Your SlideShare is downloading. ×
Fassade 19
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×

Introducing the official SlideShare app

Stunning, full-screen experience for iPhone and Android

Text the download link to your phone

Standard text messaging rates apply

Fassade 19

653
views

Published on


0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
653
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
3
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Schüco E2 FassadeSchüco E2 FaçadeEnergie sparen und Energie gewinnenSaving Energy and Generating Energy
  • 2. 2 Schüco Seitentitel deutsch Seitentitel englisch
  • 3. Inhalt Schüco 3 Schüco 3 Contents Inhalt ContentsNachhaltiger Klimaschutz 4 Kostenoptimierter Lebenszykluskombiniert mit höchster der ImmobilieRentabilität, Komfort und Design Cost-effectiveMit der Schüco E2 Fassade bietet property life cycleSchüco schon heute eine konkreteAntwort auf die aktuellen 5 Funktionsmodule derHerausforderungen des Klima- Schüco E2 Fassadewandels. Sie ermöglicht zukunfts- Function modules in theorientierte Lösungen für innova- Schüco E2 façadetive Gebäudekonzepte, die gleich-zeitig Energie sparen und Energie 6 Öffnungselemente:gewinnen – und damit einen flächenbündig integriertnachhaltigen Beitrag zur Reduk- Opening units:tion der CO2-Emissionen leisten. Flush-fittedHöchste Effizienz garantiert die 8 Sonnenschutz:Schüco E2 Fassade auch in transparent und hochbelastbarpuncto Rentabilität: Sie bietet Solar shading: Transparentdeutliche Vorteile bei den Investi- and highly resilienttionskosten und überzeugt durcheine rentable Bewirtschaftung der 10 Dezentrale Lüftung:Immobilie bei gleichzeitig höchs- für optimalestem Nutzerkomfort – und das Raumklimaüber den gesamten Lebenszyklus Decentralised ventilation:des Gebäudes. for optimum internal climateSustainable climate protectioncombined with maximum 14 Solarmodule:profitability, comfort and design fassadenintegrierteWith the Schüco E2 façade, PhotovoltaikSchüco already has a concrete Solar modules: Façade-answer to the current challenges integrated photovoltaicspresented by climate change. Itallows pioneering solutions for 16 Fassadenautomation:innovative building concepts, Energieeffizienz und Komfortwhich save energy and generate Façade automation: Energyenergy, thereby making a lasting efficiency and conveniencecontribution to reducing CO2emissions. 18 Komplett geprüftes System Fully tested systemThe Schüco E2 façade ensuresmaximum efficiency and 19 Schüco E2 Fassade –maximum profitability. It offers die neue Dimension des Bauensclear investment benefits Schüco E2 façade –and guarantees profitable the new dimension ofmanagement of real estate constructionwith maximum user comfort.All that over the entire life cycleof the building.
  • 4. 4 Schüco Schüco E2 Fassade Schüco E2 Façade Kostenoptimierter Lebenszyklus der Immobilie Cost-effective property life cycle Die Schüco E2 Fassade ist ein The Schüco E2 façade is an system solutions, which can be energieeffizientes Gesamtsystem energy-efficient, complete adapted to the most diverse mit einer völlig neuartigen system with a revolutionary building types and climate zones. Verbindung von Fassaden- und combination of façade and This guarantees increased Anlagentechnik, die zugleich system technology, which both flexibility in use, an improved Energie einspart und Energie saves and generates energy. working environment and greater gewinnt. Bereits in der Planungs- Investment costs can be reduced user satisfaction, and therefore phase lassen sich damit die as early as the planning stage also a significant improvement in Investitionskosten senken und and the operating costs can be the long-term marketability of die Betriebskosten über den actively managed and optimised the property. gesamten Lebenszyklus eines over the entire life cycle of a Gebäudes aktiv steuern und building. The result is maximum All of the modules in the Schüco optimieren. Das Ergebnis: economic success of the E2 façade system are tested for maximaler wirtschaftlicher Erfolg property with the highest their functional and energy der Immobilie bei bestmöglicher possible energy efficiency, properties, both as individual Energieeffizienz, Ressourcen- conservation of resources and components and in their und Umweltschonung. environmental protection. interaction with one another, using optimised interfaces, for all Die nachhaltige Senkung der The sustained reduction in trades. This ensures maximum Investitions- und Betriebskosten investment and operating costs reliability in planning and design. wird durch die vier Funktions- is achieved by means of the four module der Schüco E2 Fassade function modules in the Schüco erzielt: Öffnungselemente, E2 façade: opening units, solar Sonnenschutz, dezentrale shading, decentralised ventilati- Lüftung und Solarmodule. on and solar modules. Innovative Innovative Technologien ermög- technology permits flexible lichen flexible Systemlösungen, die an unterschiedlichste Gebäudearten und Klimazonen angepasst werden können. Das garantiert eine höhere Nutzungs- Gesamtbaukosten im Vergleich flexibilität, Arbeitsplatzqualität Comparison of total building costs und Nutzerzufriedenheit – und damit auch eine deutliche Verbesserung der langfristigen  Marktfähigkeit der Immobilie.   