBM, INTEL and Others• Through IPMI can monitor and control the BMC(Board Management Controller) and Server• In-Band Management• - Communication over KCS• -Out-of-Band Management• IPMB, ICMB, PCI SMBus, LAN, Serial/Modem
  3. 3. Management Application Service Provider Proxy/Service Provider IPMI Messages IPMI I/F Channel IPMI I/F Channel-------------In- Band (KCS) ----------------------------------------------------- Out-Of-Band ------ IPMI H/W Interface O O Base Board Management Controller B Out of Band : Hardware Unit I/ Serial, Network, Modem, Chassis F Mgmt.
  4. 4. • Keyboard controller style system System interface (KCS) • System Management interface ChipInterface • Block Transfer • SMBus system interface(SSIF) • System interface • IPMBMessaging • ICMB • LANInterface • Serial/Modem • PCI SMBus
  5. 5. • Standard interface for management across vendors • Serial Over Lan (SOL). This is a method to redirectFeatures serial connections over an Ethernet cable. • Remote Management from LAN of • OS-independent management • Monitor Sensors, Sel(System event logs), FRU and etc. • PEF(Platform Event Filtering)IPMITool • Users, privileges and Authentication • OEM Management • Off-the-shelf software is available
  6. 6. Feature Use Cases• Power Management of the server• Monitoring SEL for the Platform issues• PET (Platform Event Trap)• OEM Command Support• Set Boot Options• Debug windows OS Kernel• Communicate to BMC even if the Server is OFF• Secured Login with RMCP+/RAKP
  7. 7. • Monitor the power statistics of the server • Clear the power readings • Monitor the individual power supply Power ratingsmanagement • Monitoring the power consumption • Monitoring the power history • Monitor and control the power budgeting • Monitor and control power capping
  8. 8. System event logging(SEL) with OEM information • System event logs • OEM decoding from the log • Sensor verification by event[root@lcg0954 ~]# ipmitool sel list 1 | 06/11/2008 | 22:34:44 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted5 | Pre-Init Time-stamp | Add-in Card #0x56 | Install Errorb | 08/21/2008 | 15:04:44 | Temperature #0x08 | Lower Non-critical going lowc | 08/21/2008 | 15:04:44 | Temperature #0x08 | Lower Non-critical going highd | 04/20/2010 | 17:29:35 | OS Boot | C: boot completed | Assertedf | 04/20/2010 | 17:29:35 | OEM record dc | 000137 | 003be4cd4b0010 | 04/20/2010 | 17:47:05 | OS Boot | C: boot completed | Asserted11 | 04/20/2010 | 17:47:05 | OEM record dc | 000137 | 0053e8cd4b0012 | 04/20/2010 | 17:52:20 | OS Stop/Shutdown | OS graceful shutdown | Asserted17 | 04/21/2010 | 16:51:41 | OEM record dd | 000137 | 00ff0005000018 | 04/22/2010 | 05:24:14 | OS Boot | C: boot completed | Asserted19 | 04/22/2010 | 05:24:14 | OEM record dc | 000137 | 003addcf4b001a | 04/22/2010 | 06:06:26 | OS Stop/Shutdown | OS graceful shutdown | Asserted1b | 04/22/2010 | 06:06:26 | OEM record dd | 000137 | 00ff000500001c | 04/21/2010 | 19:15:25 | OS Stop/Shutdown | OS graceful shutdown | Asserted1d | 04/21/2010 | 19:15:25 | OEM record dd | 000137 | 00ff000500001e | 08/23/2010 | 17:02:56 | OS Boot | C: boot completed | Asserted
  9. 9. List Sensor information • List all the sensor present in the Server • Sensor readings with threshold values[root@lcg0954 ~]# ipmitool sensorCPU Temp 1 | 35.000 | degrees C | ok | na | na | na | 76.000 | 78.000 | 80.000CPU Temp 4 | na | degrees C | na | na | na | na | 76.000 | 78.000 | 80.000Sys Temp | 31.000 | degrees C | ok | na | na | na | 76.000 | 78.000 | 80.000CPU1 Vcore | 1.184 | Volts | ok | 0.680 | 0.688 | 0.696 | 1.624 | 1.632 | 1.640CPU2 Vcore | 1.192 | Volts | ok | 0.680 | 0.688 | 0.696 | 1.624 | 1.632 | 1.6403.3V | 3.264 | Volts | ok | 2.912 | 2.928 | 2.944 | 3.648 | 3.664 | 3.6805V | 4.920 | Volts | ok | 4.416 | 4.440 | 4.464 | 5.520 | 5.544 | 5.56812V | 11.712 | Volts | ok | 10.464 | 10.560 | 10.656 | 13.344 | 13.440 | 13.5361.5V | 1.488 | Volts | ok | 1.296 | 1.312 | 1.328 | 1.664 | 1.680 | 1.6965VSB | 4.896 | Volts | ok | 4.416 | 4.440 | 4.464 | 5.520 | 5.544 | 5.568VBAT | 3.280 | Volts | ok | 2.912 | 2.928 | 2.944 | 3.648 | 3.664 | 3.680Fan1 | 10500.000 | RPM | ok | 200.000 | 300.000 | 400.000 | na | na | naFan2 | 8700.000 | RPM | ok | 200.000 | 300.000 | 400.000 | na | na | naPower Supply | 0x0 | discrete | 0x0000| na | na | na | na | na | naCPU0 Internal E | 0x0 | discrete | 0x0000| na | na | na | na | na | naThermal Trip0 | 0x0 | discrete | 0x0000| na | na | na | na | na | naThermal Trip1 | 0x0 | discrete | 0x0000| na | na | na | na | na | na
  10. 10. Windows OS • Remote debugging of the Windows Server kernel Kernel • Remotely monitor the Windows boot debugging processusing IPMITool • Real-time Windows Driver debugging Remote Machine With IPMITOOL Serial Data to winDBG Netw Tool Server OS. ork LAN Port WinDBG/KD Running BMC Controller
  11. 11. SECURITY • • Define Users Define privileges (IPMI • • Encrypt communication with BMC Version 2.0: RMCP/RMCP+: based on RAKP messages (HMAC like protocol) 2.0) • Serial-Over-Lan is encrypted with RMCP+ only
  12. 12. Dell supported commands•Powermonitor•MAC•Sel•Windbg•vFlash•LCD
  13. 13. IPV6 Support• The current support for the IPMITool is restricted to the IPV4 address communication for the out-of-band. Our plans are there to support he IPV6 protocol as well. Development is in progress..• This would be the major contribution to the open source community as support for the IPV6 Protocol.
  14. 14. Ipmi specification http://www.intel.com/design/servers/ipmi/index.htmOpen source link to ipmitool http://ipmitool.sourceforge.net/IPMI Tool Mailing list https://lists.sourceforge.net/lists/listinfo/ipmitool-devel