Your SlideShare is downloading. ×
Marioff   workshop utc pt
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Introducing the official SlideShare app

Stunning, full-screen experience for iPhone and Android

Text the download link to your phone

Standard text messaging rates apply

Marioff workshop utc pt

694
views

Published on


0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
694
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
13
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Sistema de protección contra incendios mediante agua nebulizada PARTE 1 PARTE 2 PARTE 3 PARTE 4 Marioff Group ¿Qué es HI-FOG® ¿Por qué HI-FOG® ? Aplicaciones HI-FOG ®?
  • 2. PARTE 1 - El Grupo Marioff  Actividad Diseñar, fabricar y suministrar sistemas de PCI  Producto HI-FOG® - sistema PCI mediante agua nebulizada  Misión Proteger del fuego a personas, bienes y la continuidad de los negocios  Beneficios Reducción de los daños por fuego, humo y agua Mínima interrupción de la actividad Sistema ecológico - inocuo para el medio ambiente Oficinas centrales, Vantaa, FinlandiaWorkshop UTC / Lisbon – May 10th 2012
  • 3. ¿Quiénes somos?Workshop UTC / Lisbon – May 10th 2012
  • 4. Grupo Marioff alrededor del mundo Oficinas Marioff HI-FOG® distribuidores/agentes distributors/agentsWorkshop UTC / Lisbon – May 10th 2012
  • 5. Grupo Marioff Una empresa de United Technologies Corporation  Ventas de 54.800 millones de dólares  225.600 empleados  Operando en 4.000 ubicaciones de 70 paises Otis Carrier Pratt & Whitney Sikorsky Hamilton Sundstrand Ascensores y Calefacción y aire Motores de aviación Helicópteros Sistemas industriales y escaleras mecánicas acondicionado aeroespaciales UTC Fire & Security UTC Power Seguridad y protección contra Células de combustible y incendios producción de energíaWorkshop UTC / Lisbon – May 10th 2012
  • 6. Grupo Marioff Incluido en la división UTC Fire & Security  Ventas de 5.740 millones de dólares  43.000 empleados  Operando en 250 ubicaciones de 43 paises Otis Carrier Pratt & Whitney Sikorsky Hamilton Sundstrand Ascensores y Calefacción y aire Motores de aviación Helicópteros Sistemas industriales y Otis Carrier Pratt & Whitney Sikorsky Hamilton Sundstrand escaleras mecánicas acondicionado aeroespaciales Elevators, escalators Heating, air -conditioning Aircraft engines Helicopters Aerospace, industrial systems UTC Fire & Security UTC Power UTC Fire & Security UTC Power Seguridad y protección contra- Células de combustible y Fire safety, security solutions Power systems, fuel cells incendios producción de energíaWorkshop UTC / Lisbon – May 10th 2012
  • 7. PARTE 2A ¿Qué es HI-FOG®?Workshop UTC / Lisbon – May 10th 2012
  • 8. ANTECEDENTES EN EL DESARROLLO DE SISTEMAS DE EXTINCIÓN POR AGUA NEBULIZADA Protocolo de Montreal1987 Objetivo: Limitar o prohibir la fabricación de carbofluorados CFC s que dañen la capa de ozono (HALON 1301). Límite año 2000 para la fabricación.1987 Accidente en las escaleras del Metro de Londres, estación de King s Cross. Reflexión en las redes de Metro: Desarrollar nuevos sistemas de extinción. Organización Marítima Internacional (IMO) impulsa programas de pruebas con el sistema1990 de agua nebulizada en buques. Objetivo: Desaparición del HALON 1301 y no volver a usar el CO2 por su peligro para las personas.1990 Accidente en el material móvil del Metro de Madrid, con 4 coches destruidos en un incendio en la estación de Cruz del Rayo.1996 Publicación de la norma NFPA 750 sobre sistemas de agua nebulizada.
