• Save
RSC Tornado based HPC solutions with Intel Xeon Phi Coprocessors and other Intel server products
Upcoming SlideShare
Loading in...5
×
 

RSC Tornado based HPC solutions with Intel Xeon Phi Coprocessors and other Intel server products

on

  • 395 views

A look at the first Intel Xeon Phi projects outside of the USA with RSC

A look at the first Intel Xeon Phi projects outside of the USA with RSC

Statistics

Views

Total Views
395
Views on SlideShare
394
Embed Views
1

Actions

Likes
0
Downloads
0
Comments
0

1 Embed 1

https://twitter.com 1

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

RSC Tornado based HPC solutions with Intel Xeon Phi Coprocessors and other Intel server products RSC Tornado based HPC solutions with Intel Xeon Phi Coprocessors and other Intel server products Presentation Transcript

  • 1* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Alexey ShmelevCOO, RSC Group, RussiaBooth #440 at ISC`13RSC Tornado liquid cooledHPC solutionswith Intel® Xeon Phi™and other Intel server productsFirst Intel Xeon Phi projects outside of the USA18th June, 2013
  • 2* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Outline• Mission and Company Profile• Focus Activities• Top Projects• Intel Partnership• Market Recognition and Positioning• Summary
  • 3* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Mission and ProfileWe focused on achieving thenew levels in• Efficiency• Performance• Productivity• Usefulness• AvailabilityCreate innovative technologiesfor the world leading HPC and cloud systemsInnovative HPC system developer and system integrator• Founded in Jan, 2009 in Moscow, Russia.• In-house HPC server design with liquid cooling and software development• Leading HPC developer and solution provider in Russia/CIS,1st implementations in EMEA and outside of the USA
  • 4* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Marketing DifferentiatorGood awareness on the market• Direct liquid cooling with world leadingenergy efficiency – #1 in Russia by Green500• High computational efficiency – Intel® TurboBoost Technology all the time enabled• Ultra high density – 180+ TFLOPS/rack• Scalability – up to dozens PFLOPS• Reliability – no moving parts at all• Lowest TCO – up to 60% savings
  • 5* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Development of energy efficient clusterarchitecture: RSC Tornado• Project proven efficient liquid cooling• Based on industry standard off the shelf CPUsand server boards• Up to 128 x 2 socket server 80 x 80cm x 42U• Achieving the world leading cooling PUE (1.06)RSC BasIS – self developed HPC/Cloudsoftware stack based on standardcomponentsFocus Activities
  • 6* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.RSC Tornado 3rd Generation3rd generation of RSC Tornado architecture -with newest Intel® Xeon Phi™ coprocessor• Unique computing density:• 181 TFLOPS per rack or141 TFLOPS/м3• 3.8X higher than theprevious world recordfor х86 architectures• Two RSC’s projects with IntelXeon Phi in Russia out of 7systems worldwide at Top500 –first outside of the USAProduct demo at RSCbooth, SC12 (USA)November 12-15, 2012
  • 7* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.New breakthroughRSC Tornado computing nodes based on Intel® Xeon® E5-2690 withIntel® Xeon Phi™ coprocessors and liquid cooling• Record level performance – 2.5 TFLOPS per node• Fully integrated energy efficient solution• Used in JSCC, SUSU projects
  • 8* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.RSC Tornado Product LineElectricityPerformanceRSC DСmicro16-64 nodesRSC HPC/CloudManagementRSC DСmini64-256 nodesRSC Data CenterUp to PFLOPS
  • 9* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.RSC DCmicro• Fully functional Data Center• From 16 up to 64 RSC Tornado basedcomputing nodes• Includes all necessary infrastructure:– Cooling system;– Power supply system;– Communication network;– Management server.
  • 10* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.RSC DCmini• Fully functional Data Center• From 64 up to 256 RSC Tornadobased computing nodes• Includes all necessaryinfrastructure:– 1-2 racks;– Cooling system;– Power supply system;– Communication network;– Management server.Deployed at Roshydromet andMIPT (Russia)
  • 11* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.RSC Data Center up to PFLOPs• Fully functional Data Center• More than 256 RSC Tornado basedcomputing nodes• Includes all necessaryinfrastructure:– More than 2 racks;– Cooling system;– Power supply system;– Communication network;– Storage;– Management server.Deployed at JSCC RAS and SUSU (Russia)
  • 12* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.MVS-10P Supercomputer, JSCC RAS• Prototype for 10PFLOPS system• #2 in Russia/CIS by Top50 (April’13)• #59 in Top500 (Nov’12)• #30 in Green500 (Nov’12). #1 in Russia• 20 sq. m. data center• 523.8 TFLOPS Rpeak• 375.7 TFLOPS Rmax (LINPACK)• 1949.3 MFLOPS/WThe largest Intel® Xeon Phi™ based system outside the US to date