Alle Module des Systembaukas-  ?DEE@?D<@DE? tens der Schüco E2 Fassade sind ?DE>?E:@DED  bezüglich ihrer funktionalen und  energetischen Eigenschaften sowohl als Einzelkomponenten  als auch in ihrem Zusammen-  spiel geprüft – mit optimierten  Schnittstellen für alle Gewerke.  Das gewährleistet höchste  Sicherheit bei der Planung und /C?9;>E?EC8=C 9;>E;?EC8=C)]E? )]E?D8?=8 %=;?E;:?EC8=D;?E=8E@? Ausführung. /C?:9=;?E:?EC8= ?E=8E@?DDE> /)1$?=8 08?EC=<EC<C;C8?=8? $C:@?;E@??DDE> 08?E8E@?=:EC:D=ED ?D8?=8 /@98<@DE? 8E?DDE> %=;?D==:@DED
  • 5. Schüco E2 Fassade Schüco 5 2 Schüco E FaçadeFunktionsmodule der Schüco E2 FassadeFunction modules in the Schüco E2 façadeMit den vier Funktionsmodulen The Schüco E2 façade is basedlassen sich individuelle on four function modules thatLösungspakete realisieren: permit individual solutions.umsetzbar als Gesamtsystem It can be used as a completeoder in flexibel konfigurierbaren system or in flexible modularModulkombinationen. combinations.Öffnungselemente Opening unitsDie nicht sichtbare flächenbün- The concealed, flush-fitteddige Integration aller Öffnungs- integration of all opening units,elemente inklusive ihrer including their system drives,Systemantriebe sorgt für ensures maximum creative Flächenbündige Öffnungselementemaximale Gestaltungsfreiheit freedom when designing Flush-fitted opening unitsbeim Fassadendesign und façades and perfect integrationperfekte Anbindung an die with the building managementGebäudeleittechnik. system.Sonnenschutz Solar shadingDer außen liegende Sonnen- With its slimline micro louvreschutz mit seinen filigranen blades, the external solarMikro-Lamellen sorgt für eine shading ensures both efficienteffiziente Abschattung bei shading and maximumgleichzeitig größtmöglicher transparency when looking toTransparenz bei der Sicht nach the outside.außen. Decentralised ventilation Hochbelastbarer SonnenschutzDezentrale Lüftung The compact and concealed Highly resilient solar shadingDie kompakt und nicht sichtbar decentralised ventilationvor den Geschosstrenndecken technology positioned in frontim Fassadenelement positio- of the intermediate floors innierte dezentrale Lüftungs- the façade unit opens up newtechnik eröffnet neue architek- architectural design possibilities.tonische Spielräume: For example, the absence ofz. B. durch den Wegfall von shaft and service areas and theSchacht- und Technikflächen reduced storey heights thatsowie die dadurch reduzierten result.Geschosshöhen. Solar modulesSolarmodule The photovoltaic modules,Die variabel als Teilflächen oder which can be used either as Fassadenintegrierte dezentrale Lüftunggeschosshoch einsetzbaren, in partial areas or inserted at full Façade-integrated decentralised ventilationForm, Farbe und Struktur flexibel storey height and which cangestaltbaren Photovoltaikmodule be designed individually in termsmachen die Gebäudehülle zu of shape, colour and structure,einem Energieproduzenten und make the building envelopeübernehmen dabei sämtliche into an energy producer. Theyfunktionalen Eigenschaften einer therefore have all the propertieskonventionellen Verglasung. of conventional glazing. Objektspezifische Solarmodule Project-specific solar modules
  • 6. 6 Schüco Öffnungselemente Seitentitel deutsch Seitentitel englisch Opening units Öffnungselemente: flächenbündig integriert Opening units: Flush-fitted Größtmögliche Gestaltungsfrei- technik einbinden. Damit kön- appearance – for almost all heit bietet die Schüco E2 nen sie zentral für eine intelli- modular, storey-height glazing. Fassade durch die identischen gente automatische Lüftung This allows a new level of Ansichten von Festfeldern und angesteuert werden, z. B. für die quality in façade design. Öffnungselementen. Durch die Nachtauskühlung. Die konse- verdeckte Lage der Flügel- quente Automation aller The opening units are equipped rahmen hinter den Pfosten- Öffnungselemente sorgt für with large ventilation cross und Riegelprofilen sind alle höchsten Nutzerkomfort und ist sections and can be integrated begrenzenden Flächen bündig gleichzeitig ein weiterer Baustein in the building management und homogen in der Gesamt- für die optimierte Energiebilanz system by means of concealed ansicht – bis hin zu annähernd des Gebäudes. system drives. This allows the beliebig gerasterten, geschoss- units to be controlled centrally hohen Verglasungen. Das The identical appearance of for intelligent, automatic ermöglicht eine neue Qualität in fixed lights and opening units ventilation, e.g. night-time der Fassadenästhetik. means that the Schüco E2 cooling. The uniform automation façade offers maximum design of all the opening units provides Die mit großen Lüftungsquer- freedom. Due to the concealed maximum convenience for the schnitten ausgestatteten position of the vent frames user and at the same time, is Öffnungselemente lassen sich behind the mullion and transom another factor in the optimum per verdeckt liegenden System- profiles, all adjacent surfaces are energy balance of the building. antrieben in die Gebäudeleit- flush and uniform in the overall Geschosshohe Öffnungselemente Storey-height opening units