  • 9. AGUA NEBULIZADANFPA 75O 1.1. Ámbito “Este estándar contiene los requisitos mínimos para el diseño, instalación, mantenimiento y pruebas de sistemas de protección contra incendios con agua nebulizada. Este estándar no proporciona criterios definitivos sobre eficacia frente al fuego ni ofrece una guía específica sobre cómo diseñar un sistema para controlar, suprimir o extinguir un incendio. La fiabilidad se obtiene mediante la obtención e instalación de sistemas que han demostrado su eficacia en ensayos de incendio como parte del proceso de listado.”
  • 10. AGUA NEBULIZADACEN 14972 Section 1: Scope “This document specifies requirements and gives information on design, installation and testing and gives criteria for the acceptance of fixed landbased watermist systems for specific hazards and provides fire test protocols for a variety of hazard groups. ….. In the absence of a generalized design method, it is the intent of this document that watermist systems are full-scale fire tested and its system component evaluations are conducted by qualified testing laboratories.”
  • 11. La Seguridad en el MercadoOtros Agentes Extintores NORMA  estandarización Factores K Clasificación de Riesgo SOLUCIONES ESTANDARIZADAS Densidades de Diseño Autonomía operativa
  • 12. La Seguridad en el Mercado Agente Extintor “X” NormaA = B = C = D Diseños estandarizados o normalizados
  • 13. La Seguridad en el Mercado Agua Nebulizada NormaA = B = C = D Performance Based Design
  • 14. Terminología PCI Los sistemas fijos de la protección contra incendios no siempre consiguen una extinción pero, al menos, deben conseguir una supresión o un control del incendio.Sistemas de extinción Completa supresión del mismo hasta la desaparición total de posibilidad de reignición.Sistemas de supresión Intensa reducción del calor radiante y prevención de la reignición, durante el tiempo de descarga.Sistemas de control Limitación del crecimiento del fuego y prevención de daños estructurales.
  • 15. ¿Qué es HI-FOG®? HI-FOG® es un sistema desarrollado de protección contra- patentado por Marioff incendios mediante agua fabricado nebulizada suministradoWorkshop UTC / Lisbon – May 10th 2012
  • 16. ¿Qué es HI-FOG®? Principios básicos es boquillas agua impulsada alta presión a través especiales mediante de creando agua nebulizada HI-FOG®Workshop UTC / Lisbon – May 10th 2012
  • 17. ¿Qué es HI-FOG®? Principios básicos el agua nebulizada HI-FOG® está formada por micro-gotas descargadas a alta velocidad en la base del fuegoWorkshop UTC / Lisbon – May 10th 2012
  • 18. ¿Qué es HI-FOG®? Principios básicos El fuego es suprimido o extinguido por la gran rapida vaporización máxima superficie de y produce absorción del enfriamiento de desplazamiento del calor radiante la niebla oxígeno de la llamaWorkshop UTC / Lisbon – May 10th 2012
  • 19. ¿Como funciona HI-FOG® ? Rociador convencional 1 >1000 m 1 1 s. Niebla Baja y Media 40 300 m 10 0.1 s. Presión HI-FOG ® 8000 50 m 400 0.003 s. Superficie refrigeración muy grande Vaporización muy rápidaWorkshop UTC / Lisbon – May 10th 2012
