79

Published on

Talk “Advances in Electronic Systems Engineering” seminar, within the M.Sc. in Electronic Systems Engineering (MISE), to present the session on Energy Optimization in Data Centers. …

Talk “Advances in Electronic Systems Engineering” seminar, within the M.Sc. in Electronic Systems Engineering (MISE), to present the session on Energy Optimization in Data Centers.

Speech title: Energy efficiency beyond PUE: exploiting knowledge about application and resources

Abstract: The current techniques for data center energy optimization, based on efficiency metrics like PUE, pPUE, ERE, DCcE, etc., do not take into account the static and dynamic characteristics of the applications and resources (computing and cooling). However, the knowledge about the current state of the data center, the past history, the resource characteristics, and the characteristics of the jobs to be executed can be used very effectively to guide decision-making at all levels in the datacenter in order to minimize energy needs. For example, the allocation of jobs on the available machines, if done taking into account the most appropriate architecture for each job from the energetic point of view, and taking into account the type of jobs that will come later, can reduce energy needs by 30%.
Moreover, to achieve significant reductions in energy consumption of state-of-the-art data centers (low PUE) is becoming increasingly important a comprehensive and multi-level approach, ie, acting on different abstraction levels (scheduling and resource allocation, application, operating system, compilers and virtual machines, architecture, and technology), and at different scopes (chip, server, rack, room, and multi-room).

Date and Time: Tuesday, October 15, 2013, 16:00, room B-221

0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
79
On Slideshare
0
From Embeds
0
Number of Embeds
1
Actions
Shares
0
Downloads
3
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Eficiencia Energética más allá del PUE: Explotando el Conocimiento de la Aplicación y los Recursos José%M.%Moya%<jm.moya@upm.es>% Laboratorio%de%Sistemas%Integrados% Dpto.%Ingeniería%Electrónica% Universidad%Politécnica%de%Madrid% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 1%
  • 2. CAMPUS OF INTERNATIONAL EXCELLENCE Contenido “Ingeniamos el futuro”! •  MoLvación% •  Enfoque%actual% •  Nuestro%enfoque% –  Planificación%y%gesLón% de%recursos% –  OpLmización%de% máquinas%virtuales% –  GesLón%de%modos%de% bajo%consumo% –  Diseño%de%procesadores% •  Conclusiones% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 2%
  • 3. CAMPUS OF INTERNATIONAL EXCELLENCE Motivación “Ingeniamos el futuro”! •  Consumo%energéLco%en%data%centers% –  1.3%%de%la%producción%energéLca%mundial%en%2010% –  USA:%80%mill%MWh/año%en%2011%=%1,5%x%NYC% –  1%datacenter%medio%=%25%000%casas% •  Más%de%43%Millones%de%Toneladas%de%CO2%/%año% (2%%mundial)% •  Más%agua%que%la%industria%del%papel,%automóvil,% petróleo,%%madera%o%plásLco% %%%%%%%%%%Jonathan%Koomey.%2011.%Growth%in%Data%center%electricity%use%2005%to%2010% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 3%