  • 7. Öffnungselemente Schüco 7 Opening unitsDank der exzellenten statischen Thanks to the excellentEigenschaften der Aluminium- structural properties ofKonstruktionen sowie innovati- aluminium constructions andver Beschlagstechnologie sind innovative fittings technology,auch großdimensionierte generously sized opening unitsÖffnungselemente mit hohen with large vent weights are alsoFlügelgewichten realisierbar. possible. They are impressive asAls Senkklapp- oder Parallel- projected top-hung windows orAusstell-Fenster überzeugen parallel-opening windows withsie mit optisch durchgängigen, slender face widths throughoutfiligranen Ansichtsbreiten von of only 85 mm.nur 85 mm. Key benefitsDie Vorteile auf einen Blick • Attractive façade design with• Ästhetisches Fassadendesign flush-fitted integration of the durch flächenbündige Profil- profile in the mullion/transom integration in das Pfosten- load-bearing structure and Riegel-Tragwerk und komplett fully concealed system drives verdeckt liegende System- • Intelligent control is possible Schüco SFC 85 mit Parallel-Ausstell-Fenster antriebe using building management Schüco SFC 85 with parallel-opening window• Intelligente Ansteuerung über technology: energy saving in Gebäudeleittechnik möglich: combination with night-time Energieeinsparung in Kombi- cooling nation mit Nachtauskühlung • Maximum comfort due to• Maximaler Komfort durch individual, natural ventilation individuelle natürliche Lüftung • Large window constructions• Großdimensionierte Fenster- with vent weights up to konstruktionen mit Flügel- 250 kg are possible gewichten bis max. 250 kg • Projected top-hung window:• Senkklapp-Fenster: Rastdreh- ratchet stay holds the window begrenzer hält im manuellen in the desired opening Betrieb bei Winddruck und position when subject to Windsog das Fenster in positive or negative window der gewünschten Öffnungs- loads during manual operation position fest Schüco SFC 85 mit Senkklapp-Fenster Schüco SFC 85 with projected top-hung window
  • 8. 8 Schüco Sonnenschutz Solar shading Sonnenschutz: transparent und hochbelastbar Solar shading: Transparent and highly resilient Der außen liegende Schüco Sonnenschutz CTB (Concealed Toughened Blind) kann dank einer hohen Lamellen- stabilität auch bei hohen Wind- geschwindigkeiten bis 30 m/s ausgefahren werden. Der transparente Behang aus Mikro-Lamellen sorgt für einen optimalen Sonnenschutz mit einer kompletten Abschattung schon ab einer Sonnenhöhe von 20°. Für die Nutzer der Räume wird so eine maximale visuelle Behaglichkeit inklusive Sicht nach außen erreicht. Witterungsbeständige Mikro-Lamellen aus Aluminium Weather-resistant, aluminium micro louvre blades Während der wärmeren Jahres- zeiten lässt sich durch das außen liegende System eine Reduzierung der Kühllast für das Gebäude um rund 50 % errei- chen. Damit leistet das Funktionsmodul Sonnenschutz einen beachtlichen Beitrag zur Senkung der Betriebskosten. 20° The external Schüco CTB (Concealed Toughened Blind) solar shading can even be lowered in high wind speeds of up to 30 m/s thanks to the high stability of the blades. The transparent blind consists of Abschattung ab 20° Sonnenhöhe micro louvre blades that ensure Shading from when the sun is at an angle of 20° solar shading and anti-glare protection with complete shading from when the sun is at an angle of 20°. This guarantees maximum visual comfort, including visibility to 50° the outside. 20° During the warmer months, it is possible to reduce the cooling load for the building by approximately 50% thanks to the external system. The solar shading function module thereby makes a considerable contribution to reducing the operating costs. Hohe Transparenz von innen High level of transparency from the inside
  • 9. Sonnenschutz Schüco 9 Solar shadingFlächenbündige Fassadenoptik Flush façade appearanceIn eingefahrenem Zustand liegt When the blind is retracted, theder Sonnenschutz nicht sichtbar solar shading is not visible as itfassadenintegriert im opaken is integrated in the façade inBereich vor der Geschosstrenn- the opaque area in front of thedecke und sorgt für eine flächen- intermediate floor. This ensuresbündige Optik der Fassade. Der that the façade has a flushbei konventionellen Sonnen- appearance. A fascia boxschutzanlagen vor die Fassade mounted on the front ofmontierte Blendenkasten entfällt the façade, as found withsomit komplett. conventional solar shading systems, is therefore no longerExterne Systemprüfung necessary.Der Schüco Sonnenschutz CTBbietet höchste Planungssicher- External system testingheit durch unabhängige externe Schüco CTB solar shading offersPrüfungen, z. B. bezüglich maximum planning reliabilityWindgeschwindigkeiten und courtesy of independent externalGesamtenergiedurchlassgrad. tests, for example, with regard to wind speeds and total solar Fassadenelemente mit energy transmittance. Schüco Sonnenschutz CTB Façade units with Schüco CTB solar shading