  • 20. Eficacia HI-FOG® OxígenoEfectos principales: SUPRESIÓN y/o EXTINCIÓN  Enfriamiento del fuego  Bloqueo del calor radiante  Inertización Calor Combustible HI-FOG® HI-FOG® Gran capacidad de enfriamiento y bloqueo Rápida evaporación, consiguiéndose la del calor radiante inertización en el foco del incendio
  • 21. ¿Qué es HI-FOG®? Principios básicos emplear reducir los permite minimizar el y el agua daños que consumo de agua eficazmente produce (aproximadamente un 90% menos que los sprinklers convencionales)Workshop UTC / Lisbon – May 10th 2012
  • 22. PARTE 2B Componentes principales del sistema HI-FOG®Workshop UTC / Lisbon – May 10th 2012
  • 23. Componentes principales del sistema HI-FOG® HI-FOG® sprinkler serie 1000 HI-FOG® sprinkler serie 1000 HI-FOG® sprinkler serie 1000 HI-FOG® sprayhead serie 1000 HI-FOG® sprayhead serie 1000 HI-FOG® spray pop-up para hangaresWorkshop UTC / Lisbon – May 10th 2012
  • 24. Componentes principales del sistema HI-FOG® HI-FOG® sprinkler serie 2000 HI-FOG® sprinkler serie 2000 HI-FOG® sprinkler serie 2000 con acabado especial Tubería de acero inoxidable de Accesorios de alta calidad sin alta calidad necesidad de soldaduraWorkshop UTC / Lisbon – May 10th 2012
  • 25. Componentes principales del sistema HI-FOG® Válvulas Diferentes tipos para diferentes aplicacionesWorkshop UTC / Lisbon – May 10th 2012
  • 26. Sistema DAU Lavado de humos y extinción en falsos suelos técnicos ZONA DE ASPIRACION BOQUILLA ABIERTA ZONA DE DESCARGA DECANTACIÓN DE AGUA AIRE LIMPIO HUMO Y GASES AGUA SUCIAWorkshop UTC / Lisbon – May 10th 2012
  • 27. Sistema DAUWorkshop UTC / Lisbon – May 10th 2012
  • 28. Sistema MAU Machinery space Accumulator Units  Autónomos: no requieren alimentación externa de agua o electricidad  Estructura modular  Botellas de agua no presurizadas hasta activación  Presurización por nitrógeno (200 bar)  Sistema de inundación total  Tiempo de protección y reserva de agua de 10 min Tipo Agua Nitrógeno MAU-50 1 x 50 litros 50 litros MAU-100 2 x 50 litros 50 litros MAU-150 3 x 50 litros 50 litrosWorkshop UTC / Lisbon – May 10th 2012
  • 29. Sistema MAUWorkshop UTC / Lisbon – May 10th 2012
  • 30. Sistema MAU Aprobaciones:  FM para espacios de maquinaria hasta 260 m³  VdS para espacios de maquinaria hasta 260 m³  Aprobaciones locales (Hong Kong, New York, etc.)Workshop UTC / Lisbon – May 10th 2012
  • 31. Sistema GPU Gas Pump Units  Sistema compuesto por bombas impulsadas por nitrógeno almacenado en cilindros de 50 litros y depósito de agua con capacidad variable  No requiere alimentación externa de electricidad  Estructura modular o integrada  Sistema de inundación total / sprinklers  Tiempo de protección y reserva de agua típico de 30 minWorkshop UTC / Lisbon – May 10th 2012
  • 32. Sistema GPUWorkshop UTC / Lisbon – May 10th 2012
  • 33. Sistema GPU Aprobaciones:  FM para espacios de maquinaria hasta 1.500 m³  VdS para espacios de maquinaria hasta 500 m³  FM y VdS: Riesgos ligeros y ordinarios  Aprobaciones locales (New York, etc.)Workshop UTC / Lisbon – May 10th 2012
  • 34. Sistema SPU Sprinkler Pump Unit - SPU  Sistema impulsado por bombas de alta presión accionadas por motor eléctrico  Descarga continua y estable de agua  Presión de salida máxima 140 bar  Suministro externo de energía  Sistema de inundación total / sprinklers  Tiempo de protección y reserva de agua típico de 30 minWorkshop UTC / Lisbon – May 10th 2012
