  • Accuracy is +/- 2% for ranges 0-250 Pa and below.Mounting: Gage is not sensitive to mounting orientation. No gravity effects
  • Filter type = HIGH. The display blinks when pressure is greater than the filter point.Filter type = LOW. The display blinks when pressure is less than the filter point.
  • If line power is lost, 9V battery will act as backup. Maintains the ability to read the gage during a power outage.
  • Picture on Right: Clean Room Airflow Path: Air is blown in through ductwork at top of room. The Filtered air “washes” down over the working area, and is exhausted through vents near bottom of room.
  • Filter installed to clean both incoming outside air, and the conditioned return air.
  • Fans should produce a specific volume of air at a specific speed. Variations of flow vs. speed can indicate blockage or fan damage. See manufacturer’s fan curve for data.
  • A duct leakage performance test involves pressurizing the duct system and simultaneously measuring the air flow through the fan and its effect on the pressure within the duct system. The tighter the duct system, the less air you need from the fan to create a change in duct system pressure.

Series DM Series DM Presentation Transcript

  • Series DM-1000 DigiMag® Digital Differential Pressure and Flow Gages
    The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc
  • Series DM-1000
    DigiMag® = Digital Magnehelic®
  • Key Features
    Large 4-digit LCD display
    +/- 1% F.S. Accuracy
    Ranges as low as +/-62.2 Pa
    Powered by 9-24 VDC or 9V battery
    NEMA 4X (IP66) enclosure
    Position insensitive
  • Key Benefits
    Local Alarm Status
    Display blinks when local setpoint reached
    Same Panel Cut-out as Magnehelic®
    Pop-in replacement for existing gage
    Field Selectable Engineering Units
    Stock fewer gages on shelves
  • Local Alarm Status
    Programmable Setpoint
    Display Blinks when Setpoint is reached
    “Filter is dirty”
    Visual alert of critical condition
    “HIGH” or “LOW”
  • Engineering Units
    Available for DM-1100:
    in. WC
    PSI
    kPa
    Pa
    mm WC
    in. Hg
    mm Hg
    % of Full Scale
  • DM-1200
    Air Velocity and Flow Gage
    K-Factor adjustment for various stations and pickups
    Enter duct dimensions directly to display FLOW
    No need for custom scales
    Quicker Delivery!
  • Engineering Units
    Available for DM-1200:
    SFPM
    SCFM
    m/sec
    m^3/hr
  • Power Requirements
    9-24 VDC Line Powered
    9V Battery Powered
  • Power Requirements
    9-24 VDC Line Powered With Battery Backup!!
  • Applications
    Clean Rooms
    Air Handlers
    Duct Pressure Monitoring
    Exhaust, Leakage testing
    General Filter Monitoring
  • Applications
    Clean Rooms
    An area with a controlled level of particulate contamination
    Positively Pressurized : In case of leaks, clean air leaks out instead of dirty air rushing in.
    Common in manufacturing facilities
    Pharmaceutical, semiconductor
  • Applications
    Clean Rooms
  • Applications
    Air Handlers – Filter Status
    Filter in mixed air stream, just before the fan
  • Applications
    Air Handlers – Volumetric Flow
    Monitor air flow at outlet of fan cone in AHU
    Prove fan is working efficiently
  • Applications
    Duct Leak Detection
    Measure Air Flow and Static Pressure in duct
    Leakage must be less than 1% of total CFM in a system
    Minimizes Energy Costs
  • Applications
    Filter Status – Indoor Air Quality
    Measure differential pressure across filter bank in a home
  • Ways to Sell
    Easy upgrade from a Magnehelic® gage
    Ideal for Filter Applications
    Better accuracy and readability than a mechanical gage
  • Questions