  1. 1. PFT Insertion Paddle Wheel Flow Sensor The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc
  2. 2. PFT Flow TransmitterInsertion Paddlewheel Transmitter A square wave output signal is generated with frequency proportional to flow velocity
  3. 3. FeaturesBearings and shaft offerexcellent wear protectioneven in applications withparticulate for long lifeWeatherproof andsubmersible rated forirrigation applications
  4. 4. FeaturesThe PFT uses inductive sensing to sense theblades of the impeller as they rotate. Sensortechnology does not use magnets allowing lowflow rate monitoring and no concerns withmagnetic material in the flowPaddlewheel, shaft and bearings are easilyfield replaceable
  5. 5. FeaturesFits pipes from .038 to 1.016 m with just onesize adjustable sensor Unit extends according to pipe size it is used in
  6. 6. SpecificationsService: Water-based fluidsRange: 0.37 to 7.62 m/sWetted Materials: Body and fitting: brass or316SS; fitting o-ring: FKM standard, silicone orBuna-N optional; impeller: 316 SS; shaft: 316 SSstandard or tungsten carbide optional; bearing:PTFE; polysulfone.Linearity: ± 1.0% of full range
  7. 7. SpecificationsRepeatability: ±0.5% of full rangeTemperature Limits: -40 to 100°CPressure Limits: 27.6 bar @ 37.8 °C, 22.4 bar @ 100°CProcess Connection: 1-½” NPT male standard, 2” NPTmale optional
  8. 8. SpecificationsOutput: NPN open collector with square waveoutput. 60V @ 50 mA maximumFrequency: 3.2 to 200 HzPulse Width: 2.5 msec ±25%Power Requirement: 10 to 35 VDC
  9. 9. SpecificationsElectrical Connection: 22 AWG shielded UL typePTLC rated 105°C, 6.1 m long with cable gland. Can beextended up to 609 m with similar cable. Optional ULlisted burial rated cable.Enclosure Rating: IP67 (Submersible)Housing Materials: Brass or 316 SSWeight: 1.81 kgAgency Approvals: CE
  10. 10. Basic ModelsModel Description List PricePFT-IDN-B111-S Brass Body $360.00PFT-IDN-S111-S 316 SS Body $535.00
  11. 11. Options2” NPT connectionBurial rated cableExtended cableOther wetted materialsSoon to come: 4 to 20 mA linear output
  12. 12. ApplicationsBuilding Automation Monitoring of chilled water supply and return in the building or chiller plant Can be used for thermal flow calculations with controller or building system
  13. 13. Cooling Loop
  14. 14. ApplicationsIrrigation Monitor flow rate in water lines Leak detection Even small leaks can create erosion, property damage, and waste expensive water A 4” line can dispense 100,000 gallons per hour Signal to controller to close valve in the line
  15. 15. ApplicationsIrrigationGolf courses, footballfields, farming,business parks
  16. 16. ApplicationsFertigation Monitor flow rate for addition of fertilizer with irrigation water
  17. 17. ApplicationsGeneral industry flow rates Pump proving Leak detection Flow rate monitoring
  18. 18. QuestionsTo order a free catalog or for more information contact; Dwyer Instruments, Inc., P.O. Box 373, Michigan City, IN., 46361 Telephone: (800) 872-9141 or (219) 879-8000 Fax: (219) 872-9057 Internet address: www.dwyer-inst.com E-mail: info@dwyer-inst.com

×