  • 35. Sistema SPUWorkshop UTC / Lisbon – May 10th 2012
  • 36. Sistema SPU Aprobaciones:  Protección de espacios de maquinaria hasta 6.600 m³ (IMO MSC/Circ. 1165)  Sistema MT4 : Aprobaciones de Marina  Aprobación VdS para Galería de Cables  Aprobación VdS y FM: Riesgos ligeros y ordinariosWorkshop UTC / Lisbon – May 10th 2012
  • 37. PARTE 3 HI-FOG® AplicacionesWorkshop UTC / Lisbon – May 10th 2012
  • 38. Referencias HI-FOG® en marina Cruceros Yates de lujo Ropax ferrys Buques militares Plataformas Offshore Buques de cargaWorkshop UTC / Lisbon – May 10th 2012
  • 39. HI-FOG® - Aplicaciones de edificación & construcciónWorkshop UTC / Lisbon – May 10th 2012
  • 40. HI-FOG® - Aplicaciones Terrestres Riesgo ligero y ordinario (LH / OH)Workshop UTC / Lisbon – May 10th 2012
  • 41. Referencias HI-FOG® Aplicaciones en riesgo ligero y ordinario  Hoteles  Hospitales  Residencias  Aeropuertos  Oficinas  CPD’s  Museos y edificios históricos  Edificios en altura  Hangares  ArchivosWorkshop UTC / Lisbon – May 10th 2012
  • 42. Hoteles Rome Marriott Park Marriott Regents Park, Londres, Marriott 47 Park Hotel, Roma, Italia Reino Unido Street, Londres, Reino Unido  Protección de la reputación del hotel  Asegura la continuidad de las operaciones  Facilidad de instalación, sin interrupción de la actividadWorkshop UTC / Lisbon – May 10th 2012
  • 43. Edificios de oficinas y universidades Sede de BP Oficinas del banco Norde, Biblioteca Bochum, Alemania Helsinki, Finlandia universitaria, Alemania Universidad Domus, Oslo, NoruegaWorkshop UTC / Lisbon – May 10th 2012
  • 44. Edificios en Altura  Cirrus, Helsinki, edificio residencial más alto de Finlandia  28 plantas  1,000 sprinklers HI-FOG®  Tubería de pequeño diametro  Sin necesidad de bombas de refuerzo  Volumen de agua descargada 90% inferior a los sistemas de sprinklers convencionalesWorkshop UTC / Lisbon – May 10th 2012
  • 45. Hospitales  Hospital Universitario de Muenster, Alemania  Protección de las habitaciones  48 válvulas de sección  3,200 HI-FOG® sprinklers  Hospital Central de North Karelia, Joensuu, Finlandia  60,000 m2  90% menos cantidad de agua  Fácil instalación  Tiempos de interrupción practicamente inexistentesWorkshop UTC / Lisbon – May 10th 2012
  • 46. Residencias  Koukkuniemi (Tampere, Finlandia)  11 edificios  Edificio de servicios y cafetería  Túnel de servicio de 600 mWorkshop UTC / Lisbon – May 10th 2012
  • 47. Iglesias Iglesias de madera, Noruega Iglesia de Tuusula, Finlandia Haukipudas, Finlandia  Mínimos daños colaterales tras la activación  Instalación adaptada a la estética del edificioWorkshop UTC / Lisbon – May 10th 2012
  • 48. Galerías de arte y museos Photo © Jussi Tiainen Photo © Manuel G. Vicente Wellamo Maritime Museum, National Portrait Museum of Contemporary Art, Kotka, Finlandia Gallery, Londres, Reino Vigo, España Unido HI-FOG® protege el patrimonio Winnipeg Art Gallery, Canada National Gallery of Art, Washington D.C., EEUUWorkshop UTC / Lisbon – May 10th 2012
