Your SlideShare is downloading. ×
0
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Autoclave
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Autoclave

1,937

Published on

Autoclave, types of autoclave, horizontal autoclave, vertical autoclave, vacuum type autoclave, pressure cooker type autoclave. their purpose, precaution, etc....

Autoclave, types of autoclave, horizontal autoclave, vertical autoclave, vacuum type autoclave, pressure cooker type autoclave. their purpose, precaution, etc....

0 Comments
2 Likes
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total Views
1,937
On Slideshare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
126
Comments
0
Likes
2
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Autoclave Presented By:- Himanshu Dev DMLT (2011) VIth Sem. VMMC & SJH
  • 2.  The autoclave is a piece of equipment used for sterilizing various requirements in the lab by wet sterilization method.  The name comes from Greek auto-, ultimately meaning self, and Latin clavis meaning key—a self-locking device.  The word sterilizing means the destruction of elimination of all forms of life (microbial, including spores) present in inanimate objects by means of physical, chemical or gaseous procedures. Autoclave
  • 3. Operation Principle  When water is heated in a closed container, saturated steam is produced under pressure.  According to Boyle’s Law, when volume of the steam, is kept constant, the temperature is directly proportional to pressure.  If the pressure is reduced it boils at a lower temperature. If the pressure rises, it boils at a greater temperature.  At 15 lbs pressure 1210 C temperature can be obtained.  Moist heat coagulates cell proteins of the microorganisms and thus kills all the living entities (including spores) in 15 to 20 minutes.  Hot saturated steam is efficient means of destroying micro- organisms, since it penetrates rapidly and gives up its latent heat as it condenses on the cooler objects.
  • 4. The process associated in achieving sterile conditions of inanimate objects are the following : • Cleaning • Decontamination • Inspection • Preparation and packing • Sterilization • Storage • Delivery of materials
  • 5. Purpose of the Autoclave In the laboratory, materials and objects are sterilized for the following purposes: 1. To prepare materials for bacteriological cell cultures (test tubes, pipettes, Petridishes, etc.) in order to avoid their contamination. 2. Prepare elements used for taking samples. (All must be in sterile conditions: needles, tubes, containers). 3. Sterilize contaminated material.
  • 6. Two Type of Autoclave 1. Horizontal or downward displacement autoclave. 2. Vacuum assisted autoclave.
  • 7. Horizontal or downward displacement autoclave  In a Downward displacement autoclave cold air escapes through the bottom of the chamber as steam displaces it from above.  The valves should never be obstructed and the chamber must not be overfilled in order for this system to function efficiently.
  • 8. Horizontal or downward displacement autoclave contd..  This type of autoclave is electrically operated and can be fully or semiautomatic.  The downward displacement autoclave sterilizer is also known as a gravity displacement unit.  It uses a heating element to heat up the water and produce steam.  The steam, which is lighter than air, forces the air inside the sterilization chamber to move downward.  Eventually the air moves out through the drain hole of the sterilization chamber.  Once the temperature in the chamber is sufficient, the hole is automatically closed and the sterilization process is started.
  • 9. Vaccum Assisted Autoclave ClosedClosed OpenOpen SteamSteam SteamSteam ClosedClosed OpenOpen SteamSteam SteamSteam OpenOpen SteamSteam SteamSteam A vacuum assisted autoclave pulls pressure from the chamber.
  • 10. • A vacuum autoclave is set up in a similar fashion to a negative pressure displacement unit in that there is a vacuum pump to remove air from the sterilization chamber and steam is created in a second, separate chamber or unit. The process begins by the vacuum removing the air, then a pulse of steam. This type of autoclave is suitable for all types of instruments and is very versatile. Vaccum Assisted Autoclave
  • 11. Heat Exchange Steam Generator Vaccum Pump
