  • 1. MODEL: Q-200BLOOD PRESSURE MONITORAutomatic Wrist Type 1
  • 2. TABLE OF CONTENTS OF CONTENTS Th Before using the Monitor Au 1. Introduction ................................................. 3 Fi 2. Safety Information ....................................... 4 D 3. Device Description ..................................... 5 4. Device Function .......................................... 6 S 5. How to Install the Battery ............................ 7 S 6. Specifications ............................................. 8 7. Applying The Cuff ...................................... 9 R ht 8. Before Taking a Measurement ................. 11 Blo 9. Measure the Blood Pressure .................... 12 10. Setting the Date and Time ........................ 14 11. How to view average value ....................... 15 12. How to Maintain and store the unit........... 16 13. Limited Warranties .................................... 17 14. Troubleshooting tips ................................. 18 15. State of Health .......................................... 192
  • 3. S 1. INTRODUCTION Thank you for purchasing the QS HEALTH Q-200 Automatic Wrist Blood Pressure Monitor.3 Fill in for future reference.4 DATE PURCHASED:56 SERIAL NUMBER:7 Staple your purchase receipt here.89 Register your product on-line at http://www.qs-health.com/product-register1 Blood Pressure Monitor CE ROHS FDA certificate2456789 3
  • 4. 2. SAFETY INFORMATION To assure the correct use of the product, basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. OPERATING THE DEVICE: Self-diagnosis and treatment using measured results may be dangerous.Follow the Instructions of your physician or licensed healthcare provider. DO NOT adjust medication based on measurement results from this blood pressure monitor take medication asprescribed by your physi- cian. Only a physician is qualified to diagnose and treat High Blood Pressure.The monitor is not intended to be a diagnostic device. Read all of the information in the instruction manual and any other literature in the box before operating the unit. This device is intended for use in measuring blood pressure and pul- se rate in the adult population.Do not use this device on infants or persons who cannot express their intentions. Operate the device only as intended. Do not use the device for any other purpose. Do not use a cellular phone near the device. It may result in an operational failure. Use only 1.5 V “AAA” alkaline batteries with this device. Do not use other types of Batteries This may damagethe unit.4
  • 5. 3. DEVICE DESCRIPTIONrestedingour hisysi-oodanyul- oranymayuse 5
  • 6. P 4. DEVICE FUNCTION The rate LED light signs the state of health. me 4-person memory zones, each 99-reading with measuring date/time Quick and clinically accurate measure blood pressure and pulse rate B Automatic determines ideal cuff inflation. Dis Completely automatic, operates with the push of a button Clear easy to read digital display Afte Average value for last three records pre High and Low pulse rate indicator If y Warning heart blinker, shows that the monitor is taking measurement mm Ultra compact design. -sta Selectable Kpa and mmHg ste Automatic shut off in 1 minute, power saving Low battery indicator Operated by 2 x1.5v “AAA” batteries. A. When the user measures the blood pressure and intend to delete any record. Please take the following step.*press button twice to enter into memory display, then press button around 3 seconds that will A. show “Clr” on LCD, then press button. B. If the user intend to clean all records, please take the following step. B. *Press button twice to enter into memory display, then press button around 3 seconds that will show “CLr ” on LCD, then press button, it will show “ ALL ”, then press button. C.6
  • 7. Pulse Function There are two warning signs (PH and PL) to display with the “Pulse rate” if the user’s pulse rate is high or low. The warning sign “PH” means “Pulse” High The warning sign “PL” means “Pulse” Lowmeate Battery Indicator: Display 3 level battery capacitive indicator during measurement. After setting, display will show “Kpa” “ON” or “OF”, you can select pressure unit with mmHg or Kpa. ON means Kpa, OF means mmHg. If you selected the Kpa for pressure unit, but you want to returnent mmHg, you should move the batteries around 3 minutes, then re- -start the device, it will be revert mmHg or you repeat the above step again 5. HOW TO INSTALL BATTERYanynterwill A. Remove the battery cover in accordance with thedirection of arrow.ep. B. Insert 2 x “AAA” batteries iness accordance with the indication ofess polarities on the batteries. C. Slide the battery cover to close. 7