  • 49. Galerías de arte y museos Protegiendo lo irremplazable  El edificio en sí mismo  Cuadros de valor incalculable  Obras sobre papel  Preservando la herencia cultural para futuras generaciones Instalación sin soldaduras – mínimo riesgo de incendio, incluso en esta etapa National Portrait Gallery, Londres, Reino UnidoWorkshop UTC / Lisbon – May 10th 2012
  • 50. Bibliotecas y archivosBiblioteca de la Duquesa AnnaAmalia, Weimar, Alemania Goethe trabajó aquí durante 30 años Un trágico incendio indujo a proteger la sala con HI-FOG®: • Cuatro pisos, habitación Rococo, torre • Colección de arte de valor incalculable • Manuscritos de la época medieval • Incunables y manuscritos • Biblioteca privada de Nietzsche • Importante patrimonio cultural alemánWorkshop UTC / Lisbon – May 10th 2012
  • 51. Teatros The Bolshoi Theatre, Moscú, Rusia La Scala, Milan, Italia Un solo equipo HI-FOG® puede proteger diferentes riesgosWorkshop UTC / Lisbon – May 10th 2012
  • 52. Centros de Proceso de Datos (CPD) Data Hotel CX2, Kuala Lumpur, Malasia  Suministra servicios a empresas  Dos alas interconectadas de 5 y 6 plantas  Todo el recinto está protegido con HI-FOG®  9.000 m² de servidores  Generadores de emergencia  Salas UPS (SAI)  Oficinas, pasillos, etc.  2,800 HI-FOG® sprinklersWorkshop UTC / Lisbon – May 10th 2012
  • 53. Barcelona Supercomputing Center BSCWorkshop UTC / Lisbon – May 10th 2012
  • 54. IT e instalaciones de telecomunicaciones  IBM  Allianz  CERN  IX-Europe  Telecity  Vodafone  Telia  Sony Ericsson  IKEA  BMW  Red Cross  Credit Mutuel  ABB  Coca-Cola  Malaysia Telecom  Goldman Sachs  Natwest Bank  Chase Manhattan BankWorkshop UTC / Lisbon – May 10th 2012
  • 55. Centros de Proceso de Datos (CPD) Centro almacenamiento CPD de Telefonica, Madrid, National Support Centre de datos España Para el Eurofighter, Reino Unido LD4, Londres, Reino Unido Protección de la instalación con una minima cantidad de agua Total seguridad para las personas Rapidez y facilidad de instalación (tuberías de pequeño diámetro)Workshop UTC / Lisbon – May 10th 2012
  • 56. HI-FOG® - Aplicaciones de industria & energíaWorkshop UTC / Lisbon – May 10th 2012
  • 57. Aplicaciones industriales HI-FOG® Generación de energía Fabricación  Turbinas de gas  Líneas de pintura  Generadores Diesel  Aerogeneradores  Túneles de viento  Celdas de prueba de motores Distribución de energía  Maquinaria de producción  Transformadores  Galerías de cableado Minería  Salas de cableado  Plantas de procesamiento Industria Papelera  Cintas transportadoras  Maquinaria  Cintas transportadoras Industria alimentaria  Secadoras de pulpa  Freidoras industriales  Espacios de maquinariaWorkshop UTC / Lisbon – May 10th 2012
  • 58. Distribución de energía  Subestaciones  Transformadores  Elevada rigidez dieléctricaWorkshop UTC / Lisbon – May 10th 2012
  • 59. Generación de energía  Turbinas de gas  Generadores Diesel  Aerogeneradores  Salas de máquinasWorkshop UTC / Lisbon – May 10th 2012
  • 60. Distribución de energía y datos Galerías de cableado Voest Alpine, Austria (3.600 m, 116 tramos de protección)Workshop UTC / Lisbon – May 10th 2012
  • 61. SWB AG Power plant, Bremen, GermanyUn sistema HI-FOG ® protege las cintas transportadoras de carbón, 460 m.Realización de ensayos de fuego a escala real para comprobar la eficaciadel sistema.