  • 4. Motivación CAMPUS OF INTERNATIONAL EXCELLENCE •  El%consumo%de%energía%de%la% refrigeración%conLnuará% teniendo%una%importancia% similar%o%superior%al%consumo% de%la%computación% •  La%opLmización%energéLca% de%los%data%centers%del%futuro% requerirá%un%enfoque%global% y%mulLfdisciplinar.% 35000% 30000% 25000% Highfend%servers% 20000% 15000% Midfrange%servers% 10000% Volume%servers% 5000% 0% 2000% 2005% 2010% 5,75%Millones%de%servidores%nuevos%/%año% 10%%de%servidores%sin%uLlizar%(CO2%de%6,5% millones%de%coches)% 300% Electricity%use%% (billion%kWh/year)% •  Se%espera%que%la%electricidad% total%uLlizada%por%los%data% centers%en%2015%exceda%los% 400%GWh/año.% World%server%installed%base% (thousands)% “Ingeniamos el futuro”! Infrastructure% 250% CommunicaLons% 200% 150% Storage% 100% Highfend%servers% 50% Midfrange%servers% 0% 2000% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% Volume%servers% 2005% 2010% 4%
  • 5. CAMPUS OF INTERNATIONAL EXCELLENCE Problemas de fiabilidad que dependen de la temperatura “Ingeniamos el futuro”! ElectromigraLon%(EM)% ✔% ✖% Timefdependent% dielectricf breakdown%(TDDB)% Stress% migraLon%(SM)% ✖% ✖% Thermal% cycling%(TC)% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 5%
  • 6. CAMPUS OF INTERNATIONAL EXCELLENCE Refrigeración de un data center “Ingeniamos el futuro”! José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 6%
  • 7. (excluyendo el software) de los servidores. $$$$ En un centro de datos convencional, algunas de estas mejoras pueden reducir su impacto en Mejoras en servidores las ........................... CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Servidores 10% no se utilizan •  Virtualización% 5,75 millones de nuevos servido% res se instalan cada año para % mantenerse al ritmo de creci- siguientes cifras: Reducir un 27% el consumo f%27%% 27% miento de los servicios on-line, y •  Servidores%conforme%a% todavía aproximadamente el 10% de los servidores instalados no Energy%Star% se utilizan debido a sobrestima% ciones conservadoras a la hora % de planificar las necesidades de almacenamiento. •  Mejor%planificación%de% capacidad% los servidores en desuso podría compensar % La energía utilizada para las emisiones de 6,5 6,5 millones energético mediante la virtualización, lo que reduce la capacidad productiva no empleada. =%6.500% El equivalente a retirar 6.500 coches de las carreteras, mediante la utilización de servidores = 6.500 2.500% acordes a Energy Star, lo que reduciría el consumo eléctrico de los centros de datos en 82.000 megavatios-hora. El equivalente a la energía consumida por 2.500 hogares en EEUU, mediante una mejor planifica- UN%SOLO% ción de la capacidad. CENTRO% DE%DATOS% A menudo los servidores se sobredimensionan José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 7% millones de coches. para afrontar picos de demanda, lo que significa que como media suelen funcionar sólo al 20% 2.500 US
  • 8. CAMPUS OF INTERNATIONAL EXCELLENCE Mejoras en refrigeración “Ingeniamos el futuro”! •  Mejoras%en%gesLón%de%flujos%de%aire%y%rangos% de%temperatura%ligeramente%más%amplios% Reducción%del%consumo% hasta%un% 25%% 25.000% Recuperación%de%la%inversión%% UN%SOLO% CENTRO% DE%DATOS% 2%años% en%solo% % José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 8%
  • 9. CAMPUS OF INTERNATIONAL EXCELLENCE Mejoras en infraestructura “Ingeniamos el futuro”! CA%!%CC% – 20%%reducción%de%pérdidas%de%conversión% – 47%millones%de%dólares%de%gastos% inmobiliarios%por%data%center% – Mayor%eficiencia,%ahorro%de%energía%suficiente%para% cargar%un%iPad%durante % 70 millones%de%años% % José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 9%
  • 10. Mejores prácticas de
  • 11. CAMPUS OF INTERNATIONAL EXCELLENCE eficiencia energética “Ingeniamos el futuro”!
