dataTaker   family
Data logger  - a general view
The  dataTaker   DT 50/500/600 Range
General features dataTaker DT 50/500/600 <ul><li>Stand   alone data acquisition and data logging </li></ul><ul><li>Suitabl...
General features dataTaker DT 50/500/600 <ul><li>RS232 host communications port, to 9600 baud </li></ul><ul><li>Real time ...
Data memory dataTaker DT 50/500/600 <ul><li>Memory </li></ul><ul><ul><li>All SRAM technology memory </li></ul></ul><ul><ul...
Powering dataTaker DT 50/500/600 <ul><li>Powered from 9  –  18 VAC, 11  –  24 VDC source </li></ul><ul><li>Powered from ma...
Display keypad dataTaker DT 50/500/600 <ul><li>Display/Keypad (optional on some models) </li></ul><ul><ul><li>2 line by 16...
Channels dataTaker DT 50/500/600 <ul><li>Analog channels </li></ul><ul><ul><li>number of channels depends on model </li></...
Channels dataTaker DT 50/500/600 <ul><li>Digital channels </li></ul><ul><ul><li>Inputs  - digital state and counting (10Hz...
dataTaker DT 50
dataTaker DT 50 <ul><li>5 differential / 10 single ended analog input channels </li></ul><ul><li>Solid state analog multip...
dataTaker DT 50 <ul><li>3 high speed counters, 1KHz, 65535 counts </li></ul><ul><li>Internal memory: battery backed, 13,65...
dataTaker DT 500/505/515
dataTaker DT 600/605/615
dataTaker DT 500/600  series <ul><li>6 loggers in the series </li></ul><ul><ul><li>dataTaker   DT500 </li></ul></ul><ul><u...
dataTaker DT 500/600  series <ul><li>10 differential / 30 single ended analog input channels </li></ul><ul><li>DT500 & DT6...
dataTaker DT 500/600  series <ul><li>3 high speed counters, 1KHz, 65535 counts </li></ul><ul><li>Internal memory: battery ...
Accessories dataTaker DT 50/500/600 <ul><li>Channel Expansion Module </li></ul><ul><li>10 differential / 30 single ended a...
Accessories dataTaker DT 50/500/600 <ul><li>Memory Cards </li></ul><ul><li>PC-Card/PCMCIA technology </li></ul><ul><ul><li...
Accessories dataTaker DT 50/500/600 <ul><li>Memory Card Reader </li></ul><ul><li>Reads data from memory cards (PCMCIA) </l...
Accessories dataTaker DT 50/500/600 <ul><li>Modem Manager </li></ul><ul><li>Stores alarm messages from data loggers, and d...
Accessories dataTaker DT 50/500/600 <ul><li>Enclosures </li></ul><ul><li>Portable enclosure - IP67 </li></ul><ul><li>Indus...
The  dataTaker  DT800
The  dataTaker   DT 800
General features dataTaker DT 800 <ul><li>Standalone data acquisition and data logging </li></ul><ul><li>Suitable for fixe...
General features dataTaker DT 800 <ul><li>50MHz PowerPC with communications co - processor </li></ul><ul><li>Operating sys...
Data memory dataTaker DT 800 <ul><li>Memory </li></ul><ul><ul><li>Internal memory:  2Mbyte SRAM, lithium backed </li></ul>...
Communications dataTaker DT 800 <ul><li>Serial Comms Port </li></ul><ul><ul><li>RS232 to 115K baud </li></ul></ul><ul><ul>...
Powering dataTaker DT 800 <ul><li>Powered from any 11 – 28 VDC source </li></ul><ul><li>Powered from mains via an adaptor ...
Channels dataTaker DT 800 <ul><li>12 analog channels, 4 terminals per channel </li></ul><ul><ul><li>24 unshared (different...
Channels dataTaker DT 800
Channels dataTaker DT 800 <ul><li>Analog channels support </li></ul><ul><ul><li>AC voltage, DC voltage range ±13V </li></u...