  • 62. Cabinas de pintura Airbus A380 production site, Wales, UKWorkshop UTC / Lisbon – May 10th 2012
  • 63. Hangares aeronáuticos Uso civil y militar  Ventajas comparativamente con sistemas tradicionales: Aviones y helicópteros - Mínimo riesgo de corrosión Sistemas en techo y suelo - Fácil mantenimiento y limpieza, mínima interrupción - Enfriamiento efectivo, bloqueo del calor radiante
  • 64. CASO: planta de extracción por disolventes  Planta de refino de cobre  Protección completa de la planta, principalmente riesgos de Clase B  Dos grupos SPUD  11 válvulas de sección  290 spray heads  Reducción de los costes de mantenimiento comparado con los sistemas de espuma  Sistema ecológicoWorkshop UTC / Lisbon – May 10th 2012
  • 65. HI-FOG® - Aplicaciones de transporte & infraestructurasWorkshop UTC / Lisbon – May 10th 2012
  • 66. Insfraestructuras de transporte  Túneles ferroviarios y de carretera  Estaciones de Metro  Instalaciones subterráneas  TrenesWorkshop UTC / Lisbon – May 10th 2012
  • 67. Trenes de Aeropuertos Aeropuerto Washington Dulles, EEUUWorkshop UTC / Lisbon – May 10th 2012
  • 68. Estaciones de Metro Metro de Madrid, EspañaWorkshop UTC / Lisbon – May 10th 2012
  • 69. Trenes Más de 220 trenes de Metro de Madrid protegidosWorkshop UTC / Lisbon – May 10th 2012
  • 70. Túneles de carretera Paris  A86 - Túnel oeste, parte de la super-circunvalación  HI-FOG® protege un sector de 10 km, con dos niveles superpuestos  Tres estaciones de bombeo Madrid  Túnel circunvalación M30  HI-FOG® protege 5 sectores Helsinki  HI-FOG® protege el túnel de servicio del centro  Primer túnel con sistema automático de protección contra incendios de FinlandiaWorkshop UTC / Lisbon – May 10th 2012
  • 71. Protección del túnel A86, Paris  2 x10 km de via de 3 carriles  3 estaciones de bombeo cada 5 km  3 secciones HI-FOG® activados simultáneamente  Activación manual por detección mediante CCTVWorkshop UTC / Lisbon – May 10th 2012
  • 72. Túnel A86, Paris Probablemente la instalación fija de protección contra incendios más grande del mundoWorkshop UTC / Lisbon – May 10th 2012
  • 73. Túnel de la A86, Paris: estación de bombeoWorkshop UTC / Lisbon – May 10th 2012
  • 74. PARTE 4 ¿Por qué HI-FOG® ?Workshop UTC / Lisbon – May 10th 2012
  • 75. HI-FOG® vs CONVENCIONALCantidad de agua  90% menos  Espacio de Aljibe  Daños por descargaEficacia  Convencional  Control  HI-FOG ®  Supresión / Extinción Versatilidad  Convencional  Ligero / Ordinario  HI-FOG ®  Ligero / Ordinario / Espacios de maquinaria
  • 76. HI-FOG ® vs Agua PulverizadaCantidad de agua  60% menos ( Alta presión / Media Presión )  Espacio de Aljibe  Daños por descargaEficacia  Agua Pulverizada  Control / Supresión  HI-FOG ®  Extinción  Refrigeración menor Versatilidad  Pulverizada  siempre equipo eléctrico (rigidez dieléctrica no demostrada)  HI-FOG ®  GPU (neumático) / SPU (eléctrico)
  • 77. HI-FOG ® vs Gases Enfriamiento  Los gases no usan agua  posibilidad de reignición Daños colaterales  Daños por descarga indeseada  Vidas humanas, coste recarga  Daños en descarga  Productos descomposición térmicaVersatilidad  Gases: 1 Riesgo  1 equipo / 2 riesgos  2 equipos ….  HI-FOG ®: 1 riesgo  1 equipo / 2 riesgos  1 equipo …. Requisitos arquitectónicos  Gases  Estanqueidad próxima 100%, necesidad de Door Fan Test  HI-FOG ® : Permisibilidad de aperturas
  • 78. HI-FOG® vs competencia agua nebulizada ® ¿ Por qué HI-FOG ?
  • 79. APROBACIONES www.approvalguide.com www.vds.deWorkshop UTC / Lisbon – May 10th 2012
  • 80. HI-FOG® vs competencia agua nebulizada ¿ Por qué HI-FOG®?