  • 10. 10 Schüco Dezentrale Lüftung Decentralised ventilation Dezentrale Lüftung: für optimales Raumklima Decentralised ventilation: for optimum internal climate Schon heute wird die Planung von Büroflächen maßgeblich durch folgende Punkte bestimmt: die immer anspruchs- vollere Gesetzes-, Verordnungs- und Normenlage sowie die Erkenntnisse der Arbeitsplatz- forschung. Diese hat einen ein- deutigen Zusammenhang zwi- schen einem thermisch-klima- tisch behaglichen Raumklima und der steigenden Leistungs- fähigkeit sowie der Gesundheit der Raumnutzer nachgewiesen. Die Zufuhr von „richtiger“ Frischluft durch eine optimale Be- und Entlüftung, am besten raumweise an die individuellen Bedürfnisse angepasst, ist dabei ein zentraler Faktor. Die positiven ökonomischen Effekte durch die gesteigerte Leistungsfähigkeit der Büro- Dezentrale Lüftungstechnik: Lüftung, Heizung, Kühlung nutzer erstrecken sich über Decentralised ventilation technology: ventilation, heating and cooling die gesamte Nutzungszeit der Immobilie und bieten gewerb- lichen Nutzern einen erheblichen Increasingly complex laws, room climate and the increased Mehrwert. regulations and standards, productivity and health of a coupled with the findings from room’s occupants. A central workplace studies, have already factor here is the supply of real had a significant impact on the fresh air by means of optimum planning of office space today. ventilation, which is best tailored The findings have revealed a to the individual requirements clear link between a comfortable for each room. The positive economic effects Abhängigkeit geistige Leistungsfähigkeit zur Raumtemperatur resulting from the increased Effect of room temperature on concentration level productivity of the office users cover the entire period that the property is in use and therefore offer commercial users 100 % significant added value. 95 % Geistige Leistungsfähigkeit [%] 90 % Concentration level [%] 85 % 80 % 75 % 70 % 65 % Raumtemperatur [°C] / Room temperature [°C] Quelle / Source: D. Wyon
  • 11. Dezentrale Lüftung Schüco 11 Decentralised ventilationVorteile für die ImmobilienvermarktungBenefits for the property marketOptimierung der Baukosten Gebäudehöhe und Geschosszahl bei zentraler undBei Gebäuden mit einem dezen- dezentraler Lüftungtralen Lüftungskonzept von Building height and number of floors forSchüco lässt sich durch die centralised and decentralised ventilationsystembedingte Reduzierung vonZwischendecken die Geschoss-höhe verringern. Diesenentscheidenden Vorteil fürInvestoren veranschaulicht die Building height in m Gebäudehöhe in mnebenstehende Grafik:Entweder reduziert sich beigleicher Etagenzahl die Gesamt-bauhöhe. Das Ergebnis: eineerhebliche Senkung der Rohbau-kosten. Oder es erhöht sich beigleicher Bauhöhe die Anzahl derGeschosse. Das bedeutet eine Zentrale Lüftung für Dezentrale Lüftung für Dezentrale Lüftung für 30 Geschosse 30 Geschosse 33 Geschossedeutliche Steigerung der Gesamt- Centralised ventilation Decentralised ventilation Decentralised ventilationmietfläche und damit der for 30 floors for 30 floors for 33 floorsVermarktungserlöse.Reduzierung der Betriebskosten Optimising construction costs costs of the building shell,Durch die dezentrale, individuelle In buildings with a decentralised or the number of floors will beRegelung in kleinen Nutzungs- ventilation concept from Schüco, increased for the sameeinheiten, z. B. raumweise unter the storey height can be reduced construction height, whichBerücksichtigung wechselnder as the system requires less means a significant increaseNutzungszeiten und -kapazitäten, space between floors. The graph in the total rental area andwird der Energieverbrauch auf above illustrates the decisive therefore in potential revenues.den notwendigen Bedarf redu- advantage for investors. Eitherziert. Mit der Senkung der the total construction height will Reduction in operating costsBetriebskosten ergibt sich ein be reduced for the same number Energy consumption is reducedweiterer wichtiger Vorteil für die of floors, which results in a to the required amount as aVermarktung der Immobilie. considerable reduction in the result of decentralised, individual regulation in small operational units, e.g. room by room, taking into account changing usage periods and capacities.Vergleich dezentrale / zentrale Lüftung This significantly reduces theComparison of decentralised / centralised ventilation operating costs of the property and is therefore an additional Dezentrale Lüftung Zentrale Lüftung benefit. • Autarkes Lüftungsgerät in Fassadennähe • Lüftungszentrale im Keller, Dach- oder Technikgeschoss • Luft wird über Fassadenöffnungen angesaugt • Luftverteilung über Lüftungsrohre bzw. ausgeblasen • Individuelle raumweise Regelung • Nur bedingt individuell raumweise regelbar • Hohe Flexibilität bei Nutzungsänderung • Geringe Flexibilität bei Nutzungsänderung innerhalb des Gebäudes Decentralised ventilation Centralised ventilation • Stand-alone ventilation device • Ventilation control unit in the basement, attic or next to the façade on the service floor • Air is drawn in or blown out through openings • Air distributed via ventilation pipes in the façade • Individual room-by-room regulation • Can only be regulated on an individual room-by-room basis to a limited extent • High degree of flexibility in the event of a • Minimal flexibility in the event of a change in change in use use within the building
