Fs23 a   installation - cable coating middle east, fire coating, cable coating
Upcoming SlideShare
Loading in...5
×
 

Fs23 a installation - cable coating middle east, fire coating, cable coating

on

  • 124 views

Steel Fire Protection and Solvent-Based Intumescent Coatings for Interior and Exterior Structural Steel. Fire Security Systems providing cost effective Steel Fire Protection, Intumescent Coatings, ...

Steel Fire Protection and Solvent-Based Intumescent Coatings for Interior and Exterior Structural Steel. Fire Security Systems providing cost effective Steel Fire Protection, Intumescent Coatings, Fire Coating, Fireproofing Spray, Fireproofing, Fire Stopping, Cable Coating and Fire Protection Products worldwide like Middle East, USA, Canada, Africa, , Bahrain, Saudi Arabia, Turkmenistan, Malaysia, Indonesia, UAE

Statistics

Views

Total Views
124
Views on SlideShare
123
Embed Views
1

Actions

Likes
0
Downloads
0
Comments
0

1 Embed 1

http://meem.greyshare.com 1

Accessibility

Categories

Upload Details

Uploaded via as Adobe PDF

Usage Rights

© All Rights Reserved

Report content

Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
  • Full Name Full Name Comment goes here.
    Are you sure you want to
    Your message goes here
    Processing…
Post Comment
Edit your comment

Fs23 a   installation - cable coating middle east, fire coating, cable coating Fs23 a installation - cable coating middle east, fire coating, cable coating Document Transcript

  • Page 1 of 1 FS23A Intumescent Sealant Installation Instructions FS23A Intumescent Sealant provides up to 4 hour fire rating and an effective acoustic and air tight seal in low movement joints. It can be used in gaps of up to 30mm in block walls, partitions and door frames and for annular gaps of up to 12.5mm wide with service penetrations in walls and floors. Installation 1) Do not apply the sealant when site temperatures are below 5°C or above 30°C as adhesion will be impaired. 2) Remove all loose debris, oil and grease from the joint. Ensure the joint is clean and dry. 3) Mask the adjacent surfaces to the joint. 4) Ensure that the joint is filled using an appropriate backing material for the fire rating required (see technical data sheet for details). The backing material aids better adhesion to the substrate. 5) Evenly apply the sealant in 12.5mm high sweeps. Larger gaps may need to be built up in several applications. 6) Tool off to a smooth finish. 7) Remove masking. 8) Clean off tools with water. 9) Water based paints can be applied after the sealant has fully cured through. This is dependant on site temperatures and the depth of the bead. Please consult technical sales office for curing times. Health & Safety Instructions General: FS23A Intumescent Sealant is a high specification, one part water based acrylic sealant. Eye Contact: The product may cause irritation or inflammation. Goggles should be worn to minimise exposure to the product. If the product enters the eyes, hold the eyelids apart and irrigate with clean fresh water. Skin Contact: The product may cause irritation to sensitive skins. Protective overalls and gloves should be worn to minimise exposure. If irritation occurs then wash the affected area thoroughly with soap and water. Other Information The information is current as of March 2013. Please contact Fire Security for updates. Fire Security AS | Skibåsen 20b -4636 Kristiansand Norway T: +47 95 47 80 00 ‫׀‬ F: +47 38 02 15 31 ‫׀‬ Web: www.fire-security.net ‫׀‬ Email: mail@fire-security.net