Precise Glove Box Overview Presentation
Upcoming SlideShare
Loading in...5
×
 

Precise Glove Box Overview Presentation

on

  • 2,205 views

Provides general information on Labconco's Precise Basic, Controlled Atmosphere and HEPA-Filtered Glove Boxes and XPert Weigh Box Glove Boxes. Answers basic questions and discusses the features and ...

Provides general information on Labconco's Precise Basic, Controlled Atmosphere and HEPA-Filtered Glove Boxes and XPert Weigh Box Glove Boxes. Answers basic questions and discusses the features and benefits of Precise Glove Boxes. Also addresses accessories available and market applications for Precise Glove Boxes.

Statistics

Views

Total Views
2,205
Views on SlideShare
2,203
Embed Views
2

Actions

Likes
0
Downloads
10
Comments
0

1 Embed 2

http://www.slideshare.net 2

Accessibility

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

Precise Glove Box Overview Presentation Precise Glove Box Overview Presentation Presentation Transcript

  • Labconco Precise™ Glove Boxes Product Overview   Basic   Controlled Atmosphere   HEPA-Filtered   XPert® Weigh Box
  • COPYRIGHT NOTICE The material included in this presentation is copyright of Labconco Corporation. Reproduction or use of the slides is not permitted without express permission from Labconco Corporation.
  • Labconco Precise™ Glove Boxes What are Glove Boxes? Glove Boxes provide a total physical barrier to the internal work area. Depending on the type of glove box, the physical barrier may:   Protect sensitive material inside from the outside contamination (chemicals or particulates)   Protect operators from hazards inside (chemicals or particulates)   Or both
  • Labconco Precise™ Glove Boxes Types of Precise Glove Boxes, which to choose?   Controlled Atmosphere Glove Boxes   Creates an inert gas atmosphere   Oxygen and moisture levels are reduced   Using compressed Nitrogen or Argon, O2/H20 levels can be reduced to a specific level (ex. 1% or 0.0001%) Example application-high-purity metals and anhydrous chemicals   HEPA Filtered Glove Boxes   Main chamber air volume is vented like a fume hood   All air entering and leaving is HEPA filtered (Air chemistry is not controlled) Example Application-Potent/toxic drug compounds
  • Labconco Precise™ Glove Boxes Precise™ Glove Boxes - Standard Features   One-piece molded,   13 cubic feet of interior space polyethylene shell   Transfer chamber11.0" ID x   Laminated safety glass 12.0″ window, removable for loading   No leaks greater than 1 x 10-3 equipment ml/sec, while pressurized with   Inner and outer transfer helium at 5” inches of water chamber doors, pivot upward gauge   Black, chemical resistant work   22 watt Fluorescent lamp surface   Transfer chamber shelf   Ceiling-mounted electrical   Neoprene gloves, 0.15" thick, duplex outlet (115 volt 5 amps) 30" long, size 9 3/4   ETL,UL and CE listed
  • Labconco Precise™ Glove Boxes Precise™ Glove Box models and part #   Precise Basic Glove Box #5220000   Sealed chambers, no valves   Precise Controlled Atmosphere Glove Box #5220100   Sealed chambers, with valves   Precise HEPA-Filtered Glove Box #5220200   Blower ventilated chamber with HEPA Filters   XPert Weigh Box #5220300   Blower ventilated chamber with HEPA Filters with anti-vibration, anti-static accessories included Precise Base Stand with Casters #5235500 Precise Base Stand w/o Casters #5235501
  • Labconco Precise™ Glove Boxes Precise™ Basic Glove Boxes   Basic Isolation Chamber   Laminated safety glass viewing window ¼" thick   Space-saving inner and outer transfer chamber doors   Black, chemical-resistant phenonlic core work surface   Interior ceiling-mounted electrical duplex receptacle   Neoprene gloves   Exterior fluorescent lamp   13 cubic feet of interior space
