Intertek emc capabilities
Upcoming SlideShare
Loading in...5
×
 

Intertek emc capabilities

on

  • 462 views

 

Statistics

Views

Total Views
462
Views on SlideShare
462
Embed Views
0

Actions

Likes
0
Downloads
1
Comments
0

0 Embeds 0

No embeds

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

    Intertek emc capabilities Intertek emc capabilities Presentation Transcript

    • Americas EMC Capabilities Semi-anechoic Emissions Test Frequency Range Electrical Power Location Chambers Sites (OATs) Load 3m 10m 30m 3m 10m 30m Emissions Immunity DC 50Hz 60Hz DC toBoxborough, 20Hz to 40GHz 0-30V 100A 230V, 400V 120/208/240V 100A Chambers - 4TMA █ █ █ 220GHz Up to 0-60V 50A 100A 277/480V 100A OATS – 2T 200 V/m 10kHz to 0-30 V, 120 A 20Hz to 18GHz 230 V, 50 A 120/208/240 V, 60 ADuluth, GA █ █ 40GHz Up to 0-60 V, 50 A 400 V, 50 A 480V, 60 A 4T 50V, 100A 20 V/m 20Hz toGrand Rapids, 20Hz to 18GHz 230 V, 16 A 120/208/240V 100AMI █a 40GHz Up to 0-400 V, 0-50A 400 V, 16 A 277/480V 100A 1T 200 V/m 10KHZ- 120/208/240/480V;Lake Forest, CA █ 9kHa-40GHz 2.7GHz 0-80VDC, 50A 230/400V, 50A 100/100/60/100A/per 4T Up to 3 V/m phase. 10 kHz – 0-48V, 170 A 20Hz – 18GHz 0-240 V 120/208/480 VLexington, KY █ █ 40GHz Up to 0-80 V, 25 A 12 kVA/phase 100 A/phase 4T 0-400 V, 2 A 10 V/m 30 Hz to 90 - 240V 90 - 240V 30Hz to 18GHzLouisville CO █ 40GHz Up to 0-50 V, 25A 100 A phase 100 A phase 1T 10 V/m 30 Hz – 480V, 208V, 20 Hz – 18 GHz 380V, 230V,Menlo Park, CA █ █ 40 GHz Up to 48V, 60A 60A 120V, 4T 60A 20 V/m 10 kHz- 120/208/240/480V; 18GHzOakdale, MN █ █ █ █ 9kHz-40GHz Up to 0-80VDC, 50A 230/380V, 100A 100/100/60/100A/per 8T phase. 10 V/m 10KHZ- 120/208/240/480V; 4GHzPlano, TX █ 9kHz-26GHz Up to 0-50VDC, 50A 230/380V, 100A 100/100/60/100A/per 2T phase. 10 V/m Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS) █ a. Grand Rapids also has a Reverb Chamber capable of immunity test levels up to 200 V/m +
    • Asia Pacific EMC Capabilities Emissions or Emissions Test Immunity Frequency Range Electrical Power Location Sites (OATs) Load Chambers 3m 10m 30m 3m 10m 30m Emissions Immunity DC 50Hz 60HzHong Kong █a █ 9k to 40 GHz 150k to 3GHz 24V 100-240V 100-240V x2 13A 13A 800kgShanghai (ETL 12–72V 100–240V 100–240VSEMKO) █ x2 9k to 26.5 GHz 150k to 3.2GHz 100A 25A 25A █ x3 █ x3 █ x2Kashima █ x2 █ 9k to 40 GHz 10k to 18GHz 100-240V/20kVA 100-240V/17kVA 10T █ █ █Matsuda █ x2 █ x5 █ x5 9k to 40GHz 10k to 18GHz 100-240V/15kVA 100-240V/15kVA 5T 80 toNagano █ █ x3 █ x3 9k to 40GHz 1000MHz 100-240V/6kVA 100-240V/6kVA 1TTochigi █ x3 █ x3 9k to 40GHz 100-240V/6kVA 100-240V/6kVA 5T █ x2 48V 100-240V 100-240VShenzhen 9k to 18GHz 150k to 3GHz 3A 1T 16A 16ATaiwan █ x2 9k to 40GHz 150k to 3GHz 12–48V 100–240V 110–230V 200kg 30A 25A 25A 2 shield rooms for conducted emissions, power disturbance, 0-240V single phase 0-120VGuangzhou magnetic emissions, and immunity tests 0-380V three phases single phase Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS) █ a. Full anechoic chamber used in Hong Kong for Immunity only
    • European EMC Capabilities Semi-anechoic Emissions Test Frequency Range Electrical Power Chambers Sites (OATs) Location Load 10 30 10 30 3m 3m Emissions Immunity DC 50Hz 60Hz m m m m 0-300VItaly 150kHz to 240V-22A 240V-22A █a █ █ 9kHz to 18GHz 4.2GHz 16A, 320V-16A 320V-16A 1T 0-80V 30A 0-135V, 37A 20 Hz to 26.5 10 kHz to 3Finland █ GHz GHz 0-120V, 13A 100 – 690V, 63A 4T 135 – 270V, 18A 0-440 V 9 kHz to 26.5 150 kHz to 4 0-150 V 0-440 VGermany █ x2 █ █ GHz GHz 50 A 130 A per phase 110A 2T per phase 20Hz to 10kHz to 0-54V 100-240V 100-240VSweden █ █ █ █ 40GHz 18GHz 200A 63A 16A 6T 20Hz to 20Hz to 0-100V 0-415V 0-110VUK █ 5m █ █ 40GHz 18GHz 200A 150A per phase 16A 3T Key █ Semi-anechoic chamber (emissions or immunity) █ Sheltered EMI site █ Open Area Test Site (OATS) █ a. Italy: full anechoic chamber