    • Air Quality Test Instruments Series AQTI Featuring the Versatile UHH Universal Handheld The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc.
    • AQTI Air Quality Test InstrumentsThe Most Complex Instrument LineDwyer has Ever ProducedSeries AQTI Consists of: New UHH Universal Handheld Base Various Sensing Probes & ModulesCreates New Line of Testing Equipmentfor Technicians, Contractors & Balancers
    • Capabilities of the UHHOne Base UHH be Combined with AnyCompatible Wired or Wireless Probe or ModuleLarge, Brightly Backlit OLED Color DisplayRubber Over-Mold Body with Rubber CapsProtects Unit from Dust & Water DamageMultiple Languages: English, German, Italian,Spanish, French & Portuguese
    • Features of the UHHLarge, Brightly Backlit OLED ColorDisplayRubber Over-Mold Body with RubberCaps Protect Unit from Dust & WaterDamage
    • Features of UHHRechargeable Battery – Charged byIncluded USB Cable with Adapter Less Potential for Batteries to Die During Usage and Test SamplingProgrammable Power Management toConserve Energy While Not Being Used Sleep Time Shut-Down Time
    • Features of UHHBuilt-in Clips for Included Hand StrapAllows User to Attach and Secure to: Belt Ladder Pipe Guard Rail Common Technician Need to Secure Unit so Hands are Free to Hold Probe and Take Readings. Provides Easier View of Display.
    • Operating the UHHFour Directional Arrow ButtonsEnter/On/Off ButtonThree Soft Keys Allow for Quick Navigation through Programming Settings within the Four Main Menus
    • UHH Features Summary
    • UHH Features Summary
    • Display Capabilities of UHHDisplay Mode: Meter Mode – Numerical Values
    • Display Capabilities of UHHDisplay Mode: Gage Mode – Analog Gage Needle
    • Display Capabilities of UHHDisplay Mode: Range Mode – Same as Gage But w/ Safe Operation Band
    • Display Capabilities of UHHDisplay Mode: Strip Chart Mode – Shows Long Term Process on Graph
    • Reading Capabilities of UHHReadings of Average, Total & Peak/Valley Average Very Important in Many Standards such as Average Volumetric Flow of Duct Traverse Peak/Valley Temperature Readings Over Period of Time Required to Ensure Duct Traverse Manufacturing or Lab Limits are not Exceeded for Process
    • Capabilities of UHHTime Stamped Manual or Automatic DataStorage (Data Logging) of Readings Common Contractor & Balancer Requirement to Document Readings for Client. School Example: Readings Stored During Multiple Class Room Duct Trees Balancing to Prove Sufficient Air Flow Demanded by Standards were Properly Set.
    • Capabilities of UHHData Storage Function Manual Start: Store Continuously at Preset Sampling Rate Until Log Manually Stopped. Log Can End Also by Timed Duration Single Point Log – Data Stored Manually Duct Traverse Each Time Log Button Pushed. Most Common For Duct Traverse by HVAC Balancer.
    • Capabilities of UHHData Storage Function Automatic Start: Begin Log by a Trigger (or Set Point) Example: Start When Rises Above 5 m/s. Trigger Set to be Inside or Outside a Zone. Example: Start when Either Below 2 m/s and above 5 m/s. OR Above 2 m/s and Below 5 m/s A Delay Can be Set on the TriggerStop Log: Manually or a Timed Duration
    • Capabilities of UHHStored Data Downloaded by USB or SDCard USB Compatibility Allows for Users to Conveniently Download Data of their Records to a Computer. SD Card Allows User to Simply Take Card Back to Office, Leave Test Equipment At Job or in their Truck or Van.
