Locator Hiossen Simplified Version

823 views

Published on

If you are interested about taking the most comprehensive localized implant training course with hands-on & live surgeries then please give us call at 530.715.0050.

This course will fulfill a doctor's desire to learn implant dentistry with practical clinical information and techniques. Emphasis is placed on anatomic considerations, treatment planning, and prosthetic technique.

0 Comments
3 Likes
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total views
823
On SlideShare
0
From Embeds
0
Number of Embeds
11
Actions
Shares
0
Downloads
7
Comments
0
Likes
3
Embeds 0
No embeds

No notes for slide

Locator Hiossen Simplified Version

  1. 1. The Locator Attachment Male Abutment HIOSSEN Inc Assembly Training
  2. 2. Locator Attachment Advantages• Guide plane positioned• Pivots 9 degree• 1.5,3, 4 & 5lbs. Retention• 20 degree divergent angle correction• Dual Retentive element• Simplified Tooling• Easy Replacement element• 3 Year male attachment warrantee
  3. 3. Female Portion ofLocator Attachment
  4. 4. Male Portion ofLocator Attachment
  5. 5. Choice of Male Locator Retentive ElementsProcessing 5lbs 3lbs. 1.5lb. Angle 4lbs.
  6. 6. Guide Plane Positioned
  7. 7. Attachment Pivots Male Abutment up to 9 Degrees Assembly
  8. 8. 20 Degree Angle Correction Capabilities 4lbs.
  9. 9. Secondary RetentionMetal Housing MaleAttachment FemaleAbutment Main Retention Dual Retentive Element Implant
  10. 10. 3 Year Warrantee Male Attachment INSERTION AND EXTRACTION TEST OF RETENTION LOSS (CYCLES TO 0.5 POUNDS RETENTION) 60 55 50 45CYCLES IN THOUSANDS 40 35 30 25 20 15 10 5 0 LOCATOR at 0 Angle LOCATOR at 10 Angle LOCATOR at 15 Angle LOCATOR at 20 Angle w /White Nylon Male w /White Nylon Male w /Extended Range Male w /Extended Range Male (60,000 Cycles) (48,000 Cycles) (50,000 Cycles) (37,000 Cycles)
  11. 11. LocatorChairside Technique
  12. 12. Remove Healing Abutment
  13. 13. Seat Locator® Abutments
  14. 14. Hand Tighten With Locator® Tool
  15. 15. Torque Driver With Locator Driver Torque To 20 Ncm
  16. 16. Place White Block-Out Ring Over Abutment
  17. 17. Place Housing Over Abutment
  18. 18. Apply Bonding Agent To Receptor Sites
  19. 19. Dry Housings
  20. 20. Load Clear or Pink Light Cure Acrylic Gel Into Receptor Sites
  21. 21. Paint Triad VLC Bonding Agent Onto Housings, then Brush on Light-Cured Gel
  22. 22. Seat Denture &Confirm Proper Occlusion
  23. 23. Light Cure Facial Of Housings Patient Closes Lightly Into OcclusionCure incrementally (5 secs) to control heat generated
  24. 24. Light Cure Lingual Of Housingsincrementally to control heat generated
  25. 25. Remove Denture, Inspect For Voids Fill If Necessary
  26. 26. Final Cure – 1 minute

×