  • 12. José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 10%
  • 13. ot aisle Potencial de mejora con mejores prácticas CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Total power (computing and cooling) for various scheduling approaches max computing power, worst thermal placement min computing power, worst thermal placemenit optimal computing+cooling optimal computing+cooling, shut off idles optimal computing+cooling, shut off idles, no recirculation 1400 Power (KW) 1200 1000 savings by minimizing computing power savings by minimizing the recirculation’s effect savings by turning off idle machines unaddressed heat recirculation cost basic (unavoidable) cost 800 600 400 200 0 0 20 40 60 80 100 job size relative to data center capacity (%) José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 11% Fig. 3. Data center operation cost (in kilowatts) for various “savings modes”. Savings are based on heat recirculation data obtained by
  • 14. CAMPUS OF INTERNATIONAL EXCELLENCE PUE Power Usage Effectiveness “Ingeniamos el futuro”! 1 !!!#$ !!#$%!'( + !!#!$%!'$() + !!#$ !# = = = ! !#$ !! !!#$% •  Estado%del%arte:%%PUE%≈%1,2% –  La%parte%importante%es%el%consumo%de%computación% –  El%trabajo%en%eficiencia%energéLca%en%DC%está% centrado%en%la%reducción%del%PUE% –  Reducir%PIT$$no%reduce%el%PUE,%pero%se%nota%en%la% factura%de%la%luz% •  %¿Cómo%se%puede%reducir%PIT$?% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 12%
  • 15. CAMPUS OF INTERNATIONAL EXCELLENCE Ahorro energético según el nivel de abstracción “Ingeniamos el futuro”! José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 13%
  • 16. CAMPUS OF INTERNATIONAL EXCELLENCE Nuestro enfoque “Ingeniamos el futuro”! •  Estrategia%global%para%permiLr%la%uLlización%de% múlLples%fuentes%de%información%y%para%coordinar%las% decisiones%con%el%fin%de%reducir%el%consumo%total% •  ULlización%del%conocimiento%de%las%caracterísLcas%de% demanda%energéDca%de%las%aplicaciones%y%las% caracterísDcas%de%los%recursos%de%computación%y% refrigeración%para%aplicar%técnicas%proacDvas%de% opLmización% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 14%
  • 17. CAMPUS OF INTERNATIONAL EXCELLENCE Optimización proactiva “Ingeniamos el futuro”! Datacenter% OpLmizaLon% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% Model% 15%
  • 18. Optimización proactiva CAMPUS OF INTERNATIONAL EXCELLENCE Workload “Ingeniamos el futuro”! Communication network Anomaly Detection and Reputation Systems Dynamic Cooling Opt. Resource Alloc. Opt. Sensors Actuators Sensor configuration Sensor network Datacenter Workload Model Power Model Global DVFS Energy Model VM Opt. Thermal Model Visualization José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 16%
  • 19. CAMPUS OF INTERNATIONAL EXCELLENCE Sensores “Ingeniamos el futuro”! José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 17%
  • 20. Enfoque holístico CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Chip% Sched%%alloc% Server% Rack% Room% 2% 1% Compiler/VM% 3% 3% architecture% 4% MulDJ room% 4% app% OS/middleware% technology% 5% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 18%
  • 21. 1. Gestión de recursos en la sala CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Chip% Server% Rack% Room% 2% 1 Compiler/VM% 3% 3% architecture% 4% MulDJ room% 4% Sched%%alloc% app% OS/middleware% technology% 5% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 19%