  • 12. 12 Schüco Dezentrale Lüftung Decentralised ventilation Dezentrale Lüftung – designorientiert und effizient Decentralised ventilation – stylish and efficient Bei der Schüco E2 Fassade sind die Komponenten für die dezen- trale Lüftung mit den Funktionen Heizung und Kühlung der Zuluft kompakt und unsichtbar in das vor der Geschosstrenndecke liegende Technikmodul inte- griert, welches auch den außen liegenden Sonnenschutz aufneh- men kann. Das ermöglicht die Umsetzung selbst geschosshoher Verglasungen und dadurch auch eine flächige Fassadenoptik. Zusätzliche Designoptionen Der Wegfall von Technikflächen inklusive der zentralen Luftvertei- lung sowie die Verlagerung der Anlagentechnik in den opaken Bereich der Geschossübergänge eröffnet dem Architekten zusätz- liche Optionen: die Planung homogener, hochtransparenter und designorientierter Fassaden ohne Einschränkung der gewünschten Fassadenansicht. Maximale architektonische Freiräume Die flexiblen Einbaumöglich- Fassadenintegrierte dezentrale Lüftung keiten (Deckeneinbau, Boden- Façade-integrated decentralised ventilation einbau, Decken- und Bodenein- bau) der Lüftungstechnik sowie die Anpassung an unterschied- In the Schüco E2 façade, the floor areas presents the architect lichste Deckenaufbauten ermög- components for decentralised with additional options – lichen die Integration in nahezu ventilation are integrated with no restrictions on the façade jeden Gebäudetyp. the functions of heating and appearance when planning cooling incoming air in a homogeneous, highly compact and concealed fashion transparent and stylish façades. in the service module, which is located in front of the Maximum architectural intermediate floor and which freedom can also hold the external solar The flexible installation options shading. This even permits floor- (ceiling installation, floor to-ceiling glazing to be used, installation, ceiling and floor which gives the façade a sleek installation) for ventilation appearance. technology and adaptation to the widest range of floor / ceiling Additional design options constructions allows for The absence of service areas, integration in almost all types including decentralised air of building. distribution and the relocation of the systems technology to the opaque area in the intermediate
  • 13. Dezentrale Lüftung Schüco 13 Decentralised ventilationModulare Lüftungskonzepte für jede AnforderungModular ventilation concepts for every requirementFür die Schüco E2 Fassadestehen fünf unterschiedliche,modular aufgebaute dezentraleLüftungskonzepte mit und ohneWärmerückgewinnung zurVerfügung. Die Wärmerückge-winnung sorgt sehr effizient fürzusätzliche Einsparpotenzialebei der Heizenergie. Mit diesenLüftungskonzepten ist eine An-passung an die Anforderungenunterschiedlichster Gebäude-arten und Nutzungsbedingungenmöglich. Sie sind sowohl für denNeubau als auch in der Sanie-rung einsetzbar.Die Nutzer können das Raum- Beispiel: dezentrales Lüftungskonzept 1klima ganz individuell raumweise Quellluftartige Einbringung der erwärmten oder gekühlten Zuluft. Die Abluft wird über ein Deckengerätan ihr persönliches Behaglich- abtransportiert. Es erfolgt keine Wärmerückgewinnung. Example: Decentralised ventilation concept 1keitsempfinden anpassen, z. B. Heated or cooled incoming air is drawn into the room by displacement ventilation.durch das Anwärmen oder The outgoing air is extracted via a ceiling device. There is no heat recovery.das Kühlen der Zuluft sowiedie stufenweise Einstellung desLuftvolumenstroms.The Schüco E2 façade has fivedifferent, modular conceptsavailable for decentralisedventilation, with and withoutheat recovery. Heat recovery isvery efficient in increasing thepotential for saving heatingenergy. These ventilationconcepts make it possible toadapt to the requirements ofthe most diverse building typesand conditions of use. They canbe used for both new builds andin renovation projects.The users can adjust the indoor Beispiel: dezentrales Lüftungskonzept 4climate to their personal comfort Einbringung der erwärmten bzw. gekühlten Zuluft an der Decke. Die Abluft wird ebenfalls über das Deckengerät abgeführt, sodass eine Wärmerückgewinnung erfolgt.level on an individual, room-by- Example: Decentralised ventilation concept 4room basis, for example, by Heated or cooled incoming air is drawn into the room via the ceiling.warming or cooling the incoming The outgoing air is also released via the ceiling device for heat recovery.air and by adjusting the airvolume flow incrementally.