Channels dataTaker DT 800 <ul><li>Digital channels </li></ul><ul><ul><li>8 channels input/output and counting </li></ul></...
Channels dataTaker DT 800 <ul><li>1 serial data channel  </li></ul><ul><ul><li>RS232, RS422, RS485 and SDI-12 modes </li><...
Accessories dataTaker DT 800 <ul><li>Memory Cards </li></ul><ul><li>PC Card/PCMCIA standard, ATA FLASH technology </li></u...
Accessories dataTaker DT 800 <ul><li>Memory Card Reader </li></ul><ul><li>Read data from memory  </li></ul><ul><li>cards d...
Accessories dataTaker DT 800 <ul><li>Enclosures </li></ul><ul><li>Portable enclosure carry case, IP67 </li></ul><ul><li>Wa...
Comparison Chart
U ser interface <ul><li>Simple English like commands in ASCII </li></ul><ul><li>Data in printable ASCII text format </li><...
Host software <ul><li>Data Acquisition </li></ul><ul><ul><li>DeTransfer for Windows 98, 2000, XP </li></ul></ul><ul><ul><l...
R adio modems <ul><li>Spread spectrum transceivers, 915 - 928 MHz </li></ul><ul><li>1200 - 115,200 baud, up to 15 km line ...
R adio modems 3. Repeater mode where longer distance required, or line of sight not possible
GSM modems <ul><li>Program logger and retrieve data via cellular phone network </li></ul><ul><li>SMS messaging from data l...
Notes
Upcoming SlideShare
Loading in...5
×

2dataTaker data loggers.ppt

1,431

Published on

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
1,431
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
89
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

2dataTaker data loggers.ppt

  1. 1. dataTaker family
  2. 2. Data logger - a general view
  3. 3. The dataTaker DT 50/500/600 Range
  4. 4. General features dataTaker DT 50/500/600 <ul><li>Stand alone data acquisition and data logging </li></ul><ul><li>Suitable for fixed position and portable applications </li></ul><ul><li>Extensive signal conditioning and sensor support </li></ul><ul><li>Flexible channel sampling and functions </li></ul><ul><li>Up to 25Hz sampling rate </li></ul><ul><li>Real-time calculations and data manipulation </li></ul><ul><li>Acquired data returned real-time and/or logged </li></ul><ul><li>Alarms monitoring, direct or indirect actions </li></ul>
  5. 5. General features dataTaker DT 50/500/600 <ul><li>RS232 host communications port, to 9600 baud </li></ul><ul><li>Real time clock </li></ul><ul><li>Flash firmware. Upgrade over serial link or memory card Series 3 only. Earlier logger firmware upgrade by ROM change. </li></ul>
  6. 6. Data memory dataTaker DT 50/500/600 <ul><li>Memory </li></ul><ul><ul><li>All SRAM technology memory </li></ul></ul><ul><ul><li>Internal memory: 166,530 readings (Series 3) </li></ul></ul><ul><ul><li>Memory cards (PCMCIA): 1,392,300 readings (4Mbyte, Series 3 only) </li></ul></ul><ul><ul><li>Series 1 models require PCMCIA adaptor </li></ul></ul><ul><ul><li>Stack or circular buffer storage modes </li></ul></ul><ul><ul><li>Data stored in compressed binary format </li></ul></ul>
  7. 7. Powering dataTaker DT 50/500/600 <ul><li>Powered from 9 – 18 VAC, 11 – 24 VDC source </li></ul><ul><li>Powered from mains via an adaptor </li></ul><ul><li>Low power consumption </li></ul><ul><li>Intelligent low power mode for battery operation </li></ul><ul><li>Internal battery (except DT50) </li></ul><ul><ul><li>lead acid </li></ul></ul><ul><ul><li>used for backup or as primary power source </li></ul></ul><ul><ul><li>automatically recharged from external power </li></ul></ul>
