Infrastrukturen til fremtidens løsninger
Kravene til din kablede infrastruktur øges hele tiden på grund af nye hastigheder og nye applikationer. Hastigheder på 10/40 Gbit Ethernet på kobber og 40/100/400 Gbit på fiber stiller krav til din installationen på samme måde som nye applikationer gør det. Det er bl.a. applikationer som Distribueret sensor netværk og LED belysning, indendørs mobildækning og nye PoE over WLAN standarder samt bygningsstyring.

Published in Technology
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Be the first to comment
    Be the first to like this
No Downloads

Views

Total Views
197
On SlideShare
0
From Embeds
0
Number of Embeds
3

Actions

Shares
Downloads
17
Comments
0
Likes
0

Embeds 0

No embeds

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
    No notes for slide
  • The cabling plant is interconnected by using MPO connectors
  • These are the fibre PMDs (Physical Medium Dependent) for 40G/100G Ethernet.
    Go through the slides.
    SR: Short Reach
    LR: Long Reach
    ER: Extended Reach
    Three other PMDs: 40GBASE-KR4 (for backplane technology) and 40GBASE-CR4 and 100GBASE-CR10 using expensive twinaxial cables (supported distance is 7.5 m).
  • A few weeks ago a company called Avago Technologies based in San Jose, California announced a new pluggable interface supporting 40 and 10G Ethernet.
    They themselves proved a verified link distance of 300m for OM3 and 400m over OM4 fibre.
    So this goes to show the standards are not going to be the limiting factor when it comes to transmission lengths and already we have vendors greatly exceeding them with marketable products and solutions.
  • PUE = Power Usage Effectiveness. Ratio of (Total Power Consumed) to (Power Consumed by IT Equipment). Industry typical: 1.8 to 2.9
    CommScope’s highly innovative evaporative cooling and reheating system allows for deployment in low and high temperature and humidity environments without the need for supplementary cooling.
    DX = Direct Expansion. Common technology used in commercial air conditioners using a refrigerant.
  • Location. Location. Location.
    Locate a device connected to a faceplate/port, within a room/rack, connected to a switch.

