Joint NetApp and Cisco Solutions for SAP: FlexPod and HANA

1,352
-1

Published on

Presentation by Craig Sullivan, NetApp SAP Solutions Architect, at SAP TechEd.

Published in: Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
1,352
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
48
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide
  • [PLACEHOLDER TEXT]
  • Example eBay
  • [PLACEHOLDER TEXT]
  • [PLACEHOLDER TEXT]
  • [PLACEHOLDER TEXT]
  • Joint NetApp and Cisco Solutions for SAP: FlexPod and HANA

    1. 1. Joint NetApp and Cisco Solutions for SAP: FlexPod and HANA Craig Sullivan, NetApp SAP Solutions Architect 1
    2. 2. FlexPod: The global leader in Integrated Infrastructure  Standard, prevalidated, best-inclass infrastructure building blocks Cisco UCS™ B-Series Blade Servers and Cisco UCS Manager Cisco Nexus® Family Switches  Flexible: One platform scales to fit many environments and mixed workloads – Add applications and workload – Scale up and out  Simplified management and repeatable deployments NetApp® FAS 10GE and FCoE  Design and sizing guides  Services: Facilitate deployment of different environments 2
    3. 3. FlexPod Datacenter for SAP Solution Overview Application Virtualization SAP® Adaptive Computing VMware vSphere Extensible Open Management Server Virtualization VMware® vSphere® Compute Node Virtualization Cisco Unified Computing System™ Network Virtualization Cisco Nexus® 1000v, Nexus 5000 Storage Virtualization NetApp® MultiStore® 3
    4. 4. Tenant Components Tenant Description Infrastructure Tenant Computing Network Storage ACC SMSAP vSphere® Tenant Description Tenant 2 Tenant 3 DHCP DNS NIS DHCP DNS NIS VLAN, Routing, Firewall VLAN, Routing, Firewall VLAN, Routing, Firewall Primary and Backup vFiler® Units Primary and Backup vFiler Units Primary and Backup vFiler Units DNS
    5. 5. Integrated Data Protection for All Data Operating Systems VMware® vSphere® Integrated Backup Data Replication with with SnapManager® for VI Protection Manager Nonapplication Data Backups with Protection Manager Data Replication with Protection Manager Application Data Backup Backup Data Replication with Protection Manager Backup Primary Primary Primary vFiler® Units Primary SAP® Integrated Backup with SnapManager for SAP Backup vFiler Units 5
    6. 6. Application and Data Mobility VM VM ESX® Server VM ESX Server Bare Metal Bare Metal 6
    7. 7. Application and Data Mobility VM ESX® Server VM VM ESX Server Bare Metal Bare Metal
    8. 8. Application and Data Mobility VM ESX® Server VM ESX Server Bare Metal Bare Metal 8
    9. 9. Application and Data Mobility VM ESX® Server VM ESX Server Bare Metal Bare Metal 9
    10. 10. System Refresh Automated data extraction Storage cloning Automated OS/DB postprocessing Automated SAP® postprocessing FlexPod® Approach Effort: Several hours Typically 20 x faster and fully automated Effort: Several days Standard Approach Extract Source Data Restore from OS/DB Tape Postprocessing SAP Postprocessing 10
    11. 11. Certified HANA Solutions Cisco UCS with NetApp Storage for SAP HANA 11
    12. 12. The SAP HANA + NetApp Building Block Simplicity and performance  Building block architecture scales without logical limits  Shared storage for nodes mandatory SAP HANA Database 512 GB 512 GB 512 GB 512 GB 10Gb Ethernet, NFS  Standards-based access and interconnect FAS3250AE Ready to scale out by block 12
    13. 13. Cisco - Certified Appliances Building Block May 2012 May 2013 Planned 4 x compute nodes 4 x compute nodes 6 x compute nodes 1 x FAS3240A 1 x FAS3250AE 1 x FAS3250AE 2 x DS4243 600GB 15K 2 x DS4243 600GB 15K 3 x DS2246 600GB 10K 13
    14. 14. Tailored Datacenter Integration Ability to certify on-site non-appliance configurations SAP HANA Database 512 GB 512 GB 512 GB 512 GB 10Gb Ethernet, NFS FAS6290HA 512 GB 512 GB
    15. 15. DR building block (Cisco) SAP HANA Production 512 GB 512 GB 512 GB 512 GB Data 1 Data 2 Data 3 Data 4 Four Hana nodes attached to two active storage controllers. Controller B and D are not actively used during normal operation. 10GbE Controller A MDS Switches Controller B 8Gb FC SourceA 8Gb FC MirrorA HA Pair MetroCluster Data 1/2 Controller D Controller C 8Gb FC SourceC Data 3/4 8Gb FC MirrorC HA Pair MetroCluster 15
    16. 16. Servers at DR site for Dev/Test Servers at the DR SAP HANA Dev/Test site are used for Dev/Test, but must have their own 512 GB 512 GB 512 GB 512 GB 512 GB storage and network. SAP HANA Production 512 GB 512 GB 512 GB Data 1 Data 2 Data 3 Data 1 Data 4 Data 2 Data 3 Data 4 10GbE Controller A Controller B Dev/Test 8Gb FC SourceA 8Gb FC MirrorA HA Pair Data 1/2 Controller D Controller C 8Gb FC SourceC Data 3/4 8Gb FC MirrorC HA Pair 16
    17. 17. Site failover SAP HANA Production 512 GB 512 GB 512 GB 512 GB Data 1 Data 2 Data 3 DEV/Test systems are shut down and servers are used for production. SAP HANA Production DR 512 GB 512 GB 512 GB Data 1 Data 4 512 GB Data 2 Data 3 Data 4 10GbE Controller A Controller B Dev/Test 8Gb FC SourceA 8Gb FC MirrorA HA Pair Data 1/2 Controller D Controller C 8Gb FC SourceC Data 3/4 8Gb FC MirrorC HA Pair 17
    18. 18. NetApp Snapshot Backup SAP HANA Production Database Compute Node 1 Compute Node 2 Compute Node 3 Compute Node 4 Step 1: SnapCreator triggers a SAP HANA global synchronized backup savepoint via hdbsql statement (SAP note 1703435) 10Gb Ethernet, NFS Data 1 Log 1 Data 2 Log 2 Data 3 Log 3 Data 4 Log 4  Backup in minutes without impact to production Step 2: Snapshot copies are created on storage layer Step 3: Snapshot copies can be replicated asynchronously on storage layer  Restore in minutes  With the current HANA release a storage based Snapshot can only be restored, a forward recovery is not possible yet Backup Volumes 18
    19. 19. 19
    1. A particular slide catching your eye?