  • 8. 6. SPECIFICATIONS Type: Wrist Blood Pressure Monitor CA 4 Person Memory: 1 ~ 99 with data and time stamp Rea Measurement Method: Oscillometric Method Technology lite Measurement Range: Pressure: 30 ~ 280 mmHg Do Pulse Rate: 40 ~ 195 beats / min the Accuracy Pressure: within ±3 mmHg Pulse rate: within ±5% of reading AP Inflation: Automatic inflation via pump Selectable between mmHg and Kpa 1 Auto Power off: 1 minute after last key operation Operating Temperature: 10 ~ 40 °C (50 ~ 104 °F) Operating Humidity: 30 ~ 85% R.H. Storage Temperature: -20 ~ 60 °C (-4 ~ 140 °F) Storage Humidity: 10 ~ 95% R.H. Power supply: 2 x1.5v “AAA” Alkaline batteries Wrist Circumference: 13.5 ~ 19.5 cm (5.31 ~ 7.68 inch) Item Dimension: approx. 69 (L) x 63.5 (W) x 37.5 (H) mm (2.72’ x 2.5’1.48’ inch) (excluding cuff) Item Weight: approx. 110 g - 3.88 ozsetting the advanced positioning sensor (APS) NOTE: These specifications are subject to change without notice8
  • 9. 7. APPLYING THE CUFFCAUTIONRead all of the information in the instruction manual and any otherliterature in the box before operating the unit.Do not use this device on infants or persons who cannot expresstheir intentions.APPLYING THE WRIST CUFF 1 Roll up sleeve. Make sure your sleeve is not rolled up too tightly on your arm. This may constrict the flow of blood in your arm. 2 Wrap the cuff directly 3 Position the cuff leaving against your skin do a clearance of appro- not apply over clothing. ximately ½ to 1 inch Place the cuff over your between the cuff and the left wristwith your left bottom ofyour palm thumb facing upward. 9
  • 10. 4 Hold the bottom part of the cuff and wrap it around the wrist so it fits comfortably and securely To aroundyour wrist. 1. NOTE: Make sure the wrist thin cuff does not cover the min protruding part of the wrist bone on the outside ofthe wrist. 2. stre 5 Fold the remaining part APPLYING THE CUFF 3. ON THE RIGHT WRIST of the wrist cuff back out 4. of the way. When taking a measurement 5. using the right wrist position the cuff as shown in the 6. illustration.Refer to “Setting for Right or Left Wrist for 7. Measurement”. the me 8. phy cat ralr at t10
  • 11. 8. Before taking a meassurementTo ensure a reliable reading follow these recommendations1. Avoid eating, drinking alcohol, and smoking, exercising, and ba-thing for 30 minutes before taking ameasurement. Rest for at least 15minutes before taking the measurement.2. Stress raises blood pressure. Avoid taking measurements duringstressful times.3. The cuff can be applied to your left or right wrist.4. Measurements should be taken in a quiet place.5. Position the unit at heart level throughout the measurement.6. Remain still and do not talk during the measurement.7. Wait 2-3 minutes between measurements. The wait time allowsthe arteries to return to the conditionprior to taking the blood pressuremeasurement.8. Keep a record of your blood pressure and pulse readings for yourphysician. A single measurementdoes not provide an accurate indi-cation of your true blood pressure. You need to take and record seve-ralreadings over a period of time. Try to measure your blood pressureat the same time each day forconsistency. 11
  • 12. B. 9. MEASURE THE BLOOD PRESURE Ho Sit Home Guideline for Upper Limit of Normal BP C. Systolic Blood Pressure 135 mmHg, Diastolic Blood Pressure 85 mmHg 1.Be ready to measurement A. Turn the unit facing toward body, Place the unit on wrist with both display panel and palm up. B. Leave about 1 cm distance between palm and the unit. C. Fasten the cuff securely around bare skin, seat upright and be ready to start. 2.To start the measurement 3. A. Sit comfortably in a chair A. with your feet flat on the floor. val B. pre C. D. ma12
  • 13. B. Hold your arm across your chest at heart level. Hold your elbow firmly to avoid body movement. Sit still and do not talk or move during the measurement. C. Press button to turn on the monitor.oth 3. Finish the measurement A. After detecting systolic/diastolic values and pulse rate, them values will be displayed on the LCDdisplay. B. After themeasuring session, if you want to measure again,just press button. C. Press buttonto turn off the unit. D. If you forget topress the button, the power will turn offauto- matically after 1minutes. 13