  • 12. MAIN COMPONENTS 1. Heating Elements 2. Temperature Controller 3. Pressure Sensor 4. Chamber 5. Door gasket 6. Solenoid valve 7. Water level Sensor 8. Steam generator 9. Vaccum pump
  • 13. Vacuum assisted or pre-vacuum autoclave • Air is evacuated rapidly from the sterilising chamber at the beginning of the cycle creating a vacuum, so steam penetration and sterilising occurs very rapidly. • A second vacuum cycle withdraws moisture after sterilisation , facilitating drying of the load. • Often, this autoclave is connected to a central boiler of steam. They have a large capacity and are fully automated and failsafe. • Modern, computerised autoclaves will abort the cycle if there is a malfunction.
  • 14. Vertical Pressure Cooker(Autoclave) • This cooker operates similarly to a household pressure cooker. It is commonly used in practice. The vertical pressure cooker has an air vent at the top which is manually closed after all the air has been evacuated. • This is a possible disadvantage as some air may remain trapped under the steam and therefore cause a lower temperature to be reached in this area. • As this is a manually operated steriliser, human error can influence the effectiveness of sterilisation. • There is also no automatic drying cycle, so items may be slightly damp at the end of the cycle. Ensure packs are fully dried before storing.
  • 15. Classification of Autoclaves • Type "N" & Type "B“ Each • Type "N" units do not use a vacuum to remove air from the sterilization chamber. Type "N" autoclaves are suitable for a specific type of load--for solid. • Type "B" units use a vacuum pump. Type "B" autoclaves can be used on wrapped and hollow instruments, which means a piece of equipment can be sterilized now for use later.
  • 16. MAIN COMPONENTS 1. Heating Elements 2. Temperature Controller 3. Pressure Sensor 4. Chamber 5. Door gasket 6. Solenoid valve 7. Water level Sensor
  • 17. Preparation of Material 1. Syringes and needles  Syringes are wrapped in gauze and needles are placed separately in small test tubes that are plugged.  A pad of nonabsorbent cotton is placed at the bottom of each tube to protect the tip of the needle. Syringes and needles are then placed in a metal tray, which is placed uncovered in the autoclave. 2. Glassware  Glassware such as specimen tubes, petri dishes, specimen collection bottles are wrapped in brown paper and are tied with string.  The Pasteur pipettes are placed in large tubes, which are then plugged.
  • 18. What can be Autoclaved? Surgical Instruments Glassware Plastic tubes and pipette tips Culture and stocks of infectious material Discarded Live and attenuated vaccine Media and solutions Waste
  • 19. Preventive Maintenances 1. Clean all the filters.(Water, Air ) 2. Fill the water level of feed tank up to maximum limit 3. Check that the manometers function as expected. 4. Check the accuracy of temperature reading. 5. Activate the safety valves manually to verify that they are operating well. 6. Conduct a general sterilization process write down pressure, temperature, required times for completing each phase of the cycle, put it on registration system. 7. Verify that it is functioning within tolerances defined by manufacturer 8. Check any abnormal sound in solenoids. 9. Clean the chamber and remove limescale if any, advice to use only distilled water. 10. Check the earth leakage current, protective earth.
  • 20. Limescale Limescale is the hard, off- white, chalky deposit found in kettles, hot- water boilers Add little amount of any acid heat the chamber. Deposited CaCO3 will be removed. Then rinse off with plenty of water.
  • 21. Autoclave: Performance Indicators(Quality Control How to know if autoclave is functioning correctly: Physical -They check instrument’s control parameters like temperature, time and pressure. Chemical -Heat sensitive autoclave tape - Not an indicator of successful sterilization, useful to keep track of autoclaved and unautoclaved items Biological - Tests ability of autoclave to sterilize effectively - Geoacillus stearothermophilus spore strips often used because they are resistant to steam sterilization.
  • 22. Precaution for Autoclave Users Eye Protection Lab Coat, Buttoned Closed-toed Shoes Heat-resistant Gloves

×