  8. 8. Display keypad dataTaker DT 50/500/600 <ul><li>Display/Keypad (optional on some models) </li></ul><ul><ul><li>2 line by 16 character, alphanumeric display </li></ul></ul><ul><ul><li>view current readings, alarm states, logger status </li></ul></ul><ul><ul><li>user definable function keys </li></ul></ul>
  9. 9. Channels dataTaker DT 50/500/600 <ul><li>Analog channels </li></ul><ul><ul><li>number of channels depends on model </li></ul></ul><ul><ul><li>ADC 15 bit plus sign, resolve to 1 microvolt </li></ul></ul><ul><ul><li>25 samples per second sampling </li></ul></ul><ul><li>Signal types and sensors supported </li></ul><ul><ul><li>Fundamental - voltage, frequency </li></ul></ul><ul><ul><li>Derived - temperature, strain, bridges, current </li></ul></ul><ul><ul><li>User defined - user calibrations, calculations </li></ul></ul>
  10. 10. Channels dataTaker DT 50/500/600 <ul><li>Digital channels </li></ul><ul><ul><li>Inputs - digital state and counting (10Hz, 65535 counts) </li></ul></ul><ul><ul><li>Outputs - TTL/CMOS, Open collector </li></ul></ul><ul><li>High speed counter channels 1KHz, 65535 counts </li></ul>
  11. 11. dataTaker DT 50
  12. 12. dataTaker DT 50 <ul><li>5 differential / 10 single ended analog input channels </li></ul><ul><li>Solid state analog multiplexer, +/- 3.2 VDC range </li></ul><ul><li>ADC 15 bit + sign, 1 microvolt, 25 samples/sec </li></ul><ul><li>5 digital channels </li></ul><ul><ul><li>Inputs as digital state, TTL and contact closure </li></ul></ul><ul><ul><li>Inputs as counting, 10Hz, 65535 counts </li></ul></ul><ul><ul><li>Outputs as TTL Open collector, 30VDC 200mA </li></ul></ul>
  13. 13. dataTaker DT 50 <ul><li>3 high speed counters, 1KHz, 65535 counts </li></ul><ul><li>Internal memory: battery backed, 13,650 readings </li></ul><ul><li>Memory card: 1 Mbyte PCMCIA, 343,000 readings </li></ul><ul><li>External backup battery - not physically in logger chassis </li></ul><ul><li>Optional external display keypad </li></ul><ul><li>Cannot be expanded </li></ul>
  14. 14. dataTaker DT 500/505/515
  15. 15. dataTaker DT 600/605/615
  16. 16. dataTaker DT 500/600 series <ul><li>6 loggers in the series </li></ul><ul><ul><li>dataTaker DT500 </li></ul></ul><ul><ul><li>dataTaker DT 505 </li></ul></ul><ul><ul><li>dataTaker DT 600 </li></ul></ul><ul><ul><li>dataTaker DT 605 </li></ul></ul><ul><ul><li>GeoLogger DT515 </li></ul></ul><ul><ul><li>GeoLogger DT615 </li></ul></ul>
  17. 17. dataTaker DT 500/600 series <ul><li>10 differential / 30 single ended analog input channels </li></ul><ul><li>DT500 & DT600 </li></ul><ul><ul><li>Solid state analog multiplexer, +/- 3.2 VDC range </li></ul></ul><ul><li>DT505, DT605, DT515, DT615 </li></ul><ul><ul><li>Relay analog multiplexer, +/- 100 VDC range </li></ul></ul><ul><li>ADC 15 bit + sign, 1 microvolt, 25 samples/sec </li></ul><ul><li>4 digital channels </li></ul><ul><ul><li>Inputs as digital state, TTL and contact closure </li></ul></ul><ul><ul><li>Inputs as counting, 10Hz, 65535 counts </li></ul></ul><ul><ul><li>Outputs as TTL Open collector, 30VDC 200mA </li></ul></ul>