  • 13* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.MVS-10P Project Details• 207 nodes, each with:2 x Intel® Xeon® E5-2690 (8 cores, 2.9 GHz)2 x Intel® Xeon Phi™ coprocessor SE10X (61 cores)Intel® SSD 330Intel® S2600JF server board• Total RAM 3.2 TBDDR3-1600, low voltage green memory• Total disk storage: 24.8 TB• Interconnect: Infiniband FDR, 56 Gbps• Service network:two independent sensor and control networks
  • 14* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.South Ural State University• 192 Nodes:– 2х Intel® Xeon® X5680 3.33– Intel® Xeon Phi™ coprocessor SE10X– Intel® SSD 330• #4 in Russia/CIS by Top50 (April’13)• #170 in Top500 (Nov’12)• #40 in Green500 (Nov’12)• 236.7 TFLOPS Rpeak• 146.8 TFLOPS Rmax (LINPACK)• 995 MFLOPS/W
  • 15* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Other projects (RSC Tornado)South Ural State University (Chelyabinsk, Russia)• Peak performance — 117 TFLOPS• #8 in Top50 (Russia/CIS), #303 in Top500 (max — #87)• 5 racks based on Intel® Xeon® X5680 (3.33 GHz, 130 W)Roshydromet (Moscow, Russia)Russian Meteorology Service, 1 of 3 WW weather forecast centers• 35 TFLOPS in one rack, 96 nodes in 1.3 m3• First HPC project on Intel® Xeon® E5-2690 in Russia/CIS• Record-level PUE=1.057• Most efficient system in Тоp50 — 90% on LINPACK• #27 in Top50 (Russia/CIS)Moscow Institute of Physics and TechnologyMIPT, Moscow Region (Russia)• I-SCALARE Laboratory – dedicated to life-scienceapplications (biomedicine, etc.)• 83.5 TFLOPS in two racks, 224 nodes• #10 in Top50 (Russia/CIS)•
  • 16* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Intel Partnership• Business with Intel since 2009• Intel Technology Provider, Platinum level• Joint SKU design with EPSD in 2010-2012• Intel Award, 2010 – ‘Largest volume topbin sales in Russia/CIS’• Intel Award, 2010 – ‘Best Server SolutionBased on Intel® Xeon® Processors in Russiaand CIS’• Intel Award, 2011, IPS event – ‘Foroutstanding achievements in promotion IAin HPC area in Russia’• Intel Award, 2012, IPS event – ‘Forimplementing the 1st Intel EPSD-basedliquid-cooling solution in the HPC area inEMEA’• Intel Award, 2013, ISS event – ‘Forimplementing two unique, first in EMEAinstallations of Intel Xeon Phi-basedsupercomputer clusters appeared in Top500list’
  • 17* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Market Recognition• RSC Tornado architecture is leadingon the HPC market in Russia/CIS –press award «Breakthrough of theYear-2012» (LAN Magazine)• Customers achieve new levels ofapplication speed up and 2X reducingof expenses on electricity andmaintenance• 8.5+ Mln kW*h electricity saved inRussia by RSC’s customers since 2009
  • 18* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Jack Dongarra at RSC’s sites“Both SUSU and JSCC RAS are state of the art high performance computing centerswith competent staff running the highly ranked Top500 and Green500 powerful andenergy efficient supercomputers. The facilities both use RSC Tornado based systemswith innovative liquid cooling and newest Intel Xeon Phi coprocessors which provideimpressive high performance capabilities and energy efficient solutions to solve verydemanding science research and engineering problems.” – said Jack Dongarra.
  • 19* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Strong Market Position• Leading innovative HPC solution builder inRussia/CIS• RSC share - near 40% of all Russian systems inTop500• Two the most energy efficient systems in Russiaaccording to Green500• First two Intel Xeon Phi projects outside of USAso far (out of 7 in Top500 worldwide)• Key installations in Top50 (Russia/CIS) - 4systems with liquid cooling in Top10 (April’13)• Strong position with leading Russian universities(incl. the largest one)
  • 20* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.Great resultsRSC Group achieved great results as key HPCplayer in Russia/CIS and visible worldwide:• Building innovative HPC architecture• Good market adoption with demand growthRSC booth at SC12 (USA)November 12-15, 2012
  • 21* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.SummaryRSC Group is one of the key HPC playershaving:• Unique technology innovations andcustomer proven implementations• Good market adoption• Brand awareness on HPC market inRussia/CIS and worldwide• Clear strategy for business development
  • 22* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.ContactAlexey ShmelevRSC GroupRussia, Moscow36 Kutuzovsky avenue, bld. 23alexeysh@rsc-skif.ru
  • 23* Other names and brands may be claimed as the property of others. Copyright © 2009, Intel Corporation.www.rscgroup.ru