  • 14. 14 Schüco Solarmodule Solar modules Solarmodule: fassadenintegrierte Photovoltaik Solar modules: Façade-integrated photovoltaics Angesichts stetig steigender In view of constantly rising Energiepreise durch immer knap- energy prices caused by per werdende fossile Brennstoffe dwindling reserves of fossil fuels, gehört der Solartechnik mit der the future already lies with solar Sonne als kostenloser, uner- technology, which uses the sun schöpflicher Energiequelle schon as a free and inexhaustible source heute die Zukunft. Dazu bietet of energy. Solar technology also die Solartechnologie eine offers “clean” energy generation „saubere“ Energiegewinnung without CO2 emissions, thereby ohne CO2-Emissionen und liefert making a significant contribution damit auch einen wichtigen Bei- to climate protection. trag zum Klimaschutz. With Schüco façade-integrated Mit den fassadenintegrierten photovoltaic modules, the Photovoltaikmodulen von Schüco E2 façade features a Schüco verfügt die Schüco highly efficient component for E2 Fassade über einen hoch- solar energy generation. The effizienten Baustein zur solaren solar modules meet all the Transluzente Photovoltaikintegration Stromgewinnung. Dabei erfüllen requirements of a conventional Translucent photovoltaic integration die Solarmodule alle Anforde- infill unit in terms of thermal rungen eines herkömmlichen insulation, weather resistance Füllungselements bezüglich and sound reduction. Wärmedämmung sowie Witte- rungs- und Schallschutz. Schüco SFC 85 mit transparenten Photo- voltaikmodulen Schüco SFC 85 with transparent photovoltaic modules
  • 15. Solarmodule Schüco 15 Solar modulesGestaltungsoptionen für PhotovoltaikmoduleDesign options for photovoltaic modulesEbenso wie die Öffnungselemente Integration der Photovoltaik- defined using transparentwerden die Photovoltaikmodule module. Solarzellen und Gläser modules, which feature uniformflächenbündig in das Tragwerk bieten in puncto Größe, Format, modules that can vary in design.der Schüco E2 Fassade inte- Farbe, Struktur und Funktion The views to the outside createdgriert – je nach Anforderung eine breite Gestaltungs- und and the use of light from thetransluzent oder transparent. Ausführungspalette für eine indi- entire height of the unit allows viduelle, objektspezifische for storey-height integration ofTransluzente Module bieten per- Fassadengestaltung. photovoltaic modules. Solar cellsfekte Lösungen für alle blick- and glazing provide a wide rangedichten Fassadenbereiche wie As with the opening units, the of design options in terms ofz. B. Brüstungen. Mit transparen- photovoltaic modules are size, shape, colour, structure andten Modulen, die sich durch ein flush-fitted in the load-bearing function for an individual,variabel gestaltbares, homoge- structure of the Schüco E2 project-specific façade design.nes Raster auszeichnen, lässt façade – translucent orsich der Durchblick nach drau- transparent as required.ßen bestimmen. Der damiterreichte Außenbezug ermög- Translucent modules providelicht zusammen mit der Lichtauf- perfect solutions for all opaquenahme über die gesamte façade areas, e.g. spandrels.Elementhöhe die geschosshohe The view to the outside can beStruktur: Polykristalline oder monokristalline Zellen Farbe: breite Palette an Zellfarben für die varian- Größe / Format: Verschiedene Größen in densetzen unterschiedliche ästhetische Akzente. tenreiche Gestaltung mit kristallinen Photovoltaik- Formaten rechteckig, quadratisch und pseudo-Structure: polycrystalline or monocrystalline cells modulen. quadratisch mit abgeschrägten Ecken stehen beicreate different design accents Colour: a wide range of cell colours for variety in kristallinen Photovoltaikzellen zur Auswahl. design using crystalline photovoltaic modules Size / shape: different sizes available in the following shapes when using crystalline photovoltaic cells – rectangular, square and square with bevelled cornersInnovation: BSC-Zelle (back-side-contact) mit Amorphe Dünnschichtzellen: Durch individuelle CIS-Dünnschichtzellen: Weisen eine besondersaußerordentlich hohem Wirkungsgrad und Laserung der Submodule kann bei transparenter homogene Oberfläche auf. Sie sind unempfindlichklarer Optik durch fehlendes Kontaktgitter auf Struktur das Lichtverhalten im Innenraum filigran gegen hohe Temperaturen, Teilverschattung undder Vorderseite. beeinflusst werden, ohne auf die konventionellen ungünstige Einstrahlwinkel. Somit sind sie beson-Innovation: BSC cell (back / side contact) with Eigenschaften eines Füllungselementes zu verzichten. ders gut für den Einsatz in der Fassade geeignet.outstanding efficiency levels and a streamlined Amorphous thin-film cells: for transparent CIS thin-film cells: for a particularlyappearance due to the contact grid missing from structures, individual laser cutting sub-modules homogeneous surface finish. They are resistant tothe front side can affect the light inside without foregoing the high temperatures, partial shading and unfavourable conventional features of an infill unit angles of incidence. They are therefore particularly well suited for use on the façade
