1Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationMiguel BorgesPetrobras/Cenpes
2Petrobras ROM Media Day© 1994 – 2013 Fieldbus Foundation• The adopted Premises• The Scope of the Tests• Local Test – ROM ...
3Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationThe Adopted Premises• The normal operation of the plant could not...
4Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationThe scope of the testsFor Petrobras, the primary objective of thi...
5Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationLocal test – ROM Architecture• On local test, thefollowing functi...
6Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Test – ROM Architecture• For test purposes, the PC3 unit i...
7Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationLive Demonstration of ROM Technology• The live demonstration will...
8Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Operation of the Plant[DEMO] Remote access to the local op...
9Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Operation of the Plant• [DEMO] Access to all the block par...
10Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Operation of the Plant• [DEMO] Remote operation of field ...
11Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationAsset Management[DEMO] Removal of the MDI module of Stahl ROM de...
12Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationAsset Management[DEMO] Simulation of failure of one temperature ...
13Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationConclusions• With ROM technology these tests showed no restricti...
14Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationThanking you!
Upcoming SlideShare
Loading in …5
×

Petrobras rom demonstration miguel borges - petrobras

520 views
466 views

Published on

Presentation from Miguel Borges of Petrobras at the FOUNDATION for ROM media day

Published in: Technology, Business
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total views
520
On SlideShare
0
From Embeds
0
Number of Embeds
9
Actions
Shares
0
Downloads
8
Comments
0
Likes
0
Embeds 0
No embeds

No notes for slide

Petrobras rom demonstration miguel borges - petrobras

  1. 1. 1Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationMiguel BorgesPetrobras/Cenpes
  2. 2. 2Petrobras ROM Media Day© 1994 – 2013 Fieldbus Foundation• The adopted Premises• The Scope of the Tests• Local Test – ROM Architecture• Remote Test – ROM Architecture• Live Demonstration of ROM Technology• Remote Operation of the Plant• Asset Management• ConclusionsOutline
  3. 3. 3Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationThe Adopted Premises• The normal operation of the plant could not be affected• All ROM field devices will be installed in parallel to existingplant instruments, sharing the same primary element(sensor)• The existing DCS configuration will not be changed aswell as the supervisory operation screens• A new screen should be configured to the FieldbusFOUNDATION™ for ROM live demo• The radio backhaul path should provide cyber security• All the necessary technical support for the installation,configuration and start-up for all the ROM equipmentshould be guaranteed by the respective manufacturers
  4. 4. 4Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationThe scope of the testsFor Petrobras, the primary objective of this livedemonstration at the pilot plant PC3 was to verifythat we could access and use remotely, with ROM, allthe operational functionalities available locallyAnother objective was to check the interoperabilityof ROM devices of different manufactures over thebackhaul
  5. 5. 5Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationLocal test – ROM Architecture• On local test, thefollowing functionalitieswere tested:• Configuration of ROM andfield devices• Commissioning of the fielddevices• Operation of the plant• Asset management
  6. 6. 6Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Test – ROM Architecture• For test purposes, the PC3 unit is the REMOTE SITE• And this visualization room is the REMOTE CONTROLROOM
  7. 7. 7Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationLive Demonstration of ROM Technology• The live demonstration will focus on:• Remote operation of the plant• Remote asset management of the plant and ROMdevices• [REMOTE CONTROL ROOM] Visualization of thearchitecture screens
  8. 8. 8Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Operation of the Plant[DEMO] Remote access to the local operation data. No information is lost!The remote screen shows the same information seen at the original localoperation screen and information from the new ROM devices (ROMdevices plus field devices connected to them).• [CAMERA] Original PC3 screen. Video received via backhaul.• [REMOTE CONTROL ROOM] Main DCS operation screen(overview).• OPC Data from original PC3 being received via backhaul.• HSE ROM device information being received via backhaul.Visualization of the “FF ROM Tags” screen
  9. 9. 9Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Operation of the Plant• [DEMO] Access to all the block parameters andparametrization• [REMOTE CONTROL ROOM] Changing of a blockparameter
  10. 10. 10Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationRemote Operation of the Plant• [DEMO] Remote operation of field device connected to theROM via HSE• [REMOTE CONTROL ROOM] Actuation of an on-off valvewith position indication• [CAMERA] Visualization of valve position change
  11. 11. 11Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationAsset Management[DEMO] Removal of the MDI module of Stahl ROM deviceresulting in a mismatch indication• [REMOTE CONTROL ROOM] Visualization of theconfiguration of the ROM device• [CAMERA] Visualization of the ROM cabinet
  12. 12. 12Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationAsset Management[DEMO] Simulation of failure of one temperature sensor(thermocouple) resulting in a sensor failure indication• [REMOTE CONTROL ROOM] Visualization of the plantoverview screen warning the failure
  13. 13. 13Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationConclusions• With ROM technology these tests showed no restrictionsand no differences to:• Operation of the plant• Asset Management• Configuration of blocks• Commissioning• Very easy and quick integration, transparent to the user• Verification of the interoperability of ROM devices fromdifferent manufacturers
  14. 14. 14Petrobras ROM Media Day© 1994 – 2013 Fieldbus FoundationThanking you!

×