  • 1. Hendre Ifan Goch Farm 5.5 Kw Hydro Generator
  • 2. Stages in development •Feasibility Study by Roberto Sotgiu – Hydrolite Ltd •Planning •Environment Agency approval •Installation •MCS registration •FIT registration
  • 3. Measurements on site
  • 4. INSTALLATION OF PIPES
  • 5. 180mm SDR black Pipe 100 m coils
  • 6. Pipe uncoiled and stretched
  • 7. Pipes into Generator House Installation of Generator
  • 8. New Filter Fitted June 2013
  • 9. Facts & Figures Feasibility Report £ 287.70 Cost £15,590.00
  • 10. Intake, Catchment & turbine house location • Both intakes will require adequate screening to prevent the ingress of debris,frogs or stones • Estimated annual rainfall runoff within Catchment is 1431mm • An estimated annual yield of 16.7 MWh = reduction of carbon emission of roughly 8 tonnes /year
  • 11. Costs Estimated Cost & PayBack Item Details Cost Intake 2 x St/steel wire remveable Filter £ 500.00 Penstock Cable & Pipe Trench Penstock upgrade Existing Self Fit 350m 180mm black SDR 17 10 bar HPPL Pipex Coils 5 no Fusion Connectors £ 3,460.00 £ 100.00 Tubine Housing Existing £ 8,800.00 Turbine Manifold st/steel manifold with st/steel flexi houses etc Turbine Casing Med st/Steel Case, 1 window Turbine & Arbour 20 orange cups Nozzles 1 x SV3 Mechanical Installation Turbine, Manifold Assy Generator & Controller Grid Linking Controller & Induction Generator Electrical Installation Metering ,disconnects,safety test certificate,cable handling Signal Cabling 400m of 3 core 1.5mm armoured , glands etc £ 1,130.00 Export Cabling 320m of 3 core 35mm armoured, glands etc Transformer upgrade if required £ - Design Turbine house layout,turbine design,intake design,onsite work,scheduling deliveries & contract labour; liasing with suppliers;DNO Application;Ofgem consultationProject Management £ 1,000.00 Travel £ 300.00 Licensing EA & Planning £ 300.00 Total Cost £ 15,590.00 EST Annual Revenue Actual 1st year £5423.19 £ 4,003.00 Pay Back Time 4 years