  • 22. CAMPUS OF INTERNATIONAL EXCELLENCE Aprovechando la heterogeneidad “Ingeniamos el futuro”! CCGrid 2012 •  ULlización%de%la%heterogeneidad%para%minimizar%el% consumo%energéLco%desde%un%punto%de%vista% estáLco/dinámico% –  EstáDco:%Encontrar%el%mejor%setfup%del%datacenter,% dado%un%número%heterogéneo%de%máquinas% –  Dinámico:%OpLmización%de%la%asignación%de%tareas%en% el%Resource%Manager% •  Demostramos%que%la%mejor%solución%se%encuentra% en%un%datacenter%heterogéneo% –  Muchos%datacenters%son%heterogéneos%(diversas% generaciones%de%máquinas)% M.%Zapater,%J.M.%Moya,%J.L.%Ayala.%Leveraging%Heterogeneity%for% Energy%MinimizaLon%in%Data%Centers,%CCGrid%2012% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 20%
  • 23. Escenario actual CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! WORKLOAD% Scheduler% Resource%% Manager% ExecuDon% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 21%
  • 24. 18.41 hr 6.9 ms 6.2% 20.75 hr 213 ms 8.6% CAMPUS OF INTERNATIONAL EXCELLENCE FCFS-FF EDF-LRH 20 15 FCFS-FF EDF-LRH FCFS-Xint SCINT Energy consumption, Scenario (b) 120 jobs, 16039 core-hours, idle servers off 40 12.17 hr 397 ms 0.172 jobs/hr 4.1% 20.75 hr 213 ms 8.6% 8.98 hr 40.8 min 0.197 jobs/hr 3.6% 18.41 hr 23 min 8.7% 48.49 hr 88.6 min 0.163 jobs/hr 4.7% 51.75 hr 40 min 10.2% 150 100 100 35 30 energy consumed energy consumed (GJ) (GJ) 8.98 hr 186 ms 0.197 jobs/hr 1.7% 18.41 hr 6.9 ms 6.2% Energy consumption, Scenario (a) 40 jobs, 25014 core-hours, idle servers off cooling energy computing energy cooling energy computing energy 40 35 cooling energy 0.580 jobs/hr 0.580 jobs/hr 0.349 jobs/hr 0.580 jobs/hr energy computing 0.254 jobs/hr energy consumed energy consumed (GJ) (GJ) FCFS-LRH (b) computing energy 30 25 Throughput Turnaround time Throughput Alg. runtime time Turnaround Energy savings Alg. runtime Energy savings 0.580 jobs/hr 8.98 hr 0.197 jobs/hr 171 ms 18.41 hr 0% 3.4 ms 0.580 jobs/hr 8.98 hr 0.197 jobs/hr 186 ms 18.41 hr 4.0% 6.9 ms 0.349 jobs/hr 12.17 hr 0.172 jobs/hr 397 ms 20.75 hr 14.6% 213 ms 0.580 jobs/hr 8.98 hr 0.197 jobs/hr 42 minhr 18.41 14.2% 23 min 0.427 jobs/hr 17.75 jobs/hr 0.163 hr 100 min 38.02 hr 15.1% 43 min 0% 11.8% 54.7% 21.8% 60.5% FCFS-FF FCFS-LRH EDF-LRH FCFS-Xint SCINT FCFS-FF (d) FCFS-LRH EDF-LRH FCFS-Xint SCINT 25 20 20 15 15 10 10 5 50 50 5 0 0 FCFS-FF 0 FCFS-FF FCFS-LRH EDF-LRH FCFS-Xint SCINT FCFS-LRH EDF-LRH (c) FCFS-Xint SCINT 0 (a) Energy consumption, Scenario (c) 174 jobs, 45817 core-hours, idle servers on (b) Energy consumption, Scenario (c) 174 jobs, 45817 core-hours, idle servers off Energy consumption, Scenario (b) 120 jobs, 16039 core-hours, idle servers on cooling energy Energy consumption, Scenario (b) 120 jobs, 16039 core-hours, energy cooling idle servers off computing energy cooling energy computing energy 450 Throughput 100 0.892 jobs/hr 0.892 jobs/hr 0.861 jobs/hr 0.892 jobs/hr 0.561 jobs/hr 300 196 ms 8.98 hr 186 ms 2.5% 1.7% 346 ms 12.17 hr 397 ms 5.9% 4.1% 20 min 8.98 hr 40.8 min 9.4% 3.6% 142 min 48.49 hr 88.6 min 12.5% 4.7% 250 200 200 150 150 35 energy consumed energy consumed (GJ) (GJ) Alg. runtime time 173 ms Turnaround 8.98 hr 350 Alg. runtime Energy savings 170 ms 0% 0% 250 Energy savings computing energy cooling energy computing 0.590 jobs/hr 0.892 jobs/hr 0.892 jobs/hr 0.861 jobs/hr 0.892 jobs/hr energy 40 400 300 Turnaround time 9.99 hrjobs/hr 9.99 hrjobs/hr 13.39 hr Throughput 0.580 0.580 0.349 jobs/hr 9.99 hrjobs/hr 65.38 hr 0.580 0.254 jobs/hr energy consumed energy consumed (GJ) (GJ) 0.163 jobs/hr 38.02 hr 43 min 60.5% 0 SCINT cooling idle servers on Energy consumption, Scenario (a) 40 jobs, 25014 core-hours,energy 200 0.197 jobs/hr 18.41 hr 23 min 21.8% 25 Energy consumption, Scenario (b) 120 jobs, 16039 core-hours, idle servers on Alg. runtime 170 ms Throughput Energy savings 0.197 jobs/hr 0% Turnaround time 18.41 hr Alg. runtime 3.4 ms 0% 150 Energy savings 0.172 jobs/hr 20.75 hr 213 ms 54.7% iMPACT Lab (Arizona State U) FCFS-Xint (a) 250 0.197 jobs/hr 18.41 hr 6.9 ms 11.8% 5 FCFS-LRH 300 Throughput 200 Turnaround time 8.98 hr Throughput 0.197 jobs/hr Turnaround time 18.41 hr Alg. runtime 3.4 ms Energy savings 0% 30 10 0 “Ingeniamos el futuro”! 