  • 14. 10. HOW TO SET TIME AND DATE Generally, LCD panel displays Month/Date/Hour/Minute.Once you Thi intend to set the time. Please operate as below: The 1. Press button at least 5 seconds, then the YEAR“2008” will 1. appear and blinking. 2. 2. Then press to forward YEAR setting, also youcan press to backward YEAR setting. 3. After finishing it, you can press button again. Nowyou can adjust Month/Date/Hour and Minute as youdesired. • After setting, display will show “Kpa” “ON” or “OF”, youcan select pressure unit with mmHg or Kpa. ONmeans Kpa, OF means mmHg.14
  • 15. 11. HOW TO VIEW AVERAGE VALUEu This unit could offer average value for user reference automatically. The average is decided by user’s latest 3 measurements.l 1. Press , you can view the value for latest 3 measurements. 2. You can press to read the other person’s average values. 15
  • 16. 12. How to maintain and store the unit 1. Use a dry, soft cloth to clean the unit, if desired, or use a cloth You lightly dampened with tapwater. ran ring 2. Do not use alcohol, benzene thinner or other harsh chemicals to ce clean the device or cuff. 3. Before measuring, please wash your hand. The 4. Do not wash or wet the cuff. obt 519 5. Keep away from direct sunlight, high humidity or dust for storage. clo 6. Do not subject the monitor to strong shocks, such as dropping the pho unit on the floor. QS 7. Do not submerge the device or any of the components in water. TH 8. Store the device and the components in a clean, safe location. TCO 9. Changes or modification not approved by the manufacturer will void FO the user Vis 10. Warranty. Do not disassemble or attempt to repair the unit or htt components. Ca Note: When the unit will not be used for a long time, be sure to remo- ve the batteries. Otherwise, thebatteries may leak damage to the unit.16
  • 17. t 13. LIMITED WARRANTIES oth Your QS HEALTH Q-200 Automatic blood pressure monitor , iswar- ranted to be free from defects in materials and workmanshipappea- ring within 2 years from the date of purchase, when used inaccordan-s to ce with the instructions provided with the monitor. The abovewarranties extend only to the original retail purchaser.To obtain warranty service contact Customer Service by calling 1-786 519 1206 for the address of return shipping and handling fee. En- e. close the Proof of Purchase. Include a letter, with your name,address, the phone number, and description of the specific problem. QS HEALTH SHALL NOT BE LIABLE FOR LOSS OF USE OR ANYO- THER SPECIAL, INCIDENTAL, CONSEQUENTAIL OR INDIREC- TCOSTS, EXPENSES OR DAMAGES.oid FOR CUSTOMER SERVICE Visit our web site at: or http://www.qs-health.com/technical-support Call 1-786-519-1206mo-nit. 17
  • 18. 14. TROUBLESHOOTING TIPS Phenomenon Problems Solutions Sta Nothing is 1.Batteries exhausted. Replace the batteries tob displayed when 2.The polarities of with new ones (W you press the batteries in the wrong Power position the “ Err P ” shown Fail to inflate 1.Please check the connection on O on LCD display main unit and cuff. If loosened, then connect them tightly. G 2.Please check if air tube isbroken, then change it “ Err 1 ”shown 1.The cuff is loosened. 1.Fasten the cuff, stant it again. on LCD display 2.Deflate too fast 2.Please send it to service station “ Err 2 ”shown 1.Movements occur on 1.Keep still after you press on LCD display the wrist. Power button - 2.Please remove 2.Interference signal interfering sources from Magnetic around the BPM. material or cell phone “ Err 3 ”shown Incorrect measured 1.Take off your watch or cuff on LCD display result might be placed incorrectly. Please re-wrap cuff in correct position. 2.You might use it incorrectly, such as measure blood pressure on child • If correct measurement is impossible even after checking the above mentioned points, consult at the store where you have purchased the unit or the nearest dealer without touching the internal mechanism. • In some very rare cases, there may be error due to the physical condition of the person. In such cases, please consult your doctor. • If LCD display doesn’t show anything, you may release Battery and install it again.18
  • 19. 15. STATE OF HEALTH Standards for assessment of high blood pressure, without regard tobage, have been established by the World health Organization (WHO), as shown in the chart below. It will help users to find out their health situation. Optimal; Normal; High-normal; Grade 1 hypertension; Grade 2 hypertension; Grade 3 hypertensionnedaler thein. 19
  • 20. QS HEALTH Inc. PO BOX 01-2412 • Miami FL 33101 • United States Phone: 1-786-519-1206 www.qs-health.com Copyright © 2011 QS HEALTH, Inc. Made in China20