  • 16. 16 Schüco Fassadenautomation Façade automation Fassadenautomation: Energieeffizienz und Komfort Façade automation: Energy efficiency and convenience Höchste Energieeffizienz bei Fassadenmodule, z. B. bei auto- management system and they bestmöglichem Komfort: Die matischer Nachtauskühlung therefore permit intelligent konsequente Automatisierung sowie individueller centralised or decentralised von Öffnungselementen, Fensteröffnung. control of the façade modules, Sonnenschutz und dezentraler for example, for automatic Lüftungstechnik sorgt dafür, Maximum energy efficiency night-time cooling and opening dass die Schüco E2 Fassade bei with the utmost convenience. individual windows. geringstem Bedienaufwand Uniform automation of situations- und nutzergerecht opening units, solar shading arbeitet. So lässt sich z. B. der and decentralised ventilation individuelle Wunsch des Nutzers ensures that the Schüco E2 nach einem für ihn behaglichen façade functions in accordance Raumklima ohne Beeinträchti- with the requirements of the gung der optimierten, ressour- situation and user with minimal censchonenden Energiebilanz effort. Individual user preferences realisieren. for a comfortable room climate can therefore be accommodated Alle Systemantriebe können in without restricting the optimised, eine Gebäudeleittechnik einge- eco-friendly energy balance. bunden werden und ermöglichen so eine intelligente zentrale oder All system drives can be Voll automatisierte Fassade dezentrale Ansteuerung der incorporated into a building Fully-automated façade
  • 17. Fassadenautomation Schüco 17 Façade automationAttraktive Energiespar-potenzialeEnergiesparen mit Fassadenauto-mation beginnt immer im Einzel-raum, also am Ort der Energie-übergabe. Die dabei zu erreichen-den Energieeinsparpotenzialesind für Investor, Betreiber undMieter der Immobilie gleicher-maßen interessant.Wärme- und KühlenergieSo lassen sich beispielsweise25 % der Wärmeenergie und45 % der Kühlenergie einsparendurch eine• zeit- und präsenzabhängige Anpassung der Regelsollwerte• Abschaltung der Energie- zufuhr beim Öffnen der Fenster• Unterstützung des Heiz- oder Kühlvorgangs durch den Sonnenschutz in unbelegten Räumen Integrierter Schüco Sonnenschutz CTB• Nachtauskühlung per zentraler Integrated Schüco CTB solar shading Ansteuerung der Öffnungs- elementeBeleuchtungsenergie Attractive energy-saving Lighting energyDie hohe Transparenz des potential The high degree of transparencySchüco Sonnenschutz CTB und Saving energy with façade of Schüco CTB solar shadingder daraus resultierende über- automation always begins at and the resultant, above-averagedurchschnittlich gute Trans- room level, where energy transmission level saves amissionsgrad sparen, z. B. mit transfer takes place. The energy significant amount of lightingeiner Konstantlichtregulierung saving potential is of equal energy, for example, due tound einer Präsenzerfassung mit interest to investors, operators constant light regulation andautomatischer Abschaltung der and lessees. movement detection, whichBeleuchtung, einen nennens- automatically switches off thewerten Teil der Beleuchtungs- Heating and cooling energy lighting.energie ein. For example, 25 % of heating energy and 45 % of cooling The automation of the SchücoSomit ist die Automatisierung energy can be saved by: E2 façade is therefore a keyder Schüco E2 Fassade ein • Adjusting control target component for the optimisedwesentlicher Baustein für die values according to time energy balance of a building.optimierte Energiebilanz der and occupancy Moreover, the functional façadeImmobilie – und das ohne • Switching off the energy units do not restrict theEinschränkung der architekto- supply when windows are architectural design.nischen Gestaltung durch die openfunktionalen Fassadenelemente. • Supporting the heating or cooling process in unoccupied rooms by means of solar shading • Night-time cooling via centralised control of opening units
  • 18. 18 Schüco Planungs- und Ausführungssicherheit Planning and design reliability Komplett geprüftes System Fully tested system Die Schüco E2 Fassade bietet The Schüco E2 façade offers Architekten, Investoren, Verarbei- architects, investors, fabricators tern und Betreibern ein Optimum and operators maximum an Planungs-, Ausführungs- und planning, design and operational Betriebssicherheit. Sie ist sowohl reliability. Both its individual als Gesamtsystem als auch in function modules and its ihren einzelnen Funktions- performance as a complete modulen durch unabhängige system have been approved Prüfinstitute geprüft, z. B. vom by independent test institutes, europaweit notifizierten und for example, by ift Rosenheim, international akkreditierten the notified European test centre ift Rosenheim. Dabei erfüllte die with international accreditation. Schüco E2 Fassade auch die The Schüco E2 façade even hohen Anforderungen der satisfied the stringent DIN EN 13830 für Vorhang- requirements of DIN EN 13830 fassaden an Luftdurchlässigkeit, for curtain walling in terms of air Schlagregendichtheit und permeability, watertightness and Sicherheit. Außerdem verfügt security. The system also has das System über perfekt aufein- perfectly tailored mechanical and ander abgestimmte mechanische electronic interfaces. und elektronische Schnittstellen. Schüco E2 Fassade Schüco E2 façade