Transcript

  • 1. Infrastrukturen til fremtidens løsninger Arne Keller Nordic Regional Technical Manager
  • 2. 2PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc THE DATA CENTER IS A LIVING PART OF YOUR ORGANIZATION, DRIVEN BY THE CHANGING LANDSCAPE AND THE NEEDS OF YOUR STAKEHOLDERS. Investment preservation Sustainability Agility Efficiency
  • 3. 3PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc Today’s Data Centre and Emerging Trends and Technologies Big Data Virtualized Green Cloud ConvergedDCIMSDN Ethernet FCoEInfiniband iSCSi ........
  • 4. 4PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc Cabling in Data Centres
  • 5. 5PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc Datacenter Design The future will be diferent from today
  • 6. 6PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc Pre-Terminated Cabling in the Data Centres – Why Successful? • Typical pre-term copper install is eight times faster than field term • Reduces deployment risk • “Phase II” install much less disruptive • Minimal packaging on site - GREEN Installation time dramatically reduced
  • 7. 7PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc InstaPATCH Quattro • UTP Trunk Cables & Breakouts – CMR / CMP / LSZH – Ribbonized or Bundled – High Density MC Connector – MC-MC or MC-RJ45 options • 4-Port Modular Cassettes – High Density MC connector as rear interface • Modular Panels – 24p 1U • Intelligent Ready & Enabled – 48p 1U High Density
  • 8. 8PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc • Supports ALL fiber applications • Simple, scalable architecture – Guaranteed polarity (Tx  Rx) – Migrates easily from duplex to parallel • Industry-best application support – Distance, flexibility, operating margin – 40G/100G Ethernet & 16G FC to 170m • Highest Density in the industry • Elegant 360 design / Intelligence-Ready LAN Switch 40G/100G InstaPATCH 360 – Path to 100Gig
  • 9. 9PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc 40G/100G Ethernet: Current Fibre PMDs 40GbE PMDs 40GBASE-SR4 4 Lanes @ 850 nm ≥100 m with OM3 ≥150 m with OM4 40GBASE-LR4 4λ CWDM @ ~1310 nm ≥ 10 km with OS1/OS2 40GBASE-FR 40G @ ~1550 nm ≥ 2 km with OS1/OS2 100GbE PMDs 100GBASE-SR10 100GBASE-LR4 4λ WDM @ ~1310 nm ≥ 10 km with OS1/OS2 100GBASE-ER4 4λ WDM @ ~1310 nm ≥ 40 km with OS1/OS2 10 Lanes @ 850 nm ≥100 m with OM3 ≥150 m with OM4
  • 10. 10PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc 40/100G: Multimode or Singlemode? Multimode module (40GBASE-SR4) Singlemode module (40GBASE-LR4) Density 16 ports/ card 3-4 ports/ card Power (40G) ~1.5W/ port ~8W/ port Cost x 11x Distance* 150m (OM4) > 150m
  • 11. 11PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc • Impact of moving from 1 to 10 Gigabit Ethernet for server uplinks • Higher speed, lower latency links have direct impact on performance Big Data Study http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9670/white_paper_c11-690561.pdf Response Time Big Data network performance 1G versus 10GbE uplinks 25% Reduction
  • 12. 12PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc • Next Gen. 100GE – 10G/lane 25G/lane – Reduces MM cabling to single row MPO (QSFP transceiver) • Potential seamless upgrade from 40GE – Alternative SM solution using parallel fibre seems likely (QSFP) • Projected to save at least 50% on transceiver costs • 32G Fibre Channel (FC-PI-6) – Serial transmission – At least 100m on OM4 • 128G (4x32G) Fibre Channel – Parallel transmission Applications on the Horizon
  • 13. 13PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc MM or SM on Cisco/HP equipment? Prices fromPrices from www.dustin.sewww.dustin.se (SEK)(SEK) 20102010 20112011 20122012 2013-102013-10 • 1GB GBIC Cisco Multimode 3295 2695 2099 1899 • 1GB GBIC Cisco Singelmode 6195 5695 5999 5199 • 1GB SFP HP Multimode 3195 2895 1299 • 1GB SFP HP Singelmode 5695 5195 3999 • 10GB SFP Cisco Multimode --- 7995 8699 5099 • 10GB SFP Cisco Singelmode --- 20995 21499 19999 • 10GB SFP+ HP Multimode 11995 11995 5499 • 10GB SFP+ HP Singelmode 24495 22495 12999 In 2011, 1Gb multimode interface was 48% less than singlemode In 2013 , 1Gb multimode interface was 65% less than singlemode In 2011, 10Gb multimode interface was 54% less than singlemode In 2013, 10Gb multimode interface was 77% less than singlemode
  • 14. 14PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc MM or SM on Cisco/HP equipment? Prices from www.dustin.se (SEK)Prices from www.dustin.se (SEK) 20102010 20112011 20122012 2013-102013-10 • 1GB GBIC Cisco Multimode 3295 2695 2099 1899 • 1GB GBIC Cisco Singelmode 6195 5695 5999 5199 • 1GB SFP HP Multimode 3195 2895 1299 • 1GB SFP HP Singelmode 5695 5195 3999 • 10GB SFP Cisco Multimode --- 7995 8699 5099 • 10GB SFP Cisco Singelmode --- 20995 21499 19999 • 10GB SFP+ HP Multimode 11995 11995 5499 • 10GB SFP+ HP Singelmode 24495 22495 12999 40G Ethernet multimode interface is 10 000 USD (listprice) less than singlemode 100G Ethernet multimode interface is 80 000 USD (listprce) less than singlemode
  • 15. 15PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc CommScope Data Center on Demand Truly Modular Data Center • Scalable - 1, 4, 10, 20 Rack Configurations – Expandable while powered • Rapid Deployment • Highly Efficient Evaporative Cooling System – Low Maintenance / Green – Wide Range of Operating Environments • High / Low Temperature & Humidity – Real PUE - 1.01 to 1.06 • Customizable Upon Order – Tier II, Tier III, Mixed, Custom, w – kW/Rack ranges - <10, 10-20, & 20-35 kW – Input Voltages (200-240v or 380-415v) – Optional Vestibules – Security, Fire, PDUs, UPS, Generator, Transformers – Optional Integrated DX or Chilled Water Coils
  • 16. 16PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc CommScope DCU-04 Expandability – Seamless Hot/Cold Aisles
  • 17. 17PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc DCoD Interior Familiar & Manageable Large Cold Aisle Large Hot Aisle Network Cabling Large Vestibule Standard Vestibule
  • 18. 18PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc Introducing SYSTIMAX imVision
  • 19. 19PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc What challenges might you be facing? • I have to document infrastructure records manually, this is very time consuming. • Even simple changes to my network take a long time to plan and complete. • Sometimes, planned changes cause unplanned problems. • It is sometimes hard to recover from issues quickly. • I am always Reacting to the unexpected. • I have to audit my network several times during a year, changes may not be done during this time. • There are a growing number of networked devices on my infrastructure, it is hard to keep track of them all. • I find myself buying infrastructure capacity as this is easier and faster than checking what I have already. • My team manages many remote sites, this is a challenge to do effectively. My Network is becoming very difficult to manage…
  • 20. 20PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc imVision a Web-based live documentation Browser Html/http Database Server (MS-SQL) Application Server Windows Services Web Server (IIS) Web ServicesSOAP/AJAX/JSON
  • 21. 21PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc • Optimizing the Business Output of IT – Performance – Agility – Availability • Capacity Planning – Making every square foot count • Containing Costs – OPEX (reduce) – CAPEX (avoid or postpone) DCIM: A dynamic game-changer
  • 22. 22PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc • See, identify, and resolve issues across silos: – Assets – Power – Connectivity – Space – Cooling, etc. • Manage assets and their inter- dependencies • Bridge IT, Facilities, Business, Finance, and Real Estate DCIM objectives: Holistic insight into the physical ecosystem
  • 23. 23PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc Ubiquitous In Building Wireless Service ION Wireless Capacity Data Center Management Increase Efficiency and Reduce Complexity iTRACS Infrastructure Management Improve Availability & Reduce Complexity imVision iTRACS Modular Data Center Increase Scalability & Reduce Investment DCoD Optimize Energy & Space Efficiency Redwood imVision Energy & Space Reliable Backup Power for Business Continuity Fuel Cells Power Services Trusted Advisor Added Value Services Comprehensive Portfolio of DATA CENTER Solutions Data Transmission Structured Cabling SYSTIMAX Uniprise CommScope Data Center Solutions
  • 24. 24PRIVATE AND CONFIDENTIAL © 2011 CommScope, Inc Thank You