1 ks msds wood fire protection korea, fire protection products, cable coating in the usa

444 views
278 views

Published on

wood fire protection - fireproofing spray | fire coating | fire protection products | fire stop | fire coating in usa, middle east, canada, bahrain, turkmenistan, indonesia, uae

fire coating in usa,fire coating in middle east,fire coating in canada,fire coating in bahrain,fire coating in turkmenistan,fire coating in indonesia,fire coating in uae

Published in: Business, Technology
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
444
On SlideShare
0
From Embeds
0
Number of Embeds
2
Actions
Shares
0
Downloads
2
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

1 ks msds wood fire protection korea, fire protection products, cable coating in the usa

  1. 1. Safety Data Sheet 91/155/EEC (gb) Hensotherm 1KS für Holz Rudolf Hensel GmbH Revised: 02.06.2006 Date printed: 02.06.2006 01 Identification of the substance / preparation and of the company Product: Hensotherm 1KS für Holz Use: Intumescent fire retardant coatings Company: Rudolf Hensel GmbH Lauenburger Landstr. 11 21039 Börnsen +49 (0)40-72 10 62 10 Phone: info@rudolf-hensel.de eMail: +49 (0)40-72 10 62 10 Emergency phone: 02 Composition / Information on ingredients Substance EINECS/ELINCS CAS Range [%] Talcum 238-877-9 Fax: +49 (0)40-72 10 62 52 Homepage: www.rudolf-hensel.de 1 - < 10 14807-96-6 Symbol / R-phr. 03 Hazards identification No special hazards have to be mentioned. 04 First aid measures Change soaked clothing. General information Ensure supply of fresh air. In the event of symptoms refer for medical Inhalation treatment. When in contact with the skin, clean with soap and water. Consult a doctor Skin contact if skin irritation persists. In case of contact with eyes rinse thoroughly with plenty of water and seek Eye contact medical advice. Do not induce vomiting. Rinse out mouth and give plenty of water to drink. Ingestion Supply with medical care. Treat symptomatically. Advice to doctor 05 Fire-fighting measures Suitable extinguishing media Product itself is non-combustible, fire extinguishing method of surrounding areas must be considered. Full water jet. Extinguishing media that must not be used Risk of formation of toxic pyrolysis products. Special exposure hazards arising from the substance or preparation itself or combustion products Special protective equipment Use self-contained breathing apparatus. for firefighters Fire residues and contaminated firefighting water must be disposed of in Additional information accordance with the local regulations. rhh00010 gb_gb www.chemiebuero.de Tel. +49(0)941-566-398(-792) Fax. +49(0)941-566-994 eMail: info@chemiebuero.de Page 1 of 5
  2. 2. Safety Data Sheet 91/155/EEC (gb) Hensotherm 1KS für Holz Rudolf Hensel GmbH Revised: 02.06.2006 Date printed: 02.06.2006 06 Accidental release measures High risk of slipping due to leakage/spillage of product. Personal precautions Do not discharge into the drains/ surface waters/ groundwater. Prevent Environmental precautions spread over a wide area (e.g. by containment or oil barriers). Pick up with absorbent material (e.g. sand, sawdust, general-purpose Methods for cleaning binder, kieselguhr). Dispose of absorbed material in accordance with the up/taking up regulations. 07 Handling and storage Advice on safe handling Advice on protection against fire and explosion Requirements for storage rooms and vessels Advice on storage compatibility Further information on storage conditions No special measures necessary if used correctly. No special measures necessary. Keep only in original container. Not applicable. Keep container tightly closed. 08 Exposure controls / personal protection Additional advice on system design Ensure adequate ventilation on workstation. Ingredients with occupational exposure limits to be monitored: (gb) Substance Talcum [ppm]* [mg/m³]* 1 General remarks respirable dust, 14/3 * LTEL: Long-term exposure limit Respiratory protection Hand protection Eye protection Skin protection General protective measures Hygiene measures Delimitation and monitoring of the environmental exposition Not applicable. Butyl rubber, >480 min (EN 374) Safety glasses. Not applicable. Avoid contact with eyes and skin. Wash hands before breaks and after work. Use barrier skin cream. Not determinated. rhh00010 gb_gb www.chemiebuero.de Tel. +49(0)941-566-398(-792) Fax. +49(0)941-566-994 eMail: info@chemiebuero.de Page 2 of 5