  • 81. Marioff realiza ensayos de fuego constantemente  HI-FOG® ha sido testado en más de 6.000 ensayos de fuego a escala real Más que cualquier otro sistema de protección contra incendios  HI-FOG® ha sido testado en una gran variedad de aplicaciones diferentes Más que cualquier otro sistema de protección contra incendios HI-FOG® tiene más aprobaciones / fire tests que cualquier otro sistema de agua nebulizadaWorkshop UTC / Lisbon – May 10th 2012
  • 82. Historial de Marioff en ensayos de fuego = Historial de desarrollo estandarizado Ensayo estándar Aprobación tipo Ensayos de Ensayos específicos por Aprobación caso por caso fuego aplicación Ensayos específicos para Aprobación para un proyecto proyectos específicos Test de garaje Wild MarketWorkshop UTC / Lisbon – May 10th 2012
  • 83. HI-FOG® ensayos de fuego Aplicaciones en marina  Zonas ocupadas, espacios públicos, áreas de servicio  Espacios de maquinaria: protecciones locales  Galerías  Diversas aplicaciones militares  Categoría especial y espacios Ro-Ro  Freidoras industriales  Conductos de lavandería  Espacios de maquinaria: protección del compartimientoAplicaciones en tierra: edificios y construcción  Riesgo ligero y ordinario 1 zonas ocupadas: hoteles, oficinas  Espacios reducidos con cableado / galerías de cable  Riesgo ordinario 2: aparcamientos  Riesgo ordinario 3 e.g. archivos, centros comerciales  Riesgo ordinario 4 e.g. teatros, cines  Prisiones  Salas de ordenadores Aplicaciones en tierra: industria y energía  Turbinas de gas, espacios de maquinaria y riesgos especiales  Conductos de extracción  Transformadores en el exterior  Camaras anecoicas  Cocinas industriales  Galerías industriales de cableado  Wet benchesWorkshop UTC / Lisbon – May 10th 2012
  • 84. HI-FOG® ensayos de fuego – cont. Aplicaciones en tierra: túneles e infraestructura de transporte  Túneles ferroviarios y de carretera  Túneles de ensayos climáticos  Trenes  Escaleras mecánicasMiscelánea  Enfriamento de ventana  Protección estructural  Equipos manualesWorkshop UTC / Lisbon – May 10th 2012
  • 85. ®HI-FOG vs competencia agua nebulizada ® ¿ Por qué HI-FOG ?
  • 86. Servicios técnicos disponibles Fase inicial del proyecto • Estudio técnico y preparación de oferta económica • Fichas técnicas de los componentes Fase posterior • Propuesta de planos de distribución de tubería y equipos de bombeo • Memoria técnica Tras pedido y suministro de material • Entrega de manuales y certificados de calidad de los componentes • Commissioning y puesta en marcha de la instalación • Posibilidad de mantenimiento de la instalación
  • 87. Opera Hotel, Paris – Abril 2005 Fuego iniciado a partir de una vela 00:00:00 No hay sprinklers, el fuego se extiende 00:05:00 Bomberos inician el ataque al fuego 00:30:00 Extinción del incendio 02:00:00 24 muertos y 50 heridosWorkshop UTC / Lisbon – May 10th 2012
  • 88. Hotel Wauregan, Noruega Hotel Rive Gauche, Paris Noviembre 2007 Julio 2007  Activación del sistema  Activación del sistema de tradicional de sprinklers sprinklers HI-FOG®  Parada del sistema después  Parada del sistema después de 30 minutos de 30 minutos  Inundación en 8 habitaciones  Humedad en la habitación (no y zonas comunes hubo otras areas afectadas)  La habitación fue totalmente  Edifício cerrado durante 4 recuperada en una semana semanas Daños: trabajo extra de Total de daños: 300.000€ limpieza y decoraciónWorkshop UTC / Lisbon – May 10th 2012
  • 89. CASO REAL Dos fuegos casi idénticos en el mar (Espacio de Maquinaria) M/S Nordic Empress (2001) M/S Explorer of the Seas (2002) Sistema (NO HI-FOG®) HI-FOG® activado en 15 segundos  Reparación del daño  Sustitución de una sonda  Compensaciones  Limpieza manual  Reservas de hotel y vuelos  Parada del buque  2 semanas sin beneficios Total: 8,8 millones de Total: 500 dólares dólares Datos cortesía de Royal Caribbean InternationalWorkshop UTC / Lisbon – May 10th 2012
  • 90. GraciasWorkshop UTC / Lisbon – May 10th 2012