  • 19. Systemübersicht Schüco 19 System overviewSchüco E2 Fassade – die neue Dimension des BauensSchüco E2 façade – the new dimension of constructionMit den frei kombinierbaren Flexible, energy-efficient buildingFunktionsmodulen der concepts with significantlySchüco E2 Fassade und deren reduced investment andKompatibilität mit der Schüco operating costs are possible inSystemwelt lassen sich in nahe- almost all project classes due tozu allen Objektklassen flexible, the flexible function modules ofenergieeffiziente Gebäudekon- the Schüco E2 façade and theirzepte mit deutlich reduzierten compatibility with the SchücoInvestitions- und Betriebskosten system world.realisieren.Öffnungselemente / Opening units • Flächenbündige Fassadenintegration; identische • Flush-fitted façade integration; Optik von Festfeldern und Öffnungselementen fixed lights and opening units appear identical • Verdeckt liegende Systemantriebe; optional intel- • Concealed system drives; optional intelligent ligente Ansteuerung über Gebäudeleittechnik control via building management system • Energieeinsparung in Kombination mit • Energy saving in combination with Nachtauskühlung night-time cooling • Geschosshohe Fensterlösungen möglich • Storey-height window solutions possible • Große Lüftungsquerschnitte • Large ventilation cross sectionsSonnenschutz / Solar shading • Außen liegender Sonnenschutz, flächenbündig • External solar shading, flush-fitted and verdeckte Integration in die Fassade concealed integration in the façade • Nicht sichtbar im eingefahrenen Zustand; • Not visible when retracted; kein aufgesetzter Blendenkasten no surface-mounted fascia box • Systemgeprüfte hohe Windstabilität bis 30 m/s: • System-tested high wind stability up to 30 m/s; auch bei großen Gebäudehöhen einsetzbar can even be used in high buildings • Transparenter Mikro-Lamellenbehang; komplette • Transparent blind consisting of micro louvre Abschattung schon ab 20° Sonnenhöhe blades, complete shading from when the sun is at an angle of 20°Dezentrale Lüftung / Decentralised ventilation • Autarkes, nicht sichtbares Lüftungssystem in der • Stand-alone ventilation system concealed in the Fassade; geschosshohe Verglasungen möglich façade; storey-height glazing possible • Behagliches Raumklima und individuelle raum- • Comfortable indoor climate and fresh air weise Frischluftregelung; höhere Leistungsfähigkeit regulation on an individual, room-by-room basis; • Baukostenoptimierung durch Reduzierung von increased productivity Zwischendecken und Technikflächen • Optimisation of construction costs due to less space • Hohe Flexibilität bei Nutzungsänderung between floors and reduction in service areas • Reduzierung der Betriebskosten • High degree of flexibility in the event of a change in use • Reduction in operating costsSolarmodule / Solar modules • Fassadenintegrierte transluzente oder transparente • Façade-integrated translucent or transparent Photovoltaikmodule zur Solarstromgewinnung photovoltaic modules for generating solar energy • Flexibel gestaltbar in Form, Farbe, Struktur • Flexible design in terms of shape, colour and • Bei geschosshohen Photovoltaikmodulen optional structure auch Sicht nach außen realisierbar • Visibility to the outside also possible for storey- • Erfüllen alle funktionalen Anforderungen eines height photovoltaic modules konventionellen Einsatzelements: z. B. Wärme- • Fulfilment of all the functional requirements of a dämmung, Witterungs- und Schallschutz conventional insert unit, e.g. thermal insulation, weather resistance and sound reduction
  • 20. Schüco E2 Fassade Schüco E2 façadeSchüco – die Adresse für Fenster und Solar Die innovative, energieoptimierte The innovative, energy-efficientSchüco – Your Partner for Windows and Schüco E2 Fassade bietet eine Schüco E2 façade offers theSolar Products optimale Verbindung von optimum combination of façadeAls Innovationsführer für systemgestütztes Bauen Fassaden- und Anlagentechnik and system technology andliefert Schüco Komponenten für die gesamte und eröffnet eine neue opens up a new dimension inGebäudehülle inklusive spezieller Softwarelösungen Dimension der Gebäudeästhetik. building design. Consistinghinsichtlich Planung, Konstruktion, Kalkulation und Bestehend aus vier Funktions- of four function modules –Fertigung. modulen – Öffnungselemente, opening units, solar shading,As leading innovator in system-based construction,Schüco supplies components for the whole building Sonnenschutz, dezentrale decentralised ventilation andenvelope, including specialised software solutions Lüftung und Solarmodule –, solar modules – the fully-testedfor design, construction, calculation and fabrication. lässt sich das komplett geprüfte, system with optimised interfaces schnittstellenoptimierte System can be implemented as aAluminium-Systeme Aluminium systems als Komplettlösung oder in complete or partial solution.Stahl-Systeme Steel systems Teilkombinationen realisieren.Kunststoff-Systeme PVC-U systemsSolar-Systeme Solar productsSchüco Design Schüco DesignSchüco International KGwww.schueco.com P3245/05.09/Printed in Germany