  18. 18. dataTaker DT 500/600 series <ul><li>3 high speed counters, 1KHz, 65535 counts </li></ul><ul><li>Internal memory: battery backed, 13,650 readings </li></ul><ul><li>Memory card: 1 Mbyte PCMCIA, 343,000 readings </li></ul><ul><li>DT600, DT605, DT615 : Integral display keypad </li></ul><ul><li>DT500, DT505, DT515 : Optional external display keypad </li></ul><ul><li>Optional channel expansion using 1 or 2 CEMs </li></ul><ul><li>Internal 1.2Ahr backup battery </li></ul>
  19. 19. Accessories dataTaker DT 50/500/600 <ul><li>Channel Expansion Module </li></ul><ul><li>10 differential / 30 single ended analog inputs </li></ul><ul><li>Relay multiplexer </li></ul><ul><li>20 digital state inputs </li></ul><ul><li>10 digital state outputs </li></ul><ul><ul><li>5 as open collector </li></ul></ul><ul><ul><li>5 as changeover relay </li></ul></ul><ul><li>Up to 2 modules per data logger </li></ul><ul><li>Not supported by dataTaker DT 50 </li></ul>
  20. 20. Accessories dataTaker DT 50/500/600 <ul><li>Memory Cards </li></ul><ul><li>PC-Card/PCMCIA technology </li></ul><ul><ul><li>P ersonal C omputer M emory C ard I nternational A ssociation </li></ul></ul><ul><li>4 Mbyte, store 1,392,300 readings </li></ul><ul><li>Stack or Circular buffer (overwrite) data storage modes </li></ul><ul><li>Can be removed or exchanged during data capture without data loss (data buffered in internal memory) </li></ul><ul><li>Provide </li></ul><ul><ul><li>memory expansion </li></ul></ul><ul><ul><li>data transfer </li></ul></ul>
  21. 21. Accessories dataTaker DT 50/500/600 <ul><li>Memory Card Reader </li></ul><ul><li>Reads data from memory cards (PCMCIA) </li></ul><ul><li>Transfers data at up to 115,200 baud as a binary image to a computer via the RS232 port </li></ul><ul><li>Host software converts image to ASCII data file </li></ul>
  22. 22. Accessories dataTaker DT 50/500/600 <ul><li>Modem Manager </li></ul><ul><li>Stores alarm messages from data loggers, and delivers these to a host computer, SMS, fax or pager </li></ul><ul><li>Supports PSTN, GSM, CDMA, radio and satellite modems </li></ul><ul><li>Manages powering of the </li></ul><ul><li>telemetry system </li></ul><ul><li>Leaves data logger free to continue data capture and alarm monitoring </li></ul>
  23. 23. Accessories dataTaker DT 50/500/600 <ul><li>Enclosures </li></ul><ul><li>Portable enclosure - IP67 </li></ul><ul><li>Industrial enclosures </li></ul><ul><ul><li>3 sizes, IP55 </li></ul></ul><ul><li>Panel Mount Display/Keypad </li></ul><ul><li>for DT50 , DT500 , DT505 , DT515 </li></ul><ul><li>surface mount, flush mount, enclosure door mount </li></ul>
  24. 24. The dataTaker DT800
  25. 25. The dataTaker DT 800
  26. 26. General features dataTaker DT 800 <ul><li>Standalone data acquisition and data logging </li></ul><ul><li>Suitable for fixed position and portable applications </li></ul><ul><li>Extensive signal conditioning and sensor support </li></ul><ul><li>Flexible channel sampling and functions </li></ul><ul><li>Up to 100 kHz sampling rate </li></ul><ul><li>Real-time calculations and data manipulation </li></ul><ul><li>Alarms monitoring, direct or indirect actions </li></ul><ul><li>Acquired data returned real-time and/or logged </li></ul>
