Cheyenne Landfill Lining Project is presented by presented by John B. Heap President of Colorado Lining International, Parker, CO

Cheyenne Landfill Lining Project is presented by presented by John B. Heap President of Colorado Lining International, Parker, CO

Published in: Education
0 Comments
0 Likes
Statistics
Notes
  • Be the first to comment

  • Be the first to like this

No Downloads
Views
Total Views
420
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
0
Comments
0
Likes
0
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide

Transcript

  • 1. Cheyenne Landfill Lining Project Cheyenne, Wyoming <ul><li>Presented by John B. Heap </li></ul><ul><li>President, Colorado Lining </li></ul><ul><li>International, Parker, CO </li></ul>FGI Cheyenne Case History – John B. Heap © 2002 PGI-TP, University of Illinois at Urbana-Champagn, All Rights Reserved Slide of 21
  • 2. <ul><li>The Cheyenne Landfill, Phase II - North Trench Project </li></ul><ul><li>Owner: City of Cheyenne </li></ul><ul><li>Engineer: Inberg-Miller Engineers </li></ul><ul><li>Material: 30 mil PVC </li></ul><ul><li>Quantity: 815,600 sf </li></ul>
  • 3. PANEL LAYOUT
  • 4. INSTALLATION -Panel Placement- <ul><li>Upon approval of subgrade, CLI began to deploy and weld fabricated panels of 30 Mil PVC as shown on our layout drawings. </li></ul>
  • 5. INSTALLATION -Wedge Welding- <ul><li>All field seams were completed using a single track wedge welder. </li></ul><ul><li>This method allows us to immediately check seams for strength and continuity. </li></ul>
  • 6. INSTALLATION -Destructive Testing- <ul><li>To verify field seam strengths the following tests were performed: </li></ul><ul><li>Destructive Tests- 3’ X 12” were pulled every 500 LF of field seam. Five 1 inch wide samples were pulled in sheer and peel to verify conformance with the construction specifications and PGI/1197 specifications. Samples are retained as follows: </li></ul><ul><li>1 set to owner </li></ul><ul><li>1 set to GC </li></ul><ul><li>1 set to CLI </li></ul>
  • 7. INSTALLATION -Continuity Testing- <ul><li>Continuity Testing- was performed on all field seams using ASTN D 4464 air lance method. This method involves using a stream of compressed air 55 psi along the edge of the seam. CLI quality control technician and engineer visually looked for any loose or un-bonded edges along the edge of the </li></ul><ul><li>seam. </li></ul>
  • 8. INSTALLATION -Completion- <ul><li>Upon completion and acceptance of lining placement of 18” of drainage sand begins. </li></ul>
  • 9. OVERVIEW PHOTO

×