51.75 hr 40 min 10.2% Planificación y asignación de recursos consciente de la refrigeración 100 50 18.41 hr 23 min 8.7% energy consumed (GJ) energy consumed (GJ) 150 Turnaround time 18.41 hr Alg. runtime 3.4 ms Energy savings 0% 100 100 Throughput Turnaround time 9.99 hr Alg. runtime 173 ms Energy savings 0.580 jobs/hr 0.0% Throughput 9.99 hr 191 ms 7.5% 0.580 jobs/hr 13.39 hr 346 ms 17.3% 0.349 jobs/hr 9.99 hr 21 min 25.7% 0.580 jobs/hr 61.49 hr 147 min 41.4% 0.427 jobs/hr Alg. runtime Energy savings 8.98 hr 186 ms 4.0% 12.17 hr 397 ms 14.6% 8.98 hr 42 min 14.2% 17.75 hr 100 min 15.1% 80 30 Turnaround time 8.98 hr 25 60 171 ms 0% 20 40 15 10 20 50 50 5 0 0 FCFS-FF 0 FCFS-FF FCFS-LRH EDF-LRH FCFS-Xint SCINT FCFS-LRH EDF-LRH (e) FCFS-Xint SCINT 0 FCFS-FF FCFS-FF EDF-LRH FCFS-Xint SCINT FCFS-LRH EDF-LRH (f) FCFS-LRH FCFS-Xint SCINT (c) (d) Fig. 8. Energy comparison of the simulated schemes for the three scenarios. The plots correspond in respective positions to the plots of Figure 7. Energy consumption, Scenario (c) 174 jobs, 45817 core-hours, idle servers on Energy consumption, Scenario (c) 174 jobs, 45817 core-hours, idle servers off José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 22% energy computing 450 policy used in the data center, which enables job execution as soon as they arrive if the queue is empty and the data cooling energy computing energy 400 Throughput cooling energy 100 0.892 jobs/hr 0.892 jobs/hr 0.861 jobs/hr 0.892 jobs/hr 0.561 jobs/hr Throughput 0.892 jobs/hr 0.892 jobs/hr 0.861 jobs/hr 0.892 jobs/hr 0.590 jobs/hr Turnaround time 9.99 hr 9.99 hr 13.39 hr 9.99 hr 61.49 hr Alg. runtime 173 ms 191 ms 346 ms 21 min 147 min Energy savings 0.0% 7.5% 17.3% 25.7% 41.4% 350 300 Energy savings 0% 9.99 hr 13.39 hr 9.99 hr 65.38 hr 2.5% 5.9% 9.4% 12.5% (GJ) (GJ) center is lightly173 ms loaded. In the346 ms “idle-on” case (Figure 8a), the total energy consumption using SCINT, EDF-LRH, Alg. runtime 196 ms 20 min 142 min Turnaround time 9.99 hr 80
  • 25. CAMPUS OF INTERNATIONAL EXCELLENCE Planificación y asignación de recursos consciente de la aplicación LSI-UPM “Ingeniamos el futuro”! Resource%% Manager% (SLURM)% WORKLOAD% ExecuDon% Profiling%and% ClassificaDon% Energy%% OpDmizaDon% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 23%
  • 26. CAMPUS OF INTERNATIONAL EXCELLENCE Planificación y asignación de recursos consciente de la aplicación Escenario “Ingeniamos el futuro”! •  Workload:% –  12%tareas%del%benchmark%SpecCPU%2006% –  Workload%aleatorio%de%2000%tareas,%dividido%en%job%sets% –  Tiempo%de%llegada%aleatorio%entre%job%sets% •  Servidores:% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 24%
  • 27. CAMPUS OF INTERNATIONAL EXCELLENCE Planificación y asignación de recursos consciente de la aplicación Profiling de energía “Ingeniamos el futuro”! Resource%% Manager% (SLURM)% WORKLOAD% ExecuDon% Profiling%and% ClassificaDon% Energy%% OpDmizaDon% Energy%profiling% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 25%
  • 28. CAMPUS OF INTERNATIONAL EXCELLENCE Caracterización de la carga de trabajo “Ingeniamos el futuro”! José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 26%
  • 29. Trabajo realizado CAMPUS OF INTERNATIONAL EXCELLENCE Optimizaciones “Ingeniamos el futuro”! Resource%% Manager% (SLURM)% WORKLOAD% ExecuDon% Profiling%and% ClassificaDon% Energy%% OpDmizaDon% Energy%MinimizaDon:% • %MinimizaDon%subjected%to%constraints% • %MILP%problem%(solved%with%CPLEX)% • %StaDc%and%Dynamic% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 27%