  3. 3. Safety Data Sheet 91/155/EEC (gb) Hensotherm 1KS für Holz Rudolf Hensel GmbH Revised: 02.06.2006 Date printed: 02.06.2006 09 Physical and chemical properties Liquid. Form: White. Colour: Characteristic. Odour: 4-5,5 pH-value: Not determinated. pH-value, 1% Boiling point [°C]: Flash point [°C]: Not determinated. >100 Flammability: Lower explosion limit: Upper explosion limit: Not applicable. Not applicable. Not applicable. Combustible properties: No. 10 Stability and reactivity Hazardous reactions Hazardous decomposition products Vapour pressure [kPa]: Density [g/ml]: Bulk density [kg/m³]: Solubility in water: Partition coefficient: noctanol / water: Viscosity: Relative vapour density determined in air: Evaporation speed: Melting point [°C]: Autoignition temperature [°C]: Decomposition temperature [°C]: 2,3 1,28 Not applicable. Miscible. Not determinated. ca. 20+/-5d.Pas Not applicable. Not applicable. Not determinated. Not applicable. Not determinated. Reactions with strong oxidizing agents. No hazardous decomposition products known. 11 Toxicological information Acute oral toxicity OECD 401 Experiences made in practice General remarks Not determinated. None. No toxicological data are available. No classification on the basis of the calculation procedure of the preparation directive. 12 Ecological information AOX-advice 76/464/EC General information Not applicable. Not applicable. Ecological data are not available. 13 Disposal considerations Disposal / Product Waste no. (recommended) Disposal / Contaminated packaging For recycling, consult manufacturer. 080112 Uncontaminated packaging may be taken for recycling. Packaging that cannot be cleaned should be disposed of as for product. rhh00010 gb_gb www.chemiebuero.de Tel. +49(0)941-566-398(-792) Fax. +49(0)941-566-994 eMail: info@chemiebuero.de Page 3 of 5
  4. 4. Safety Data Sheet 91/155/EEC (gb) Hensotherm 1KS für Holz Rudolf Hensel GmbH Revised: 02.06.2006 Date printed: 02.06.2006 14 Transport information Classification according to ADR: Declaration: Labelling: Factor, ADR 1.1.3.6: LQ, ADR 3.4.6: Hazard-no: Label: Vapour pressure [kPa]: Classification according to IMDG: Declaration: Labelling: Label: LQ, [l, kg]: EmS: Classification according to IATA: Declaration: Labelling: Label: no dangerous goods 2,3 not classified as Dangerous Goods not classified as Dangerous Goods 15 Regulatory information Labelling: The product does not require a hazard warning label in accordance with EC directives Hazard symbols 15.1 Special labelling for certain preparations Safety data sheet available for professional user on request. 15.2 Sources of documentation EEC: 91/155 (2001/58); 67/548 (2004/73), 29. ATP; 1999/45 (2001/60); 91/689 (2001/118); 89/542; 1999/13; 2004/42 Transport information: ADR (2005); IMDG-Code (32.Amdt.); IATA-DGR (2006) 15.3 National regulations(gb) EH40/2002 Occupational Exposure Limits Supplemet 2003 16 Other informations (Information on ingredients - Position 02) Not applicable. 16.1 Additional information Observe employment restrictions for people No. Not applicable. VOC, 1999/13/EG Not determinated. Customs Tariff 16.2 Information on ingredients rhh00010 gb_gb www.chemiebuero.de Tel. +49(0)941-566-398(-792) Fax. +49(0)941-566-994 eMail: info@chemiebuero.de Page 4 of 5
  5. 5. Safety Data Sheet 91/155/EEC (gb) Hensotherm 1KS für Holz Rudolf Hensel GmbH Revised: 02.06.2006 UBA-Registration 648/2004/EG, contains: 2004/42/EG 16.3 Modified position: None. Date printed: 02.06.2006 Not applicable. Not applicable. Not applicable. rhh00010 gb_gb www.chemiebuero.de Tel. +49(0)941-566-398(-792) Fax. +49(0)941-566-994 eMail: info@chemiebuero.de Page 5 of 5

×