  • Labconco Precise™ Glove Boxes Precise™ Controlled Atmosphere Glove Boxes   Maintain inert gas atmospheres, using pressurized nitrogen or argon gas   Protect air-sensitive materials, i.e. inorganics, organics, biochemicals, organometallics   Reduces or eliminates chemical reactions with oxygen and moisture contamination
  • Labconco Precise™ Glove Boxes Precise™ Controlled Atmosphere   Entry level controlled atmosphere box   Can be accessorized to full electronic control levels   1% to 0.0050% or 10,000 to 50 ppm O2/ H2O   Options include O2/H2O removal and monitoring systems
  • Labconco Precise™ Glove Boxes Precise™ Controlled Atmosphere Connections   The transfer chamber is evacuated and refilled to zero pressure, with inert gas-this removes O2/H20 contaminants   The main chamber is evacuated and pressurized with inert gas repeatedly- this removes O2/H20 contaminants Glove Box Inlet Connection Glove Box Outlet Connection Transfer Chamber Inlet Connection Transfer Chamber Outlet Connection
  • Labconco Precise™ Glove Boxes Precise™ HEPA-Filtered Glove Boxes   Provides a physical barrier, protecting the operator or the product materials inside from exposure to dangerous particulates (ex. Hazardous solids vs. Clean Room applications)   Inlet air is HEPA filtered, creating an ISO Class 5 or Class 100 environment   Exhaust air is HEPA filtered removing particulates HEPA = High Efficiency Particulate Air Air cleanliness standards: Class 100 = 100 or less, particles at ≥ 0.5 um per cubic foot. ISO Class 5 Standard = 3,520 or less, particles at ≥ 0.5 um per cubic meter.
  • Labconco Precise™ Glove Boxes Precise™ HEPA-Filtered Glove Boxes   HEPA-filtered glove box - positive or negative pressure operation   Reduces chemical hazard risk levels   Ultra Clean Room application (positive pressure)   Superior filtered containment, tested to ISO #3 clean room standard   Built-in blower capable of 13 to 100 CFM
  • Labconco Precise™ Glove Boxes XPert® Weigh Box Glove Box   Superior filtered containment - tested to ISO #3 clean room standard   Anti-static ionizer fan to reduce static charge   Balance vibration isolator consisting of marble slab with isolator pads   Vibration less than 1.5 x 10-5 inches displacement measured at the work surface   Built-in blower capable of 13 to 100 CFM   Ultra Clean Room applications (positive pressure)
  • Labconco Precise™ Glove Boxes Precise HEPA/XPert Air Filtration Systems   Blower speed controller provides adjustable air flow volumes (CFM = cubic feet per minute).   Internal particulate levels reduced by dilution with HEPA filtered air, overtime. Dilution Rate = air flow volume ÷ chamber volume   HEPA intake filter   Exhaust HEPA filter   Blower   Accessory Recirculation kit
  • Labconco Precise™ Glove Boxes Precise™ Glove Boxes Size   Internal Main Chamber Dims: 34.5" w x 28.2" d x 25.7" h   Internal Transfer Chamber Dims: 11.25" dia x 12.7" L
  • Labconco Precise™ Glove Boxes Over 70 accessories to customize to your applications   Anti-static ionizer   Balance vibration kit   Drain and drain valve   Electrical outlet strips   RS 232 data port pass   Polycarbonate window   Airflow monitor   Storage shelves   IV bar kit   Glove port covers   Exhaust ductwork connection kit   Recirculation kit   Positive pressure kit
  • Labconco Precise™ Glove Boxes Precise™ Controlled Atmosphere Glove Box accessories   Oxygen/Moisture Trap   Oxygen/Moisture Stand   Circulating Pump   Automatic Pressure Controller   Tubing Connection Kits   Rotary Vane Vacuum Pump
  • Labconco Corporation 8811 Prospect Ave. Kansas City, MO 64132 1-800-821-5525 816-333-8811 www.labconco.com