  • 30. CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Planificación y asignación de recursos consciente de la aplicación Optimización estática •  Definición%del%datacenter%ópLmo% –  –  –  –  Dado%un%pool%de%100%máquinas%de%cada% 1%job%set%del%workload% El%opLmizador%escoge%los%mejores%servidores% Constraints%de%presupuesto%y%espacio% Mejor%solución:% • %40%Sparc% • %27%AMD% % Ahorros:% • %5%a%22%%en%energía% • %30%%Dempo% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 28%
  • 31. CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Planificación y asignación de recursos consciente de la aplicación Optimización dinámica •  Asignación%ópLma%del%workload% –  Uso%del%workload%completo%(2000%tareas)% –  El%algoritmo%encuentra%una%buena%asignación%(no%la%mejor)% en%términos%de%energía% –  Ejecución%del%algoritmo%en%runLme% Ahorros%del%24%% al%47%%en%energía% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 29%
  • 32. CAMPUS OF INTERNATIONAL EXCELLENCE Planificación y asignación de recursos consciente de la aplicación Conclusiones “Ingeniamos el futuro”! •  Primera%prueba%de%concepto%en%cuanto%a%ahorros% energéLcos%gracias%a%heterogeneidad% •  Solución%automáLca% •  La%solución%automáLca%de%procesadores%ofrece% notables%ahorros%energéLcos.% •  La%solución%puede%ser%fácilmente%implementable%en% un%entorno%real% –  Uso%del%Resource%Manager%SLURM% –  Workloads%y%servidores%más%realistas% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 30%
  • 33. 2. Gestión de recursos en el servidor CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Chip% Server% Rack% Room% 2 1% Compiler/VM% 3% 3% architecture% 4% MulDJ room% 4% Sched%%alloc% app% OS/middleware% technology% 5% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 31%
  • 34. CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Políticas de planificación y asignación de recursos en MPSoCs UCSD – System Energy Efficiency Lab A.%Coskun%,%T.%Rosing%,%K.%Whisnant%and%K.%Gross%%StaLc%and%dynamic%temperaturef aware%scheduling%for%mulLprocessor%SoCs,%%IEEE%Trans.%Very%Large%Scale%Integr.%Syst.,%% vol.%16,%%no.%9,%%pp.1127%f1140%2008%% Fig. Fig.Distribution of thermal hot spots, with with DPM (ILP). 3. 3. Distribution of thermal hot spots, DPM (ILP). Fig. Fig.Distribution of spatial gradients, with with DPM (ILP). 4. 4. Distribution of spatial gradients, DPM (ILP). A. Static Scheduling Techniques A. Static Scheduling Techniques hot hot spots. While Min-Th reduces the high spatial differentials spots. While Min-Th reduces the high spatial differentials We We next provide extensive comparison of the the ILP based above 15 we we observe a substantial increasethe the spatial next provide an an extensive comparison of ILP based above 15 C, C, observe a substantial increase in in spatial techniques. refer to to static approach as as Min-ThSp. gradients above C. C. In contrast, method achieves lower José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% our techniques. We We refer our our static approach Min-ThSp. gradients above 10 10 In contrast,32% our method achieves lower As discussed in Section we implemented the ILP for min- and more balanced temperature distribution in in die. As discussed in Section III, III, we implemented the ILP for min- and more balanced temperature distributionthe the die. In 5, we we show how the magnitudes of thermal cycles vary imizing thermal spots (Min-Th), energy balancing (Balimizing thermal hot hot spots (Min-Th), energy balancing (Bal- In Fig.Fig. 5, show how the magnitudes of thermal cycles vary En), and energy minimization (Min-En) to compare against with the scheduling method. We demonstrate the average per-