  27. 27. General features dataTaker DT 800 <ul><li>50MHz PowerPC with communications co - processor </li></ul><ul><li>Operating system in 2Mbyte FLASH, is user upgradeable </li></ul><ul><li>Real time clock/calendar, lithium backed </li></ul>
  28. 28. Data memory dataTaker DT 800 <ul><li>Memory </li></ul><ul><ul><li>Internal memory: 2Mbyte SRAM, lithium backed </li></ul></ul><ul><ul><li>Memory cards (PCMCIA): 32 Gbyte, A TA FLASH, non-volatile </li></ul></ul><ul><li>Data is stored in a DOS compatible file system - memory cards can be read directly in a computer PC Card slot </li></ul><ul><li>Data stored as ASCII text in a fixed format </li></ul><ul><li>Data storage is approx 50,000 readings per Mbyte </li></ul><ul><li>Stack and circular buffer (overwrite) modes </li></ul>
  29. 29. Communications dataTaker DT 800 <ul><li>Serial Comms Port </li></ul><ul><ul><li>RS232 to 115K baud </li></ul></ul><ul><ul><li>XON/XOFF and hardware flow control </li></ul></ul><ul><ul><li>modem support for dial in/dial out </li></ul></ul><ul><li>Ethernet Port </li></ul><ul><ul><li>1 0BaseT topography, 10Mbit/sec </li></ul></ul><ul><ul><li>UDP and TCP/IP protocols </li></ul></ul>
  30. 30. Powering dataTaker DT 800 <ul><li>Powered from any 11 – 28 VDC source </li></ul><ul><li>Powered from mains via an adaptor </li></ul><ul><li>Low power consumption </li></ul><ul><li>Intelligent low power mode for battery operation </li></ul><ul><li>Internal battery, lead acid </li></ul><ul><ul><li>used for backup or as primary power source </li></ul></ul><ul><ul><li>automatically recharged from external power </li></ul></ul><ul><li>System protection battery, lithium </li></ul><ul><ul><li>protects program, data log, alarm log and real time clock/calendar </li></ul></ul>
  31. 31. Channels dataTaker DT 800 <ul><li>12 analog channels, 4 terminals per channel </li></ul><ul><ul><li>24 unshared (differential) inputs </li></ul></ul><ul><ul><li>or 42 shared (single ended) inputs </li></ul></ul><ul><li>16 digital channels </li></ul><ul><ul><li>8 channels input/output and counting </li></ul></ul><ul><ul><li>8 channels input and counting </li></ul></ul><ul><li>1 serial data channel </li></ul><ul><li>1 analog output channel </li></ul>
  32. 32. Channels dataTaker DT 800
  33. 33. Channels dataTaker DT 800 <ul><li>Analog channels support </li></ul><ul><ul><li>AC voltage, DC voltage range ±13V </li></ul></ul><ul><ul><li>AC current, DC current range depends on shunt </li></ul></ul><ul><ul><li>resistance range 0 - 100KOhm </li></ul></ul><ul><ul><li>frequency range 0 - 20KHz </li></ul></ul><ul><ul><li>temperature sensors </li></ul></ul><ul><ul><ul><li>thermocouples, RTDs (platinum, nickel, copper) thermistors, solid state temperature sensors </li></ul></ul></ul><ul><ul><li>bridges, strain gauges </li></ul></ul><ul><li>Sufficient flexibility to support almost any sensor </li></ul>
  34. 34. Channels dataTaker DT 800 <ul><li>Digital channels </li></ul><ul><ul><li>8 channels input/output and counting </li></ul></ul><ul><ul><li>8 channels input and counting </li></ul></ul><ul><li>Digital channels support </li></ul><ul><ul><li>Inputs - digital state and counting (32 bit counters) </li></ul></ul><ul><ul><li>Outputs - TTL/CMOS, Open collector </li></ul></ul>
