Your SlideShare is downloading. ×
Series 3100 and Series 3200
Upcoming SlideShare
Loading in...5
×

Thanks for flagging this SlideShare!

Oops! An error has occurred.

×
Saving this for later? Get the SlideShare app to save on your phone or tablet. Read anywhere, anytime – even offline.
Text the download link to your phone
Standard text messaging rates apply

Series 3100 and Series 3200

343
views

Published on

Published in: Business, Technology

0 Comments
1 Like
Statistics
Notes
  • Be the first to comment

No Downloads
Views
Total Views
343
On Slideshare
0
From Embeds
0
Number of Embeds
0
Actions
Shares
0
Downloads
11
Comments
0
Likes
1
Embeds 0
No embeds

Report content
Flagged as inappropriate Flag as inappropriate
Flag as inappropriate

Select your reason for flagging this presentation as inappropriate.

Cancel
No notes for slide
  • Temperature Characterization
  • Transcript

    • 1. Series 3100 and 3200Industrial Pressure Transmitter
      The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc. ©Copyright 2011 Dwyer Instruments, Inc
    • 2. Features
      Can be configured with Zero/Span buttons, HART handheld communicator or HART communicator software
      FM and CE approved
      FM: Class I, Div I, Group A, B, C and D
      High or Low fail safe
      Output: 4-20mA / HART
      Additional terminals for HART communicator and multimeter.
      LCD and enclosure can be rotated
      100:1 Turndown
      Accuracy: 0.075% F.S.
    • 3. Enclosure Adjustments
      Enclosure can be rotated 360⁰
      LCD can be rotated 270⁰
    • 4. Mechanical Features
      3100 comes standard with bleed fittings
      Front and back enclosure covers are lockable.
    • 5. Smart Transmitter
      Nonlinearities and temperature dependencies of the pressure sensor are eliminated.
      Smart Transmitter
      Conventional Transmitter
    • 6. HART
      The 3100/3200 transmitters are equipped with analog (4-20mA) and digital (HART) communication.
    • 7. Push Button Configuration
      The 3100/3200 can be configured using the Zero/Span buttons
      The Zero/Span buttons allow the transmitter to be configured without opening the housing covers
    • 8. Failsafe
      The failsafe can be programmed to fail High (21.75mA) or Low (3.75mA) if the self-diagnostic test detects a failure.
    • 9. Turndown Explanation
      Example:
      Nominal lower value (LRL) = 0 bar
      Nominal upper value (URL) = 100 bar
      Lower-range value (LRV) = 0 bar
      Upper-range value (URV) = 1 bar
      Turndown:
      Nominal upper value(URL)/Upper-range value (URV)
      100/1 bar
      TD = 100:1
    • 10. Installation
      Steam Service
      Liquid Service
      Air Service
    • 11. Calibration Frequency
    • 12. Calculations
    • 13. Options
      Diaphragm Seals
    • 14. Options
      316 SS Housing
    • 15. Options
      Custom Calibration Parameters
      3100
    • 16. Options
      Custom Calibration Parameters
      3200
    • 17. Accessories
      BBV Valve Manifolds
      2 Valve Manifolds
      3 Valve Manifolds
      5 Valve Manifolds
      COM-PC HART Communicator Software
      HART Software with all registered DD (Device Description) files
      Includes USB HART Modem
    • 18. Accessories
      Mounting Brackets
      A-630 Angle Bracket
      A-631 Flat Bracket
    • 19. Target Industries
      Water & Waste Water Facilities
      Chemical & Petrochemical Plants
      Oil & Gas Refineries
      Pulp & Paper Processing Plants
      Food & Beverage Plants
      Renewable Energy & Alternative Fuels
      Soil Remediation
      Iron & Steel Foundries
      Test & Measurement Labs
    • 20. Level Application
      The 3100 can be used to monitor the level in a closed or open tank.
      The transmitter range can be adjusted to compensate for specific gravity.
    • 21. Gas Train Application
      The 3100 is used to monitor the air or air/gas mixture flow into a combustion chamber.
    • 22. Filter Applications
      The 3100 can be used to measure the pressure drop across air filters, liquid filters and reverse osmosis systems in hazardous locations.
    • 23. Refining Application
      The 3100 and 3200 are used to monitor processes converting raw resources to refined natural gas, diesel or gasoline.
    • 24. Oil Well Application
      The 3200 is used to monitor the well pressure to prevent blowouts.
    • 25. Water Pressure Application
      The 3200 is used to monitor the water level in a tower and pump pressure.
    • 26. Food Processing Application
      The 3200 is used to monitor pressure in cooking and processing lines to prevent blockages.
    • 27. Questions
      To order a free catalog or for more information contact;
      Dwyer Instruments, Inc., P.O. Box 373,
      Michigan City, IN., 46361
      Telephone: (800) 872-9141 or (219) 879-8000
      Fax: (219) 872-9057
      Internet address: www.dwyer-inst.com