  • 35. CAMPUS OF INTERNATIONAL EXCELLENCE Planificación y asignación de recursos consciente de la aplicación “Ingeniamos el futuro”! •  La%caracterización%energéLca%de%las% aplicaciones%permite%la%definición%de%políLcas% proacLvas%de%planificación%y%asignación%de% recursos%que%minimizan%los%hotspots •  La%reducción%de%hotspots%permite%aumentar%la% temperatura%del%aire%de%los%sistemas%de% refrigeración% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 33%
  • 36. CAMPUS OF INTERNATIONAL EXCELLENCE 3. Máquina virtual consciente de la aplicación y los recursos “Ingeniamos el futuro”! Chip% Sched%%alloc% Server% Rack% Room% 2% 1% Compiler/VM% 3 3 architecture% 4% MulDJ room% 4% app% OS/middleware% technology% 5% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 34%
  • 37. CAMPUS OF INTERNATIONAL EXCELLENCE Compilación JIT en máquinas virtuales “Ingeniamos el futuro”! •  La%máquina%virtual% compila%(JIT)%la% aplicación%a%código% naLvo%por%eficiencia% •  El%opLmizador%es% genérico%y%orientado%a% la%opDmización%de% rendimiento% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 35%
  • 38. CAMPUS OF INTERNATIONAL EXCELLENCE Compilación JIT para reducción de energía “Ingeniamos el futuro”! Backfend% Frontfend% OpLmizador% Generador%de% código% •  Compilador%consciente%de%la%aplicación% –  Caracterización%de%aplicaciones%y%transformaciones% –  OpLmizador%dependiente%de%la%aplicación% –  Visión%global%de%la%carga%de%trabajo%del%data%center% •  OpLmizador%de%energía% –  En%la%actualidad,%los%compiladores%para%procesadores% de%altas%prestaciones%solo%opLmizan%rendimiento% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 36%
  • 39. CAMPUS OF INTERNATIONAL EXCELLENCE Potencial de ahorro desde el compilador (MPSoCs) “Ingeniamos el futuro”! T.%Simunic,%G.%de%Micheli,%L.%Benini,%and%M.%Hans.%“Source%code%opLmizaLon%and% profiling%of%energy%consumpLon%in%embedded%systems,”%InternaLonal%Symposium%on% System%Synthesis,%pages%193%–%199,%Sept.%2000% –  Reducción%de%un%77%%%de%energía%en%un% decodificador%MP3% FEI,%Y.,%RAVI,%S.,%RAGHUNATHAN,%A.,%AND%JHA,%N.%K.%2004.%EnergyfopLmizing%source% code%transformaLons%for%OSfdriven%embedded%so{ware.%In%Proceedings%of%the% InternaLonal%Conference%VLSI%Design.%261–266.% –  Hasta%el%37,9%%(media%23,8%)%de%ahorro% energéLco%en%programas%mulLproceso%sobre% Linux% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 37%
  • 40. 4. Gestión automática de frecuencia a nivel global CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Chip% Sched%%alloc% Server% Rack% Room% 2% 1% Compiler/VM% 3% 3% architecture% 4 MulDJ room% 4 app% OS/middleware% technology% 5% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 38%
  • 41. CAMPUS OF INTERNATIONAL EXCELLENCE DVFS – Dynamic Voltage and Frequency Scaling “Ingeniamos el futuro”! •  Al%decrementar%la%tensión%de%alimentación,%la% potencia%se%reduce%cuadráLcamente%(a% frecuencia%constante)% •  El%retardo%se%incrementa%solo%linealmente% •  La%frecuencia%máxima%también%se%decrementa% linealmente% •  Actualmente%los%modos%de%bajo%consumo%se% acLvan%por%inacLvidad%del%sistema%operaLvo% de%un%servidor% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 39%
  • 42. CAMPUS OF INTERNATIONAL EXCELLENCE DVFS a nivel de sala “Ingeniamos el futuro”! •  Para%minimizar%el%consumo%hay%que%minimizar% los%cambios%de%modo% •  Existen%algoritmos%ópLmos%para%un%conjunto% conocido%de%tareas%(YDS)% •  El%conocimiento%de%la%carga%de%trabajo% permite%planificar%los%modos%de%bajo%consumo% a%nivel%global%sin%pérdida%de%rendimiento% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 40%