  35. 35. Channels dataTaker DT 800 <ul><li>1 serial data channel </li></ul><ul><ul><li>RS232, RS422, RS485 and SDI-12 modes </li></ul></ul><ul><ul><li>read serial data in from intelligent sensors, barcode scanners, keypads, PLCs, etc </li></ul></ul><ul><ul><li>send serial text to printers, display panels, PLCs, other data loggers, intelligent devices, etc </li></ul></ul><ul><li>1 analog output channel </li></ul><ul><ul><li>output voltage range – 10VDC to +10VDC @ 20mA </li></ul></ul><ul><ul><li>resolution 12 bit or 10mV </li></ul></ul><ul><ul><li>retransmit data to indicators, controllers, PLCs </li></ul></ul><ul><ul><li>proportional control of analog actuators </li></ul></ul>
  36. 36. Accessories dataTaker DT 800 <ul><li>Memory Cards </li></ul><ul><li>PC Card/PCMCIA standard, ATA FLASH technology </li></ul><ul><li>50,000 data points stored/Mbyte </li></ul><ul><li>Can be removed or exchanged during data capture without data loss (data buffered in internal memory) </li></ul><ul><li>Provide </li></ul><ul><ul><li>memory expansion </li></ul></ul><ul><ul><li>data transfer </li></ul></ul><ul><ul><li>program transfer </li></ul></ul>
  37. 37. Accessories dataTaker DT 800 <ul><li>Memory Card Reader </li></ul><ul><li>Read data from memory </li></ul><ul><li>cards directly into a </li></ul><ul><li>computer </li></ul><ul><li>USB or parallel port </li></ul><ul><li>Use with desktop PCs, Windows </li></ul><ul><li>OS. 98, 2000, XP </li></ul><ul><li>Notebooks usually have a PC Card s lot </li></ul>
  38. 38. Accessories dataTaker DT 800 <ul><li>Enclosures </li></ul><ul><li>Portable enclosure carry case, IP67 </li></ul><ul><li>Wall mounting industrial enclosures, IP65 </li></ul>
  39. 39. Comparison Chart
  40. 40. U ser interface <ul><li>Simple English like commands in ASCII </li></ul><ul><li>Data in printable ASCII text format </li></ul><ul><li>Compatible with all computers and terminals </li></ul><ul><li>Compatible with many applications programs </li></ul><ul><li>Compatible with all languages - VBasic, C, Delphi, LabVIEW </li></ul>
  41. 41. Host software <ul><li>Data Acquisition </li></ul><ul><ul><li>DeTransfer for Windows 98, 2000, XP </li></ul></ul><ul><ul><li>DePlot (OLE client to DeTransfer) </li></ul></ul><ul><ul><li>DeLoad </li></ul></ul><ul><ul><li>DeLogger 4 and DeLogger Pro 4 </li></ul></ul><ul><ul><li>Any Terminal Emulator / Comms Package </li></ul></ul><ul><li>Analysis and Presentation </li></ul><ul><ul><li>DeLogger 4 and DeLogger Pro 4 </li></ul></ul><ul><ul><li>Spreadsheets - Excel </li></ul></ul><ul><ul><li>Databases - Access etc. </li></ul></ul><ul><ul><li>Purpose Written - Visual Basic, C, LabVIEW </li></ul></ul>
  42. 42. R adio modems <ul><li>Spread spectrum transceivers, 915 - 928 MHz </li></ul><ul><li>1200 - 115,200 baud, up to 15 km line of sight </li></ul>1. Point to point 2. Point to multipoint, where host modem communicates with all or nominated remotes
  43. 43. R adio modems 3. Repeater mode where longer distance required, or line of sight not possible
  44. 44. GSM modems <ul><li>Program logger and retrieve data via cellular phone network </li></ul><ul><li>SMS messaging from data logger to cell phone of alarms, data, status, etc. </li></ul><ul><li>SMS messaging to logger for current readings, status, etc. </li></ul>