    • Air Quality Test Instrument Offering Series AQTI Includes AQTI=UHH + Probe + Strap + Charger + Soft Case USB Cable + Int. Adapters
    • Air Quality Test Instrument OfferingPro Series AQTIP AQTIP = AQTI BUT WIRELESS Probe, + Hard Carrying Case + 2 GB SD Card + NIST Test Certificate
    • Air Quality Test Instrument OfferingSeries AQTI Model AQTI-01 UHH Universal Handheld with Thermo Anemometer Wired Air Velocity/Temperature ProbePro Series AQTIP Model AQTIP-01 UHH Universal Handheld with Thermo Anemometer Wireless Air Velocity/ Temperature Probe
    • Thermo Anemometer ApplicationsFume Hood FaceVelocityFan TrackingLeak CheckingProper Room AirVolume Turns
    • Air Quality Test Instrument OfferingSeries AQTI Model AQTI-02 UHH Universal Handheld with Vane Anemometer Air Velocity/Temperature Wired ProbePro Series AQTIP Model AQTIP-02 UHH Universal Handheld with Vane Anemometer Air Velocity/Temperature Wireless Probe
    • Vane Anemometer Applications Supply/Exhaust Diffusers Grilles Registers Diffuser Grille Register
    • Vane Anemometer ApplicationsLEED Energy AuditsFilter Selection/AssessmentHeating and Cooling CoilsVentilation Shafts
    • Air Quality Test Instrument OfferingSeries AQTI Model AQTI-03 UHH Universal Handheld with Humidity/Temperature Wired ProbePro Series AQTIP Model AQTIP-03 UHH Universal Handheld with Humidity/Temperature Wireless Probe
    • Humidity/Temp. ApplicationsInstrument ComparisonTest Analysis
    • Humidity/Temp. ApplicationsProper Levels in: Lab Clean Room Computer Room Office School Room
    • Air Quality Test Instrument OfferingSeries AQTI Models AQTI-05 thru AQTI-12Differential Pressure Manometer withWireless D.P. Module Ranges from +/-500 Pa (+/-2” w.c.) to +/- 100kPa (+/- 400” w.c.)
    • D.P. Manometer ApplicationsDuct StaticDuct Air Flowwith Pitot TubeHospital, IsolationRoom, & CleanRoom Pressures
    • UHH Hands-On TrainingSYS Menu: View STATUS of Probes Connected ACCESS SETTINGS WIRELESS ON/OFF CONTRAST RESTORE DEFAULTS
    • UHH Hands-On TrainingSYS Menu: SETTINGS Sub-Menu LANGUAGE UNITS TIME & DATE Power Management SLEEP SHUTDWON OWNER Name
    • UHH Hands-On TrainingPROBE Menu: View Probes or Modules TYPE Alter the MAJOR & MINOR Value on Home Display
    • UHH Hands-On TrainingPROBE Menu  TYPESub-Menu(Anemometer): DISPLAY Parameter Such as Velocity or Flow UNITS Such as FPM or MPS RANGE (*Anemometer Only)
    • UHH Hands-On TrainingPROBE Menu TYPE Sub-Menu(Temperature): UNITS F or C
    • UHH Hands-On TrainingVIEW Menu: VIEW Mode- Meter Adjust AVERAGE Time
    • UHH Hands-On TrainingVIEW Menu: Home Display Meter Mode
    • UHH Hands-On TrainingVIEW Menu: VIEW Mode- Gauge Adjust AVERAGE Time View Full Scale of Dial
    • UHH Hands-On TrainingVIEW Menu: Home Display Gauge Mode
    • UHH Hands-On TrainingVIEW Menu: VIEW Mode- RANGE Adjust AVERAGE Time View GAUGE Yellow Color Band Set Green RANGE Green Color Band
    • UHH Hands-On TrainingVIEW Menu: Home Display Range Mode
    • UHH Hands-On TrainingVIEW Menu: VIEW Mode- STRIP Chart Adjust AVERAGE Time Set STRIP Chart Scale Y-Axis Adjust STRIP Chart Time X-Axis
    • UHH Hands-On TrainingVIEW Menu: Home Display Strip Chart Mode
    • UHH Hands-On TrainingLOG Menu: Start or Stop LOG Adjust Sample RATE Select TRIGGER Method FILE FORMAT MEDIA LOG FILES
    • UHH Hands-On TrainingLOG Menu:  Log FileSub Menu Select Log File by Pressing VIEW Soft Key
    • UHH Hands-On TrainingLOG Menu:  Log FileVIEW Sub Menu FILE Numerical Order in List & File Name DATE & TIME MAJOR & MINOR Values- Scroll Through Each Reading with Arrows
    • UHH Hands-On TrainingLOG Menu: ViewLog File Statistics Press STAT to View the Logged Data’s Total (if applicable) Average Peak/Valley
    • UHH Hands-On TrainingLet’s Store ReadingsFrom Home Screen:Trigger in LOG Menuof Manual or Single