  • 43. Paralelismo para ahorrar energía Use of Parallelism CAMPUS OF INTERNATIONAL EXCELLENCE “Ingeniamos el futuro”! Vdd fmax Swiss Federal Institute of Technology Vdd/2 fmax/2 9-17 José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% Vdd/2 fmax/2 Computer Engineering and Networks Laboratory 41%
  • 44. CAMPUS OF INTERNATIONAL EXCELLENCE Resultados de simulación “Ingeniamos el futuro”! José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 42%
  • 45. CAMPUS OF INTERNATIONAL EXCELLENCE 5. Emplazamiento de cores consciente de la temperatura “Ingeniamos el futuro”! Chip% Sched%%alloc% Server% Rack% 2% Room% MulDJ room% 1% app% OS/middleware% Compiler/VM% 3% architecture% technology% 4% 4% 5 José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 43%
  • 46. CAMPUS OF INTERNATIONAL EXCELLENCE Floorplanning consciente de la temperatura “Ingeniamos el futuro”! José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 44%
  • 47. Temperature Reductions Average MaxTemp reduction: 12 oC Potencial de ahorro Larger temperature reductions for benchmarks energético with higher maximum temperature por floorplaning CAMPUS OF INTERNATIONAL EXCELLENCE For many benchmarks, temperature reducions are “Ingeniamos el futuro”! Y.%Han,%I.%Koren,%and%C.%A.%Moritz.%Temperature%Aware%Floorplanning.%In%Proc.%of%the%% larger than 20 oC Second%Workshop%on%TemperaturefAware%Computer%Systems,%June%2005% original Maximum Temperature 140 modified 120 100 80 60 40 avg wupwise vpr vortex twolf perlbmk parser mgrid mesa mcf lucas gzip gcc gap fma3d facerec equake eon crafty bzip2 art apsi applu ammp 0 swim 20 –  Reducciones%de%temperatura%máxima%de%hasta%21oC% –  Media:%f12oC%en%temperatura%máxima% –  Mayor%reducción%en%los%casos%más%críLcos% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 45%
  • 48. CAMPUS OF INTERNATIONAL EXCELLENCE Floorplanning consciente de la temperatura en chips 3D “Ingeniamos el futuro”! •  El%circuito%integrado%3D%está%recibiendo% atención:% –  ↑%↑% %Escalado:%reduce%área%2D%equivalente% –  ↑%↑% %Rendimiento:%menor%longitud%de% comunicaciones% –  ↑ %Fiabilidad:%menor%cableado% % •  Desventaja:% –  Aumentan$drás3camente$los$picos$de$ temperatura$con$respecto$a$los$diseños$2D$ equivalentes$ José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 46%
  • 49. CAMPUS OF INTERNATIONAL EXCELLENCE Floorplanning consciente de la temperatura “Ingeniamos el futuro”! •  Reducción%de%hasta%30oC%por%capa%en%un%chip% 3D%de%4%capas%y%48%cores% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 47%
  • 50. CAMPUS OF INTERNATIONAL EXCELLENCE Y todavía hay más “Ingeniamos el futuro”! •  Smart%Grids% –  Consumir%cuando%nadie%consume% –  Reducir%el%consumo%cuando%todo%el%mundo% consume% •  Reducción%de%la%factura%de%luz% –  Coste%dependiente%del%horario% –  Coeficiente%de%energía%reacLva% –  Picos%de%consumo% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 48%
  • 51. CAMPUS OF INTERNATIONAL EXCELLENCE Conclusiones “Ingeniamos el futuro”! •  Reducir%el%PUE%no%es%lo%mismo%que%reducir%el%consumo% –  El%consumo%de%computación%es%dominante%en%data%centers% modernos% •  El%conocimiento%de%la%aplicación%y%de%los%recursos%puede% ser%uLlizado%para%establecer%políDcas%proacDvas%para% reducir%la%energía%total% –  A%todos%los%niveles% –  En%todos%los%ámbitos% –  Considerando%simultáneamente%computación%y%refrigeración% •  La%gesLón%adecuada%del%conocimiento%del%comportamiento% térmico%del%data%center%permite%reducir%los%problemas%de% fiabilidad% •  Reducir%el%consumo%total%no%es%lo%mismo%que%reducir%la% factura%de%la%luz% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 49%
  • 52. CAMPUS OF INTERNATIONAL EXCELLENCE Contacto “Ingeniamos el futuro”! José M. Moya Laboratorio de Sistemas Integrados +34%607%082%892% jm.moya@upm.es% % Gracias:% José%M.Moya%|%%Madrid,%15%de%octubre%de%2013% 50%

×